CADD CODE: M015FR84
CONSTRUCTION PLANS FOR
SOLICITATION NO. (W9127818R0008)
NOVEMBER 2017
OKALOOSA COUNTY
FLORIDA
DRAWINGS IN THIS FOLIO HAVE BEEN
REDUCED TO ONE HALF THE ORIGINAL SCALE
CONSTRUCT FOREIGN MILITARY SALES FACILITY
Mobile District of Engineers
US Army Corps
BUILDING STRONG
CONSTRUCTION OF
EGLIN AIR FORCE BASE, FLORIDA
AMENDMENT NO.0001
AutoCAD SHX Text R
AutoCAD SHX Text R a a a a a
LEGEND: WIND LOADS
ZONE 1 ROOFS / 4 WALLS
ZONE 2 ROOFS / 5 WALLS
ZONE 3 ROOFS
NOTES:
1. BASIC WIND SPEED = 141 MPH
2. WIND EXPOSURE = "C"
3. OCCUPANCY CATEGORY II
4. "ENCLOSED STRUCTURE"
5. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY
FROM THE SURFACES, RESPECTIVELY.
6. THE INDICATED SIMPLIFIED BUILDING DIAGRAMS ARE FOR ILLUSTRATIVE
PURPOSES ONLY AND ARE NOT INTENDED TO EXACTLY MATCH ACTUAL
BUILDING SHAPE.
7. TOTAL COMPONENTS AND CLADDING PRESSURE IS EQUAL TO THE
COMBINATION OF THE EXTERNAL AND INTERNAL PRESSURE
(qH(GCp-GCpi)).
8. WIND LOADS ARE CALCULATED AND BUILDINGS ZONES ARE DEFINED IN
ACCORDANCE WITH ASCE 7-10.
9. ROOF OVERHANG NOT SHOWN FOR CLARITY BUT VALUES ARE SPECIFIED
WITH OH IN WIND LOAD TABLES.
COMPONENTS AND CLADDING SCHEDULE
LOCATION 10 SF 50 SF 100 SF
ZONE 1 28.91 PSF
-50.11 PSF
28.91 PSF
-84.09 PSF
28.91 PSF
-126.59 PSF
50.11 PSF
-54.37 PSF
27.72 PSF
-48.05 PSF
27.21 PSF
-47.16 PSF
27.72 PSF
-77.17 PSF
27.21 PSF
-74.19 PSF
27.72 PSF
-116.17 PSF
13.92 PSF
-49.89 PSF
27.21 PSF
-111.69 PSF
41.26 PSF
-47.97 PSF
NOTES:
1. ALL WIND LOADS LISTED ARE BASED ON ULTIMATE DESIGN WIND SPEED
PER ASCE 7-10. FOR BUILDINGS WITH h ≤ 160 FT (TABLE 30.7-2).
ZONE 2
ZONE 3
ZONE 4
45.85 PSF
-84.09 PSF
40.19 PSF
-70.25 PSF
37.75 PSF
-64.29 PSFZONE 5
20 SF
28.40 PSF
-49.22PSF
28.40 PSF
-81.11 PSF
28.40 PSF
-122.10 PSF
47.44 PSF
-52.44 PSF
43.41 PSF
-78.13 PSF
500 SF
26.102 PSF
-45.10 PSF
26.02 PSF
-67.27 PSF
26.02 PSF
-101.27 PSF
35.08 PSF
-43.49 PSF
32.09 PSF
-50.45 PSF
US Army Corps of Engineers ®
SHEET ID
U.
S.
A
RM
Y
CO
RP
S
O F
EN
G
IN
EE
RS
DR
AW
N
BY
DE
SI
G N E
D
BY
SU
BM
IT
TE
D
BY
SI
ZE
CH
EC
K E D
BY
AN
SI
D
FI
LE
N
A M E:
IS
SU
E D A
TE
CO
NT
R A
CT
N O
SO
LI
CI
T A
TI
O
N
NO
PR
O
JE
C T
N
UM
BE
R:
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
DE
SC
R I
PT
IO
N
S-001
C O
NS
TR
UC
T
FO
R E
IG
N M
IL
IT
AR
Y
SA
LE
S
FA
CI
LI
TY
M
O
BI
LE
D
IS
TR
IC
T
S.
E
LL
ZE
Y
D.
G
RI
FF
IN
G . W
HI
G
HA
M
J.
O
RT
IZ
NO
VE
M
BE
R
W
8R
M
5F R8
AMENDMENT 001
EG
LI
N
AF
B, F
LO
R I
DA
M O
BI
LE
, A
LA
BA
M
A
G
EN
ER
A L
S
TR
UC
TU
RA
L
NO
TE
S, D
ES
IG
N L O
AD
S
AB
BR
EV
IA
TI
O
NS
CONCRETE
1. STRUCTURAL CONCRETE FOR THE BUILDING STRUCTURE SHALL HAVE A MINIMUM COMPRESSIVE
STRENGTH AT 28 DAYS AS FOLLOWS:
FOOTINGS, GRADE BEAMS:.............................................................................................................f'c = 4,000 PSI
CONCRETE STEM WALLS, ARMS VAULT
AND CAST-IN-PLACE CONCRETE WALLS:.....................................................................................f'c = 4,000 PSI SLABS ON GRADE AND METAL DECK:...........................................................................................f'c = 4,000 PSI
2. ALL REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 GRADE 60 UNLESS
NOTED OTHERWISE.
3. LOCATION OF ALL CONCRETE JOINTS, OTHER THAN THOSE SPECIFIED, SHALL BE APPROVED BY THE
CONTRACTING OFFICER BEFORE CONCRETE PLACEMENT.
