ST_STEPHEN_100-REF_DWGs_B_Color.pdf
PDF 9 MB Posted
- Attached to
- St Stephen's Fire Protection Federal contract opportunity
- Solicitation number
- W9127818R0084
About this file
Drawing B
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9127818R0084-0002_Bidding_Schedule_Rev_1_ST_Stephen_Fire_Prot.xlsx | XLSX spreadsheet | |
| W9127818R0084-0002_SF30_Bid_Schedule_Revised.pdf | ||
| W9127818R0084-0002_Bidding_Schedule_Rev_1_ST_Stephen_Fire_Prot.pdf | ||
| W9127818R0084-0001_Site_Visit_Change.pdf | ||
| Pics_from_Trip_Report.pdf | ||
| ST_STEPHEN_100_COLOR.PDF | ||
| ST_STEPHEN_100-REF_DWGs_A_Color.pdf | ||
| W9127818R0084_Solicitation_St_Stephen_Fire_Protection.pdf | ||
| ST_STEPHEN_100-REF_DWGs_C_Color.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2" TED
2 1/2"x2"x2 1/2" QBB
2 1/2" QAQ
2 1/2" TED
2 1/2 QBB
2 1/2" TED
2 1/2" QAQ
2" x 1" QAD
2 1/2" QAR
2 1/2" QAQ
1" QAR
1" BGR
B-4
C
BREAKER
OI
L
TRANSF
ER
PUM
P
L
1" B
GR
1" Q
AR
2" x1
QAD
2"x 2"x
1/2 "Q
BB
2" CUA BOR
B-
B -2
B G
R T
Y P F
O R
B-5
B -1
1/ 2" Q
AR
1/ 2" Q
AQ
1/ 2" Q
AD
B1 F
BO
STRAI
NER
1/ 2" C
UA
BO
FI
LL
P
UM
POUT
2" C
UA
BOS
2" C
UA
BO
2" C
UA
TO
2" C
UA
TOS
1/ 2" C
UA
TO
FI
LL
P
UM
POUT
2" T
ED
TYP.
F
OR
2 1 /2" x2 "x2 1/
2"
QBB
1/ 2" T
ED
1/ 2" Q
AQ
1/ 4" Q
AR
2" Q
BB
TYP.
F
OR
1/ 4" B
QR
2" Q
AR 1
1/ 4" U
SYTYP.
F
OR
BLF
TO
STRAI
NER
1/ 2" Q
AR
1/ 2" x1 /4 " Q
AD
1/ 2" C
UA
TOR
T- 5A
T-
1/ 2" T
ED
1/ 2" Q
AQ
1/ 2" Q
BB
1/ 2" T
ED
T-
1/ 2" Q
BB
1/ 2" T
ED
1/ 2" Q
AQ
1/ 2" B
GR
1/ 2" Q
AR
2" x1 1/
2" Q
AD
2" K
RG
2" T
W I
TYP.
F
OR
DETAIL A (PL. PM-57)
C
TRANSF
. O
IL
TRANSF
ER
PUM
P
L
2 1 /2" x2 " Q
AD
1/ 2" Q
AQ
T-
T-
T-
21VAA
1/4" UPD
1/2"x1/4" QAJ
2"x2"x1/2" QBB
2"x1 1/2" QAD
1 1/2" QAR
1 1/2" BGR
TYP. FOR 2
2 1/2" QAQ
2 1/2" TED
2 1/2"x2"x2 1/2" QBB
B-
B-
1/ 2" B
GR
2" x1 /2 " Q
AD
B-
T-
1/ 2" Q
AT
T- 5B
2" Q
AT
2x 1/
QBB
TOTALI
ZI
NG
M
ETE
RS
/2
Q A
T
B-
B -2
B -1
B -9
T -9
T -1
T -2
T-
DETAIL B (PL. PM-58)
1/ 2" C
UA
FROM
C
LO
TANK
3" C
UA
LOR
1/ 2" C
UA
LO
FI
LL
P
UM
POUT
1/ 2" Q
AQ
1/ 2" T
ED
1/ 2" C
UA
1/ 2" C
UA
LOS
2" C
UA
TO
OI
L
PURI
FI
ER
1/ 2" Q
AQ
1/ 2" T
YD
1/ 2" T
ED
3" x2 "x 1/ 2" Q
BB
3" x3 "x 1/ 2" Q
BB
3" T
ED
TYP
FOR
3" x3 "x 1/ 2" Q
BB
1/ 2" T
ED
SV
1/ 2" C
UA
3" Q
AR
2" Q
AR
1/ 2" Q
AQ
3" x1 1/
2" Q
AD
3" Q
BB
3" x3 "x 1/ 2" Q
BB
2 1 /2" Q
AQ
3" C
UA
FROM
D
LO
TANK
3" C
UA
FROM
C
LO
TANK
1/ 2" B
GR
1/ 2" Q
AT
3" x1 /2 " Q
AD
3" T
YD
C
LUB.
O
IL
TRANSF
ER
PUM
P
L
1" B
GR
1 1 /2" x1 " Q
AR
3" x1 1/
2" Q
AD
3" x3 "x 1/ 2" Q
BB
3" K
RG
3"
TW
I
3" K
RG
3" TYD
3" QAQ
TYP. FOR 19
VAA
1/4" UPD
1/2"x1/4" QAJ
3"x1 1/2" QAD
1 1/2" CUA
1 1/2"x1" QAR
1" BGR
/2
Q A
T
/2
B G
R
T O
T A
L
IZ
IN
G
M E
T E
R
3"x2" QAD
L-18
L-5
L-3
L-6
L-11
L-
L-7
L-19
TYP.
F
OR
L-16 L-8
L-15
L-17
L-13
L-14
L-12
DETAIL C (PL. PM-51, 56 & 57 & 49)
STEEL PIPE SIZE
ESCUTCHEON WITH
SET SCREW.
BNF
PIPE
SLEEVE
CONCRETE WALL
ASBESTOS
ROPE PACKING
ESCUTCHCON (TYP)
DETAIL D (PL. PM-57)
A A
B B
C C
HIGH LEVEL
ALARM CONTROL
4" EIN
1/4
SUMP COVER
(2 REQUIRED)
FLOAT GUIDE
4" CAA
EL. 17.0
A-A
45°
12" DIA. BC
STEEL
P 12"x12"x1/2"L
B-B
C-C
1"
2"
ANCHOR BOLT
1 1/2"x3/8" STEEL STRAP
1/4" STEEL HEX. HEAD CAP SCREW.
END FLUSH WITH PIPE I.D.
°1
HEX. HEAD CAP
SCREW (FLOAT STOP)
NOTES
FOR GENERAL NOTES AND LEGEND, SEE PL. PM-1.
FOR PIPING MATERIAL IDENTIFICATION,
SEE PIS. PM-11 & 12.
WASTE 0.1 S.G. 0.87 TO 0.90
REFERENCE DRAWINGS
OIL ROOMS-SHEET 1, PL. PM-56.
OIL ROOMS-SHEET 2, PL. PM-57.
OIL ROOMS-SHEET 3, PL. PM-58.
LUBRICATING OIL SYSTEM-PL. PM-6.
INSULATING OIL SYSTEM-PL. PM-7.
1.
2.
3.
1.
2.
3.
4.
5.
POWERHOUSE-MECHANICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ERECTION BAY-EXPOSED PIPING
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PM
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
BDL
BDL
CWS
SVERDRUP & PARCEL AND ASSOCIATES, INC.
OIL ROOMS-SHEET 4
PM-59
ZONESYMBOL
5D 4D
4A
1B ADDED NOTE 3. (M-17)
ADDED PL. NO. (GR-7)
REVISED DETAIL A 12 MAR 79
4/18/80
4/26/80
M.G.T.
M.G.T.
-10/05/824 5D, 4C CHANGE BACK PRESSURE LINE (R-185)
T-
T-
NONE
6" 1'-9"
4'-6"1'-6" 6'-6"
" 1
D
E
/6
3'-1 31/64"
1'-3"
3'-1 31/64"
/6
3"4 @6"
9"
4'-6"
4'-6" 2'-0"
6' -4 /8
1' -0
/4
2'-9" 1'-9"
1'-0"
6'-4 3/8"
5 @6"
3"
4 @6"
6'-3"
2'-3"
1'-9"
4'-6" 6'-6"
3"
8 1/4"
8 1/4"
3"
"4
3"
C CONTROL
TUBING
L
EL. 17.0'
3/4" QAJ
3/4"x1/4" QAE
(TYP. FOR 5)
EL. 9.0'
V
PIPE STAND (TYP.)
/4
C U
A
C H
A
C A
C EL. -28.0L
C PUMP IMPELLER
EL. -32.3
L
FLOW
12" DHC
C EL. -35.9L
12" BHC
14"x12" KGV
EL. -39.0
BOTTOM OF POWER-
HOUSE, EL. -41.0
14" DHC
12" 0 5' 10'
SECTION THRU SUMP
SCALE: 1/4" = 1'-0"
PUMP MOTOR
1/16" NEOPRENE SEALING GASKETS
D E
40 HP., 1760 RPM
UNWATERING PUMP MOTORS
15HP., 1760 RPM
UNWATERING SUMP
DRAINAGE MOTOR PUMP
1" UPY
1" CHA
1" EEQ
V V
1'-6" 12" EBA
12" ECV
PIPE HANGER
12" EAA
C EL. 2.0L
C EL. -8.0L
SUPPORT BRACKET
FOR VALVE EXTENSION
STEM GUIDE (TYP.)
STA. DRAINAGE
SUMP. IE.-16.0
C EL. -18.0L
DRAINAGE
SUMP DRAIN
L
L
/4
3/16
EL. -18.0
1/4
CUT HOLE TO SUIT PUMPS
18" SLEEVE
30" SLEEVE UNWATERING PUMPS
SUMP DRAINAGE PUMP AND STATION DRAINAGE PUMPS
DETAIL A
NO SCALE
(PL. PM-60)
VALVE FLOOR
STAND SEE
DETAIL B (TYP.)
EL. 18.0'
C EMERGENCY HIGH
WATER LEVEL ALARM
UNWATERING PUMPS
WATER LEVEL CONTROLLER
EL. 13.0
TOP OF PLATFORM
EL. 7.0'
L
TAILRACE, EL. 4.0'
L
C PUMP IMPELLER
EL. -32.3
L
TOP OF PLATFORM, EL. -33.
12" DHC
12" BHC
BOTTOM OF SUMP
EL. -37.0
14"x12" KGV
14" DHC
EL. -37.0
ST4x20. CUT TO
SUIT (TYP. FOR 2)
DRILL AND TAP BLIND FLANGE TO SUIT
PUMP MOTOR MOUNTING BOLTS
BOLTS WITH HEX HEAD AND NUTS
1/4" BENT BAR TO SUIT FLANGE O.D.
EIN SIZE TO SUIT FOR PUMP MOTOR
EJN SIZE TO SUIT FOR PUMP MOTOR
MINIMUM 0.250 WALL THICKNESS
DIAPHRAGM BULB
EL. -33.4
MOUNTING BRACKET.
DETAIL B (PL. PM-60)
6" EIN
6" UKB
VALVE FLOOR STAND
/4
EL. 18.0
SEAL WELD
3" SLEEVE 1/4
DETAIL B
NO SCALE
(PL. PM-60)
A - A
6" CAA
6" EHN
EL. -39.0
14" EJN
1" HDA
TYP FOR 3
/4 "x
/4
Q A
D
1/4" CUA
1" CHA
CA (100)
PLAN-EL. 18.0
6" VENT
PUMP MOTOR SEAL,
SEE DETAIL A (TYP.)
