W912CJ-17-T-0003
Section SF 1449 - CONTINUATION SHEET
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Total & E.Coli Coliform -Colilert P/A
FFP
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
FOB: Destination
PURCHASE REQUEST NUMBER: 0010918982-0002
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
Total E.Coli Colif Colilert P/A Resample
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 16 |
| Each |
Total & E.Coli Coliform -QT -Colilert -1
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Total & E.Coli Coliform -QT -Colilert -100 with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
E.Coli Coliform -Colilert P/A Resample P
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 104 |
| Each |
Alkalinity (Bicarbonate, Carbonate, Hydr
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Alkalinity (Bicarbonate, Carbonate, Hydroxide) with Analytical Method SM2320B or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Nitrate (NO3 or NO3-N)
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrate (NO3 or NO3-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
Perchlorate
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Perchlorate with EPA 314.0 Analytical Method or Most Current. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Nitrite (as N)
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrite (as N) with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
SOC
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): SOC with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Inorganic
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Inorganic with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Secondary/GP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Secondary/GP with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Radiological – Gross Alpha
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Radiological – Gross Alpha with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 104 |
| Each |
Total & E.Coli Coliform -Colilert P/A
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
Total & E.Coli Coliform -Colilert P/A Re
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
Phosphate (PO4)
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Phosphate (PO4) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
Trihalomethanes
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Trihalomethanes with EPA 551.1 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
Haloacetic Acids
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Haloacetic Acids with EPA 552.2 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
Lead (Pb) & Copper (Cu)
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Lead (Pb) & Copper (Cu) with EPA 200.7/200.8 Analytical Method or Most Current. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
Field Test -Field Temperature
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Temperature with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
Field Test -Field Chlorine Residual, Fre
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Chlorine Residual, Free or Total (Cl) with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
Field Test -Field pH
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
Settleable Solids (SS)
Perform sampling and analysis of Wastewater and Sludge samples as follows: Settleable Solids (SS) with SM2540F Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
Biochemical Oxygen Demand (BOD5)
Perform sampling and analysis of Wastewater and Sludge samples as follows: Biochemical Oxygen Demand (BOD5) with SM5210B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
Total Suspended Solids (TSS)
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Total Nitrogen (TKN + NO3-N + NO2-N)
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Nitrogen (TKN + NO3-N + NO2-N) with calculation method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Nitrite (NO2 or NO2-N)
Perform sampling and analysis of Wastewater and Sludge samples as follows: Nitrite (NO2 or NO2-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 6 |
| Each |
Chloride (Cl)
Perform sampling and analysis of Wastewater and Sludge samples as follows: Chloride (Cl) with EPA 300.0 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Prep for Total Metals Analysis
Perform sampling and analysis of Wastewater and Sludge samples as follows: Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Individual Metals -Na
.Perform sampling and analysis of Wastewater and Sludge samples as follows: Individual Metals -Na with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
Field Test -Field pH
Perform sampling and analysis of Wastewater and Sludge samples as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Total Dissolved Solids
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Dissolved Solids with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Total Organic Carbon (TOC)
Perform analysis of Storm Water samples as follows: Total Organic Carbon (TOC) with SM 5310C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Total Suspended Solids (TSS)
Perform analysis of Storm Water samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Electrical Conductivity (EC)
Perform analysis of Storm Water samples as follows: Electrical Conductivity (EC) with SM2510B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Storm Water Samples pH
Perform analysis of Storm Water samples as follows: pH with SM4500-HB Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Prep for Total Metals Analysis
Perform analysis of Storm Water samples as follows:Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Individual Metals -Cu,Pb,Ni,Zn
Perform analysis of Storm Water samples as follows: Individual Metals -Cu,Pb,Ni,Zn with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
TPH -Full List GRO+DRO (Petroleum Produc
Perform analysis of Storm Water samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Liquid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
Total Extractable Hydrocarbons
Perform analysis of Storm Water samples as follows: Total Extractable Hydrocarbons with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
TPH -GRO (Gasoline Range Organics) (Soli
Perform analysis of Hazardous Waste samples as follows: TPH -GRO (Gasoline Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
