Amendment #0002 to Solicitation W9128F-18-R-0041 Ammunition Supply Point Facility, Ft. Carson, CO
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Am-0004_W9128F-18-R-0041.pdf | ||
| Am-0003_W9128F-18-R-0041.pdf | ||
| Am-0001_W9128F-18-R-0041.pdf | ||
| W9128F-18-R-0041-Ammo-Supply-Point.pdf | ||
| FCBN_ADVERTISEMENT_-_SITE.PDF | ||
| FCBN_ADVERTISEMENT_-_BLDGS.PDF |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
Amendment No. 0002
AMMUNITION SUPPLY POINT, PN 73375 (FY18), FORT CARSON, COLORADO
See attached documentation for content of the amendment changes to RFP
Date for receipt of proposals is 16 AUG 2018 at 1400 hours
Government Point of Contact: Stephanie Harr, Contract Specialist (402) 996-3713
U.S.ARMY CORPS OF ENGINEERS, OMAHA
Rocky Mountain Area Office Attn: CONTRACTING DIVISION (CENWO-CT-M) 5475 Tech Center Drive, Suite 205 Colorado Springs, CO 80919
See Item 6
W9128F-18-R-0041
08/03/2018
07/13/2018
08/03/2018
Am #0002 - 1
Am #0002 - 2 (Continuation of SF30)
DEPARTMENT OF THE ARMY
Omaha District, Corps of Engineers
1616 Capitol Avenue Omaha, Nebraska 68102-4901
:NOTICE: Failure to acknowledge : Solicitation No. W9128F-18-R0041 :all amendments may cause rejec-:
:tion of the offer. See FAR : Date of Issue: 13 JUL 2018 :52.215-1 of Section 00 21 00. : Date of Receiving Proposals:
16 AUG 2018
Amendment No. 0002
3 AUG 2018
SUBJECT: Amendment No. 0002 to Request for Proposal Solicitation Package for Design and Construction of AMMUNITION SUPPLY POINT.
TO: Prospective Offerors and Others Concerned
1. The specifications and drawings for subject project are hereby modified as follows (revise all specification indices, attachment lists, and drawing indices accordingly).
a. Specifications. (Descriptive Changes) NONE
b. Specifications (New and/or Revised and Reissued). Delete and substitute or add specification pages as noted below. The substituted pages are revised and reissued with this Amendment.
Pages Deleted Pages Substituted or Added 08 14 00 12 50 00.13
15 50 00.13AT – FF&E PACKAGE
c. Drawings (Reissued). The following drawing(s) are revised with a revision date as indicated in the title block, and reissued with this amendment.
(1) Sheet CS112A, SITE PLAN – AREA 12A
(2) Sheet A-400AS, AMMUNITION STOREHOUSE BUILDING – WALL
SECTIONS
(3) Sheet A-600AS, AMMUNITION STOREHOUSE BUILDING – ROOM
FINSIH SCHEDULE AND DOOR SCHEDULE
(4) Sheet A-701AS, AMMUNITION STOREHOUSE BUILDING – DOOR AND
WINDOW DETAILS
(5) Sheet EP601, ELECTRICAL ONE-LINE
2. This amendment is a part of the proposing papers and its receipt shall be acknowledged on the Standard Form 1442. All other conditions and requirements of the request for proposal remain unchanged. If the proposals have been mailed prior to receiving this amendment, you will notify the office where proposals are received, in the specified manner, immediately of its receipt and of any changes in your proposal thereby occasioned.
Electronic Proposals shall be delivered via AMRDEC Safe Access File Exchange (SAFE), https://safe.amrdec.army.mil/, to the USACE Contracting Activity at the following email addresses:
Am #0002 - 3 (Continuation of SF30)
Stephanie.A.Harr@usace.army.mil and Christine.L.Wilson@usace.army.mil
3. Offers will be received until 2:00 p.m, local time at place of receiving proposals, 16 AUG 2018.
Attachments:
Site Visit Sign-In Roster, For Information Only Specification Pages listed in 1.b., above Drawings listed in 1.c., above
U.S. Army Corps of Engineers, Omaha District 1616 Capitol Avenue Omaha, Nebraska 68102-4901
03 AUG 2018
NEP/2160
This page was intentionally left blank for duplex printing.
Am #0002
Am #0002
Ammunition Supply Point PN73375 (FY18) - Fort Carson, CO FCBN
SECTION TABLE OF CONTENTS
DIVISION 08 - OPENINGS
SECTION 08 14 00
WOOD DOORS
08/16
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 DELIVERY, STORAGE, AND HANDLING
1.4 WARRANTY
PART 2 PRODUCTS
2.1 DOORS
2.1.1 Flush Doors
2.1.1.1 Interior Flush Doors
2.1.2 Acoustical Doors
2.1.3 Fire Doors
2.2 ACCESSORIES
2.2.1 Door Light Openings
2.2.2 Additional Hardware Reinforcement
2.3 FABRICATION
2.3.1 Marking
2.3.2 Quality and Construction
2.3.3 Preservative Treatment
2.3.4 Adhesives and Bonds
2.3.5 Prefitting
2.3.6 Finishes
2.3.6.1 Factory Finish
2.3.6.2 Color
2.3.7 Water-Resistant Sealer
2.4 SOURCE QUALITY CONTROL
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Fire Doors
-- End of Section Table of Contents --
SECTION 08 14 00 Page 1Am #0002
SECTION 08 14 00
WOOD DOORS
08/16
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
ARCHITECTURAL WOODWORK INSTITUTE (AWI)
AWI AWS (2nd Edition) Architectural Woodwork Standards
ASTM INTERNATIONAL (ASTM)
ASTM E2226 (2015a) Standard Practice for Application of Hose Stream
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies
NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives
UNDERWRITERS LABORATORIES (UL)
UL 10B (2008; Reprint Feb 2015) Fire Tests of Door Assemblies
WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)
ANSI/WDMA I.S.1A (2013) Interior Architectural Wood Flush Doors
ANSI/WDMA I.S.6A (2013) Interior Architectural Stile and Rail Doors
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Doors; G, DO
SECTION 08 14 00 Page 2Am #0002
Submit drawings or catalog data showing each type of door unit ;
include descriptive data of head and jamb weatherstripping with installation instructions. Indicate within drawings and data the door types and construction, sizes, thickness, methods of assembly, and glazing,.