4. MINIMUM PROTECTIVE COVER OF REINFORCEMENT (SEE DETAILS) SHALL BE AS FOLLOWS:
CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ....................................................................3"
EXPOSED TO EARTH OR WEATHER
#6 OR LARGER..............................................................................................................................................2" #5 OR SMALLER.......................................................................................................................................1 1/2"
5. MINIMUM CONCRETE SPLICES AND HOOKS FOR REINFORCING STEEL SHALL CONFORM TO ACI 318, CURRENT EDITION.
6. CONCRETE WORK SHALL BE COORDINATED WITH DRAINS, UNDERGROUND UTILITIES, MECHANICAL, ELECTRICAL, AND ARCHITECTURAL PLANS. CONCRETE SHALL NOT BE CAST UNTIL THESE ITEMS HAVE BEEN
INSTALLED AND ACCEPTED.
7. CONCRETE FINISHES SHALL BE PROVIDED AS DESCRIBED IN THE SPECIFICATIONS.
8. CORNER BARS SHALL BE PROVIDED AT ALL INTERSECTIONS; BAR SIZE AND SPACING TO MATCH LARGER
BAR.
9. SLABS ON GRADE SHALL BE REINFORCED AT ALL PENETRATIONS AND RE-ENTRANT CORNERS. PLACE 3, # 4 x 3'-0" AROUND FLOOR DRAINS. PLACE 2-#4 x 4'-0 (MINIMUM) AT RE-ENTRANT CORNERS.
AB
ABV.
ALT.
APPROX.
ARCH.
B
BLDG.
B/STL
BOT
BRKT.
BRNG.
C.L.
CIP
CJ
CL.
COE
COL.
CONC.
CMU
CONN.
CONT.
DET.
DIA.
DIM.
do
DR
DWG.
E.
E.F.
E.W.
EA.
EL. (HEIGHT)
ELEV. (VIEW)
EQ.
EQUIP.
EXIST.
EXP. JT.
FS
F.D.
F.F.
FAB.
FDN.
FIG.
FIN. FL.
FIN. GR.
FL.
FLG
FRMG.
FT.
FTG.
GALV.
H.R.
HEX.
HGR.
HORIZ.
HT.
I.F.
INCL.
INV.
JST.
JT.
LLH.
LLV
LVR.
MCJ
M.O.
MAT'L.
AND
AT
ANCHOR BOLT
ABOVE
ALTERNATE
APPROXIMATE
ARCHITECTURAL
BEAM
BUILDING
BOTTOM OF STEEL
BOTTOM
BRACKET
BEARING
CENTERLINE
CAST-IN-PLACE
CRACK CONTROL JOINT
CLEAR/CLEARANCE
CORPS OF ENGINEERS
COLUMN
CONCRETE
CONCRETE MASONRY UNIT
CONNECTION
CONTINUE/CONTINUOUS
DETAIL
DIAMETER
DIMENSION
DITTO
DRAIN
DRAWING
EAST
EACH FACE
EACH WAY
EACH
ELEVATION
ELEVATION
EQUAL
EQUIPMENT
EXISTING
EXPANSION JOINT
FOOTING STEP
FLOOR DRAIN
FAR FACE
FABRICATE
FOUNDATION
FIGURE
FINISH FLOOR
FINISH GRADE
FLOOR
FLANGE
FRAMING
FOOT
FOOTING
GALVANIZE
HANDRAIL
HEXAGON
HANGER
HORIZONTAL
HEIGHT
INSIDE FACE
INCLUDE/INCLUSIVE
INVERT
JOIST
JOINT
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LOUVER
MASONRY CONTROL JOINT
MASONRY OPENING
MATERIAL
MAX.
MECH.
MFR.
MIN.
MISC.
N.
N.F.
N.T.S.
NO.
NSL.
O.C.
OPNG.
OPP.
O/F O/H
PED.
P.E.J.
PEMB
PERP.
PL.
PLATF.
PLF
PRELIM.
PROJ.
PT.
PVC
PVMT.
QTY.
R.
RD
REF.
REINF.
REQD.
R.F.
S
SCHED.
SECT.
SF
SHT.
SIM.
SLV.
SPCG.
SPEC.
SQ.
SST.
SP
STA.
STD.
STIFF.
STL.
S. FTG.
STR.
SUPT.
SYMM.
T&B
TE
TOC
TOF
T/STL
T/WALL
TEMP.
TS
THK.
TYP.
MAXIMUM
MECHANICAL
MANUFACTURE
MINIMUM
MISCELLANEOUS
NORTH
NEAR FACE
NOT TO SCALE
NUMBER
NORMAL SLOT LENGTH
ON CENTER
OPENING
OPPOSITE
OUT FACE
OVERHANG
PEDESTAL
PREMOLDED EXPANSION JOINT
PRE-ENGINEERED METAL BUILDING
PERPENDICULAR
PLATE
PLATFORM
POUNDS PER FOOT
PRELIMINARY
PROJECTION
POINT
POLYVINYL CHLORIDE
PAVEMENT
QUANTITY
RADIUS
ROAD
REFERENCE
REINFORCE
REQUIRED
RIGID FRAME
SPLICE
SCHEDULE
SECTION
SWAY FRAME
SHEET
SIMILAR
SHORT LEG VERTICAL
SPACING
SPECIFICATION
SQUARE
STAINLESS STEEL
SPACE
STATION
STANDARD
SIFFERNER
STEEL
STEPPED FOOTING
STRAIGHT
SUPPORT
SYMMETRICAL
TOP AND BOTTOM
THICKENED EDGE
TOP OF CONCRETE
TOP OF FOOTING
TOP OF STEEL
TOP OF WALL
TEMPERATURE
THICKENED SLAB
THICKNESS
TYPICAL
COLD-FORMED STEEL FRAMING AND LIGHT GAGE METAL FRAMING FOR HIGH ROOF
1. ALL COLD FORMED FRAMING SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE AISI
"COLD FORMED STEEL DESIGN MANUAL."