TPH -DRO (Diesel Range Organics) (Solid)
Perform analysis of Hazardous Waste samples as follows: TPH -DRO (Diesel Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
TPH -Full List GRO+DRO (Petroleum Produc
Perform analysis of Hazardous Waste samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
CAM 17 Metals + Sample Prep
Perform analysis of Hazardous Waste samples as follows: CAM 17 Metals + Sample Prep: Sb, As, Ba, Be, Cd, Cr, Co, Cu, Pb, Hg, Mo, Ni, Se, Ag, Tl, V, Zn (Solid) with EPA 6010B/ 6020/ 7000 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
VOC's Full List (Solid)
Perform analysis of Hazardous Waste samples as follows: VOC's Full List (Solid) with EPA 8260B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Semi-Volatile Organics Full List (Solid)
Perform analysis of Hazardous Waste samples as follows: Semi-Volatile Organics Full List (Solid) with EPA 8270C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
Hazardous Waste Asbestos
Perform analysis of Hazardous Waste samples as follows: Asbestos with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
Weekly Sampling Fee
Weekly Sampling Fee
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Contractor Manpower Reporting (CMR)
THE CONTRACTOR SHALL REPORT ALL CONTRACTOR MANPOWER
REQUIRED FOR PERFORMANCE OF THIS CONTRACT. PLEASE REFER
TO THE CMR USERS GUIDE AT THE WEBSITE PROVIDED IN THE PWS
TO ASSESS THE LEVEL OF EFFORT THAT WILL BE REQUIRED TO COMPLY WITH THIS REQUIREMENT. INPUTS MAY BE REPORTED ANYTIME DURING THE FISCAL YEAR, ALL DATA SHALL BE REPORTED NO LATER THAN OCTOBER 31 OF EACH CALENDAR YEAR. INVOICING FOR THIS CLIN SHALL NOT BE SUBMITTED FOR PAYMENT UNTIL COMPLETION OF REPORTING AS NDICATED.
IF NO DIRECT COST IS ASSOCIATED WITH PROVIDING THE DATA, ENTER “NO COST”.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A |
FFP
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Total E.Coli Colif Colilert P/A Resample |
FFP
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 16 |
| Each |
| OPTION |
| Total & E.Coli Coliform -QT -Colilert -1 |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Total & E.Coli Coliform -QT -Colilert -100 with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| E.Coli Coliform -Colilert P/A Resample P |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 106 |
| Each |
| OPTION |
| Alkalinity (Bicarbonate, Carbonate, Hydr |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Alkalinity (Bicarbonate, Carbonate, Hydroxide) with Analytical Method SM2320B or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Nitrate (NO3 or NO3-N) |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrate (NO3 or NO3-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Perchlorate |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Perchlorate with EPA 314.0 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Nitrite (as N) |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrite (as N) with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| SOC |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): SOC with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Inorganic |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Inorganic with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Secondary/GP |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Secondary/GP with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
| OPTION |
| Radiological – Gross Alpha |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Radiological – Gross Alpha with most current Analytical Method. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 106 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A Re |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Phosphate (PO4) |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Phosphate (PO4) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Trihalomethanes |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Trihalomethanes with EPA 551.1 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Haloacetic Acids |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Haloacetic Acids with EPA 552.2 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 20 |
| Each |
| OPTION |
| Lead (Pb) & Copper (Cu) |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Lead (Pb) & Copper (Cu) with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field Temperature |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Temperature with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field Chlorine Residual, Fre |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Chlorine Residual, Free or Total (Cl) with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field pH |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 53 |
| Each |
| OPTION |
| Settleable Solids (SS) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Settleable Solids (SS) with SM2540F Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Biochemical Oxygen Demand (BOD5) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Biochemical Oxygen Demand (BOD5) with SM5210B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Total Suspended Solids (TSS) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Total Nitrogen (TKN + NO3-N + NO2-N) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Nitrogen (TKN + NO3-N + NO2-N) with calculation method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Nitrite (NO2 or NO2-N) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Nitrite (NO2 or NO2-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Chloride (Cl) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Chloride (Cl) with EPA 300.0 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Prep for Total Metals Analysis |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Individual Metals -Na |
FFP
.Perform sampling and analysis of Wastewater and Sludge samples as follows: Individual Metals -Na with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 53 |
| Each |
| OPTION |
| Field Test -Field pH |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Total Dissolved Solids |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Dissolved Solids with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Organic Carbon (TOC) |
FFP