3'-0"x2'-6"
ACCESS
1/4" CUA
(TYP. FOR 5)
3/4" QAJ
3/4"x1/4" QAE
(TYP. FOR 5)
3/4" P . OUTSIDE DIMENSION TO SUIT
FLOORSTAND. DRILL FOR 3" SLEEVE
DRILL 3/4" P TO SUIT
FLOORSTAND MOUNTING BOLTS
1/16" NEOPRENE GASKET
L
L
BOTTOM OF SUMP
EL. -37.0
1" EEQ TYP. FOR 3
C EL. -35.9L
C EL. -34.0L
1" HDA
TYP. FOR 3
1" HDA
TYP. FOR 12
INV. EL. -31.0
SUMP DRAIN
FISH DRAIN, EL. -29.0
L
TO SPIRAL CASE DRAIN
C UNWATERINGL
PUMP #2
UZI
TYP. FOR 9 PLACES
(LOCATE TO
SUIT VALVE)
UZG
TYP. FOR 4 PLACES
(LOCATE TO SUIT VALVE)
ADJUSTABLE EXTENSION
STEM GUIDE. PROVIDE
AT EVERY SUPPORT
BRACKET (TYP. FOR 7)
C UNWATERINGL
SUMP DRAINAGE
MOTOR PUMP
C UNWATERINGL
PUMP #1
3'-0"x3'-0"
EQUIPMENT HATCH
1" CA (100)
6" BHC
6" EIN
6" TWH
6" EIN
6" UKB
6" EHN
6" EAA
1" UPY
LADDER
12" TWH
1" CHA 1" EEQ
12" BHC
LADDER
12" EAA
12" EHN
12" UKB
14" EHA
PLAN-EL. 7.0
12" BHC
1" HDE TYP. FOR 10
HATCH
12" EIN
1" CHA1" UPY 1" EEQ
12" TWH
12" EIN
12" UKB
12" EHN
12" EAA
6" CAA
12"x12"x6" ECP
VALVE EXTENSION
STEM (TYP.)
12" CAA
ADJUSTABLE EXTENSION
STEM GUIDE. PROVIDE
AT EVERY 10'-0" (TYP. FOR 3)
FOR SUPPORT LOCATION
AND DETAILS, SEE
PL. PS-70 & PS-75.
14"x12" EDI
14" CAA
12" EIN
L
TO TAILRACE
5 @6"
UNWATERING SUMP
DRAINAGE PUMP COLUMN
14" KGG
14" KGQ
14" KGG
A A
TUBING FOR EMERGENCY
HIGH WATER LEVEL ALARM
C BUBBLER TUBE SUMP LEVEL
L
L
C
DRAFT TUBE WATER
LEVEL SENSING LINES
4 @6"
14" EIN
(TYP. FOR 10)
14" EIN (TYP.)
14" UKB
(TYP. FOR 6)
6" TWG
6" EIN
6" UKB
14" KGK
14" BMC
6" EIN
6" UKB
10" EIN
10" UKB
1" EEQ
(TYP. FOR 5)
LADDER
PLAN - EL. 37.0
NOTES
1.
2.
FOR GENERAL NOTES AND LEGEND, SEE PL. PM-1.
FOR PIPING MATERIAL IDENTIFICATION, SEE PL. PM-11 & 12.
REFERENCE DRAWINGS
1.
2.
STATION DRAINAGE SUMP, PL. PM-60.
PLAN-EL. 2.0, PL. PM-16.
3.
4.
5.
6.
HANGERS & SUPPORTS, PL. PM-88 & PM-89.
PLAN-EL. 2.0, PL. PS-70.
BASE SLAB SECTIONS & SUMP DETAIL, PL. PS-75.
EMBEDDED PIPING: PLS. PM-16 & 18.
L
PUMP COLUMN
(FROM UNIT 3)
L
L
STA. DRAINAGE SUMP
L
STA. DRAINAGE SUMP
(FROM UNIT 2)
L
(FROM UNIT 1)
L
DRAIN
L
PUMP COLUMN
L
L
12" 0 2' 4' 6'
SCALE: 3/8" = 1'-0"
POWERHOUSE - MECHANICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ERECTION BAY - EXPOSED PIPING
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PM
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE: 3/8" = 1'-0"
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
ADDED DIMENSION (R-32) (M-14)
CHANGED A-A 16 FEB 79
4/26/80
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
BDL
BDL
HS
SVERDRUP & PARCEL AND ASSOCIATES, INC.
UNWATERING SUMP
PM-61
4A
B-3
M.G.T.
WAM
N
F L
O W
REF. N
KEY PLAN
L
G
2'-6" 3'-5"
1'-4"
1'-9"
C SERVICE
AIR RECEIVER
L
EL. 18.0
C EL. 20.5L
A-A (PL. PM-69)
3"x2" EDL
3" TCD
1/2" TCD
1/2" CHA
C EL. 20.75L
C EL. 22.0L
C EL. 28.0L
3"x1 1/2" HDY
3" HFA
3" CHA
CA (100)
PS-3 (SEE DETAIL A & B)
C EL. 25.5L
1/2" CHA
3" CAAPRW 3" CHA
BOL EL. 28.0
BOL EL. 29.0
EL. 37.0
1 1/2" PRW
1" CA (100)
1" CA (30)
G
EL. 37.0
1'-4"
E-E (PL. PM-69)
F-F (SIMILAR) (PL. PM-70)
MECHANICAL
EQUIPMENT AREA
3" HDI
3" CHACA(100)
3" HDA
C EL. 26.83L
3/4" CHAPRW
3" HFA
3" TCD
C EL. 22.0L
3" HDA
EL. 18.0
SERVICE AIR
COMPRESSOR
C EL. 26.0L
BOL EL. 28.0
AFTERCOOLER
3/4" CHA D
3/4" CHA PRW
AIR INTAKE
FILTER AND SILENCER
I-I (PL. PM-69 & 70)
BOL EL. 29.0
BOL EL. 28.0
C EL. 26.83L
C EL. 26.0L
3" HDA
3" CHACA (100)
3" TCD
3" EKN
MECHANICAL EQUIPMENT AREA
3" HDA
1" CA (300)
3" CA (100) TO AIR COMPRESSOR NO. 2.
EL. 37.0
EL. 18.0
3" HDA
3" TCD
3" HDA
3" EKN
TYP
2 PLACES
3" CHA
CA (100)
3/4" CHA PRW
3/4" PRW TO AIR
COMPRESSOR NO. 2.
C EL. 20.5L
AIR DRYER
TRAP INSTALLATION (TYP.
6 PLACES) DETAIL F
(PI. PM-79)
SERVICE AIR RECEIVER
1 1/2" HDA
BOL
EL. 29.0
3" HDI
3" CHA
3" HFA
3" TCD
TYP.
3" HDA
PLACES
1" CA (30)
1" CA (30)
1 1/2" PRW
VAA
1/2" UPD
1/2" CHA
1/2" HDA
TYP.
PLACES
1 1/4" UST
1 1/4" CHA
1 1/4" HDA
TYP.
PLACES
3" HDA
3" CHA CA (100)
3/4" HDA
3/4" PRW
AFTERCOOLER (TYP)
MOISTURE SEPARATER(TYP)
3/4" CHA (TYP)
3" CA (100) TO AIR
COMPRESSOR NO. 13/4" HDA
3/4" UQE
3/4" BKP
3/4" HDA
3/4" HFA
3/4" TCD
3/4" TLB
TYP
2 PLACES
2"x3/4" HDY
2" HDI
2"x3/4" HDY
1" BCA
(100)
3" PRW
BRAKE AIR
RECEIVER.
SERVICE AIR
RECEIVER.
M-M (PL. PM-67, 69 & 70)
EL. 37.0
MECHANICAL
EQUIPMENT AREA
3/4" HDA
BOL EL. 29.0
BOL EL. 27.0
3/4" CHA
CA (30)
C EL. 20.67L
C EL. 19.0L
EL. 18.0
EL. 4.67
EL. 2.0
STORAGE
AREA
HOSE CONNECTION DETAIL D
(PL. PM-79).
1" CHACA (100)
UNIT 1
1" HDA
1" CHA CA (100)
1" HDA
1" CHA RW (UNITS 1 AND 3)
1" HDI
1" HDA
HOSE CONNECTION
DETAIL D (PL. PM-79)
1" HDA UNIT 2
SLEEVE
1" CHA CA (100) (UNIT 2)
1"x1"x3/4" HDI
3/4" CHA TO PIEZOMETER CONSOLE
3/4" TLB
G
1'-9"
3'-0"
B-B(PL. PM-69)
EL. 37.0
MECHANICAL
EQUIPMENT AREA
BOL EL. 27.0
BOL EL. 29.0
2" CHA
RW (IR)
BOL EL. 27.0
6" CAA
RW
2" CHA
PRW
1 1/2" CHA
EL. 18.0
PRW PUMP
6" EAA
2" CHA
6" ECP
C EL. 20.0L
3" EAA
3" CAA RW
1'-3"
EL. 37.0
G-G (PL. PM-69)
C EL. 26.0L
C EL. 25.0L
1" TXB
1" UQA
C EL. 20.67L
1" CHA
CA (100)
2" RW (IR)
1 1/2" PRW
1 1/4" CA (100)
2" HDA
2" CHA RW (IR)
1 1/2" TCD
1 1/2" CHA
1" CHA
PRW
CA (100)
1" HDA
MECHANICAL
EQUIPMENT AREA
VAA
1/4" UPD
1/2"x1/4" HDY
1" HDA
1500 GAL.
PRW TANK
4" CAA
3" EHN
4"x2" EDL
3" TAA
1" USS
1" HDA
1" HDE
EL. 18.0
PRESSURE
LEVEL
CONTROLLER
LEVEL GAGE
PRW
PUMPS
1"x1/4" HDY
VAA
1/4" UPD
1/4" CHA
1/4" HDA
3" CAA
6"x3" EDS
6"x6"x3" ECP
2" HDA
6"x3" EDS
TYP.
3 PLACES 2" CHA
6" CAA
2" HDI
2" HFA
2" TCD
2" TXH
2"x2"1" HDI
RW
TYP.
3 PLACES
2" CHA
IRRIGATION
PUMP
2"x1 1/2" HDY
3" EAA
TYP 3
PLACES
F
EL. 37.0
6"
1'-0"
2'-0" 1'-6"
J-J(PL. PM-69)
EL. 18.0
C EL. 19.5L
C EL. 20.5L
C 1 1/2" FRWL
C 2" PRWL
BOL EL. 27.0
BOL EL. 28.0
RAW WATER FILTER
PIPING. DETAIL A
(PI. PM-79)
G
EL. 37.0
2" CHA
EL. 18.0
C EL. 20.67L
C EL. 33.0L
C EL. 33.75L
2" HDA
BOL EL. 29.0
BOL EL. 27.0
L-L (PL. PM-69)
C EL. 25.0L
C EL. 26.0L
2" RW (IR)
1 1/2" PRW
4" CHA PRW
1 1/2" HDA
1 1/2"x1"x1 1/2" HDI
1" CHA PRW
1500 GAL.
PRW TANK
HOSE CONNECTION
DETAIL D (PL. PM-79)
1" TCD
1 1/2" HDA
1 1/2" CHA
1" TCD
1 1/4" CHACA (100)
1 1/4" HDA
1 1/4"x1 1/4"x1" HDI
1 1/4" CHA
1" HDI
1" HDA
1" TCD
1" BKP
1" USH
1" TCD
1" HDA
1" HDA
C-C (PL. PM-69 & 70)
TYP.
2 PLACES
C EL. 26.83L C EL. 26.5L
EL. 37.0
EL. 18.0
BOL EL. 29.0
C EL. 22.0L
C EL. 22.0L
C EL.L
26.83C EL. 26.5L
BRAKE AIR RECEIVER
1 1/4" CHA
3/4" CHA PRW
PRV STATION
DETAIL B
(PL. PM-79)
SERVICE AIR
COMPRESSOR
#2
3"x3"x1 1/4" HDI
3" BIQ
3" HDA
3" HDA
3/4" HDA
SERVICE AIR COMPRESSOR
PIPING TYP. FOR 2
SERVICE AIR RECEIVER
1 1/2" CA (30)
1" BCA (100)
3" CA (100)
3" PRW
MECHANICAL EQUIPMENT AREA
1" CA (30)
1" CA (100)
1 1/2" PRW
3" CHA
3" HDI
3" CHA
3" HFA
3" TCD
3" HDI
3" HDA
CA (100)
3/4" DRAIN
AIR DRYER
3" TCD
3" HDA
3/4"
DRAIN.