2. ALL COLD-FORMED STEEL FRAMING SHALL BE FORMED FROM STEEL THAT CONFORMS TO THE
REQUIREMENTS OF ASTM A-653.
3. ALL COLD-FORMED STEEL FRAMING, CONNECTORS, ETC. SHALL RECEIVE A G-60 GALVANIZED COATING.
4. CONTRACTOR SHALL SUBMIT CALCULATIONS AND SHOP DRAWINGS FOR DETAILING, FABRICATION AND ERECTION OF LIGHT GAUGE STEEL MEMBERS. CALCULATIONS AND DRAWINGS SHALL CLEARLY INDICATE SPACING, TYPE, MATERIAL, MEMBER PROPERTIES, BRACING AND CONNECTIONS FOR LIGHT GAUGE STEEL
AND BRACING SYSTEMS.
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AFFECTING THE WORK AT JOBSITE.
COORDINATE THE LOCATION AND DIMENSIONS OF GROOVES, REGLETS, SLEEVES, OPENINGS, AND EMBEDDED OR ATTACHED ITEMS, REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PIPING DRAWINGS.
2. ALL STRUCTURAL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE PROJECT
SPECIFICATIONS.
3. PROVIDE TEMPORARY BRACING AND SHORING OF THE STRUCTURE AND COMPONENTS UNTIL ALL COMPONENTS ARE ERECTED AND ALL CONNECTIONS ARE FULLY MADE, AS NECESSARY, TO INSURE STABILITY DURING CONSTRUCTION. BRACE ALL WALLS DURING CONSTRUCTION AGAINST WIND AND/OR CONSTRUCTION
LOADS.
4. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [67'-6"]. SEE CIVIL DRAWINGS FOR THE ACTUAL DATUM ELEVATION.
5. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCES.
6. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE CONTRACTING OFFICER'S
REPRESENTATIVE PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE AFFECTED.
7. ELECTRICAL CONDUIT AND PLUMBING SHALL NOT PENETRATE FOOTINGS AND GRADE BEAMS.
STRUCTURAL DESIGN CRITERIA:
1. BUILDING CODES, STANDARDS, AND SPECIFICATIONS:
UFC 1-200-01 (JUNE 2016) GENERAL BUILDING REQUIREMENTS
UFC 3-301-01 (JUNE 2013) STRUCTURAL ENGINEERING, w/ CHANGE 3 UFC 3-310-04 (JUNE 2013) SEISMIC DESIGN FOR BUILDINGS, w/ CHANGE 1 UFC 4-010-01 (FEBRUARY 2012) DoD MINIMUM ANTITERRORISM STANDARDS FOR
BUILDINGS w/ CHANGE 3
ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
ACI 318-14 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
AISC MANUAL OF STEEL CONSTRUCTION, 14th EDITION
AISC SEISMIC DESIGN MANUAL, SECOND EDITION
TMS 402 - 213 BUILDING CODE AND SPECIFICATIONS FOR MASONRY STRUCTURES
IBC-2015 INTERNATIONAL BUILDING CODE
2. STRUCTURAL DESIGN LOADS:
A. DEAD LOADS
ACTUAL WEIGHTS OF MATERIALS USED
B. LIVE LOADS: REDUCIBLE PER BUILDING CODE
ROOF LIVE LOADS.....................................................................................................20 PSF CORRIDORS.............................................................................................................. 80 PSF STAIRS AND EXITWAYS............................................................................................100 PSF OFFICE SPACES (INCLUDE PARTITIONS)...................................................................65 PSF LOBBIES..................................................................................................................100 PSF MECHANICAL AND STORAGE ROOMS.....................................................................125 PSF
C. SNOW LOADS
GROUND SNOW LOAD...........................................................................................Pg = 0 PSF
C. WIND LOADS
BASIC WIND SPEED, V..............................................................................................141 MPH EXPOSURE CATEGORY........................................................................................................C
INTERNAL PRESSURE COEFFICIENTS:
FMS BUILDING...............................................................................Gcpi = +/- 0.18 (ENCLOSED)
D. SEISMIC LOADS
RISK CATEGORY................................................................................................................. II IMPORTANCE FACTOR, I.....................................................................................................1.0 SITE (SOIL) CLASS.................................................................................................................D
Ss........................................................................................................................................0.09g S1........................................................................................................................................0.05g Fa............................................................................................................................................1.6 Fv ............................................................................................................................................2.4 Sds.......................................................................................................................................0.09g Sd1........................................................................................................................................0.08g SEISMIC DESIGN CATEGORY..................................................................................................B
SEISMIC FORCE RESISTING SYSTEM: ORDINARY REINFORCED MASONRY SHEER WALLS
SEISMIC RESPONSE MODIFICATION FACTOR...................................................................R = 2 SEISMIC RESPONSE COEFFICIENT........................................................................Cs = 0.045 W
SEISMIC ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
FOUNDATION DESIGN
A. SITE PREPARATION:
1. EXCAVATION AND BACKFILL SHALL BE IN ACCORDANCE WITH THE CONTRACT DRAWINGS AND
SPECIFICATIONS.
2. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICERS REPRESENTATIVE WHEN LOOSE OF SOFT SOILS
ARE EXPOSED WHERE SLABS OR FOOTINGS ARE TO BE PLACED.
3. CAPILLARY WATER BARRIER SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH THE DRAWINGS AND
SPECIFICATION SECTION 31 00 00.