Perform analysis of Storm Water samples as follows: Total Organic Carbon (TOC) with SM 5310C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Suspended Solids (TSS) |
FFP
Perform analysis of Storm Water samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Electrical Conductivity (EC) |
FFP
Perform analysis of Storm Water samples as follows: Electrical Conductivity (EC) with SM2510B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Storm Water Samples pH |
FFP
Perform analysis of Storm Water samples as follows: pH with SM4500-HB Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Prep for Total Metals Analysis |
FFP
Perform analysis of Storm Water samples as follows:Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Individual Metals -Cu,Pb,Ni,Zn |
FFP
Perform analysis of Storm Water samples as follows: Individual Metals -Cu,Pb,Ni,Zn with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| TPH -Full List GRO+DRO (Petroleum Produc |
FFP
Perform analysis of Storm Water samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Liquid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Extractable Hydrocarbons |
FFP
Perform analysis of Storm Water samples as follows: Total Extractable Hydrocarbons with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -GRO (Gasoline Range Organics) (Soli |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -GRO (Gasoline Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -DRO (Diesel Range Organics) (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -DRO (Diesel Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -Full List GRO+DRO (Petroleum Produc |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| CAM 17 Metals + Sample Prep |
FFP
Perform analysis of Hazardous Waste samples as follows: CAM 17 Metals + Sample Prep: Sb, As, Ba, Be, Cd, Cr, Co, Cu, Pb, Hg, Mo, Ni, Se, Ag, Tl, V, Zn (Solid) with EPA 6010B/ 6020/ 7000 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| VOC's Full List (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: VOC's Full List (Solid) with EPA 8260B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Semi-Volatile Organics Full List (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: Semi-Volatile Organics Full List (Solid) with EPA 8270C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Hazardous Waste Asbestos |
FFP
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
| OPTION |
| Weekly Sampling Fee |
FFP
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Contractor Manpower Reporting (CMR) |
FFP
THE CONTRACTOR SHALL REPORT ALL CONTRACTOR MANPOWER
REQUIRED FOR PERFORMANCE OF THIS CONTRACT. PLEASE REFER
TO THE CMR USERS GUIDE AT THE WEBSITE PROVIDED IN THE PWS
TO ASSESS THE LEVEL OF EFFORT THAT WILL BE REQUIRED TO COMPLY WITH THIS REQUIREMENT. INPUTS MAY BE REPORTED ANYTIME DURING THE FISCAL YEAR, ALL DATA SHALL BE REPORTED NO LATER THAN OCTOBER 31 OF EACH CALENDAR YEAR. INVOICING FOR THIS CLIN SHALL NOT BE SUBMITTED FOR PAYMENT UNTIL COMPLETION OF REPORTING AS NDICATED.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A |
FFP
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Total E.Coli Colif Colilert P/A Resample |
FFP
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 16 |
| Each |
| OPTION |
| Total & E.Coli Coliform -QT -Colilert -1 |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Total & E.Coli Coliform -QT -Colilert -100 with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| E.Coli Coliform -Colilert P/A Resample P |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 113 |
| Each |
| OPTION |
| Alkalinity (Bicarbonate, Carbonate, Hydr |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Alkalinity (Bicarbonate, Carbonate, Hydroxide) with Analytical Method SM2320B or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Nitrate (NO3 or NO3-N) |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrate (NO3 or NO3-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Perchlorate |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Perchlorate with EPA 314.0 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Nitrite (as N) |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrite (as N) with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| SOC |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): SOC with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Inorganic |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Inorganic with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Secondary/GP |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Secondary/GP with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
| OPTION |
| Radiological – Gross Alpha |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Radiological – Gross Alpha with most current Analytical Method. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 104 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A Re |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Phosphate (PO4) |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Phosphate (PO4) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Trihalomethanes |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Trihalomethanes with EPA 551.1 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Haloacetic Acids |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Haloacetic Acids with EPA 552.2 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
| OPTION |
| Lead (Pb) & Copper (Cu) |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Lead (Pb) & Copper (Cu) with EPA 200.7/200.8 Analytical Method or Most Current. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field Temperature |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Temperature with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field Chlorine Residual, Fre |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Chlorine Residual, Free or Total (Cl) with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field pH |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
| OPTION |
