CAS_0514_BID_SCHEDULE.pdf
PDF 22 KB Posted
- Attached to
- BUTTE MEPS GRAPHICS Federal contract opportunity
- Solicitation number
- W91236-16-T-0040
About this file
Bid Schedule
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CAS_0514_SOW.docx.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUTTE MEPS GRAPHICS PACKAGE- BUTTE, MONTANA- BID SCHEDULE- AS OF 13 JULY 2016
***Dimensions provided are estimates. Contractor responsible for field measuring site.
*** For bidding purposes, assume existing wall surfaces are vinyl wall covering throughout facility.
***All acrylic shall be non- glare and edges shall be polished smooth.
*** All graphics are to be designed and provided by Contractor. All graphics must be approved by User. Reselection may be required after submittal is reviewed by User.
ID TAG LOCATION DESCRIPTION QTY UNIT COST TOTAL COST
A VISITOR LOUNGE/WAITING Provide and install a custom designed, digital printed wall covering (approximately 16'6" x 9'0"); Wall covering shall completely cover wall from corner to corner or stop at an acceptable breaking location. Wall covering shall run from top of wall base to ceiling grid. Walls shall be prepped and primed to accept wall covering. Final wall graphic shall be protected with a sealed coating applied over the wall covering. Coating shall be a water based polyurethane applied in two coats using a back rolling method with a mohair roller or equal protection application to protect against scratches/dents/damages.
B VISITOR LOUNGE/WAITING Provide and install a custom designed, digital printed wall covering (approximately 13'6" x 9'0"); Wall covering shall completely cover wall from corner to corner or stop at an acceptable breaking location. Wall covering shall run from top of wall base to ceiling grid. Walls shall be prepped and primed to accept wall covering. Final wall graphic shall be protected with a sealed coating applied over the wall covering. Coating shall be a water based polyurethane applied in two coats using a back rolling method with a mohair roller or equal protection application to protect against scratches/dents/damages.
C THROUGHOUT FACILITY Provide and install a non-glare acrylic/PVC panel measuring 48” wide by 32 - 36” high, 1/4" thick. Each panel shall have a digital graphic image fused onto the back of the acrylic layer and shall be mounted to the wall using four (4) stainless steel stand-off hardware brackets. 10
D OVERHEAD SIGNS FOR DIVISIONS Provide and install an overhead identity sign; ceiling mounted hanging from SAPC ceiling in corridors; aluminum and wood laminate finishes to match building finishes; 8"-9" raised metal/acrylic lettering in capitals to read to name of the division, double sided; securely attached to ceiling with typical installation method; approximate overall dimensions of 10" high x 48" wide x 1/2" thick; Divisions include
"OPERATIONS", "COMMAND SUITE", "LIAISONS", "TESTING", "MEDICAL".
E MEDICAL WAITING Provide and install a custom designed, digital printed wall covering (approximately 15'9" x 9'0"); Wall covering shall completely cover wall from corner to corner or stop at an acceptable breaking location. Wall covering shall run from top of wall base to ceiling grid. Walls shall be prepped and primed to accept wall covering. Final wall graphic shall be protected with a sealed coating applied over the wall covering. Coating shall be a water based polyurethane applied in two coats using a back rolling method with a mohair roller or equal protection application to protect against scratches/dents/damages.
F THROUGHOUT FACILITY Provide and install a frame with overall dimensions of 36” wide x 24” high, ¼” thick, non-glare acrylic/PVC. Photo/image print shall be the same size as the plaque and shall be fused onto the back of the panel surface. Secure to wall with four (4) stainless steel stand offs. Apply to existing wall. 38
G LOGO STICKER OF ETCHED
GLASS/COLOR ON COMMAND
SUITE DOOR
Provide and install a 20" diameter vinyl appliqué, with an etched glass appearance or in full color, applied directly to the door. Logo shall be a MEPCOM logo. 1
H ABOVE THE FRONT DESK CHECK IN
COUNTER
Provide and install 10” high, 1/4" thick, three-dimensional, upper case, letters with a brushed stainless steel finish. Font shall be Arial Bold. Letters shall be all capitals and read “WELCOME TO BUTTE MEPS”. Install, flush mount, over existing wall finish. 18
I CEREMONY ROOM DEDICATION
PLAQUE
Provide a framed shadow box with biography and story awards; frame shall have a clear acrylic/glass/ wood finish stained to match/ complement the wood stain and species in the ceremony room/ through the facility; Photo and written biography shall be provided by installers; awards provided by MEPS shall be incorporated in the collage which may have different depths for interest; frame shall be approximately 4' x 3';
security apparatus shall be used to ensure frame is not removable by applicants.
J FRAMES FOR OATHS /DIRECTIONS
FOR MEDICAL PROCEDURES
Provide and install a poster holder with 2 layers of 1/4" thick clear acrylic and hardware; Image to be provided by User prior to installation; Contractor to print image and provide in final poster holder; poster holders shall be installed on to existing wall with brushed stainless off-sets/chrome edge grips; Panel approximately 48" high x 36" wide x 1/2" thick. 8
K BOOT PRINTS ON ORTHO ROOM
FLOOR
Provide and install a vinyl image/appliqué on existing VTC floor. Each vinyl image/appliqué shall simulate a set of boot prints. 8" high image shall coordinate with the color of the interior finishes. Material shall be applicable for foot traffic and shall be slip resistant. 40
L ENTRANCE OF EACH LIAISON
OFFICES
Provide and install a non-glare acrylic/PVC panel 66” high x 30” wide x 1/4" thick. Image shall be fused to the back side of 1/4" thick acrylic with polished edges. Image on each panel shall include service logo/seal on the top portion, the creed in the center portion, and the ranking within each branch on the bottom portion. Panels shall be installed to existing wall with six (6) chrome edge grips or stainless steel stand offs. Each panel should represent one of each of the service branches to include: Army, Navy, Air Force, Marines, National Guard.
M CEREMONY ROOM Provide and install a 15-18" diameter hard plastic/strofoam, three diminsional, color seal; securely mounted to the existing wall. Seals include: Army, Air Force, Navy, Marines, National Guard. 5
N MAIN CHECK IN COUNTER Provide and install a 20" diameter vinyl appliqué, color seals applied directly to the face of the reception counter. Seals include: Army, Air Force, Navy, Marines, National Guard, and MEPS Logo. 6
O MAIN CORRIDOR Provide and install 6" high three-dimensional, 1/4" thick, upper case letters with a brushed stainless steel finish. Font shall be Arial Bold. Letters shall be all capitals and read “CHAIN OF COMMAND”. Install, flush mount, over existing wall finish. 14
P EMERGENCY EXIT Provide and install a frame consisting of two (2) pieces of 8.5"x11" clear acrylic with polished edges with computer printed emergency exit diagrams provided by Users. Mount to wall with four (4) chrome edge grips. 15
PRODUCT SUB TOTAL
Site Visit Graphic Design Shipping and Delivery Install and Project Management
GRAND TOTAL FOR BASE BID
File details come from the government source that posted it. Updated .