4. OVEREXCAVATION AT COLUMN FOOTINGS:
SEE SITE DRAWINGS FOR EXCAVATION/FILL REQUIREMENTS. BACKFILL ALL OVEREXCAVATIONS WITH
COMPACTED, SATISFACTORY FILL PER SPECIFICATION SECTION 31 00 00.
5. BACKFILL AROUND FOUNDATION WALLS SHALL BE PLACED ON EACH SIDE OF THE WALL IN EQUAL LIFTS.
B. FOUNDATION DESIGN CRITERIA BASED ON GEOTECHNICAL REPORT PREPARED BY MOBILE DISTRICT CORPS
OF ENGINEERS.
ABBREVIATIONS: GENERAL NOTES:
U.N.O.
VAR.
VERT.
W.W.F.
w/ W/O
WP
UNLESS NOTED OTHERWISE
VARIABLE
VERTICAL
WELDIED WIRE FABRIC
WITH
WITHOUT
WORKING POINT
STRUCTURAL STEEL
1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST AISC
SPECIFICATIONS AND CODE OF STANDARD PRACTICE.
2. STEEL FABRICATION SHALL CONFORM TO FOLLOWING REQUIREMENTS UNLESS NOTED OTHERWISE. NO STRUCTURAL STEEL SHALL BE FABRICATED OR ERECTED UNTIL SHOP DRAWINGS HAVE BEEN APPROVED.
MISCELLANEOUS PLATES AND ANGLES - ASTM A36 (Fy=36 KSI) RECTANGULAR HSS - ASTM 500, GRADE B (Fy= 46 KSI)
"W" SHAPES - ASTM A992 GRADE 50
3. NO HOLES OTHER THAN THOSE SPECIFICALLY DETAILED SHALL BE ALLOWED THROUGH STRUCTURAL STEEL MEMBERS. CUTTING OF STEEL SHALL NOT BE PERMITTED WITHOUT APPROVAL OF THE CONTRACTING
OFFICER'S REPRESENTATIVE.
4. NO STRUCTURAL STEEL SHALL BE FABRICATED OR ERECTED UNTIL SHOP DRAWINGS HAVE BEEN
APPROVED.
5. THE CONTRACTOR SHALL VERIFY ALL SHOP DRAWING DIMENSIONS WITH THE STRUCTURAL AND
ARCHITECTURAL PLANS AND DETAILS, AND WITH FIELD DIMENSIONS OF COLUMN LAYOUT.
6. BOLTED CONNECTIONS SHALL BE MADE WITH HIGH STRENGTH BOLTS CONFORMING TO ASTM A325, 3/4" DIAMETER MINIMUM UNLESS NOTED OTHERWISE.
7. ALL WELDS SHALL BE MADE USING E70XX ELECTRODES AND SHALL BE AS REQUIRED BY CONNECTION
DESIGN, BUT IN NO CASE LESS THAN 3/16".
8. STANDARD SHEAR CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED BY THE FABRICATOR.
CONNECTIONS SHALL BE SELECTED TO SUPPORT ONE HALF OF THE TOTAL UNIFORM LOAD CAPACITY SHOWN IN THE LRFD LOAD TABLES OF THE LATEST AISC MANUAL FOR THE GIVEN BEAM, SPAN, AND GRADE
OF STEEL SPECIFIED. WHERE POSSIBLE, DOUBLE ANGLE CONNECTIONS SHALL BE USED.
9. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE A36.
10. ALL SHOP AND FIELD WELDING SHALL CONFORM TO THE STRUCTURAL WELDING CODE AWS
D1.1, LATEST EDITION, PUBLISHED BY THE AMERICAN WELDING SOCIETY (AWS). SHOW ALL SHOP WELDS ON
THE FABRICATION DRAWINGS AND ALL FIELD WELDS ON THE ERECTION DRAWING.
5. FABRICATOR IS RESPONSIBLE FOR THE DESIGN AND DETAILING OF ALL LIGHT GAGE FRAMING AS SHOWN ON DRAWINGS. ALL COMPONENTS AND CONNECTIONS SHALL BE DESIGNED BY QUALIFIED ENGINEER REGISTERED IN THE STATE OF FLORIDA. ALL LIGHT GAUGE FRAMING SHALL BE DESIGN FOR THE FOLLOWING SUPERIMPOSED
LOADS:
ROOF:
DEAD LOAD.......................................................................................................................................15 PSF
LIVE LOAD............................................................................................................-............................20 PSF
WIND DESIGN LOADS SHALL CALCULATED IN ACCORDANCE WITH ASCE 7-10, LIGHT GAUGE ROOF FRAMING.
6. IN ADDITION TO THE LOADS INDICATED ABOVE, LIGHT GAUGE ROOF FRAMING SHALL BE DESIGNED FOR ANY CONCENTRATED LOADS FROM MECHANICAL, ELECTRICAL OR ARCHITECTURAL ITEMS. REFER TO THE MECHANICAL, ELECTRICAL, AND ARCHITECTURAL DRAWINGS FOR LOAD INFORMATION AND LOCATIONS.
7. ALL LIGHT GAUGE FRAMING SHALL BE A MINIMUM OF 6" IN DEPTH.
8. MAXIMUM CENTER TO CENTER SPACING SHALL BE 2'-0".
9. ALL COMPONENTS AND CONNECTIONS SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER CURRENTLY LICENSED IN THE STATE OF FLORIDA. ALL CONNECTIONS AND SUPPORT CONNECTIONS INDICATED
ON THE DRAWINGS ARE TO BE DESIGNED A QUALIFIED DESIGN ENGINEER.