3" HDI
3" TCD
3" HDA
3" CHA
3" HFA
3" TCD
3" HDA
1 1/4" UST
CA (100)
TYP
FOR 2
3/4" CHA PRW
SERVICE AIR
COMPRESSOR #1
9 10
MECHANICAL EQUIPMENT AREA
EL. 37.0
EL. 18.0
C EL. 19.0L
C EL. 21.0L
BOL EL. 28.0
BOL EL. 29.0
BOL EL. 27.0
2" CHA
FRW
2" CHA
PRW
6" CAA
PRW
6" EAA
AUTOMATIC
STRAINER
#2
2" CHA PRW
C AUTOMATIC
STRAINER #3
PS CONNECTION
(TYP) DETAIL A
(PL. PM-
70).
6" ECP 6" ECP
1" HDB
CA (300)
1" HDJ
1 1/2"x1 1/2"x3/4" HDI
3/4" HDA
CA (30)
C EL.L
20.0
RAW WATER FILTERS
PIPING. DETAIL A
(PL. PM-79)
6" EAA
AUTOMATIC
STRAINER BACKWASH
PIPING, TYP. FOR 2
DETAIL C(PI. PM-79)
10"x6" EDS
10"x6" EDS
10"ECP
K-K (PL. PM-69)
5" CAA
5" EHN
6"x5" EIN
(TYP. 4
PLACES)
6" EHN
6" TWA
6" EHN
6" CAA UCW
6" UKD
6" EHN
VAA
1/4" UPD
1/4" HDA
1/4" CHA
1/4" EEQ
6" EAA
6"x3" EDL
3" CAA
3" EHN
STANDBY UCW
PUMP.
TYP. 6
PLACES.
TYP. 5
PLACES.
TYP. 5
PLACES.
F
BOL EL. 29.0
BOL EL. 27.0
BOL EL. 28.0
1" CHA
RW
1" HDA
1" EEQ
1 1/2"x1 1/2"x1" HDI
1" HDI
UNIT 2
UNIT 3
UNIT 1
2"x2"x1" HDI UNITS 1 & 2
1 1/2"x1 1/2"x1" HDI UNIT 3
1 1/2"x1 1/2"x3/4" HDI UNITS 1 & 2
1"x1"x3/4" HDI UNIT 3
N-N (PL. PM-69 & 70)
3/4" CHA CA (30)
1" CHA CA (100)
1" HDA
3/4" HDA
T
BOL EL. 29.0
3 D-D (PL. PM-69)
1" HDB
1x1x1/4 HDJ
1" HDB
1" TCL
1" HFD
GOVERNOR AIR RECEIVER
11.0 CU.FT.
1" CA (300)
1" TCL 1" HFD
EL. 18.0
3/4" CA (30)
1" HDF 1" CHA CA (300)
1" UST
VAA 0-600 PSI
1/4" UPD
1/4" HDB
1" UST
MERCOID PRESSURE SWITCH
START COMP. @ 320 PSI
STOP COMP. @ 350 PSI
GOVERNOR AIR
COMPRESSOR
NEW RELIEF VALVE
SET @ 385 PSI
F
H-H (PL. PM-69)
3" HDA
1 1/2" HDA
1" HDA
1" HDI
BOL EL. 29.0
BOL EL. 28.0
3" CHA
1 1/2" CHA
1" CHA
CA (100)
CA (30)
BCA (100)
3" HDI
1 1/2"x1"x1 1/2" HDI
1" CLEARANCE
DETAIL B (PL.PM-69)
NO SCALE
CONCRETE WALL
CONCRETE INSERTS
GALVANIZED STAND-OFF TUBES (4 REQUIRED)
PRESSURE
SWITCHES
1/4" BOLTS
DETAIL A (PL. PM-69)
NOT TO SCALE
BOL
EL.
8.
C
EL.
3.
L
PRES
SURE
SW
IT
CH-
M
OUNTE
D
ON
CONC.
W
ALL
(T
YP.
F
OR
3)
1/ 2" H
FA
1/ 2" T
CA
1/ 2" C
HA
1/ 2" H
DA 3"
C
HA
1/ 2" E
EQ
NOTES
FOR GENERAL NOTES AND LEGEND, SEE PL. PM-1.
FOR PIPING MATERIAL IDENTIFICATION, SEE PLS. PM-11 & 12.
REFERENCE DRAWINGS
SECTIONS & DETAILS.-SHEET 2, PL. PM-79.
HANGERS AND SUPPORTS, PLS. PM-88 & 89.
1.
2.
1.
2.
POWERHOUSE-MECHANICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
GENERATOR BAYS-EXPOSED PIPING
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PM
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE: 1/4" = 1'-0"
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
CWS
WHM
BDL
SVERDRUP & PARCEL AND ASSOCIATES, INC.
SECTIONS & DETAILS-SHEET 1
PM-78
ZONESYMBOL
2A
1A
5A CHANGED GOV. AIR SUPPLY PIPING (R-224)
DELETE TITLE WALL (R-162)
REVISED PIPE DIMENSIONS (R-140) 8/6/81
22 DEC 81
2 AUG 83
J.G.T.
MGT
12" 0 5' 10'
SCALE: 1/4" = 1'-0"
L
6" (TYP.)
3'-3" 3'-3"
4'-0" 3'-0"
6'-0" 4'-0"
12'-0"
R5' -0"
(TYP)
ID
1" NOZZLE
1" NOZZLE
11"x15" MANHOLE
GROUNDING PAD
(FAR SIDE)
1/2" NOZZLE
1'-0" 1'-0"
11" 1'-3" 11"1'-3"
4'-4"
3" FLANGED NOZZLE
1" NOZZLE
MANHOLE
(FAR END)
3/4" NOZZLE
3/4" NOZZLE
TYP.
R6
3/8" PL (TYP.)
TYP.
3/16
GROUNDING PAD
C (4)-7/8" DIAM HOLESL
SIDE VIEW END VIEW
PUMPED RAW WATER PNEUMATIC TANK
1'-6"2'-0"
30°
15°20°
30°
45° 45
45° 45
45° 45
3'-0" O.D.
/2
2'-6" O.D.
M
IN
1"
2"
18" O.D.
/2
4'-0" O.D.
"2
1/ 2"
5'-6" O.D.
1 1/4"
POWERHOUSE-MECHANICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
GENERAL
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PM
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
HGW
HGW
JAT
SVERDRUP & PARCEL AND ASSOCIATES, INC.
TANKS-SHEET 1
PM-86
1/2" = 1'-0"
NOTES
FOR GENERAL NOTES AND LEGEND1.
SEE PL. PM-1
ALL FLANGED NOZZLES SHALL HAVE
150# FLAT FACE
SLIP-ON FLANGES WITH BOLT HOLES
STRADDLING THE CENTER LINES
UNLESS NOTED OTHERWISE.
2.
3" FLANGED NOZZLE
1 1/4" NOZZLE
GROUNDING PAD
3" FLANGED NOZZLE
1/2" NOZZLE W/PLUG
11"x15" MANHOLE
1/2" NOZZLE
PLAN PLAN
1/2" NOZZLE W/PLUG
1/2" NOZZLE
1" NOZZLE
C 2" INSPECTION
OPENING
L
1 1/4" NOZZLE
GROUNDING PAD
1" NOZZLE
C 2" INSPECTION
OPENINGS
L
1" NOZZLE
1/2" NOZZLE W/PLUG
1" NOZZLE
1" NOZZLE
GROUNDING PAD
PLAN
3/4" NOZZLE
16"x12" MANHOLE
2" NOZZLE
1" NOZZLE
2 1/2" NOZZLE
1" NOZZLE
1/2" NOZZLE
4" FLANGED NOZZLE
3/4" NOZZLE
1" NOZZLE
PLAN
3/4" NOZZLE
4" FLANGED NOZZLE
3" NOZZLE
2" NOZZLE
3" NOZZLE
2" NOZZLE
PLAN
1/2" NOZZLE W/PLUG
1/4" NOZZLE
3" FLANGED NOZZLE
(FAR SIDE)
1/2" NOZZLE
3" FLANGED NOZZLE
GROUNDING PAD
1" NOZZLE
3/8" PL, 3'-0" O.D.x2'-0" I.D.
(4)-7"x7" HANDHOLES
EQUALLY SPACED IN
1/4" PL STAND
(4)-7/8" DIAM HOLES
"R
ELEVATION
SERVICE AIR RECEIVER
2 REQUIRED
ELEVATION
BRAKE AIR RECEIVER
ELEVATION
GOVERNOR AIR RECEIVER
(4)-4"x6" HANDHOLES
EQUALLY SPACED IN
1/4" PL STAND
(4)-7/8" DIAM HOLES
1" NOZZLE
2" INSPECTION
OPENING
1/2" NOZZLE
1/2" NOZZLE W/PLUG
1" NOZZLE
1 1/4" NOZZLE
GROUNDING PAD
1" NOZZLE
R
1/ 2"
1/4" PL, 2'-0" O.D.x1'-4" I.D.
1/2" NOZZLE W/PLUG
1" NOZZLE (FAR SIDE)
IN
S P
E C
T
IO
N
O P
E N
IN
G S
1" NOZZLE
1/4" NOZZLE
(FAR SIDE)
GROUNDING PAD
1" NOZZLE
(4)-4"x10" HANDHOLES
EQUALLY SPACED IN
1/4" PL STAND
R 1/ 2"
1/ 2"
1/4" PL, 1'-6" O.D.x0'-10" I.D.
(4)-7/8" DIAM HOLES
1" NOZZLES
3/4" NOZZLE
3/4" NOZZLES
3/4" NOZZLES
2 1/2" NOZZLE
(4)-12"x12" HANDHOLES
EQUALLY SPACED IN
1/4" PL STAND
1" NOZZLE
GROUNDING PAD
2" NOZZLE
2'- 0'R
(4)-7/8" DIAM HOLES
3/4" PL 4'-3" O.D.x
3'-3" I.D.
ELEVATION
TREATED WATER
HYDRO-PNEUMATIC TANK
ELEVATION
TREATED WATER
GRAVITY STORAGE TANK
(4)-7/8" DIAM HOLES
GROUNDING PAD
3"x3"x1/4" " R.
2'-10
3" NOZZLE
2" NOZZLE
3/4" NOZZLES
(FAR SIDE)
2" NOZZLE
GROUNDING PAD
20" DIAM. MANHOLE
(FOR DETAIL,
SEE PL. PM-87)
DRILL AND TAP THRU
TANK SUPPORT AFTER
WELDING TO TANK 3/8"-16-NC-2
2 1/2"x2"x1/4" PL
WELD TO
TANK SUPPORT
TYPICAL GROUNDING PAD
(NOT TO SCALE)
SCREWED
BOTTOM & TOP OUTLET
SCREWED
SIDE OUTLET
FLANGED
TYPICAL TANK NOZZLES (PL. PM-87)
(NOT TO SCALE)
TANK SHELL
OR HEAD
1/4
150# S.O. FLANGE
3/16
1/4
1/4
X.H. STEEL COUPLING
OUTSIDE OF TANK
3/16
1/4
GRIND SMOOTH
X.H. STEEL HALF
COUPLING
12" 0
SCALE: 1/2" = 1'-0"
1' 2' 3' 4'
POWERHOUSE-MECHANICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
HEATING VENTILATING & AIR CONDITIONING
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PM
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE: NONE
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
ADDED FD (GR-9) 4/18/80 M.G.T.
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
JRL
FCD/WHM
HS
SVERDRUP & PARCEL AND ASSOCIATES, INC.