SD-03 Product Data
Doors; G, DO
Accessories
Water-resistant Sealer
Sample Warranty
Sound Transmission Class Rating; G, DO
Fire Resistance Rating; G, DO
SD-04 Samples
Doors
Prior to the delivery of wood doors, submit a sample section of each type of door which shows the stile, rail, veneer, finish, and core construction.
Door Finish Colors; G, DO
Submit a minimum of three color selection samples , minimum 3 by 5 inches in size representing wood stain.
SD-06 Test Reports
Cycle-Slam
Hinge Loading Resistance
Submit cycle-slam test report for doors tested in accordance with ANSI/WDMA I.S.1A, and hinge loading resistance test report for doors tested in accordance with ANSI/WDMA I.S.6A.
1.3 DELIVERY, STORAGE, AND HANDLING
Deliver doors to the site in an undamaged condition and protect against damage and dampness. Stack doors flat under cover. Support on blocking, a minimum of 4 inch thick, located at each end and at the midpoint of the door. Store doors in a well-ventilated building so that they will not be exposed to excessive moisture, heat, dryness, direct sunlight, or extreme changes of temperature and humidity. Do not store in a building under construction until concrete, masonry work, and plaster are dry. Replace defective or damaged doors with new ones.
1.4 WARRANTY
Warrant doors free of defects as set forth in the door manufacturer's standard door warranty.
SECTION 08 14 00 Page 3Am #0002
PART 2 PRODUCTS
2.1 DOORS
Provide doors of the types, sizes, and designs indicated free of urea-formaldehyde resins.
2.1.1 Flush Doors
Conform to ANSI/WDMA I.S.1A for flush doors. Provide hollow core doors with lock blocks and 1 inch minimum thickness hinge stile. Hardwood stile edge bands of doors receives a natural finish, compatible with face veneer.
Provide mill option for stile edge of doors scheduled to be painted. No visible finger joints will be accepted in stile edge bands. When used, locate finger-joints under hardware.
2.1.1.1 Interior Flush Doors
Provide particleboard core, Type II flush doors conforming to ANSI/WDMA I.S.1A with faces of select premium white birch. Hardwood veneers must be plain sliced book matched.
2.1.2 Acoustical Doors
ANSI/WDMA I.S.1A, solid core. Offices and restroom doors shall be STC 33 doors according to door manufacturers' product data literature.
2.1.3 Fire Doors
Provide doors specified or indicated to have a fire resistance rating conforming to the requirements of UL 10B, ASTM E2226, or NFPA 252 for the class of door indicated. Affix a permanent metal label with raised or incised markings indicating testing agency's name and approved hourly fire rating to hinge edge of each door.
2.2 ACCESSORIES
2.2.1 Door Light Openings
Provide glazed openings with the manufacturer's standard wood moldings.
Provide moldings for doors to receive natural finish of the same wood species and color as the wood face veneers. Lip type moldings for flush doors.
2.2.2 Additional Hardware Reinforcement
Provide the minimum lock blocks to secure the specified hardware. The measurement of top, bottom, and intermediate rail blocks are a minimum 125 mm 5 inch by full core width. Comply with the manufacturer's labeling requirements for reinforcement blocking, but not mineral material similar to the core.
2.3 FABRICATION
2.3.1 Marking
Stamp each door with a brand, stamp, or other identifying mark indicating quality and construction of the door.
SECTION 08 14 00 Page 4Am #0002
2.3.2 Quality and Construction
Identify the standard on which the construction of the door was based , identify the standard under which preservative treatment was made, and identify doors having a Type I glue bond.
2.3.3 Preservative Treatment
Treat doors scheduled for restrooms, janitor closets and other possible wet locations including exterior doors with a water-repellent preservative treatment and so marketed at the manufacturer's plant.
2.3.4 Adhesives and Bonds
ANSI/WDMA I.S.1A. Use Type I bond for exterior doors and Type II bond for interior doors. Provide a nonstaining adhesive on doors with a natural finish.
2.3.5 Prefitting
Provide factory finished and factory prefitted doors for the specified hardware, door frame and door-swing indicated. Machine and size doors at the factory by the door manufacturer in accordance with the standards under which the doors are produced and manufactured. The work includes sizing, beveling edges, mortising, and drilling for hardware and providing necessary beaded openings for glass and louvers. Provide the door manufacturer with the necessary hardware samples, and frame and hardware schedules to coordinate the work.
2.3.6 Finishes
2.3.6.1 Factory Finish
Provide doors finished at the factory by the door manufacturer as follows:
AWI AWS Section 1500, specification for System No. 4 Conversion varnish alkyd urea or System No. 5 Vinyl catalyzed. The coating is AWI AWS premium, medium rubbed sheen, open grain effect. Use stain when required to produce the finish specified for color. Seal edges, cutouts, trim, and wood accessories, and apply two coats of finish compatible with the door face finish. Touch-up finishes that are scratched or marred, or where exposed fastener holes are filled, in accordance with the door manufacturer's instructions. Match color and sheen of factory finish using materials compatible for field application.
2.3.6.2 Color
Provide door finish colors in accordance with Section 09 06 00 SCHEDULES
FOR FINISHES.
2.3.7 Water-Resistant Sealer
Provide manufacturer's standard water-resistant sealer compatible with the specified finishes.