10. CONTRACTOR SHALL SUBMIT CALCULATIONS AND SHOP DRAWINGS FOR DETAILING, FABRICATION AND ERECTION OF LIGHT GAUGE STEEL MEMBERS. CALCULATIONS AND DRAWINGS SHALL CLEARLY INDICATE SPACING, TYPE, MATERIAL, MEMBER PROPERTIES, BRACING AND CONNECTIONS FOR LIGHT GAUGE STEEL AND
BRACING SYSTEMS.
M
AR
K
DA
TE
AM
EN
D M
EN
T
R
EV
IS
ED
F O
U N
D
AT
IO
N
D
ES
IG
N
N O
TE
/1
2/
STEEL JOISTS
1. STEEL JOIST SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST
SPECIFICATIONS OF THE STEEL JOIST INSTITUTE.
2. BRIDGING INDICATED ON CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF ILLUSTRATING MISCELLANEOUS ATTACHMENTS AND DETAILS. GREATER OR FEWER LINES OF BRIDGING MAY BE REQUIRED BY STEEL JOIST
INSTITUTE. THESE REQUIREMENTS SHALL SUPERCEDE THE CONTRACT DOCUMENTS.
3. ALL JOISTS SHALL BE CAMBERED IN ACCORDANCE WITH RECOMMENDATIONS AND SPECIFICATIONS OF THE
STEEL JOIST INSTITUTE.
4. PROVIDE STABILITY BRACING FOR JOISTS IN ACCORDANCE WITH STEEL JOIST INSTITUTE RECOMMENDATIONS
AND OSHA REQUIREMENTS.
5. IN STEEL FRAMES, WHERE COLUMNS ARE NOT FRAMED IN AT LEAST TWO DIRECTIONS WITH STRUCTURAL STEEL MEMBERS, JOISTS AT OR NEAREST COLUMN CENTERLINE SHALL BE FIELD BOLTED AT THE COLUMNS TO PROVIDE
LATERAL STABILITY DURING CONSTRUCTION.
6. WHERE THE JOIST SPAN EXCEEDS THE UNSHADED AREA OF THE LOAD TABLE, THE ROW OF BRIDGING NEAREST THE MID SPAN SHALL BE DIAGONAL BRIDGING WITH BOLTED CONNECTIONS AT THE CHORDS AND INTERSECTIONS.
METAL DECKING
1. STEEL DECK SHALL BE ERECTED IN ACCORDANCE WITH MANUFACTURER'S AND STEEL DECK INSTITUTE
RECOMMENDATIONS AND SPECIFICATIONS.
2. STEEL DECK PROPERTIES AND ATTACHMENTS SHALL BE IN ACCORDANCE WITH THE STEEL DECK
INSTITUTE.
3. GALVANIZING SHALL CONFORM TO ASTM A924-94 WITH A MINIMUM COATING CLASS OF G-60.
4. DECK TO BE INSTALLED CONTINUOUS OVER A MINIMUM OF (3) SUPPORTS.
5. LIGHT GAGE METAL FRAMING, SUSPENDED CEILING, LIGHT FIXTURES, DUCTS AND OTHER UTILITIES
SHALL NOT BE SUPPORTED BY METAL ROOF DECKING.
6. PROVIDE MINIMUM L4x4x1/4 FRAMING AROUND ALL OPENINGS LARGER THAN 6 INCHES FOR ROOF TOP
MECHANICAL UNITS.
7. FOR DECK UNITS WITH METAL THICKNESS LESS THAN 0.028 INCHES (22 GAGE) WELD DECK THROUGH MANUFACTURER'S STANDARD WELDING WASHERS WITH SPECIFIED WELD PATTERN OR AS SHOWN ON
DRAWINGS.
A
SEAL WALL TIGHT TO
STRUCTURE, TYP.
DEFLECTION
TRACK SYSTEM
FIN. FLR
1 HR FIRE RATED
TYPE A1
FIRE STOPPING, TYP.
STC 49
GENERAL NOTES:
1. FIRE RATED AND SOUND RATED WALLS EXTEND TO UNDERSIDE OF
STRUCTURAL DECK ABOVE. PROVIDE CLOSURE FOR FIRE STOP
AND ACOUSTICAL SEAL AT CORRUGATIONS.
2. HIGH IMPACT RESISTANT GYPSUM WALLBOARD SHALL BE
INSTALLED IN STORAGE, TOOL ROOMS, SUPPLY ROOM, AND SHOP.
3. MOISTURE RESISTANT GYPSUM WALLBOARD SHALL BE USED IN
BREAK AREA, RESTROOMS, ETC. WHERE GYPSUM WALLBOARD IS
EXPOSED TO MOISTURE.
4. TYPE X GYPSUM WALLBOARD SHALL BE USED @ ALL FIRE RATED
ASSEMBLIES.
5. 6" BATT INSULATION ABOVE FINISHED CEILINGS (TYP.)
B C
STRUCTURE ABOVE
8" CMU
8" BOND BEAM
5/8" TYPE X
GYPSUM BOARD
DEFLECTION GAP
SEAL WALL TIGHT TO
STRUCTURE, TYP.
STRUCTURE ABOVE
FIRE STOPPING, TYP.
7/8" FURRING
CHANNEL
5/8" TYPE X GYPSUM
BOARD, BOTH SIDES
3 5/8" METAL STUD
20 GA @ 24" O.C.
3 1/2" ACOUSTICAL
BATT INSULATION
SEAL WALL TIGHT TO
STRUCTURE, TYP.