AIR FLOW DIAGRAMS-SHEET 1
PM-102
5B
2 DELETE & ADD FD (R-155) 11 JAN 82 E.P.W.1B, 1C
3 REVISE SYSTEM 3 (M-134) (R-179) 25 JUN 82 E.P.W.5B
NOTES
FOR GENERAL NOTES AND PIPING LEGEND,
SEE PL. PM-1.
FOR HVAC LEGEND SEE PL. PM-103.
1.
2.
REFERENCE DRAWINGS
AIR FLOW DIAGRAMS PL. PM-103
CONTROL DIAGRAMS PL. PM-104
PIPING DIAGRAMS PL. PM-105
EQUIPMENT SCHEDULE PL. PM-106
1.
2.
3.
4.
SHOWER &
DRY RM
V
400 475 2720
LOCKERS
V
TOILET
37-10
V
JANITOR'S
CLOSET
V
CORRIDOR
NO. 2
V
FLAMMABLE
STORAGE
V
CORRIDOR
NO. 1
V
ELEVATOR
MACH. RM.
V
STAIR
NO. 1
V
GATE
REPAIR
V
100280 20 200 100 325 650
75 CFM
FROM FIRST AID
TOILET (SYSTEM 1)
120 180 350
700 700
SEWAGE
TREATMENT
V
10001050
50 CFM FROM
CORRIDOR ROOM 2-1
(SYSTEM 2)
100 CFM
FROM CORRIDOR
RM 2-1
(SYSTEM 2)
125 CFM FROM
TOILET RM 18-7
(SYSTEM 2)
WATER
TREATMENT
V
950950
DH-3F
FD
FD
FD D-3W D-3V
DH-3D
F-6
SF-6
AH-6
CFM
VELECTR. SHOP
D-3AA
D-3Z
11,275
V
OA
1000 1000HVAC RM NO. 2
D-3C
RF-3
SA
HC-317,495
D-3Y
FD
SF-3 D-3A1
D-3A2AH-3 F-3
(MIN)
D-3B
OIL PUR-
IFICATION
V
925925
OIL
STORAGE
V
475475
SERVICE
AREA
V
950950
FD
FD
FD
3600 3600MAINT. SHOP & LOCKED STOR.
SYSTEM 3
CFM
SF-5
V
AH-5
WELDING EXHAUST UNIT
D-3U F-5
D-3T
DH-3E
FD
FD
ELEVATOR
LANDING
V
STAIR
NO 1
V
INSPECTION
GALLERY
V
ELEVATOR
LANDING
V
STAIR
NO 1
V
ELEVATOR
LANDING
V
STAIR
NO 1
V
700 700
700 CFM
TO SYSTEM 2
FD
SYSTEM 1
FD
FD
ELEVATOR
LANDING
V
STAIR
NO 1
V
ELEVATOR
LANDING
V
STAIR
NO 1
V
VESTIBULE
V
STAIR
NO 1
V
300 525
150 375
400 325
STAIR
NO 1
V
350350
V
STORAGE
AND
RECORDS
FD
VD
VD
FD
D-3J
D-3E D-3D
FD
GATE
REPAIR
V
600350350
V
STORAGE
VD
VD
D-3G D-3F
D-3K
FD
FD150
FD
600600
EF-3D V
GATE
REPAIR
V
EMERG GEN RM
FD FD
FD D-3S
OA
D-3P
EF-3C
DH-3A
DH-3C
D-3HD-3I
DH-3B
FD
VD
VD
FD EA
8000/4000
D-3R
D-3G
550550
FAN ROOM
D-3ND-3M
V
EF-3BEF-3A
FD
EA
EA
(MAX.)
EA
11,275
FDFD
EA
FD
OA
FD
FD
5 1
FD
FD
FD
OA
FD
WOMEN
V
200250
LOBBY
14251225
MEN
V
175225
STORAGE
V
CLOSET
SUPT.
OFFICE
TOILET
V
57-11
JANITOR'S
V
CLOSET
ELECTRONIC
MAINT
BATTERY
CHARGER
COMM
RM
TOILET
V
57-15
1000 750 475 750
FIRST AID
FIRST AID
V
TOILET
3625 3800
IN HVAC RM NO 1
EA
OA
D-LAL, 2
94.5
(MIN.)FI
CC-1
SF-1
AH-1
D-1C
D-1B
RF-1
REF-1
50 50 20 100 7520 FROM
SYSTEM 2
CONTROL RM.
KITCHEN EA
TO SYSTEM 3
EXFILTRATION
TO OUTSIDE
250 475 495 595 615
715 75
RA
SA
HC-1
EL. 2.0
EL. (-)2.67
EL. 18.0
EL. 17.0
EL. 37.0
EL. 57.0
EL. 72.0
EL. 87.0
EL. 86.0
EL. 96.0
EL. 57
EL. 37
EL. (-) 24.0
ERECTION BAY
66'-0"
GEN. BAY 1
70'-0"
GEN. BAY 2
70'-0"
GEN. BAY 3
70'-0"
276'-0" POWERHOUSE
FISH LIFT
45'-2"
C C
A N
A L G
E N B
A Y
L
INTAKE
RETAINING
WALL
F L
O W
INTAKE
RETAINING
WALL
FISH
CHANNEL
EL. 65.0
SERVICE ROAD
OBSERVATION
ROOM ROOF
CONTROL ROOM
ROOF
RAMP
DOWN
RAMPU
P
SERVICE ROAD
EL. 51.0
EL. 46.0
DRAFT TUBE
GANTRY CRANE
MICROWAVE DISH
ANTENNA
REST AREA
LOW ROOF
HIGH ROOF
C UNITSL
DRAFT TUBE DECK-EL. 57.0
TO FISH LIFT FACILITIES
VISITORS ENTRANCE
EMPLOYEE'S ENTRANCE
RETAINING WALLCONC. WALK
EMPLOYEE'S PARKING
SERVICE ROAD
FLAGPOLE
1 5 6
TAILRACE
RETAINING
WALL
TAILRACE
RETAINING
WALL
U N
IT
M
O N
O L
IT
H
S E
R V
IC
E A
R E
A
H
G
F
B
A
9'-0" 62'-0"
2'-0" 2'-0"
66'-0"
2'-0" 2'-0"
66'-0" 2'-0" 2'-0"
66'-0" 2'-0"
37'-0"
9 10 13 14 17
12"0 10' 20' 30'
SCALE: 1/16" = 1'-0"
SWITCH YARD
T O V
IS
IT
O R S P
A R
K
IN
G
INTAKE DECK-EL. 86.0
INTAKE
GANTRY
CRANE
N REF. N
POWER PLANT-GENERAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ARRANGEMENT
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PG
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
GENERAL PLAN
PG-1
1/16" = 1'-0"
DESIGN CHECK
G.L.D.L.D.W.
PREPARED BY:
PRINCIPAL OF FIRM
REVIEWED:
CHIEF,
ARCHITECTURAL SECTION
RECOMMENDED:
CHIEF,
DESIGN BRANCH
DATE: 15 JANUARY 1979
A
B
C
D
E
F
G
1 5 6 9 10 13 14 17
327'-0"
ERECTION BAY
78'-6"
GEN BAY 1
70'-0"
GEN BAY 2
70'-0"
GEN BAY 3
70'-0"
FISH LIFT
38'-6"
12'-6" 66'-0"
(TYP)
40'-0"
(TYP)
30'-0" 1'-6"37'-0"
2'-0"
2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0"
A
B
1 3
INSPECTION GALLERY PUMPS
EL. (-) 30.50
STAIR
NO. 1
UP
ELEV
NO. 1
D N
ELEVATOR
LANDING
EL. (-) 24.0
SEPTIC
TANK
SLUDGE
PUMP
STAIR NO. 1
DN
UP
ELEV
NO. 2
32'-0"
PLAN - EL. (-) 2.67
UNWATERING
SUMP
EL. (-) 37.0
SEWAGE
TREATMENT RM.
EL. 2.0
CHLORINATOR
EFFLUENT
PUMPS
SINK
HOISTWAY
EMERGENCY ACCESS
EL. (-) 2.67
CORRIDOR
EL. 2.0
STA. DRAINAGE
SUMP
EL. (-) 31.0
ELEV
NO. 1
U P
WALL MOUNTED
FIRE EXTINGUISHER
STAIR NO. 2
TW GAGE WELL
PLAN - EL. (-) 24.0 AND EL. 2.0
TAILRACE RETAINING WALL
EL. 0
C UNIT 1L
S
LO
P E D
N
EL. 4.0
SPIRAL CASE ACCESS
DRAFT TUBE ACCESS
DN
INSPECTION GALLERY
EL. 0
C UNIT 2L
S
LO
P E D
N
EL. 0
C UNIT 3L
S
LO
P E D
N
5'-0"
STAIR NO. 16
U P
DN
STAIR NO. 17
U
P DN
U P
POWERHOUSE
PIEZOMETER CONSOLE
STORAGE AREA
EL. 2.0
WALL MOUNTED
FIRE EXTINGUISHER
DRAFT TUBE
GATE SLOT
A LINE, C CANAL & C GEN BAY 2
SEE PL. PP-1
L L
S L
O P
E D
N
S T
A
IR
N
O
STAIR NO. 3
U P
D N
STAIR
NO. 18
STOPLOG
EL. (-) 4.0
TAILRACE RETAINING WALL
FISH
CROWDER
CHANNEL
EL. (-) 6.0
LIFT
CHAMBER
EL. (-) 7.0
EL. (-) 27.47
A
G
C UNITSL
POWER PLANT - GENERAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ARRANGEMENT
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PG
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE: 3/32" = 1'-0"
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
JMN
A.F.T.
L.D.W.
SVERDRUP & PARCEL AND ASSOCIATES, INC.
PLAN - EL. 2.0
PG-2
12"0 5' 10' 15' 20'
SCALE: 3/32" = 1'-0"
N REF. N
327'-0"
ERECTION BAY
78'-6"
GEN BAY 1
70'-0"
GEN BAY 2
70'-0"
GEN BAY 3
70'-0"
FISH LIFT
38'-6"
12'-6" 66'-0"
(TYP)
40'-0"
(TYP)
30'-0" 1'-6"37'-0"
2'-0"
2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0"
ITEM
CLEAN TRANSFORMER OIL TANK
DIRTY TRANSFORMER OIL TANK
CLEAN BREAKER OIL TANK
DIRTY BREAKER OIL TANK
DIRTY LUBRICATING OIL TANK
CLEAN LUBRICATING OIL TANK
OIL PURIFIER
DRAIN OIL COLLECTION TANK
TOTALIZING METERS
BREAKER OIL TRANSFER PUMP
TRANSFORMER OIL TRANSFER PUMP
LUBRICATING OIL TRANSFER PUMP
WASTE OIL SUMP PUMP
REACTIVATOR
UNWATERING PUMP #1
UNWATERING PUMP #2
UNWATERING SUMP DRAINAGE PUMP
EQUIPMENT HATCH
ITEM
UNWATERING SUMP ACCESS HATCH
STATION DRAINAGE SUMP ACCESS HATCH
STATION DRAINAGE PUMPS
CO RELAY CABINET
MCC-6 PUMP BOARD
CONTROL METER
HYPOCHLORITE SOLUTION TANK
GRAVITY STORAGE TANK
HYDRO-PNEUMATIC TANK
TREATED WATER PUMPS
PRW TANK
PRW PUMPS
IRRIGATION PUMP
STRAINER NO. 1
UCW PUMP NO. 1
RW FILTER
STRAINER NO. 2
DESCRIPTION
CO CYLINDERS
DESCRIPTION ITEM
STRAINER NO. 3
STAND-BY UCW PUMP
MCC-7
STRAINER NO. 4
GOVERNOR AIR COMPRESSOR
GOVERNOR AIR RECEIVER
SERVICE AIR COMPRESSOR NO. 1
AIR DRYER
AIR RECEIVERS
BRAKE AIR RECEIVER
SERVICE AIR COMPRESSOR NO. 2
RW HVAC PUMP
STRAINER NO. 5
UCW PUMP NO. 3
WALL MOUNTED FIRE EXTINGUISHER
UCW PUMP NO.2
DESCRIPTION
POWER PLANT - GENERAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ARRANGEMENT
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PG
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE: 3/32" = 1'-0"
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
J.M.N
A.M.C
L.D.W
SVERDRUP & PARCEL AND ASSOCIATES, INC.