2.4 SOURCE QUALITY CONTROL
Meet or exceed the following minimum performance criteria of stiles of "B" and "C" label fire doors utilizing standard mortise leaf hinges:
SECTION 08 14 00 Page 5Am #0002
a. Cycle-slam: Heavy Duty Doors: 500,000 cycles with no loose hinge screws or other visible signs of failure when tested in accordance with the requirements of ANSI/WDMA I.S.1A .
b. Hinge loading resistance: Averages of ten test samples not less than Heavy Duty doors: 475 pounds force when tested for direct screw withdrawal in accordance with ANSI/WDMA I.S.6A using a No. 12, 1-1/4 inch long, steel, fully threaded wood screw. Drill 5/32 inch pilot hole, use 1-1/2 inch opening around screw for bearing surface, and engage screw full, except for last 1/8 inch. Do not use a steel plate to reinforce screw area.
PART 3 EXECUTION
3.1 INSTALLATION
Do not install building construction materials that show visual evidence of biological growth.
Before installation, seal top and bottom edges of doors with the approved water-resistant sealer. Seal cuts made on the job immediately after cutting using approved water-resistant sealer. Fit, trim, and hang doors with a 1/16 inch minimum, 1/8 inch maximum clearance at sides and top, and a 3/16 inch minimum, 1/4 inch maximum clearance over thresholds. Provide 3/8 inch minimum, 7/16 inch maximum clearance at bottom where no threshold occurs. Bevel edges of doors at the rate of 1/8 inch in 2 inch. Door warp must not exceed 1/4 inch when measured in accordance with ANSI/WDMA I.S.1A.
3.1.1 Fire Doors
Install fire doors in accordance with NFPA 80. Do not paint over labels.
-- End of Section --
SECTION 08 14 00 Page 6Am #0002
SECTION TABLE OF CONTENTS
DIVISION 12 - FURNISHINGS
SECTION 12 50 00.13 10
FURNITURE AND FURNITURE INSTALLATION
08/17
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SERVICES
1.4 FURNITURE PURCHASE
1.5 ALTERNATE DESIGN
1.5.1 Desk and Workstation Size and Configuration
1.5.2 Filing and Storage Size and Configuration
1.5.3 Furniture Requirements
1.5.4 Layout
1.6 AUTHORIZED DEALER, CERTIFIED FURNITURE INSTALLERS, LICENSED
ELECTRICIAN AND CERTIFIED TELECOMMUNICATIONS INSTALLER
1.7 DELIVERY, STORAGE AND HANDLING
1.7.1 Delivery
1.7.2 Furniture Inspection
1.7.3 Storage
1.7.4 Furniture Staging Area
1.8 WARRANTY
PART 2 PRODUCTS
2.1 REFERENCE TO MANUFACTURER NAMES AND COLORS
2.2 FURNITURE REQUIREMENTS
2.2.1 Construction
2.2.2 Locks and Keying
2.2.3 Receptacle Bodies and Device Cover Plates
2.2.4 Fabric and Finish
2.2.4.1 Fabric
2.2.4.2 Finishes
2.3 FURNITURE LAYOUT
PART 3 EXECUTION
3.1 BUILDING EXAMINATION
3.2 BUILDING PROTECTION
3.3 INSTALLATION
3.3.1 Installation Drawings
3.3.2 Furniture Installation Procedures
3.4 CLEANING
3.5 OPERATION AND MAINTENANCE MANUALS
3.5.1 Assembly Manuals
3.5.2 Installation Instructions
3.5.3 Maintenance Manuals
3.5.4 Electrical System Manuals
3.5.5 Special Tools
SECTION 12 50 00.13 10 Page 1Am #0002
3.5.6 Furniture Drawings
3.5.7 Furniture Listing
3.5.8 Order Form Documentation
ATTACHMENTS:
Furniture, Fixtures and Equipment(FF&E) Package
-- End of Section Table of Contents --
SECTION 12 50 00.13 10 Page 2Am #0002
SECTION 12 50 00.13 10
FURNITURE AND FURNITURE INSTALLATION
08/17
PART 1 GENERAL
Purchase and install furniture as identified within this specification.
This specification section includes a Furniture, Fixtures and Equipment(FF&E) Package attachment.
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM D4157 (2013; R 2017) Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA X5.1 (2017) American National Standards For Office Furnishings - General Purpose Office Chairs
ANSI/BIFMA X5.3 (2007; R2012) American National Standards For Office Furnishings - Vertical Files
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.9 (2012) American National Standards For Office Furnishings - Storage Units
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2018; TIA 18-1) Life Safety Code
NFPA 260 (2013) Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture
SECTION 12 50 00.13 10 Page 3Am #0002
STATE OF CALIFORNIA DEPARTMENT OF CONSUMER AFFAIRS, BUREAU OF
ELECTRICAL AND APPLIANCE REPAIR, HOME FURNISHINGS AND THERMAL
INSULATION (BEARHFTI)
TB 117-2013 (2013) Requirements, Test Procedure and Apparatus for Testing the Smolder Resistance of Materials Used in Upholstered Furniture
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Storage Location
SD-02 Shop Drawings
Installation Drawings; G, DO
Grommet and Power and Communication Units Locations; G, DO
SD-03 Product Data
Product Data; G, DO
SD-04 Samples
Fabric and Finishes; G, DO
SD-07 Certificates
Authorized Dealer
Certified Furniture Installers
Licensed Electrician
Certified Telecommunications Installer
Manufacturer's Certification
Warranty
SD-10 Operation and Maintenance Data
Furniture, Data Package 1
SECTION 12 50 00.13 10 Page 4Am #0002
1.3 SERVICES
Provide services to include furniture purchase, field measuring, installation drawings, shipping and delivery coordination, receiving, inspection, submitting and processing freight and warranty claims, unpacking, storing, assembly, installation and other related activities or tasks for a complete and functional installation. Reference Section 01 45 00.00 10 QUALITY CONTROL for inspection requirements. The Contracting Officer must be allowed to participate in inspections. Develop project timelines and establish shipping, receiving and installation dates that coordinate with the building construction schedule. Hold at a minimum weekly team meetings to brief the project team, include the Contracting Officer. Notify the Contracting Officer immediately of any scheduling problems, discontinued furniture items including fabrics and finishes, or other conditions which may cause delays, and recommend available substitutes, solutions, and provide updated timeline to coordinate with building construction schedule. Substitutes and solutions must comply with the specification and be approved by the Contracting Officer.