1/2" CEMENTITIOUS BOARD
PORCELAIN TILE,
SEE FINISH SCHEDULE
D
STRUCTURE ABOVE
CEILING
SEE SCHEDULE
CEILING
SEE SCHEDULE
CEILING
SEE SCHEDULE
CEILING
SEE SCHEDULE
E
5/8" TYPE X
GYPSUM WALL BOARD
3 5/8" METAL STUD
20 GA @ 24" O.C.
3 1/2" MINERAL WOOL
BATT INSULATION
FASTENED TO
PREVENT SLIDING
DOWN AND LEAVING A
VOID AT THE TOP
UL DESIGN NO. U419
SEAL WALL TIGHT TO
STRUCTURE, TYP.
B1
5/8" TYPE X
GYPSUM BOARD
6" METAL STUD
6" ACOUSTICAL
BATT INSULATION
5/8" TYPE X
GYPSUM BOARD
1/2" CEMENTITIOUS BOARD
TYPE B1 ONLY
PORCELAIN TILE, SEE
FINISH SCHEDULE
TYPE B1 ONLY
UL DESIGN NO. U910
8" CMU
8" BOND BEAM
5/8" TYPE X
GYPSUM BOARD,
WALL TYPE D ONLY
DEFLECTION GAP
STRUCTURE ABOVE
FIRE STOPPING, TYP.
7/8" FURRING CHANNEL,
WALL TYPE D ONLY
CEILING
SEE SCHEDULE
CEILING
SEE SCHEDULE
D1
1/2" CEMENTITIOUS BOARD,
TYPE E1 ONLY
PORCELAIN TILE
SEE FINISH SCHEDULE
TYPE E1 ONLY
E1
UL DESIGN NO. U443
STC 58
5/8" TYPE X
GYPSUM BOARD,
3 5/8" METAL STUD
3 1/2" ACOUSTICAL
BATT INSULATION
SEAL WALL TIGHT TO
STRUCTURE, TYP.
1/2" CEMENTITIOUS
BOARD
PORCELAIN TILE
SEE FINISH SCHEDULE
F H STC 44
REQ. ON SECOND
FLOOR ONLY
8'
0" T
O T
O P
O F
W
AL
L
CONTINUOUS TRACK AT
TOP AND BOTTOM
ANCHORS AT 32" O.C. MAX
2 BEADS CONTINUOUS
ACOUSTICAL SEALANT
CONTINUOUS TRACK AT
TOP AND BOTTOM
ANCHORS AT 32" O.C. MAX
2 BEADS CONTINUOUS
ACOUSTICAL SEALANT
CONTINUOUS TRACK AT
TOP AND BOTTOM
ANCHORS AT 32" O.C. MAX
2 BEADS CONTINUOUS
ACOUSTICAL SEALANT
CONTINUOUS TRACK AT
TOP AND BOTTOM
ANCHORS AT 32" O.C. MAX
2 BEADS CONTINUOUS
ACOUSTICAL SEALANT
FIRE STOPPING, TYP.
FIRE STOPPING, TYP.
FIRE STOPPING, TYP.
DEFLECTION TRACK SYSTEM
DEFLECTION
TRACK SYSTEM
INTERIOR WALL TYPES
G
FIN. FLR
FIRE STOPPING, TYP.
STC 50
CEILING
SEE SCHEDULE
3 5/8" METAL STUD
16 GA @ 16" O.C.
3 1/2" MINERAL WOOL BATT
INSULATION, FASTENED TO
PREVENT SLIDING DOWN
AND LEAVING A VOID AT THE
TOP
PER IDC 705
SEAL WALL TIGHT TO
STRUCTURE, TYP.
CONTINUOUS TRACK AT
TOP AND BOTTOM
ANCHORS AT 32" O.C. MAX
2 BEADS CONTINUOUS
ACOUSTICAL SEALANT
BOTH SIDES OF WALL
5/8" TYPE X
GYPSUM WALL BOARD
ENTIRE WALL
ASSEMBLY SHALL BE
FINISHED AND PAINTED
FROM TRUE FLOOR TO
BOTTOM OF DECK
2 BEADS CONTINUOUS
ACOUSTICAL SEALANT
BOTH SIDES OF WALL
A1 STC 49
MIN 1-HOUR FIRE RATED
WHERE NOTED ON DRAWINGS
UL DESIGN NO. U907
TYPE D
UL DESIGN NO U914
TYPE D1
7'
- 0
TY
P
7'
0" T
YP
7'
0" T
YP
S1
8" CAST IN PLACE
CONCRETE
5/8" TYPE X
GYPSUM BOARD
DEFLECTION GAP
SEAL WALL TIGHT TO
STRUCTURE, TYP.
STRUCTURE ABOVE
FIRE STOPPING, TYP.
7/8" FURRING
CHANNEL
S2
CEILING
SEE SCHEDULE
S3
MIN. 2-HOUR RATING
PER ACI 216.1
8" CAST IN PLACE
CONCRETE
5/8" TYPE X
GYPSUM BOARD
DEFLECTION GAP
SEAL WALL TIGHT TO
STRUCTURE, TYP.
STRUCTURE ABOVE
FIRE STOPPING, TYP.
7/8" FURRING CHANNEL
CEILING
SEE SCHEDULE
CEILING
SEE SCHEDULE
STRUCTURE ABOVE
CEILING
SEE SCHEDULE
SEAL WALL TIGHT TO
STRUCTURE, TYP.
5/8" TYPE X
GYPSUM BOARD
3" METAL
FURRING
8" CAST IN PLACE
CONCRETE
2 1/2" METAL
FURRING
5/8" TYPE X
GYPSUM BOARD
MIN. 2-HOUR RATING
PER ACI 216.1
MIN. 2-HOUR RATING
PER ACI 216.1
FIRESTOPPING, TYP.