PLAN EL. 18.0
PG-3
12"0 5' 10' 15' 20'
SCALE: 3/32" = 1'-0"
EQUIPMENT SCHEDULE
N REF. N
1 3 5 6 9 10 13 14 17
A
B
C
D
E
F
G
C UNITSL
LIFT
CHAMBER
FISH
CROWDER
CHANNEL
GRATING
EL. 4.0
FISH
ENTRANCE
CHANNEL
EL. 4.0
STAIR NO. 1
UP
DN
ELEVATOR
NO. 1
ELEVATOR LANDING
EL. 18.0
1 2 2
1 3
R A
M P D
N
CHILLING SUMP
(TYP)
OIL STORAGE
EL. 17.0
OIL SUMP
10 11
D N
DN
O
IL
P
U R
IF
IC
A T
IO
N
E L .0
C UNIT 1L C UNIT 2L C UNIT 3L
TRASH RACK
SLOT
INTAKE GATE
SLOT
15 18
SERVICE AREA
EL. 18.0
27 28
WATER
TREATMENT
ROOM
TOILET
INTAKE RETAINING WALL
D N
U P
ELEVATOR NO. 2
STAIR NO. 2
TW GAGE WELL
EWC
LTG. PANEL LP4C
CORRIDOR
31 32
TAILRACE RETAINING WALL
35 36 37
LTG PANEL
LP2C
42 44 45 46
MECHANICAL EQUIPMENT AREA-EL. 18.0
PLAN EL. 18.0
DRAFT TUBE
GATE SLOT
DN
UP
MATERIAL HATCH
STAIR NO. 3
STOPLOG (TYP)
EL. 4.0
INTAKE RETAINING WALL
12'-6"
A
C
D
E
F
G
66'-0"
GENERATOR BAY 1
70'-0"
GENERATOR BAY 2
70'-0"
GENERATOR BAY 3
70'-0"
FISH LIFT
38'-6"
1'-6"
78'-6" (ERECTION BAY)
327'-0"
1 3 5 6
T U
N N
E L
C A
B L E
9 10 13 14 17
POWER PLANT-GENERAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ARRANGEMENT
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PG
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
JMN
AMC
L.D.W.
SVERDRUP & PARCEL AND ASSOCIATES, INC.
PLAN EL. 37.0
PG-4
3/32" = 1'-0"
REF. NN
PLAN EL. 37.0
INTAKE RETAINING WALL
STORAGE AND RECORDS
STAIR NO. 1
DN
UP
ELEV.
NO. 1
DUCT SHAFT
GATE PEDESTAL
GATE REPAIR
FE
M C
C
ELEVATOR
MACH RM
NO. 1
FE
AIR
HANDLING
UNIT
NO. 3
HVAC RM. NO. 2
LP4
ELECTRIC
SHOP
FLAMMABLE
STORAGE
SHOWER & DRY RM
L O
C K
E R
S
TOILET FIRST
AID
EWC
CORRIDOR NO. 2
STAIR NO. 2
MAINTENANCE SHOP
ELEV.
NO. 2
FIRST AID TOILET
CABLE GALLERY
GROUND
TEST STA
FE
TW GAGE WELL
JAN
CLOSET
U P
D N
CART MOUNTED
FE
FE
FE
13 12
3 2
FE
WELDING
CURTAIN
PUMP ACCESS
HATCH
FE
EL. 36.50
TAILRACE RETAINING WALL
LOCKED
STORAGE
LP4B2
MAINTENANCE SHOP EQUIPMENT SCHEDULE
DESCRIPTIONITEM
1. PEDESTAL GRINDER
2. WORK BENCH
3. DRILL PRESS
4. VISE
5. ARBOR PRESS
6. BENCH LATHE
7. PORTABLE PIPE THREADER
8. POWER HACKSAW
9. WORK SUPPORTS
10. BAR RACK
11. MOBILE HOIST
12. PORTABLE WELDER
13. GROUNDED WELDING FRAME
14. OXY-ACET. WELDING OUTFIT
15. ANVIL
16. CO CYLINDER
17. FLAMMABLE STORAGE RM FIRE PROTECTION SYSTEM
CONTROL CAB
18. SHELVES
19. MAINTENANCE SHOP POWER PANEL 13P
12"0 5' 10' 15' 20'
SCALE: 3/32" = 1'-0"
INTAKE RETAINING WALL
LP1A
FE
MCC 1
POTENTIAL
SOURCE TRANSF
GEN 1 STATIC
EXCITATION
EQPT
GEN 1 13.8KV
SWITCH GEAR
STA. SERVICE
TRANSF 1
480 VOLT - STA.
SERVICE SWITCHGEAR
GEN 2 13.8 KV
SWITCH GEAR
GEN 2 STATIC
EXCITATION
EQPT
STA. SERVICE
TRANSF 2
POTENTIAL
SOURCE TRANSF
FE FE FE
SWITCHGEAR ROOM
FE FE
LP2B
FE FE
EWC
POTENTIAL
SOURCE TRANSF
STAIR NO. 3
GEN 3 STATIC
EXCITATION
EQPT
GEN 3 STATIC
EXCITATION EQPT
10 TON HOIST AND
MONORAIL ABOVE
MATERIAL
HATCH
DN
UP
PIPE TRENCH
FISH
CROWDER
EL. 30.0
EL. 30.0
EL. 4.0
STOPLOG (TYP)
TAILRACE
RETAINING WALL
EL. 34.0
LIFT
CHAMBER
CL UNITS
POWERHOUSE
CRANE ACCESS
LADDER
CL UNIT 3CL UNIT 2CL UNIT 1
MCC 2
MCC 3
D N
D N
U P
FILTER
STAIR NO. 6
D N
D N
U P
FILTER
STAIR NO. 5
D N
D N
U P
FILTER
STAIR NO. 4
PIPE TRENCH PIPE TRENCH
GOVERNOR
LTG DISTR
PANEL 15P
GENERATOR
NEUTRAL
CUBICLE
GOV
PRESS
TANK
THRUST
BEARING
ACCESS
PIPE TRENCH
FE
FLOWMETER
INTAKE
GATE
SLOT
CO CONTROL CAB2
CO CYLINDER2
TURBINE PIT EXHAUST
FAN (TYP)
GEN. JACKING
PUMP
AUTO
GREASING UNIT
B1
6'-0" 27'-6"
22'-0"
3'-0" F
G
B
A
1 5
ELEVATOR
MACHINE
ROOM NO. 2
ELEV
NO. 2
HOISTWAY
STAIR
NO. 2
D N
D N
FUEL TANKS
DIESEL GEN CONTROL BD
S E
R V
IC
E A
R E
A
12'-6"
BAY
ERECTION
66'-0"
GEN BAY 1
70'-0"
GEN BAY 2
70'-0"
GEN BAY 3
70'-0"
FISH LIFT
45'-2"
333'-8"
26'-6"
20'-8"1
11'-8"
25'-0"
EQUIPMENT SCHEDULE
DESCRIPTIONITEM
PAX
CCB
CARRIER
DATA
SUPERVISORY
LOAD CONTROL
EVENTS
MICROWAVE
BATTERY CHARGER PANEL-11 P
BATTERY CHARGER
INVERTER
DC DISTRIBUTION PANEL
120 V TEST PANEL 12 P
MICROWAVE BATTERY CHARGER
PLAN - EL. 67.5
PLAN-EL. 86.08
PLAN - EL. 57.0
C O
N T
R O
L P
A N
E L
C O
N T
R O
L R
M
E L .0
STAIR NO. 22
F
IL
E R
M
LAV
WC
S.S
C UNITSL
CONC
CANOPY
FAN FE
ROOM
EL. 96.0
ELEV
HOISTWAY
D N
U P
DN
DUCT
SHAFT
HIGH ROOF
PLAN-EL. 96.0
IN
T
A K
E G
A N
T R
Y
C R
A N
E R
A
IL
S
C L
C POWERHOUSE CRANE
RAIL
L
HANDRAIL
MCC 8
EXHAUST LOUVER
HEADWATER
RECORDER-TRANSMITTER
V E
S T
IB
U L E
E L .0
RAMP
DN
GATE
REPAIR HATCH
INTAKE DECK-EL. 86.0
INTAKE
LOUVER
D U
C T S
H A
F T
P L
A N
T E
R
ELEV.
NO 1
DN
UP
PLAN - EL. 87.0
GATE REPAIR
PLATFORME
L E
V A
T O
R
L A
N D
IN
G
ELEV
NO. 1
DN
UP
EXHAUST FAN
3C
DIESEL
GENERATOR ROOM
H.W
GAGE
WELL
FE
DIESEL GEN
STAIR
NO. 1
DUCT
SHAFT
PLAN - EL. 72.0
INTAKE
RETAINING WALL
SLOPE
OBSERVATION
ROOM
EL. 65.0
EWC
C
L U
N
IT
S
PLANTER
BOX
CONC WALK
CONC
WALK
EL. 57.0
EL. 52.0
TAILRACE RETAINING
WALL
FISH ENTRANCE
CHANNEL
EL. (-) 4.0
STOPLOG
EL. 30.0
EL. 30.0
S L
O P
E
40 HP
MOTOR
GEAR
SPEED
REDUCER
U P
EL. 57.0
FISH
CROWDER
CHANNEL
U P
P L
A N
T E
R B
O X
S L
O P
E
H O
L D
IN
G
P O
O L
E L .0
PLAT FORM
C UNIT 3 L EL. 52.0
CRANE ACCESS
LADDER
PLATFORM
EL. 67.0
ACCESS
HATCH
STORAGE
DIESEL GEN
WATER PUMP
STAIR
NO. 1
DUCT
SHAFT
ELEV
NO. 1
UP
DN
E L E
V
L A
N D
IN
G
STAIR
NO. 20
GATE REPAIR
PLATFORM
U P
OIL BOX
SLUDGE BOX
RETAINING
WALL
FE
FE ON
WHEELED CART
CRANE CAB ACCESS
PLAT FORM - EL. 72.0
OIL SERVICE SUMP
ROTOR
ERECTION
SOLE PLATE
PUMP
ACCESS
HATCH
R A
IL
IN
G
Z -S
E C
T
IO
N
V E
R T
IC
A L L
IF
T D
O O
R
INTRUSION ALARM
CONTROL PANEL
FIRE DETECTOR
CONTROL PANEL
PUMP
ACCESS
HATCH
ERECTION FLOOR
EL. 57.0
EMPLOYEES
TELEPHONE
C A
N O
P Y O
V E
R
POWDER BAR
PUBLIC
LOBBY
EL. 57.0
WOMEN
LAV WC WC
URINAL
MEN
LAV
INFORMATION
WINDOW
SUPT. OFFICE
TOILET
LAV
WC
ELEV
NO. 2
D U
C T
S H
A F
T
FE
EWC
FE
STORAGE CLO
LP 4A
EWC
STAIR
NO. 2 U
P
D N
STAIR
NO. 4
EL. 37.0
CL UNIT 1
ACCESS
HATCH
TOP OF GEN HOUSING
EL. 54.58 (TYP)
DN
GEN
ACCESS
EL. 57.0
D N
JAN CLO
KITCHEN
UNIT
KEY
CASE
MAIN RELAY BOARD
TAILWATER
RECORDER
TRANSMITTER
FE. DATA
PRINTER
TOILET
LAV
WC
SHELF & POLE
VISITOR'S WALKWAY TO FISH OBSERVATION ROOM
CORRIDOR-EL. 57.0
FE
MAIN CONTROL BOARD
CONTROL ROOM
EVENTS
PRINTER
DRAFT TUBE GATE-GRATING COVER
R E
C O
R D
E R
O
A R
D
DC PANELS
A U
X
R E
L A
Y
B D
PREF AC
PANEL
FILE
ROOM
SUPPLY
ROOM
C O
M M
U N
IC
A T
IO
N S
R O
O M
1 2
4 5
EMERGENCY SHOWER
AND EYE WASH
STAIR
NO. 5
STAIR
NO. 6
DN DN
D N
D N
GEN
ACCESS
EL. 57.0
GEN
ACCESS
EL. 57.0
CL UNIT 2
ACCESS
HATCH
EL. 37.0
TOWEL CAB AND
WASTE RECEPTACLE
MICROWAVE
BATTERY
BATTERY
RM
STATION
BATTERY
SINK
B A
T T
E R
Y
C H
A R
G E
R
E L E
C T
R O
N
IC
S
M A
IN
T E
N A
N C
E
FE
AIR
HANDLING
UNIT #1
AIR
HANDLING
UNIT #4
LTG PANEL
LP 2A
MCC 4 CHILLED
WATER
PUMPS
FE
HV AND AC
ROOM NO. 1
CHILLER
RAW WATER PUMPS
AIR
HANDLING
UNIT #2
FISH CROWDER
CL CRANE RAIL
STAIR
NO 3
DN
HANDRAILDRAFT TUBE DECK-EL. 57.0
REST AREA
SECURITY FENCE
EL. 65.0
LIFT
CHAMBER
EL. (-) 7.0
M C
C
L E
V E
L C
O N
T R
O L
P A
N E
L
EL. 60.21
E Q
U
IP
E L .0
H Y
D R
A U
L
IC
P
U M
P S
P O
W
A
E A
P L
A N
T E
R B
O X
C O
R R
ID
O R -E
L .0
A
B
D
(PL. PG-7)
A
F
G
H
A
B
A
B
1 2 4 5 6 9 10 13 14 17
A
B
C
D
E
F
G
H
A
POWER PLANT - GENERAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ARRANGEMENT
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PG
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE: 3/32" = 1'-0"
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
J.M.N
A.F.T.