| Settleable Solids (SS) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Settleable Solids (SS) with SM2540F Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Biochemical Oxygen Demand (BOD5) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Biochemical Oxygen Demand (BOD5) with SM5210B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Total Suspended Solids (TSS) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Total Nitrogen (TKN + NO3-N + NO2-N) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Nitrogen (TKN + NO3-N + NO2-N) with calculation method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Nitrite (NO2 or NO2-N) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Nitrite (NO2 or NO2-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Chloride (Cl) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Chloride (Cl) with EPA 300.0 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Prep for Total Metals Analysis |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Individual Metals -Na |
FFP
.Perform sampling and analysis of Wastewater and Sludge samples as follows: Individual Metals -Na with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
| OPTION |
| Field Test -Field pH |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Total Dissolved Solids |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Dissolved Solids with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Organic Carbon (TOC) |
FFP
Perform analysis of Storm Water samples as follows: Total Organic Carbon (TOC) with SM 5310C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Suspended Solids (TSS) |
FFP
Perform analysis of Storm Water samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Electrical Conductivity (EC) |
FFP
Perform analysis of Storm Water samples as follows: Electrical Conductivity (EC) with SM2510B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Storm Water Samples pH |
FFP
Perform analysis of Storm Water samples as follows: pH with SM4500-HB Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Prep for Total Metals Analysis |
FFP
Perform analysis of Storm Water samples as follows:Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Individual Metals -Cu,Pb,Ni,Zn |
FFP
Perform analysis of Storm Water samples as follows: Individual Metals -Cu,Pb,Ni,Zn with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| TPH -Full List GRO+DRO (Petroleum Produc |
FFP
Perform analysis of Storm Water samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Liquid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Extractable Hydrocarbons |
FFP
Perform analysis of Storm Water samples as follows: Total Extractable Hydrocarbons with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -GRO (Gasoline Range Organics) (Soli |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -GRO (Gasoline Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -DRO (Diesel Range Organics) (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -DRO (Diesel Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -Full List GRO+DRO (Petroleum Produc |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| CAM 17 Metals + Sample Prep |
FFP
Perform analysis of Hazardous Waste samples as follows: CAM 17 Metals + Sample Prep: Sb, As, Ba, Be, Cd, Cr, Co, Cu, Pb, Hg, Mo, Ni, Se, Ag, Tl, V, Zn (Solid) with EPA 6010B/ 6020/ 7000 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| VOC's Full List (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: VOC's Full List (Solid) with EPA 8260B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Semi-Volatile Organics Full List (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: Semi-Volatile Organics Full List (Solid) with EPA 8270C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Hazardous Waste Asbestos |
FFP
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
| OPTION |
| Weekly Sampling Fee |
FFP
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Contractor Manpower Reporting (CMR) |
FFP
THE CONTRACTOR SHALL REPORT ALL CONTRACTOR MANPOWER
REQUIRED FOR PERFORMANCE OF THIS CONTRACT. PLEASE REFER
TO THE CMR USERS GUIDE AT THE WEBSITE PROVIDED IN THE PWS
TO ASSESS THE LEVEL OF EFFORT THAT WILL BE REQUIRED TO COMPLY WITH THIS REQUIREMENT. INPUTS MAY BE REPORTED ANYTIME DURING THE FISCAL YEAR, ALL DATA SHALL BE REPORTED NO LATER THAN OCTOBER 31 OF EACH CALENDAR YEAR. INVOICING FOR THIS CLIN SHALL NOT BE SUBMITTED FOR PAYMENT UNTIL COMPLETION OF REPORTING AS NDICATED.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A |
FFP
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Total E.Coli Colif Colilert P/A Resample |
FFP
Perform Sampling and analysis of drinking water at Argyle and Lockwood Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 16 |
| Each |
| OPTION |
| Total & E.Coli Coliform -QT -Colilert -1 |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Total & E.Coli Coliform -QT -Colilert -100 with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| E.Coli Coliform -Colilert P/A Resample P |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 104 |
| Each |
| OPTION |
| Alkalinity (Bicarbonate, Carbonate, Hydr |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s):Alkalinity (Bicarbonate, Carbonate, Hydroxide) with Analytical Method SM2320B or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Nitrate (NO3 or NO3-N) |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrate (NO3 or NO3-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
| OPTION |
| Perchlorate |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Perchlorate with EPA 314.0 Analytical Method or Most Current. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Nitrite (as N) |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Nitrite (as N) with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| SOC |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): SOC with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Inorganic |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Inorganic with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Secondary/GP |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Secondary/GP with most current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
| OPTION |
| Radiological – Gross Alpha |
FFP
Perform Sampling and analysis of drinking water at four each Potable Wells for the following analyte(s): Radiological – Gross Alpha with most current Analytical Method. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 104 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
| OPTION |