DEFLECTION GAP
CONCRETE WALL TYPES
X1
1'
4" 8"
8" 0"
1/
2"
1/ 2"9" 5"
8" CMU
AIR SPACE
SPLIT-FACE
CMU VENEER
GLAZED CMU
COURSE
PRECAST
CONCRETE CAP
EXTERIOR WALL TYPES
US Army Corps of Engineers ®
SHEET ID
U.
S.
A
RM
Y
CO
RP
S
O F
EN
G
IN
EE
RS
DR
AW
N
BY
DE
SI
G N E
D
BY
SU
BM
IT
TE
D
BY
SI
ZE
CH
EC
K E D
BY
AN
SI
D
FI
LE
N
A M E:
IS
SU
E D A
TE
CO
NT
R A
CT
N O
SO
LI
CI
T A
TI
O
N
NO
PR
O
JE
C T
N
UM
BE
R:
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
DE
SC
R I
PT
IO
N
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
A-601
C O
NS
TR
UC
T
FO
R E
IG
N M
IL
IT
AR
Y
SA
LE
S
FA
CI
LI
TY
M
O
BI
LE
D
IS
TR
IC
T
M . D
UN
N
M . D
UN
N
G . W
HI
G
HA
M
J.
M
. C
HI
LD
S
NO
VE
M
BE
R
W
8R
M
5F R8
AMENDMENT 0001
M O
BI
LE
, A
LA
BA
M
A
W
AL
L
TY
PE
S
AD
D
ED
N
O
TE
R
EG
AR
D
IN
G
W
AL
L
TY
PE
H
M
AR
K
DA
TE
AM
EN
D M
EN
T
/2
S O
LI
C
IT
A
TI
O
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
TI
O
N
M
AR
K S
IZ
E
S U
B M
IT
TE
D B
Y
D A
TE
C O
N
TR
A C
T N
O
C H
EC
KE
D B
Y:
D R
A W
N B
Y
IS
S
U E
D A
TE
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
FU
R
N
IT
U R
E , F
IX
TU
R
ES
A N
D E
Q U
IP
M
E N
T
LE
G
EN
D
N O
VE
M
B E
R
R . C
A
LH
O U
N
J.
S
U B
M
IT
TE
R
M
5F R
C
A D
D C
O D
E:
S . C
A M
P
BE
LL
S . H
E R
N
AN
D
EZ
E G
LI
N
A
IR
F O
R C
E B
A S
E , F
LO
R
ID
A
C O
N S
TR
U
C T
FO
R
E
IG
N M
IL
IT
A R
Y S
A
LE
S F
A C
IL
IT
Y
I-001
A N
S I D
M
5F R
P
R O
JE
C
T N
U M
B E
R
W
8R
AMENDMENT 0001
UP
R
EF
R
EF
MW
(2) ICE
D W
S O
LI
C
IT
A
TI
O
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
TI
O
N
M
AR
K S
IZ
E
S U
B M
IT
TE
D B
Y
D A
TE
C O
N
TR
A C
T N
O
C H
EC
KE
D B
Y:
D R
A W
N B
Y
IS
S
U E
D A
TE
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
S O
LI
C
IT
A
TI
O
N N
O
D E
S
IG
N E
D B
Y
S
IZ
E
S U
B M
IT
TE
D B
Y
C O
N
TR
A C
T N
O
C H
EC
KE
D B
Y:
D R
A W
N B
Y
IS
S
U E
D A
TE
C A
D D
C O
D E:
FI
R
S T
FL
O
O R
F F&
E P
LA
C
E M
E N
T P
LA
N
M
5F R
S . C
A M
P
BE
LL
S . H
E R
N
AN
D
EZ
R . C
A
LH
O U
N
E G
LI
N
A
IR
F O
R C
E B
A S
E , F
LO
R
ID
A
C O
N S
TR
U
C T
FO
R
E
IG
N M
IL
IT
A R
Y S
A
LE
S F
A C
IL
IT
Y
I-101
N O
VE
M
B E
R
A N
S I D
M
5F R
P
R O
JE
C
T N
U M
B E
R
W
8R
S O
LI
C
IT
A
TI
O
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
TI
O
N
M
AR
K S
IZ
E
S U
B M
IT
TE
D B
Y
D A
TE
C O
N
TR
A C
T N
O
C H
EC
KE
D B
Y:
D R
A W
N B
Y
IS
S
U E
D A
TE
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
E G
LI
N
A
IR
F O
R C
E B
A S
E , F
LO
R
ID
A
C O
N S
TR
U
C T
FO
R
E
IG
N M
IL
IT
A R
Y S
A
LE
S F
A C
IL
IT
Y
S
EC
O N
D F
LO
O
R F
F& E
P
LA
C E
M E
N T
P
LA
N
I-102
R . C
A
LH
O U
N
J.