L.D.W.
SVERDRUP & PARCEL AND ASSOCIATES, INC.
PLANS - EL. 57.0, 67.5, 72.0 & 86.0
PG-5
1235 4
N REF. N
12"0 5' 10' 15' 20'
SCALE: 3/32" = 1'-0"
INTAKE
GATE SLOT
FE
C INTAKE CRANE RAILS
A B C D E F G H
L
EL. 89.50
EL. 86.0
EL. 72.0
EL. 57.0
EL. 37.0
EL. 15.0
EL. (-) 26.0
EL. VARIES
EL. (-) 41.0
DIESEL
GEN RM
INTAKE DECK
STOR
STOR &
REC
INSPECTION
GALLERY
EL. 93.92
GATE REPAIR
PLATFORM
GATE REPAIR
PLATFORM
GATE REPAIR
EL. 17.0
LOCK STOR
OIL STORAGE
TRANSVERSE SECTION THRU ERECTION BAY
EL. (-) 31.0
STA DRAINAGE
SUMP
SERVICE AREA
MAINTENANCE SHOP
ERECTION FLOOR
EL. (-) 4.50
CORR
EL. 2.0
EL. 18.0
EL. 37.0
EL. 57.0
EL. 60.0
EL. 67.50
EL. 69.50
EL. 77.0
EL. 101.0
EL. 95.34
EL. 81.25
ELEV
MACH
RM NO. 2
CORR
CORR
CORR
ELEV
NO. 2
FIRST AID
TOILET
CABLE
GALLERY
SUPT'S
OFFICE
A B F
A B F G H
INTAKE GANTRY
CRANE
INTAKE
DECK
POWERHOUSE CRANE
EL. 101.0
C UNITS
L GEN
ACCESS
CONTROL ROOM
DRAFT
TUBE
DECK
DRAFT TUBE
GANTRY CRANE
EL. 76.50
EL. 57.0
EL. 37.0
EL. 18.0
EL. 2.0
EL. (-) 22.32
EL. 0.0
EL. (-) 41.0
TYPICAL TRANSVERSE SECTION THRU C UNITL
EL. VARIES
EL. 15.0
STORAGE
AREA
MECHANICAL
EQUIPMENT
AREA
SWITCHGEAR
ROOM
TURBINE
ROOM
EL. 86.0
EL. 65.0
EL. 83.50
HOLDING POOL
EL. 60.21
EL. 86.50
C UNITSL G H
TRANSVERSE SECTION THRU FISH LIFT
FISH CROWDER
CHANNEL
EL. 23.0
EL (-) 7.0
EL. 50.22
LIFT
CHAMBER
EL. 100.50
EL. 63.25
EL. 60.50
TOP OF CANOPY
EL. 70.0
EL. 49.50
EL. 47.0
EL. 57.0
EL. 52.0
EL. 30.0
EL. 4.0
EL. (-) 4.0
EL. (-) 6.0
012" 5' 10' 15' 20'
SCALE: 3/32" = 1'-0"
POWER PLANT-GENERAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ARRANGEMENT
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PG
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
J.M.N
A.F.T.
L.D.W.
SVERDRUP & PARCEL AND ASSOCIATES, INC.
TRANSVERSE SECTIONS
PG-6
3/32" = 1'-0"
TOILET
EL. 17.0
RETAINING
WALL
CORR
EL. 18.0
C DISTRIBUTORL
EL. 15.0
STA DRAINAGE
SUMP
EL. (-) 31.0
EL. (-) 37.0EL. (-) 39.0
UNWATERING
SUMP
SERVICE AREAOIL
PURIFICATION
ROOM
ELECTRIC
SHOP MAIN TENANCE
SHOP
C O
N T
R J
T
EL. (-) 41.0
EL. 37.0
EL. 57.0
EL. 72.0
EL. 81.25
EL. 101.0
EL. 110.0
CRANE CAB ACCESS
PLATFORM EL. 72.0
SERVICE BOX
ERECTION FLOOREL. 64.50
ACCESS PLATFORM
EL. 33.0
C O
N T
R J
T
C O
N T
R J
T
BUMPER STOP
OPERATOR'S
CAB
LONGITUDINAL SECTION THRU C OF UNITS
6'-0" 27'-6" 32'-6"
ERECTION BAY
66'-0"
210'-0" (3 SPACES @ 70'-0") GENERATOR BAYS
40'-0" 30'-0"
C UNIT 2LC UNIT 1L C UNIT 3L
9 10 1413 17
CRANE FEEDRAIL
TOP OF RAIL, EL. 81.94
GENERATOR
HOUSING
POWERHOUSE CRANE
(2 TROLLEYS)
26'-2"
EL. (-) 7.0
EL. 81.25
EL. 50.31
LIFT
CHAMBER
STAIR NO. 19
C O
N T
R J
T
SPIRAL
CASE
TURBINE
PIT
L
A - A (PL. PG-5)
(LOOKING UPSTREAM)
DRAFT TUBE
C HANDRAILL
CRANE CORBEL
CRANE FEEDER
PULL BOX
TURBINE
FLOOR
EL. 57.0
EL. 52.0
POWER PLANT - GENERAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
ARRANGEMENT
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PG
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE: 3/32" = 1'-0"
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE
REVISIONS
DATE BY
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
JMN
A.F.T.
L.D.W.
SVERDRUP & PARCEL AND ASSOCIATES, INC.
LONGITUDINAL SECTION
PG-7
19'-0"
CONTROL RM
SCALE: 3/32" = 1'-0"
12"0 5' 10' 15' 20'
EL. 67.0
EL. 65.0
POWER
EQUIP
AREA
EL. 86.08
EL. 65.0
EL. 57.0
EL. 100.50
CORR
DESCRIPTION
VISITORS ENTRANCE)
(SECTION THRU CONTROL ROOM AND
FISH LIFT
45'-2"
74H
P N
2A
P N
GEN. 1 AS STA. SERV.
GEN. 2 AS LINE 1
GEN. 3 AS LINE 2
SPARE AS SPARE
AX
AX1
48 A101
71Q4 A102A
71Q6
63Q3
63Q1 A102B
80TQF2
71TQS A103
71TQR
72TQP A104
74TL A105
71GQL A106
80WG A107
80WA A108
80TPW A109A
71THC3
72THC A109B
23TB
23TQ A110
80TQW
5C A111
5M A112
26GCA A113
38GG A114
38GT A115A
38T A116
86G A117
63C A118
51G
51VX A119
14-40 63GQ
59GX A120A
59GNX
12X A121A
12LR
46GX
A122
TEMP. REC. A123
40X A124A
64F
94E A125
A128
A129
FAN AND FUSE
MONITOR
E
E
ANNUNCIATOR
95A
P
MATCH LINE
CONTINUED AT RIGHT
SUP
A124B
SUP-
A120B
A121B
A115B
TEMP REC
P
A
SUP 9 (SIMILAR FOR SUP 10, 11 & 12)
(NOTE 2)
(D.C.CKT. 53)
AUDIBLE ALARMS WITH AUTOMATIC SILENCING
GOV. LOCK-UP CONTROLS
GOV. POWER SUPPLY SYSTEM
4C 74R S A127
2GSL GSL/LSO
74SP
A126C
A130
A131
A126B
A126A
ANN. ALARM RELAY
CONTACT (RCSETS
WITH SILENCE CONT.)
HORN RELAY
MATCH LINE
CONTINUED AT LEFT
1ATR TEST
SILENCE
RESET
1ATR1 RESET
SILENCE
TEST
2AX
M
M
W
TO HORNS
AT
AS
AR
M
M(NOTE 13)
P53 N53
P136 N136
POWER
SUPPLY
TO TRANSF 1
(PL. PE-13)
ERP1
(D.C. CKT. 36)
UNIT 1
ANN. HORN RELAY CONTACTS
GEN. 1
P35A TDPU
GEN. 2
GEN. 3
STA. SER.
LINE 1
LINE 2
(FUT.) LINE 3
AR
AR
ARAR
2A
TDC
GEN. AREA
DRAFT TUBE DECK
INTAKE DECK
SWITCHYARD
MECH. EQPT. AREA
MAIN BOARD
OSCILLATOR OC
CHIME
HORNS
OC
H I
ANNUNCIATOR
WINDOW
132-135
168-171
EXCITATION TRIP
GEN.DIFFERENTIAL
UNIT CREEPING
EXCITATION FAILURE
GOVERNOR LOCK-UP
SPARE
INCOMPLETE
SEQUENCE
GOVERNOR OIL LOW
LEVEL OR PRESSURE
TURBINE BEARING
OIL-LEVEL OR FLOW
TURB. BRG. A.C.
OIL PUMP FAILURE
TURBINE
LUBE FAILURE
GEN. BEARING LO.
OIL LEVEL
GEN. BEARING NO
COOLING WATER
NO WATER OR
HEADCOVER HI WATER
TURB.BRG.HI.TEMP.OR
OIL COOL WATER LO FLOW
GEN. COMPLETE
SHUTDOWN
GEN.EMERGENCY
SHUTDOWN
GEN. AIR
HI TEMP.
THRUST BRG. HI TEMP.
OR LOW OIL PRESS.
TURB. BEARING
HIGH TEMP.
GEN. CO
RELEASE
GENERATOR
OVERCURRENT
GEN. OR GEN.
NEUTRAL OVER VOLT.
GEN. OVER-
SPEED
GEN. PHASE
UNBALANCE
GEN. STATOR
HIGH TEMP.
FIELD OR
FIELD GROUND
SHEAR PIN, OR GATE
LOCK OPEN FAIL
EXCITATION FUSE
OR FAN
GOV.POW.SUPPLY
FAILURE
GEN. LOSS OF
PACKING BOX
GEN. AIR NO
COOLING WATER
GEN. BEARING
HI TEMP.
ACTUATING
DEVICE
EXC.TRIP RELAY
LOCKOUT RELAY
ROTATION TRANSM.