1.4 FURNITURE PURCHASE
Purchase furniture, including checking accuracy of all acknowledgements and schedules from manufacturers and making necessary corrections to insure that the manufacturer has a correct understanding of the order and requirement. Purchase furniture from the open market. The furniture provided needs to be available on the GSA Schedules to assist the User with future purchases. GSA information is provided FOR INFORMATIONAL PURPOSES ONLY. It is encouraged to solicit and provide GSA pricing on furniture.
Compete the furniture purchase by obtaining a minimum of (3) separate proposals. Furniture is subject to FAR clause 52.236-5 Materials and Workmanship.
1.5 ALTERNATE DESIGN
When a manufacturer's product is unable to provide desk and workstation configurations and filing/storage that conform exactly to the furniture layouts shown in the contract drawings and specifications, alternate designs may be submitted for consideration by the Government. Alternate designs must meet or exceed the following criteria. Alternate designs that are submitted but do not meet these criteria will be rejected.
1.5.1 Desk and Workstation Size and Configuration
The alternate design must provide desks and workstations of the same basic size and configuration shown, with only the sizes of the individual components within the desk and workstation changed to meet the standard product of the manufacturer.
1.5.2 Filing and Storage Size and Configuration
The alternate design must provide filing and storage of the same basic size and configuration shown, with only the size changed to meet the standard product of the manufacturer. The storage capacity must not be reduced.
1.5.3 Furniture Requirements
The furniture provided must comply with the drawings, specifications, and the requirements identified in the FF&E Package Attachment.
SECTION 12 50 00.13 10 Page 5Am #0002
1.5.4 Layout
The storage capacity, number of desks and workstations, number of persons accommodated, width of aisles, and functionality must be maintained.
Layout must comply with NFPA 101 and 36 CFR 1191.
1.6 AUTHORIZED DEALER, CERTIFIED FURNITURE INSTALLERS, LICENSED ELECTRICIAN
AND CERTIFIED TELECOMMUNICATIONS INSTALLER
When required by the furniture manufacturer, furniture must be installed by an authorized dealer and a certified furniture installation crew must be used on the project. All furniture requiring hardwiring must be completed by a licensed electrician. Communications installers must be Building Industry Consulting Services International (BICSI) Registered Cabling Installers, Technician Level or have a minimum of 3 years experience in the installation of the specified cables and components. All installers, furniture, electrical and communications, must be on-site if questions arise. Submit copies of authorized dealer, furniture installation crew, licensed electrician and certified telecommunications installer certifications.
1.7 DELIVERY, STORAGE AND HANDLING
1.7.1 Delivery
Deliver furniture to the jobsite in manufacturer's original packaging or blanket wrapping. Original packaging must be marked with the manufacturer name, item identification, and project reference clearly marked.
1.7.2 Furniture Inspection
Inspect furniture and provide notification of damage within the time frame required by the shipping company while carrier is still on-site. Complete claims for concealed damage within the time frame required by the shipping company and furniture manufacturer. A claim file must be maintained that documents each claim. Forward copies of claims to the Contracting Officer on a weekly basis.
1.7.3 Storage
Storage space is not available on-site and furniture must be stored at an off site location. Provide any storage space required for furniture and transport stored furniture to the project site for installation. Storage location must be approved by the Contracting Officer at the time of the furniture order. If storage is required, furniture must be stored in a dry location that is adequately ventilated and free from dirt and dust, water, and other contaminants, in a manner that permits easy access for inspection and handling, and in an environment in accordance with furniture manufacturers instructions.
1.7.4 Furniture Staging Area
Coordinate location of the furniture staging area with the Contracting Officer.
1.8 WARRANTY
Provide manufacturer performance guarantees or warranties for single-shift
SECTION 12 50 00.13 10 Page 6Am #0002 service and include parts, labor and transportation as follows, unless otherwise noted:
Desks and Workstations - 12 year minimum
Filing and Storage - 12 year minimum
Seating - 10 year minimum
Tables - 10 year minimum
Miscellaneous
(1) Fabric - 3 year minimum
(2) LED Task Lighting - 5 year minimum
(3) Task Lighting - 3 year minimum
Provide items not listed with a 1 year minimum. When manufacturers standard performance guarantees or warranties exceed the minimum requirements identified, provide the standard performance guarantee or warranty. Submit manufacturer's warranty information for all furniture items.
PART 2 PRODUCTS
2.1 REFERENCE TO MANUFACTURER NAMES AND COLORS
Where product and color is shown as being specific to one manufacturer in the FF&E Package Attachment, an equivalent color or product by another manufacturer may be submitted for approval. Manufacturers, style lines, model numbers, finish, and fabric information are provided to establish design intent and are not intended to limit the selection of equal products and colors from other manufacturers.
2.2 FURNITURE REQUIREMENTS
Use the FF&E Package Attachment in conjunction with the drawings and specifications for the furniture requirements. Provide furniture from manufacturer's standard product as shown in the most current published price list or amendment. Furniture provided must be part of current line as indicated with no intent to discontinue within two years. Provide furniture that is intended for commercial use, not residential. Submit product data for all furniture items, to include catalog cuts, brochures, product information, and other necessary literature to indicate compliance with specifications. Provide product data for all items together in a single submittal. When applicable, include GSA schedule information to confirm that items are available on GSA schedule. Tag product data sheets with applicable furniture item code and name. Submit data for all product style options for selection when options are available. This applies to, but is not limited to, furniture items that have options such as edge details, hardware options, and grommet colors. Submit manufacturer's certification stating that furniture meets the specifications.