S
U B
M
IT
TE
R
M
5F R
C
A D
D C
O D
E:
S . C
A M
P
BE
LL
S . H
E R
N
AN
D
EZ
A N
S I D
M
5F R
P
R O
JE
C
T N
U M
B E
R
N O
VE
M
B E
R
W
8R
BFP-1
1" CW
FD
FD
P-9
D
B
A
C
B.3
BFP-3
SCWP-1
SCWP-1A PCWP-1
WATER
METER
DWBP-1
2 1/2"
DOMESTIC WATER
BUILDING ENTRANCE
COORDINATE WITH
UTILITY DRAWINGS
2 1/2"
3/4"
ET-1
1"
2 1/2"
2"
1"
FCU-14
FCU-15
FCU-12
ELECTRICAL
COMMUNICATIONS
ROOM
LAB STORAGE
AIDEWS #2 LAB
AIDEWS LAB
116C
CORR
WAREHOUSE
MECHANICAL
SIPR ROOM
EAST
WEST
DS-4DS-3
DS-2
CDS-2 CDS-3 CDS-4
CDS-6 CDS-7CDS-5
BFP-4
SF-1
SF-2
OFFSET FOR
CLARITY
AS-2
BP-1
AS-1
1"
1"
ISO VALVE
SMART GAS METER
SEE SPECIFICATIONS
FOR DETAILS
FIRE RISER
P-301
ISO VALVE
ISO VALVE
ISO VALVE
ISO VALVE
SPRINKLER PIPE
PWCP-2
COORDINATE
WITH OKALOOSA
GAS COMPANY
DIELECTRIC BREAK
OAU-1
P-9
FS
FS
FS
FS
FD
FD
UP TO 2ND
FLOOR
FIXTURES
3/4" TO ELECTRONIC TRAP PRIMER
WITH ISOLATION VALVE IN DROP
2"
PLAN NORTH
EAST KEY PLAN
E A S T
ALL METALLIC PENETRATIONS THROUGH WALLS SEPARATING THE SECURE /
NON-SECURE AREAS SHALL BE INSTALLED AS FOLLOWS:
1. METAL CONDUIT OR PIPE PENETRATIONS-- PROVIDE A PVC
DIELECTRIC BREAK OR A NO. 4 COPPER WIRE GROUNDED TO THE
BUILDING'S GROUND WITHIN SIX (6) INCHES OF THE SECURE
PERIMETER PENETRATION.
2. METALLIC SPRINKLERS (FIRE SUPPRESSION) PIPING--PROVIDE A UL-
LISTED DIELECTRIC UNION INSIDE THE SECURED PERIMETER
ADJACENT TO THE PENETRATION OR A GROUND TO THE PIPE
PENETRATION WITHIN 6" OF THE SECURED SIDE PERIMETER
PENETRATION USING A NO.4 COPPER WIRE TO THE BUILDING
GROUND. SEAL BOTH SIDES OF THE PERIMETER SECURED WALL
PENETRATION WITH AN ACOUSTICAL FOAM SEALANT OR SEALANT
FINISHED TO MATCH ADJACENT WALL, FLOOR, OR CEILING.
3. MECHANICAL SYSTEM REFRIGERANT LINES-- PROVIDE A NO. 4
COPPER WIRE GROUNDED TO THE BUILDING'S GROUND WITHIN SIX
(6) INCHES OF THE SECURE PERIMETER PENETRATION. THIS
INCLUDES PENETRATIONS OF EXTERIOR WALLS INTO SECURE
AREAS.
4. HVAC DUCTS-- PROVIDE A NONCONDUCTIVE BREAK (FLEX
CONNECTION) FOR A TWO (2) TO SIX (6) INCH SECTION OF DUCT
INSIDE THE SECURE PERIMETER ADJACENT TO THE PENETRATION
( SEE DETAIL 6 SHEET M-504).
5. SEAL BOTH SIDES OF ALL PERIMETER PENETRATIONS WITH AN
ACOUSTICAL FOAM OR SEALANT, FINISHED TO MATCH ADJACENT
WALLS, FLOORS, OR CEILINGS.
6. MAINTAIN THE INTEGRITY OF ALL PIPE INSULATED WHEN INSTALLING
COPPER GROUND WIRE.
7. REFERENCE ARCHITECTURAL SHEET A-130 FOR SECURE AREA
LOCATIONS
SECURITY WALL PENETRATIONS:
AC-1
AC-2
1MW NATURAL GAS GENERATOR
SMART GAS METER
SEE SPECIFICATION FOR
DETAILS
GAS ISOLATION
VALVE 3" 2-PSI GAS LINE
COORDINATE WITH OKALOOSA
GAS COMPANY
EQUIPMENT YARD
US Army Corps of Engineers ®
SHEET ID
U.
S.
A
RM
Y
CO
RP
S
O F
EN
G
IN
EE
RS
DR
AW
N
BY
DE
SI
G N E
D
BY
SU
BM
IT
TE
D
BY
SI
ZE
CH
EC
K E D
BY
AN
SI
D
FI
LE
N
A M E:
IS
SU
E D A
TE
CO
NT
R A
CT
N O
SO
LI
CI
T A
TI
O
N
NO
PR
O
JE
C T
N
UM
BE
R:
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
DE
SC
R I
PT
IO
N
G . S
TA
U B
G . S
TA
U B
W . K
NA
PP
P-108
C O
NS
TR
UC
T
FO
R E
IG
N M
IL
IT
AR
Y
SA
LE
S
FA
CI
LI
TY
M
O
BI
LE
D
IS
TR
IC
T
NO
VE
M
BE
R
W
8R
- M
5F R8
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
M O
BI
LE
, A
LA
BA
M
A
DO
M
ES
TI
C W
AT
E R
E
AS
T
FI
R S T
FL
O
O R
PL
AN
1/8" = 1'-0"1 DOMESTIC WATER EAST 1ST FLOOR PLAN
SCALE:
0 8' 16'
1/8" = 1' - 0"
8' 16'
M
AR
K
DA
TE
AM
EN
D M
EN
T
/2
1/8" = 1'-0"2 NATURAL GAS GENERATOR OPTION 4
NA
TU
RA
L
GA
S
L
OC
AT
IO
NS
| XCOVER |
| _AM 0001_COMBINED DRAWINGS 1 |
| _AM 0001_COMBINED DRAWINGS 3 |
| _AM 0001_COMBINED DRAWINGS 4 |
| _AM 0001_COMBINED DRAWINGS 5 |
| _AM 0001_COMBINED DRAWINGS 6 |
| _AM 0001_COMBINED DRAWINGS 7 |
File details come from the government source that posted it.