GOV. LOCK-UP
TIMER
LEVEL SWITCHES
PRESSURE SWITCH'S
FLOAT AND
FLOW SWITCHES
D.C. PUMP STARTER
LEVEL SWITCH
FLOW SWITCH
LEVEL SWITCH
D.C. MOTOR STARTER
DIAL THERMOMETERS
& FLOW SWITCHES
COMPLETE
SHUTDOWN RELAY
MATCH. FAILURE
SHUTDOWN RELAY
AIR THERMOMETER
ALARM CONTACT
BRG. TEMP. RELAY
PRESS. SWITCH
DISCHARGE
PRESS. SWITCH
OVERCURRENT
AUX. RELAY
OVER VOLTAGE
AUX. RELAYS
OVER SPEED AUX.
RELAY
PHASE BALANCE
AUX. RELAY
TEMP.RECORDER
RELAY
GR'D.OVERCURRENT RLY.
PRESS ALARM SW.
LIMIT SW.
FUSE & AIR MONITOR
(EXC. EQPT.)
GOV.POWER
SUPPLY
LOSS OF FIELD AUX.
PRESSURE SW.
BEARING TEMP.
RELAY
FLOW SWITCH
BEARING TEMP.
RELAY & RECORDER
OVER SPEED SW.
ALARM RELAY
CONTACTS OF EXC.
ANNUNCIATOR
CONTROLS
TROUBLE
CONTACT
71Q6
63Q1,Q3
71Q4
71TQS
80TQF2
71TQR
72TQP
74TL
71GQL
80WG
80WA
FOR DEVICE NUMBER,GENERAL NOTES AND EQUIPMENT LOCATION
SYMBOLS SEE PLATE PE-3.
FOR SUPERVISORY INDICATION, AUXILIARY CONTACTS OF ALL
ANNUNCIATORS SHALL BE CONNECTED INTO FOUR GROUPS
FOR UNITS,TWO GROUPS FOR STATION SERVICE SUP 62 & 97
AND ONE GROUP FOR SWITCHYARD SUP 86.
EACH ALARM CONTACT SHALL BE PROVIDED WITH AN
OPTICAL COUPLER FOR STATUS AND EVENTS RECORDING.
FOR DESCRIPTION OF EVENTS POINTS SEE PLATE PE-14.
UNIT ANNUNCIATION FOR UNITS 2 AND 3 ARE SIMILAR
TO UNIT 1, EXCEPT THAT WINDOW NUMBERS WILL BE SERIES
200 AND 300 RESPECTIVELY.
TRANSFORMER ANNUNCIATION FOR TRANSFORMERS 2 AND
3 ARE SIMILAR TO TRANSFORMER 1, EXCEPT THAT WINDOW
NUMBERS WILL BE SERIES 600 AND 700 RESPECTIVELY.
THE BELL ALARM CONTACT FOR D.C. BREAKER NO. 36,
(ANNUNCIATOR BUS) SHALL BE WIRED TO SUPERVISORY
POINT 97. ALL OTHER D.C. BREAKER BELL CONTACTS
SHALL BE WIRED TO ANNUNCIATOR POINT 410.
ANNUNCIATOR POINTS AS SHOWN FOR UNITS ARE
PARTIALLY DUPLICATED ON THE ANNUNCIATOR LAMP CABINET
ON THE OCTUATORS AND NUMBERED 151 TO 171 FOR UNIT 1.
ALL PREFERRED A.C. BELL ALARM CONTACTS SHALL BE
PARALLELED TO ANN. POINT 411.
ALL 480V. FEEDER BREAKER TRIP ALARM CONTACTS
SHALL BE PARALLELED TO ANN. POINT 428.
ANNUNCIATORS FOR LINE 2 AND FUTURE LINE 3 ARE SIMILAR TO LINE 1
EXCEPT WITH WINDOW SERIES 901-907 & 1001-1007 IN LIEU OF 808-814.
FOR ANNUNCIATOR TEST AND RESET SWITCH SEE PL. PE-4.
ALL ANNUNCIATORS (9) SHALL BE SUPPLIED FROM THEIR
OWN CIRCUIT BREAKER TAPPED FROM BUS P36. ALL NINE
CIRCUIT BREAKERS SHALL BE EQUIPPED WITH BELL ALARM
CONTACTS, WIRED IN PARALLEL AND CONNECTED TO
SUPERVISORY POINT 97.
71THC3
72THC
80TPW
TEMP.REC
63GQ
38GT
5C
5M
26GCA
38GG
86G
63C
466X
94E
74RS
23TB,23TQ
80TQW
TEMP.REC.
51VX
51G
59GX
59GNX
12LR
12X
40X
64F
74SP
GSL/LSO
SUP
EA
SUP
MC
REMARKSUP
M4
SUP
EC
UNIT 1 (NOTES 2, 5 & 9)
SUP-15
(33, 51)
OPERATES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
NOTES
A L
A R
M C
O N
T A
C T S
(N O
T E
A N
N U
N C
IA
T
IO
N
(N O
T E
A U
X
C O
N T
A C
T S
D
IO
D E
S
O P
T
IC
A L
C O
U P
L E
R S
E V
E N
T S R
E C
O R
D E
R
(N O
T E
POWERHOUSE-ELECTRICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
CONTROL SYSTEM
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PE
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
ISSUED FOR INV NO. DACW 60-78-B-0012 7/17/78
1/15/79
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
A.C.P
I.B.
G.S.L
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ANNUNCIATION SCHEMATIC-SHEET 1
PE-12
ISSUED UNDER INV. NO. DACW 60-79-B-0001
ISSUED UNDER INV. NO. DACW 60-79-B-0009
CONT. DACW 60-79-C-0002. ADDED PTS.130 & 131 (R-1)
1-26-79
6-8-79
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
WINDOW NO.
U
(N O
T E
W
IN
D O
W
N O
. ANNUNCIATION
WINDOW
ACTUATING
DEVICE
TROUBLE
CONTACT
13.8KV STA. SERV.
TRANSF. 1.0.C.
401 OVERCURRENT
AUX. RELAY
51S1X C
13.8KV STA. SERV.
TRANSF. 2.0.C.
402 OVERCURRENT
AUX. RELAY
51S2X C
480V STA. SERV.
BREAKER 1 TRIP
403 BREAKER O.L
CONTACT
52SS1 C
480V STA. SERV.
BREAKER 2 TRIP
404 BREAKER O.L
CONTACT
52SS2 C
480V STA. SERV.
BUS 1 GROUND
GND RELAY
64B1 A
480V STA. SERV.
BUS 2 GROUND
GND RELAY
64B2 A
BATTERY CHGR. 1
FAILURE
407 ALARM RELAY 74BC1 A
BATTERY CHGR. 2
FAILURE
408 ALARM RELAY 74BC2 A
INVERTER
FAILURE
409 ALARM RELAY 74I A
D.C. BREAKER
TRIP
410 BELL ALARM C
SWITCHES
(NOTE 7)
PREFERRED A.C.
BREAKER TRIP
411 BELL ALARM C
SWITCHES
(NOTE 9)
D.C. SYSTEM
GROUND
412 GR'D. OVERCURRENT A
RELAY
64-DC
PREFERRED A.C.
SYSTEM GROUND
413 GR'D. OVERCURRENT A
RELAY
64P
STATION SERV.
TRANSFORMER 1
414 TEMPERATURE A
INDICATOR
23ST1
STATION SERV.
TRANSFORMER 2
415 TEMPERATURE A
INDICATOR
23ST2
UNWAT. SUMP
WATER HI &
416 C
FLOAT SWITCHES
71U
EMERG. HI LEVEL
71USE
DRAIN. SUMP
WATER HI &
FLOAT SWITCHES
EMERG. HI OR OILY
71SL
71SLE
71SDOX
C
OIL STORAGE
ROOM CO
418 DISCHARGE C
PRESS. SWITCH
63C2
OIL PURIFICATION
ROOM CO
419 DISCHARGE C
PRESS. SWITCH
63C1
FLAMMABLE
STORAGE ROOM CO
420 DISCHARGE C
PRESS. SWITCH
63C3
STATION LO
AIR SUPPLY
421 PRESS. SWITCH A63SA
PLANT
INTRUSION
422 INTRUSION ALARM C74PI
PANEL
ABNORMAL
FREQUENCY
423 RELAY A81F-LO
81F-HI
GOVERNOR LO
AIR SUPPLY
424 PRESS. SWITCH C63GA
115 KV PHSE.
FDR. DIFF.
425 RELAY C86P
115 KV BUS
DIFF.
426 RELAY C86B
480V BUS
TIE BKR OPEN
427 BREAKER A52-BT
CONTACT
480V FEEDER
BKR. TRIP
428 BREAKER C
CONTACTS
(NOTE 10)
WASTE OIL SUMP OR
DOSING TANK
429 LEVEL SWITCH C71WOS
LEVEL SWITCH 71DT
HI LEVEL
WELL WATER TANK
LO LEVEL
430 LEVEL SWITCH A71WW
TREATED WATER
TANK LO LEVEL
431 PRESSURE-LEVEL A71TWX
CONTROLLER
UNWATERING
NEAR COMPLETE
432 UNWATERING -71U-33.5
LEVEL CONTROLLER
INSPECTION GALLERY
SUMP HI LEVEL
433 LEVEL SWITCH C71IG3
CABLE ROOM FIRE434 FIRE DETECTORS
SUP
FISH LIFT FAILURE435 TIMER 2FL A
442 SPARE
51S1X
STATION SERVICE
REMARK
(N O
T E
S
S U
P
A401
51S2X A402
52SS1-BA A403
52SS2-BA A404
64B1 A405
64B2 A406
74BC1 A407
74BC2 A408
74I A409
BELL ALARM A410
BELL ALARM A411
64DC A412
64P A413
23ST1 A414
23ST2 A415
71USE
71U A416
71SLE 435
71SL A417A
71SDOX A417B
63C2 A418
63C1 A419
63C3 A420
63SA A421
74PI
A422
81F-LO A423A
81F-HI A423B
63GA A424
86P A425
86B A426
52BT A427
A428
71WOS A429
71WW A430
71TWX A431
71U2-33.5 A432
71IG3 A433
A434
RESET
SILENCE
TEST
71U3-33.5
71U1-33.5
ERP4
SU-98
HORN
RELAY
TO HORNS
ANN. ALARM
CONTACT
P53A
P53
P436
(D.C. CKT. 36)
STATION SERVICE
AT
AS
AR
N436
(NOTE 13)
P N SUP-97
A L
A R
M C
O N
T A
C T S
A N
N U
N C
IA
T
IO
N
D
IO
D E
S
O P
T
IC
A L
C O
U P
L E
R S
E V
E N
T S R
E C
O R
D
MULTIPLE ALARM CONTACTS, NOTES 7, 9 & 10
63A
ERP5
POWER
SUPPLY
63A
TRI-21P
TRI-21B
TRI-67N
TRI-67NT
74AL
63A
(ERP7)
ERP6
POWER
SUPPLY
(D.C. CKT. 36)
LINE 1 & OCB 32
(NOTE 13)
P N
AND
TRANSFER BREAKER OCB 22 & POWERHOUSE LINE OCB 12
(NOTE 12)
P836 N836
NOTE
FOR NOTES SEE PLATE PE-12.