2.2.1 Construction
a. Provide furniture that complies with the following testing requirements:
SECTION 12 50 00.13 10 Page 7Am #0002
(1) ANSI/BIFMA
Office Seating - ANSI/BIFMA X5.1
Vertical Files - ANSI/BIFMA X5.3
Desk Products - ANSI/BIFMA X5.5
Storage - ANSI/BIFMA X5.9
(2) Flammability
Upholstered furniture must comply with TB 117-2013 or NFPA 260
b. Provide furniture with no rough or sharp edges or exposed connections.
Clips, screws, and other construction elements must be concealed wherever possible.
c. Items such as desks and workstations must include all necessary components to be structurally sound and must not be attached to the wall unless specified to be wall mounted in the contract documents.
d. Desks, workstations, storage, and tables must have leveling devices to compensate for uneven floors.
e. The underside of desks, workstations, and tables must be completely and smoothly finished.
f. The backside of freestanding desks, workstations, and storage must be finished.
g. Provide chair casters and glides appropriate for the floor material they are located on, such as carpet and resilient flooring.
2.2.2 Locks and Keying
a. All drawers and doors, including but not limited to overhead storage cabinets, storage towers, supply cabinets, storage cabinets, desk and workstation pedestals, and filing cabinets must be lockable.
b. Key each desk and workstation in a room differently and key locks within each desk and workstation alike.
c. Furniture storage components in private offices must be keyed alike.
Key each private office differently.
d. Provide field changeable lock cylinders in desks and workstations.
Number keys and lock cylinders for ease of replacement or clearly label locks with a key number, except for those manufacturers who have removable format locks.
e. Drawers within a pedestal must be lockable either by a central lock that controls all pedestals under one work surface or an individual keyed lock in each pedestal.
f. Not Used.
g. Provide two keys for each workstation when components are keyed alike.
Also provide two keys for each miscellaneous item such as filing
SECTION 12 50 00.13 10 Page 8Am #0002 cabinets, supply cabinets, storage cabinets, and similar type furniture items.
h. Provide three copies of each master key to the Contracting Officer.
i. Leave keys in locks.
2.2.3 Receptacle Bodies and Device Cover Plates
Provide color as follows:
a. Faceplate: match panel trim color
b. Receptacle Bodies: match panel trim color
c. Communication Cable Jackets: match receptacle device cover plates in color
2.2.4 Fabric and Finish
Submit samples of all furniture fabric and finishes. Samples must be actual samples, not photographic representations, size must be a minimum of 3 by 3 inches. If necessary, provide larger size samples to clearly represent pattern. Label samples with fabric or finish code, furniture item code and name, manufacturer name, and color information. Include fiber content and double rub testing information.
2.2.4.1 Fabric
a. Fabric must be from manufacturer's standard line and graded-in textile manufacturer's fabrics. Do not provide COM fabrics.
b. Provide a mid grade fabric. Example: manufacturer available grades 1 through 4 (even number of grades) - provide grade 3; manufacturer available grades A through D (even number of grades) - provide grade C; manufacturer available grades A through E (odd number of grades) -provide grade C (middle grade).
c. Provide a topical or inherent soil retardant treatment where indicated.
d. Comply with double rub testing as specified in the FF&E Package Attachment. Perform double rub testing in accordance with the ASTM D4157 Wyzenbeek Method.
e. Provide vinyl, polypropylene or similar type fabric for seating only if allowed in FF&E Package Attachment.
f. See FF&E Package Attachment for additional information.
2.2.4.2 Finishes
Provide furniture finishes as listed below unless otherwise noted:
a. Finishes must be able to be cleaned with ordinary household cleaning solutions. Wood finishes must be able to be cleaned with damp cloth as directed by the manufacturer.
b. The finish of steel surfaces must be the manufacturer's most durable finish such as factory powder coat or baked enamel.
SECTION 12 50 00.13 10 Page 9Am #0002
c. Grommet colors must be compatible and coordinated with desk, workstation, and table finish colors.
e. Plastic laminate worksurfaces and table tops must be neutral in color and must have a pattern to help hide soiling.
f. See FF&E Package Attachment for additional information.
2.3 FURNITURE LAYOUT
Provide furniture layout as indicated in the drawings.
PART 3 EXECUTION
3.1 BUILDING EXAMINATION
Become familiar with details of the work, inspect all areas and conditions under which furniture is to be installed, and coordinate scheduling of dedicated elevators and docks. Notify the Contracting Officer in writing of any conditions detrimental to the proper and timely completion of the installation. Work will proceed only when conditions have been corrected.
3.2 BUILDING PROTECTION
Protect building surfaces to prevent soiling and damage during delivery and installation. Any soiling and damage that occurs to the building during the installation of furniture must be cleaned and repaired, or replaced to its original condition and must be approved by the Contracting Officer.
3.3 INSTALLATION
3.3.1 Installation Drawings
Installation drawings must include furniture layout, critical dimensions and locations of electrical and communications. Furniture layouts shall reflect field verified conditions. Drawings must be at 1/4 inch = 1 foot scale, unless otherwise specified. Provide typical plans and isometrics/elevations of desks and workstations at a scale of 1/2 inch = 1 foot. When applicable, provide desk and workstation electrical and communications locations. When applicable include controlled-circuit identification for each furniture receptacle and coordinate with the building electrical system circuits in accordance with ASHRAE 90.1 - IP.
Critical dimensions include, but are not limited to clearances and aisle widths. Drawings must include layout for furniture systems workstations for coordination purposes. Label furniture with furniture item code identified in this specification. Submit grommet and power and communication units locations.
