Am0002_Drawings.pdf
PDF 12 MB Posted
- Attached to
- Big Bend Raw Water Header Replacement Federal contract opportunity
- Solicitation number
- W9128F18B0003
About this file
Amendment 0002 Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9128F18B0006_RAW_WATER_BID_ABSTRACT.pdf | ||
| Site_Visit_Sign-in_8-28-18.pdf | ||
| Final_Site_Visit-Contractor_Safety_Briefing__Information.pdf | ||
| Amendment_0002.pdf | ||
| Amendment_0001.pdf | ||
| REPAIR_RAW_WATER_HEADER,_Dwgs.pdf | ||
| Raw_Water_Specs_August_2018.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg9:04:58 AM 9/5/2018
...\30500 - Construction E&D\BB63\30DA0 - Plans & Specs\CAD_BIM\_Sheets\BB63 - Repair Raw Water Header, Unwatering Valves, Station Dra
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
of Engineers
US Army Corps
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R
M
A H
A
N E
F
IL
E N
A M
E
Omaha District
M
A H
A D
IS
T R
IC
T
F
IL
E N
U M
B E
R
C
A P
IT
O L A
V E
B B
G -0
.d g n
T
A T
IO
N D
R A
IN
A G
E
STATION DRAINAGE
C O
V E
R
S T
A T
IO
N D
R A
IN
A G
E
C O
V E
R
BIG BEND DAM, SOUTH DAKOTA
REPAIR RAW WATER HEADER, UNWATERING VALVES
B
IG
B
E N
D D
A M S
O U
T H D
A K
O T
A
R E
P A
IR
R
A W W
A T
E R H
E A
D E
R
U N
W A
T E
R
IN
G V
A L
V E
S
B
IG
B
E N
D D
A M S
O U
T H D
A K
O T
A
R E
P A
IR
R
A W W
A T
E R H
E A
D E
R
U N
W A
T E
R
IN
G V
A L
V E
S
A N
S I
D
G-001
M
IC
H A
E L T S
M
IT
H P .E
M
H O
F F
M A
N
M
H O
F F
M A
N
M S
M
IT
H
B B
D -0
AUGUST 2018
A U
G U
S T
ADVERTISEMENTADVERTISEMENT
W F -1
-B -0
W9128F-18-B-0003
S
E P
A M
G
E N
E R
A L R
E V
IS
IO
N
E
E N
O T
E
C V
R
C V
R
EA. SIDE
6" MIN.
EQUIPMENT DIMENSION
2" CVR.
M
IN
S T
A N
D A
R D
S
P E
R M
F R
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
OR SEALANT
STOPPING COMPOUND
MIN. 1" THICKNESS FIRE
OR SAFING INSULATION
PACKED INTO OPENING
INSULATION FIRMLY
MINERAL WOOL
PIPE
NOT TO SCALE
PIPE PENETRATION THROUGH FLOOR
NOTES:
1. PERFORM GROUND PENETRATING RADAR (GPR) TO LOCATE REINFORCEMENT PRIOR TO
DRILLING HOLE. HOLE SHALL BE LOCATED SUCH THAT DRILLING AVOIDS EXISTING
REINFORCEMENT AND BEAMS. DRILL HOLE LOCATIONS SHALL BE APPROVED BY THE
CONTRACTING OFFICER PRIOR TO DRILLING HOLES.
2. CORE DRILL A 4" HOLE FOR 3" DIAMETER PIPES AND 7" HOLE FOR 6" DIAMETER PIPE. CORE DRILL
SIZES FOR VALVE STEMS SHALL BE OF A SIZE TO PROVIDE A HOLE THAT IS APPROXIMATELY 1"
LARGER IN DIAMETER THEN THE VALVE STEM SIZE. SUBMIT CORE DRILLING METHODS TO THE
GOVERNMENT FOR APPROVAL.
3. SEE SPECIFICATION SECTION 07 84 00 "FIRESTOPPING" FOR ADDITIONAL REQUIREMENTS
RELATING TO PIPE PENETRATION MATERIALS.