801 OCB 12
LOW AIR PRESSURE
PRESSURE
SWITCH
63A A
802 SPARE
803 OCB 22
LOW AIR PRESSURE
PRESSURE
SWITCH
63A A
804 SPARE
805 SPARE
806 SPARE
807 SPARE
808 LINE 1 DISTANCE
RELAY PRIMARY
LINE TRIPPING
RELAY
TIR-21P A
809 LINE 1 DISTANCE
RELAY BACK-UP
LINE TRIPPING
RELAY
TIR-21B A
810 LINE 1 CARRIER
GROUND RELAY
LINE TRIPPING
RELAY
TIR-67N A
811 LINE 1
GROUND BACK-UP
LINE TRIPPING
RELAY
TIR-67NT A
812 LINE 1 CARRIER
FAILURE
CARRIER ALARM
RELAY
74AL A
813 OCB 32
LOW AIR PRESSURE
PRESSURE
SWITCH
63A A
814 SPARE
63NS
63NT
63PR
26T1Q
49T1
71TQL1
63TPX1
86T1
51TNX1
(NOTE 12)
(D.C. CKT. 36)
TRANSFORMER 1
(NOTE 13)
N
P536 N536
SUP
OPTIONAL
COUPLERS
POWER
SUPPLY
ERP1
TO UNIT 1
(PL. PE-12)
ALARM CONTACT
ANN. AUX. CONTACTS
EVENTS RECORDER
LINE 1 & OCB 32, 22 & 12 (NOTE 11)
TRANSFORMER 1 (NOTE 6)
W
IN
D O
W
N O
. ANNUNCIATION
WINDOW
ACTUATING
DEVICE
TROUBLE
CONTACT
REMARK
(N O
T E
S
S U
P
TRANSFORMER 1 HI
OIL TEMPERATURE
TEMP. RELAY
THERMOMETER CONT.
49T1-
26TIQ
OPERATES
S 17
(35) (53)
A501
TRANSFORMER 1 LO
OIL LEVEL
OIL LEVEL SWITCH 71TQL A502
TRANSFORMER 1
SUDDEN PRESSURE
AUX. RELAY 63TPXI A503
TRANSFORMER 1
DIFF.
LOCKOUT RELAY 86TI A504
TRANSFORMER 1
NEUTRAL OVERCURRENT
TRANSF. NEUTRAL 51TNXI A505
OVERCURRENT AUX. RLY.
TRANSFORMER 1
HIGH TANK PRESSURE
PRESSURE RELIEF 63PR A506
DEVICE
TRANSFORMER 1
LOW GAS PRESSURE
SOURCE PRESS. SW 63NS A507
TANK PRESS SW. 63NT
SPARE508-
POWERHOUSE-ELECTRICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
CONTROL SYSTEM
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PE
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
ISSUED UNDER INV. NO. DACW60-79-B-0001
ISSUED FOR INV. NO. DACW60-78-B-0012 7/17/78
1/15/79
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
ACP
IB
GSL
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ANNUNCIATION SCHEMATIC-SHEET 2
PE-13
CONTRACT DACW60-79-C-0002 (R-1) 6-8-792
P
2FL
UNIT POINT NUMBER PREFIX FOR UNITS 2 & 3 CHANGES
TO 200 AND 300 SERIES
EVENT POINTS 801 TO 821 ARE SPARES PROVIDED FOR
FUTURE LINE NO. 3.
DELETED TRANSF. GND. SW., ADDED 2 GOV. AND 2 TRANSF.
POINTS. THE 2 GOV. POINTS WERE PUT ON DWG. UNDER
REVISION
CHANGED DEVICE NOS. FOR OCB'S AND SWS. TO OPERATING
1.
2.
NOTES
POWERHOUSE-ELECTRICAL
PREPARED UNDER THE SUPERVISION OF THE SAVANNAH DISTRICT
CONTROL SYSTEM
COOPER RIVER REDIVERSION PROJECT
LAKE MOULTRIE AND SANTEE RIVER SOUTH CAROLINA
PLATE
PE
SHEET
CR - PH - 01
FILE NO.INVITATION NO.SIZE
F
DACW 60
79 - B - 0001
SCALE:
SVERDRUP & PARCEL AND ASSOCIATES, INC.
ENGINEERS-ARCHITECTS
SAN FRANCISCO, CALIFORNIA
U. S. ARMY
ENGINEER DISTRICT, CHARLESTON
CORPS OF ENGINEERS
CHARLESTON, SOUTH CAROLINA
SYMBOL ZONE DESCRIPTION
REVISIONS
DATE BY
ISSUED UNDER INV. NO. DACW60-79-B-0001
ISSUED FOR INV. NO. DACW60-78-B-0012 7/17/78
1/15/79
1235 4
A
B
C
D
1235 4
A
B
C
D
DESIGN:
DRAWN:
CHECKED:
SUBMITTED:
ACP
PL
GSL
SVERDRUP & PARCEL AND ASSOCIATES, INC.
DATA AND EVENTS POINT SCHEDULE
PE-14
CONTRACT DACW60-79-C-0002, SEE NOTE 3(R-1) 6-8-792
GENERATOR 1 MWH
GENERATOR 2 MWH
GENERATOR 3 MWH
PLANT MWH "IN"
PLANT MWH "OUT"
SPARE
SPARE
STA. SERVICE #1 KWH
STA. SERVICE #2 KWH
HEADWATER LEVEL
TAILWATER LEVEL
PLANT HOURLY AVERAGE WATER FLOW
DATA LOGGER POINTS
UNIT 1, START
UNIT 1, INCOMPLETE SEQUENCE
UNIT 1, GOVERNOR LOW OIL LEVEL
UNIT 1, GOVERNOR LOW OIL PRESSURE
UNIT 1, TURB. BRG. OIL FLOW, SUMP OR RESERVOIR LEVEL
UNIT 1, TURBINE BEARING A.C. OIL PP. FAILURE
UNIT 1, TURBINE LUBE FAILURE
UNIT 1, GENERATOR BEARING LOW OIL
UNIT 1, GENERATOR BEARING COOL. WATER LOW FLOW
UNIT 1, GENERATOR AIR COOL. WATER LOW FLOW
UNIT 1, PACKING BOX NO WATER
UNIT 1, HEADCOVER HIGH WATER LEVEL
UNIT 1, TURB. BRG. TEMP. OR OIL COOL. WATER
UNIT 1, GENERATOR COMPLETE SHUTDOWN
UNIT 1, GENERATOR EMERGENCY SHUTDOWN
UNIT 1, GENERATOR AIR DISCHARGE HIGH TEMP.
UNIT 1, GENERATOR BEARINGS HIGH TEMP.
UNIT 1, THRUST BEARING HIGH TEMP.
UNIT 1, TURBINE BEARING HIGH TEMP.
UNIT 1, GENERATOR DIFFERENTIAL
UNIT 1, GENERATOR CO RELEASED
UNIT 1, GENERATOR OVERCURRENT
UNIT 1, GENERATOR OVERVOLTAGE
UNIT 1, GENERATOR OVERSPEED
UNIT 1, GENERATOR PHASE UNBALANCE
UNIT 1, STATOR HIGH TEMP.
UNIT 1, LOSS OF FIELD
UNIT 1, FILED GROUND
UNIT 1, GEN. BKR. TRIP FAILURE
UNIT 1, EXCITATION 1 FAN OR 1 FUSE FAILURE
UNIT 1, REGULATOR TRIP
UNIT 1, SPARE
UNIT 1, SPARE
UNIT 1, UNAVAILABLE
UNIT 1, THRUST BEARING LO OIL PRESSURE
UNIT 1, SHEAR PIN FAILURE
UNIT 1, GATE LOCK OPEN FAILURE
UNIT 1, CREEPING
UNIT 1, GENERATOR BREAKER CLOSED/OPEN
UNIT 1, CONTROL TRANSFER SWITCH REMOTE
UNIT 1, CONTROL TRANSFER SWITCH LOCAL-AUTO
UNIT 1, CONTROL TRANSFER SWITCH MANUAL
SPARE
SPARE
MOD 157 CLOSED/OPEN
UNIT 1, REJECTION OVERSPEED
SPARE
UNIT 1 GEN. NEUTRAL OVERVOLTAGE
SPARE
SPARE
TRANSFORMER 1 HIGH OIL TEMP.
TRANSFORMER 1 LOW OIL LEVEL
TRANSFORMER 1 SUDDEN PRESSURE
TRANSFORMER 1 DIFF. CURRENT
TRANSFORMER 1 NEUTRAL OVERCURRENT
TRANSFORMER 1 HIGH TANK PRESS
TRANSFORMER 1 LOW GAS PRESS
SPARE
SPARE
GOV. 1 LOCK-UP
GOV. 1 POW. SUP. FAILURE
SPARE
SPARE
UNITS
13.8 KV STA. SERV. TRANSF. 1 OVERCURRENT
13.8 KV STA. SERV. TRANSF. 2 OVERCURRENT
480 V STA. SERV. BREAKER 1 TRIP
480 V STA. SERV. BREAKER 2 TRIP
480 V STA. SERV. BUS 1 GROUND
480 V STA. SERV. BUS 2 GROUND
BATTERY CHARGER 1 FAILURE
BATTERY CHARGER 2 FAILURE
INVERTER FAILURE
D.C. BREAKERS TRIP
PREFERRED A.C. BREAKERS TRIP
D.C. SYSTEM GROUND
PREFERRED A.C. SYSTEM GROUND
STA. SERV. TRANSF. 1 HIGH TEMP.
STA. SERV. TRANSF. 2 HIGH TEMP.
UNWAT. SUMP WATER HI OR EMERG. HI LEVEL
DRAIN SUMP WATER HI OR EMERG. HI LEVEL
OIL STORAGE ROOM CO RELEASE
OIL PURIF. ROOM CO RELEASE
FLAMMABLES STOR. ROOM CO RELEASE
STA. AIR SUPPLY LOW PRESSURE
PLANT INTRUSION
GOVERNOR AIR SUPPLY LOW PRESSURE
COMMON ANNUNCIATION SUPPLY BREAKER TRIP
ACB 812 REMOTE/LOCAL CONTROL
ACB 812 TRIP FAILURE
13.8 KV ACB 812 CLOSED/OPEN
ACB 822 REMOTE/LOCAL CONTROL
ACB 822 TRIP FAILURE
13.8 KV ACB 822 CLOSED/OPEN
480 V ACB 814 CLOSED/OPEN
480 V ACB 824 CLOSED/OPEN
480 V ACB 830 CLOSED/OPEN
FREQUENCY LOW
FREQUENCY HIGH
115 KV POWERHOUSE LINE DIFF.
115 KV BUS DIFF.
DRAINAGE SUMP WATER OILY
480 V FEEDER BREAKERS TRIP
WASTE OIL SUMP HI LEVEL
WELL WATER TANK LO LEVEL.
TREATED WATER TANK LO LEVEL
UNWATERING NEAR COMPLETION
INSPECTION GALLERY SUMP HI LEVEL
CABLE FIRE DETECTORS
SWITCHYARD REMOTE/LOCAL
SPARE
SPARE
SPARE
SPARE
STATION SERVICE
SPARE
SPARE
SPARE
SPARE
OCB 128 AUTOMATIC TRIP
OCB 128 LOW AIR PRESSURE
OCB 128 CLOSED/OPEN
OCB 128 RELAY TRANSFER TO OCB 22
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
OCB 118 AUTOMATIC TRIP
OCB 118 LOW AIR PRESSURE
OCB 118 CLOSED/OPEN
MOD 101 CLOSED/OPEN
SPARE
SPARE
SPARE
SWITCHYARD
SPARE
SPARE
SPARE
OCB 148 RELAY TRANSFER TO OCB 22
OCB 148 AUTOMATIC TRIP
OCB 148 LOW AIR PRESSURE
OCB 148 CLOSED/OPEN
OCB 148 RECLOSER ON/OFF
LINE 1 DISTANCE RELAY PRIMARY
LINE 1 DISTANCE RELAY BACK UP
LINE 1 CARRIER GROUND RELAY
LINE 1 GROUND BACK UP
LINE 1 CARRIER FAILURE
LINE 1 GROUND SW. 145 OPEN/CLOSED
SPARE
SPARE
SPARE
MOD 137 CLOSED/OPEN
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
OCB 248 RELAY TRANSFER TO OCB 22
OCB 248 AUTOMATIC TRIP
OCB 248 LOW AIR PRESSURE
OCB 248 CLOSED/OPEN
OCB 248 RECLOSER ON/OFF
LINE 2 DISTANCE RELAY PRIMARY
LINE 2 DISTANCE RELAY BACK UP
LINE 2 CARRIER GROUND
LINE…