3.3.2 Furniture Installation Procedures
Complete installation in accordance with manufacturer's installation instructions, assembly manuals, warranty requirements and approved installation drawings. Also comply with the following requirements:
a. Use material handling equipment with rubber wheels.
b. Furniture and components must be installed level, plumb, square, and with proper alignment with adjoining furniture.
SECTION 12 50 00.13 10 Page 10Am #0002
c. Match keys to locks and check locking mechanisms.
d. Check drawers, doors, lighting, and other operable items and mechanisms for proper operation.
e. Remove all protective wrapping tape, residue, and related type items.
f. Securely interconnect furniture components where required.
g. Securely attach and anchor furniture components to the building when required.
h. Securely anchor furniture such as shelving and storage units to the building when required by the manufacturer.
i. All items with an electrical plug, such as but not limited to task lighting and tables with electrical power, must be fully operational.
j. All furniture must be fully operational. Verify that voltage is present in electrical outlets. Verify controlled-circuit outlets are properly configured in accordance with the installation drawings.
k. Furniture must not block receptacles. Report conflicts to Contracting Officer to discuss resolution.
l. Upon completion of installation, all furniture must be completely cleaned, finished, leveled, aligned, operational and functional.
3.4 CLEANING
Remove all packing materials and other trash from the jobsite. Upon completion of installation, all products must be clean, including inside all drawers and doors, and the area must be free of debris and left in a clean and neat condition. Any defects in or damage to furniture must be repaired or replaced and approved by the Contracting Officer. Damaged products that cannot be satisfactorily repaired must be replaced. Correct any problems with assembly and installation. Prior to any furniture repair, replacement, and/or assembly and installation corrections, protect the building surfaces.
3.5 OPERATION AND MAINTENANCE MANUALS
Submit the Furniture, Data Package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA and include the following:
3.5.1 Assembly Manuals
Describe assembly and re-configuration procedures. Provide three sets of installation video tapes if available.
3.5.2 Installation Instructions
Provide a copy of the instructions used to install the furniture. Also describe any special procedures or helpful hints learned during the installation process.
SECTION 12 50 00.13 10 Page 11Am #0002
3.5.3 Maintenance Manuals
Describe proper cleaning and minor repair procedures, include cleaning instructions for fabrics.
3.5.4 Electrical System Manuals
Describe the functions, configuration, and maintenance of the furniture electrical system (power, communication, and data). This information may be included in the assembly or maintenance manuals.
3.5.5 Special Tools
Provide three sets of special tools necessary for assembly and disassembly of furniture and components from each manufacturer. Mark tool(s) with manufacturer and product information.
3.5.6 Furniture Drawings
Provide hard copy and electronic furniture drawings showing installed furniture layout. Include all modifications. Provide electronic copies on a CD-ROM. Coordinate type (such as but not limited to Microstation, AutoCad and Revit) and version required with User. Include critical dimensions, and locations of building and furniture electrical and communications. Provide drawings at 1/4 inch = 1 foot scale, unless otherwise specified. Provide typical plans and isometrics/elevations of workstations at a scale of 1/2 inch = 1 foot. Code all furniture with furniture item code identified in this specification.
3.5.7 Furniture Listing
Provide complete furniture listing, hard copy and electronic, of furniture provided. Include all modifications. Provide electronic copies on a CD-ROM. Coordinate type of electronic file required with User (such as but not limited to Word and Excel). Listing must include furniture item code and name used in FF&E Package, part/model numbers, fabrics and finishes for all components furnished. Organize listing by item name and code and provide building totals.
3.5.8 Order Form Documentation
Provide Order Form Documentation with Purchase Order number and project name and location to allow the User to follow up on warranty issues and to assist with future purchases.
-- End of Section --
SECTION 12 50 00.13 10 Page 12Am #0002
AMMUNITION SUPPLY POINT
Ft. Carson, CO
Furniture, Fixtures & Equipment Package
Ammunition Supply Point
INDEX
Narrative
Item Code Legend
Alternate Manufacturer List
Data Sheets
See Sheets I-110AS and I-110RE in the Drawings
See UFGS SECTION 12 50 00.13.10
FURNITURE AND FURNTITURE INSTALLATION
in the Specifictions
NARRATIVE
1. FURNITURE DESIGN AND PROCUREMENT. The Furniture, Fixtures and Equipment (FF&E) package for this project has been specified from the GSA schedules. The office furniture include items such as desks, seating, appliances, tables and storage items. These items will be purchased and installed by the contractor as a bid option to the contract. Refer to UFGS 12 50 00.13 10 FURNITURE AND FURNITURE INSTALLATION for specifications and shop drawing requirements.
2. GENERAL. The intent of the FF&E design is to provide aesthetically pleasing, comfortable, functional and easily maintainable furniture for personnel. The FF&E design has been developed to coordinate with the building design to include the SID color scheme, architectural floor plan and features, and building systems such as location of power and communications.
3. FABRICS AND FINISHES. The furniture finishes and upholsteries coordinate with and complement the building finishes and colors. Soiling of and maintainability of fabric and finishes were considered during fabric selection.
Finishes are appropriate for their intended use in the facilities.
4. FURNITURE. Furniture provided in private offices includes woodgrain plastic laminate L-shaped desks of metal construction, task chair, two guest chairs and a lateral file cabinet. Open office workstations contain L-shaped freestanding desks with a task chair. Break Rooms have been provided with rectangular tables so they can be easily reconfigured, and plastic shell chairs. Miscellaneous storage units are provided in the Print/Storage rooms and Processing in the Ammunition Storehouse.