4. THE FLOOR WAS MEASURED TO BE 11" THICK. RECORD DRAWINGS SHOW THAT THE SLAB IS 8"
THICK, WHICH APPEARS TO BE INCORRECT.
3. SAW CUT EXISTING EQUIPMENT PAD DOWELS AT THE SLAB SURFACE.
REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.
EXISTING CONCRETE SLAB. ANY DAMAGE TO THE EXISTING SLAB SHALL BE
2. REMOVE EXISTING CONCRETE PADS WITHOUT CAUSING DAMAGE TO THE
REQUIREMENTS.
1. SEE SPECIFICATION SECTION 03 01 32 CONCRETE REMOVAL FOR ADDITIONAL
CONCRETE PAD DEMOLITION NOTES:
12"
CONCRETE EQUIPMENT PAD
NOT TO SCALE
EXISTING SLAB
CONCRETE EQUIPMENT PAD
3/4" CHAMFER, TYP
(SEE NOTE 1)
EMBEDMENT
4" MIN.
#5 @ 12" WITH
#4 @ 12" E.W.
EQUIPMENT SUPPLIER.
PLACEMENT WITH
COORD. SIZE AND
S.S. ANCHOR BOLT.
VARIES
NOTES:
1. DRILL AND EPOXY REINFORCEMENT INTO EXISTING STRUCTURAL SLAB. DRILL HOLE, CLEAN, AND ANCHOR
DOWELS IN ACCORDANCE WITH EPOXY MANUFACTURER'S RECOMMENDATIONS. EPOXY SHALL BE SIKA
ANCHORFIX-1 OR APPROVED EQUAL.
2. SEE SPECIFICATION SECTION 03 30 53 MISCELANEOUS CAST-IN-PLACE CONCRETE FOR CONCRETE
REQUIREMENTS.
3. ANCHOR BOLTS SHALL BE CAST-IN-PLACE AND SHALL NOT BE INSTALLED AFTER CONCRETE IS PLACED.
4. PERFORM GROUND PENETRATING RADAR (GPR) TO LOCATE EXISTING SLAB REINFORCEMENT PRIOR TO
DRILLING HOLE FOR EPOXY REINFORCEMENT. HOLE SHALL BE LOCATED SUCH THAT DRILLING AVOIDS EXISTING
SLAB REINFORCEMENT.
5. CONTRACTOR SHALL SUBMIT THE LOCATION AND SIZE OF THE EQUIPMENT PADS FOR APPROVAL. EQUIPMENT
PAD SIZE AND LOCATION SHALL BE APPROVED PRIOR TO EQUIPMENT PAD CONSTRUCTION.
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:05:56 AM 9/4/2018
...\30500 - Construction E&D\BB63\30DA0 - Plans & Specs\CAD_BIM\_Sheets\BB63 - Repair Raw Water Header, Unwatering Valves, Station Dra
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R
M
A H
A
N E
C
A P
IT
O L A
V E
O M
A H
A D
IS
T R
IC
T
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
S T
A T
IO
N D
R A
IN
A G
E
R E
P A
IR
R
A W W
A T
E R H
E A
D E
R
U N
W A
T E
R
IN
G V
A L
V E
S
B
IG
B
E N
D D
A M S
O U
T H D
A K
O T
A
B B S -0
.d g n
B B S -0
.d g n
S-001
A N
S I
D
W
B O
E C
K
S T
U R
C T
U R
A L D
E T
A
IL
J
O S
B O
R N
J
O S
B O
R N
W
B O
E C
K B
B D
-0
B B
D -0
W F -1
-B -0
A U
G U
S T
S
E P
A
M
G
E N
E R
A L R
E V
IS
IO
N
| BB63G-001 |
| BB63S-001 |
| BB63M-001 reduced |
| BB63M-105 |
| BB63M-107 |
File details come from the government source that posted it.