| Total & E.Coli Coliform -Colilert P/A Re |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Total & E.Coli Coliform -Colilert P/A Resample Positives with SM9223B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Phosphate (PO4) |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Phosphate (PO4) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Trihalomethanes |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Trihalomethanes with EPA 551.1 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Haloacetic Acids |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Haloacetic Acids with EPA 552.2 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Each
| OPTION |
| Lead (Pb) & Copper (Cu) |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Lead (Pb) & Copper (Cu) with EPA 200.7/200.8 Analytical Method or Most Current. THIS CLIN HAS ZERO (0) QTY FOR THIS PERIOD OF PERFORMANCE.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field Temperature |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Temperature with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field Chlorine Residual, Fre |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field Chlorine Residual, Free or Total (Cl) with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Field Test -Field pH |
FFP
Perform Sampling and analysis of (#) drinking water Distribution System locations as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
| OPTION |
| Settleable Solids (SS) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Settleable Solids (SS) with SM2540F Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Biochemical Oxygen Demand (BOD5) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Biochemical Oxygen Demand (BOD5) with SM5210B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 12 |
| Each |
| OPTION |
| Total Suspended Solids (TSS) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Total Nitrogen (TKN + NO3-N + NO2-N) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Nitrogen (TKN + NO3-N + NO2-N) with calculation method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Nitrite (NO2 or NO2-N) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Nitrite (NO2 or NO2-N) with EPA 300.0/SM4500 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Chloride (Cl) |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Chloride (Cl) with EPA 300.0 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Prep for Total Metals Analysis |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Individual Metals -Na |
FFP
.Perform sampling and analysis of Wastewater and Sludge samples as follows: Individual Metals -Na with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
| OPTION |
| Field Test -Field pH |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Field Test -Field pH with Most Current Field Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
| OPTION |
| Total Dissolved Solids |
FFP
Perform sampling and analysis of Wastewater and Sludge samples as follows: Total Dissolved Solids with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Organic Carbon (TOC) |
FFP
Perform analysis of Storm Water samples as follows: Total Organic Carbon (TOC) with SM 5310C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Suspended Solids (TSS) |
FFP
Perform analysis of Storm Water samples as follows: Total Suspended Solids (TSS) with SM2540D Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Electrical Conductivity (EC) |
FFP
Perform analysis of Storm Water samples as follows: Electrical Conductivity (EC) with SM2510B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Storm Water Samples pH |
FFP
Perform analysis of Storm Water samples as follows: pH with SM4500-HB Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Prep for Total Metals Analysis |
FFP
Perform analysis of Storm Water samples as follows:Prep for Total Metals Analysis with EPA 3010A Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Individual Metals -Cu,Pb,Ni,Zn |
FFP
Perform analysis of Storm Water samples as follows: Individual Metals -Cu,Pb,Ni,Zn with EPA 200.7/200.8 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| TPH -Full List GRO+DRO (Petroleum Produc |
FFP
Perform analysis of Storm Water samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Liquid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 24 |
| Each |
| OPTION |
| Total Extractable Hydrocarbons |
FFP
Perform analysis of Storm Water samples as follows: Total Extractable Hydrocarbons with current Analytical Method.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -GRO (Gasoline Range Organics) (Soli |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -GRO (Gasoline Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -DRO (Diesel Range Organics) (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -DRO (Diesel Range Organics) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| TPH -Full List GRO+DRO (Petroleum Produc |
FFP
Perform analysis of Hazardous Waste samples as follows: TPH -Full List GRO+DRO (Petroleum Products) (Solid) with EPA 8015M Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| CAM 17 Metals + Sample Prep |
FFP
Perform analysis of Hazardous Waste samples as follows: CAM 17 Metals + Sample Prep: Sb, As, Ba, Be, Cd, Cr, Co, Cu, Pb, Hg, Mo, Ni, Se, Ag, Tl, V, Zn (Solid) with EPA 6010B/ 6020/ 7000 Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| VOC's Full List (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: VOC's Full List (Solid) with EPA 8260B Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Semi-Volatile Organics Full List (Solid) |
FFP
Perform analysis of Hazardous Waste samples as follows: Semi-Volatile Organics Full List (Solid) with EPA 8270C Analytical Method or Most Current.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
| OPTION |
| Hazardous Waste Asbestos |
FFP
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 52 |
| Each |
| OPTION |
| Weekly Sampling Fee |
FFP
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
| OPTION |
| Contractor Manpower Reporting (CMR) |
FFP
THE CONTRACTOR SHALL REPORT ALL CONTRACTOR MANPOWER
REQUIRED FOR PERFORMANCE OF THIS CONTRACT. PLEASE REFER
TO THE CMR USERS GUIDE AT THE WEBSITE PROVIDED IN THE PWS
TO ASSESS THE LEVEL OF EFFORT THAT WILL BE REQUIRED TO COMPLY WITH THIS REQUIREMENT. INPUTS MAY BE REPORTED ANYTIME DURING THE FISCAL YEAR, ALL DATA SHALL BE REPORTED NO LATER THAN OCTOBER 31 OF EACH CALENDAR YEAR.