5. QUESTIONS. Direct Any questions on the FF&E Package to:
Interior Designer: Jane Ann Carter, Jane.A.Carter@usace.army.mil, (402) 995-2152
OR
Project Manager: Jeff Tessin, Jeff.D.Tessin@usace.army.mil, (402) 995-2773
ITEM CODE LEGEND
ITEM
CODE
A - ACCESSORIES
A1 Trash Receptacle
A2 Large Trash Receptacle
A3
D - DESKS
D1
D2
F - STORAGE
F1 F2 F3 Open Shelving
F4 5-Drawer Lateral File
F5 Storage Tower
M - MISCELLANEOUS EQUIPMENT
M1
M2
S - SEATING
S1 Chair, Desk
S2 Chair, Side
S3
T - TABLES
T1
T2
T3
Table, Break, 60x36
Table, Break, 48x30
Refrigerator
Microwave
Chair, Break
Table, Work
Storage Cabinet
ITEM NAME
Recycling Center
L-Desk, Private Office
L-Desk, Open Office
Office Supply Cabinet
Annunition Supply Point
ALTERNATE MANUFACTURER LIST
ITEM CODE ITEM NAME SPECIFIED PRODUCT ALTERNATE A ALTERNATE B
D-Series Desks Herman Miller - Canvas Haworth - Compose and X-Series
Steelcase - Answer and Kick
F-Series Office Storage
Herman Miller - Canvas and Tu
Haworth - Compose and X- Series
Steelcase - Answer and Universal
S1 Desk Chair Herman Miller - Aeron Haworth ‐ Fern Steelcase ‐ Leap
DATA SHEET
ITEM NAME: #REF! ITEM CODE: #REF!
MANUFACTURER: Newel Rubbermaid Commercail
CONTRACTOR: American Hotel Register Company
CONTRACT #: GS-07F-0294K
CONTRACT EXP: 4/30/2020
FSC GROUP: 73
SIN: 302 2
PRODUCT NAME: Rubbermaid Rectangular Wastebasket
PRODUCT #: S5R2956-BLK
DIMENSIONS: 14 3/8"w x 10 1/4"d x 15"h
FINISH: Black
UPHOLSTERY: n/a
ROOM LOCATION: Room # Room Name Quantity
102AS Processing 3
109AS Open Office 1
111AS Office 1
112AS Office 1
113AS Office 1
114AS Office 1
115AS Print/Stor 1
116AS Office 1
118AS Office 1
102RE Office 1
103RE Office 1
104RE Print/Stor 1
105RE Office 1
DESCRIPTION: Provide waste receptacle with:
-soft radius corners -rolled edges -dent and crush resistant -leak proof -28 Qt
106RE Office 1
107RE Office 1
TOTAL QUANTITY: 17
ITEM NAME: Large Trash Receptacle ITEM CODE: A2
MANUFACTURER: Glaro
CONTRACTOR: Capitol Supply Co.
CONTRACT #: GS-06F-0070R
CONTRACT EXP: 8/7/2020
FSC GROUP: 51V
SIN: 105 002
PRODUCT NAME: New Yorker WasteMaster Collection
PRODUCT #: F6MF1533SA
DIMENSIONS: 15" Diameter x 33"h; 16 gallon capacity
FINISH: Stainless Steel
UPHOLSTERY: n/a
ROOM LOCATION: Room # Room Name Quantity
117AS Break Room 1
108RE Break Room 1
TOTAL QUANTITY: 2
DESCRIPTION: Provide large trash receptacle with:
-funnel top with 9" opening -16 gallon capacity -construction of heavy-gauge seamless satin aluminum with protective powdercoat finish -galvanized steel inner container with lift out handles and non-corrosive aluminim bottom -finish that does not require polishing and will not rust or tarnish
ITEM NAME: Recycling Center ITEM CODE: A3
MANUFACTURER: Rubbermaid
CONTRACTOR: W.W. Grainger, Inc.
CONTRACT #: GS-06F-0007J
CONTRACT EXP: 2/1/2019
FSC GROUP: 51V
SIN: 105 002
PRODUCT NAME: Configure
PRODUCT #: Manufacturer Part No. 1961781
DIMENSIONS: 38"w x 20"d x 38"h
FINISH: Stainless Steel
UPHOLSTERY: n/a
ROOM LOCATION: Room # Room Name Quantity
117AS Break Room 1
108RE Break Room 1
TOTAL QUANTITY: 2
DESCRIPTION: Provide freestanding recycling center with:
-stainless steel front, sides and back -plastic liners -consists of two units, both with open top configuration; one for 15 gallon trash for landfill and the other for 33 gallon mixed recycling -standard labels and openings for: Landfill and Mixed Recycling -containers connect for easy alignment -units each have a door to access and remove contents
ITEM NAME: L-Desk, Private Office ITEM CODE: D1
MANUFACTURER: Herman Miller, Inc.
CONTRACTOR: Herman Miller, Inc.
CONTRACT #: GS-03F-036DA
CONTRACT EXP: 12/20/2020
FSC GROUP: 71
SIN: 711 1
PRODUCT NAME: Canvas
PRODUCT #: Varies, see description for more information.
DIMENSIONS:
FINISH:
UPHOLSTERY: n/a
Note: Full length modesty panel at primary worksurface not shown
Primary Worksurface - 72"w x 30"d x 28.5"h, Return - 42"w x 24"d x 28.5"h, Overhead - 72"w x 14 3/4"d x 39 1/2"h
Steel Paint: WN Warm Grey Neutral; Plastic Laminate Top: LBJ Graphite Twill;
Tackboard Fabric: Twist, 8R15 Tin (Price Category 2, Medium Grade, 200,000 Wyzenbeek Double Rubs, minimum 100,000 required)
DESCRIPTION: Provide L-shaped freestanding workstation with:
-workstations and accompanying office storage provided from a single manufacturer and from compatible style lines -pedestals of steel construction -high pressure laminate worksurface; plastic laminate self edge is not acceptable -overhead storage of high pressure laminate finish or steel construction with approximate 17 1/4" clearance between underside of overhead storage and worksurface -attached arch style exterior pull for doors and drawers with brushed nickel finish -b/b/f pedestal and pencil drawer at primary worksurface -f/f pedestal and overhead storage with doors, tackboard and full width LED tasklight at return -feature such as gap or grommet at back side of desk and/or overhead to allow cords to extend below the desk to be plugged into a wall outlet -power unit attached to desktop with 2 power outlets and minimum 10' cord -full modesty panel panel at primary worksurface for privacy, modesty panels are not required at walls; if provided at walls modesty panels shall allow access to wall electrical and communication outlets -lockable storage; storage in workstations shall be keyed alike, but each workstation to be keyed differently -components are not to be mounted to the building walls
SEE DRAWINGS FOR HAND OF DESKS, HAND VARIES DEPENDENT ON LOCATION.
ITEM NAME: L-Desk, Private Office ITEM CODE: D1
ROOM LOCATION: Room # Room Name Quantity
111AS Office 1
112AS Office 1
113AS Office 1
114AS Office 1
116AS Office 1
118AS Office 1 102RE Office 1
103RE Office 1
105RE Office 1
106RE Office 1
107RE Office 1
TOTAL QUANTITY: 11
ITEM NAME: L-Desk, Open Office ITEM CODE: D2
MANUFACTURER: Herman Miller, Inc.
CONTRACTOR: Herman Miller, Inc.
CONTRACT #: GS-03F-036DA
CONTRACT EXP: 12/20/2020
FSC GROUP: 71
SIN: 711 1
PRODUCT NAME: Canvas
PRODUCT #: Varies, see description for more information.
DIMENSIONS:
FINISH:
UPHOLSTERY: n/a
Note: Full length modesty panel at primary worksurface not shown
Primary Worksurface - 72"w x 30"d x 28.5"h, Return - 42"w x 24"d x 28.5"h, Overhead - 72" w x 14 3/4"d x 39 1/2"h
Steel Paint: WN Warm Grey Neutral; Plastic Laminate Top: LBQ White Twill; Tackboard Fabric: Twist, 8R15 Tin (Price Category 2, Medium Grade, 200,000 Wyzenbeek Double Rubs, minimum 100,000 required)
DESCRIPTION: Provide L-shaped freestanding workstation with:
-workstations and accompanying office storage provided from a single manufacturer and from compatible style lines -pedestals of steel construction -high pressure laminate worksurface; plastic laminate self edge is not acceptable -overhead storage of high pressure laminate finish or steel construction with approximate 17 1/4" clearance between underside of overhead storage and worksurface -attached arch style exterior pull for doors and drawers with brushed nickel finish -b/b/f pedestal and pencil drawer at primary worksurface -f/f pedestal and overhead storage with doors, tackboard and full width LED tasklight at return -feature such as gap or grommet at back side of desk and/or overhead to allow cords to extend below the desk to be plugged into a wall outlet -power unit attached to desktop with 2 power outlets and minimum 10' cord -full modesty panel panel at primary worksurface for privacy, modesty panels are not required at walls; if provided at walls modesty panels shall allow access to wall electrical and communication outlets -lockable storage; storage in workstations shall be keyed alike, but each workstation to be keyed differently -components are not to be mounted to the building walls
SEE DRAWINGS FOR HAND OF DESKS, HAND VARIES DEPENDENT ON LOCATION.
ITEM NAME: L-Desk, Open Office ITEM CODE: D2
#NAME?
ROOM LOCATION: Room # Room Name Quantity
102AS Processing 2
109AS Open Office 1
TOTAL QUANTITY: 3
ITEM NAME: Office Supply Cabinet ITEM CODE: F1
MANUFACTURER: Herman Miller, Inc.
CONTRACTOR: Herman Miller, Inc.
CONTRACT #: GS-03F-036DA
CONTRACT EXP: 12/20/2020
FSC GROUP: 71
SIN: 711 3
PRODUCT NAME: Tu
PRODUCT #: LQ400.3638 and LTPL-03620
DIMENSIONS: 36"w x 20"d x 39 1/4"h
FINISH:
UPHOLSTERY: n/a
ROOM LOCATION: Room # Room Name Quantity
115AS Print/Stor. 2 104RE Print/Stor. 2
TOTAL QUANTITY: 4
Note: Cabinet is 38" high with high pressure laminate top
Steel Paint: WN Warm Grey Neutral; Plastic Laminate Top: LGQ White Twill
DESCRIPTION: Provide office supply cabinet with:
-workstations and accompanying office storage provided from a single manufacturer and from compatible style lines -steel construction with high pressure laminate top -attached arch style exterior pull for doors with brushed nickel finish -lockable doors -2 adjustable shelves that adjust on 1 1/4" increments
ITEM NAME: Storage Cabinet ITEM CODE: F2
MANUFACTURER: Herman Miller, Inc.
CONTRACTOR: Herman Miller, Inc.
CONTRACT #: GS-03F-036DA
CONTRACT EXP: 12/20/2020
FSC GROUP: 71
SIN: 711 3
PRODUCT NAME: Tu
PRODUCT #: LQ400.3638 and LTPL-03620
DIMENSIONS: 36"w x 20"d x 69"h
FINISH:
UPHOLSTERY: n/a
ROOM LOCATION: Room # Room Name Quantity
102AS Processing 2
TOTAL QUANTITY: 2
Steel Paint: WN Warm Grey Neutral
DESCRIPTION: Provide office supply cabinet with:
-workstations and accompanying office storage provided from a single manufacturer and from compatible style lines -steel construction -attached arch style exterior pull for doors with brushed nickel finish -lockable doors -3 adjustable shelves that adjust on 1 1/4" increments
ITEM NAME: Open Shelving ITEM CODE: F3
MANUFACTURER: Lyon
CONTRACTOR: Lyon LLC
CONTRACT #: GS-27F-035DA
CONTRACT EXP: 9/21/2021
FSC GROUP: 71
SIN: 71 310
PRODUCT NAME: Pre-Engineered 8000 Series Wire Shelving
PRODUCT #: 8006SWS
DIMENSIONS: 36"w x 18"d x 84"h
FI…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.