This document is a Statement of Work (SOW) for the procurement of seven industrial-strength, walk-behind battery-powered sweepers for indoor use at the Anniston Army Depot. The key requirements include:
The sweepers must be 24V battery-powered with on-board recharging capabilities, capable of cleaning up to 43,000 sq ft per charge, and equipped with a direct throw type main tubular brush, side brush, and vacuum dust control system. Additional requirements specify hopper capacity, noise level, size, gradeability, and other salient characteristics. The equipment will undergo acceptance testing and verification at the Anniston Army Depot, and the contractor must provide comprehensive documentation, including operator and maintenance manuals, spare parts lists, and other standard documentation. The equipment is covered by a 12-month or 2,000-hour warranty.
The related federal contract opportunity is Solicitation Number W911KF24Q0039 issued by the Department of the Army Materiel Command Contracting Command Detroit Arsenal for the procurement of these electric sweepers.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W911KF24Q0039 Amendment 04.pdf | ||
| Requirements Memo Technical Lit Electric Sweepers Rev 1.pdf | ||
| W911KF24Q0039-03.pdf | ||
| W911KF24Q0039 Amendment 02.pdf | ||
| W911KF24Q0039 Amendment 01.pdf | ||
| W911KF24Q0039.pdf | ||
| DD Form 1423 - CDRL.pdf | ||
| Requirements Memo (Technical Lit) Electric Sweepers.pdf | ||
| Statement of Work - Sweepers DP.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sweeper Statement of Work
Request (7) Industrial-strength walk-behind sweepers for indoor use in machine shop and welding bays.
1.0 Salient characteristics required: Walk Behind Sweepers
1.1 Sweeper shall be 24V battery-powered system with on bard re-charging capabilities (utilizing standard 110Volt outlet).
1.2 Capable of cleaning up to 43000 sq ft per charge
1.3 Sweeper shall be direct throw type with the main tubular brush of 26 in minimum.
1.4 Sweeper shall be equipped with a side brush (17in) in addition to the main tubular brush and shall have a vacuum dust control system with at least a 1 Horse Power fan motor.
1.5 Dust control system shall include a high efficiency filter (to minimum 0.3 micron filtration) with a 95% efficiency to contain dust generation. Filter should be equipped with auto shaking to remove dust from filter extending filter use life upon equipment shut off.
1.6 Walk behind shall have self-propelled forward and reverse movement. Hopper shall have mechanical lever hopper dump and be removable to enable dump into waste drum.
1.7 Hopper capacity shall be a minimum of 2.8 cubic feet and hold up to 150lbs.
1.8 Equipment operation sound level shall be less than 75 decibels.
1.9 Equipment shall be a minimum 36 inches width, 63 inches minimum length and have a minimum Aisle turn of 68 inches.
1.10 Minimum sweeping path shall be no less than 34 inches
1.11 Grade ability of equipment shall be at least 7 degrees with an empty hopper and 5 degrees with full hopper to allow movement over variable surfaces.
1.12 Sweeper shall have a steel front bumper to protect the machine from incidental contact with equipment/walls.
2.0 Acceptance Testing and Verification: The equipment shall be tested and verified after delivery to Anniston Army Depot, Anniston, AL 36201.
3.0 Conformance: The equipment shall meet the requirements of this Specification and conform to the Manufacturer’s own drawings, specifications, standards, and quality assurance practices. The government reserves the right to, at any time during the contract period, require proof of such conformance or to inspect the equipment to determine compliance with the requirements of this Specification.
4.0 Preliminary Acceptance: The government will provide a preliminary acceptance for date of equipment delivery to Anniston Army Depot. This preliminary acceptance requires that all equipment components, accessories and documentation are delivered to Anniston Army Depot and have been inspected for shipping damage by the government.
5.0 Final Acceptance: The government will issue a final acceptance only after the contractor successfully completes all requirements herein. Final acceptance will be at Anniston Army Depot. Upon acceptance of all items described above, the contractor shall submit a completed DD Form 250 for signature by the government representative, as final acceptance of the equipment required by this specification.
6.0 Delivery, Handling, Storage and Installation:
6.1 Delivery: The Contractor shall be responsible for delivering the equipment to Building 55 at Anniston Army Depot, 7 Frankford Avenue, Anniston, Alabama, 36201.
7.0 Documentation and Delivery: The Contractor shall provide documentation with each piece of equipment as specified herein and on the attached DD Form 1423. The documentation shall be delivered with the equipment or as required herein.
7.1 Quantity: The Contractor shall provide two (2) printed copies and one (1) electronic copy of all documentation to include all maintenance and operators manuals.
7.2 Electronic File Format: Electronic copies of the documentation shall be in Adobe Portable Document Format (PDF). Drawings and schematics may be provided in PDF or Microstation (.dgn) format.
7.3 Operator Manuals: An Operator Manual shall be furnished to include operating instructions explaining preventive maintenance procedures, methods of checking the machine for normal safe operation and procedures for safely starting and stopping the system manually. The Operator Manual shall include the step-by-step procedures required for machine startup, operation and shutdown.
7.4 Maintenance Manuals: Maintenance manuals shall include electrical, hydraulic, and pneumatic schematics, as applicable, detailed lockout/tag out procedures, parts lists, troubleshooting procedures, preventive maintenance requirements, lubrication schedule and any other maintenance procedures normally provided by the Contractor. Schematics shall show and identify all parts. Schematic diagrams showing equipment utilized, including motor horsepower and voltage; starter; isolators; manual bypasses; tubing sizes; drain piping and drain traps;
reducing valves; and data on manufacturer's names and model numbers, mounting, access, and clearance requirements. Data shall include calculations of all utility consumption.
7.5 Spare Parts List: Spare Parts Lists shall be furnished complete with OEM part numbers, National Stock Numbers (if applicable), part descriptions, and required quantities.
7.6 Other Documentation: In addition, any other documentation normally furnished with the machine shall be provided.
7.7 Language: All documentation shall be furnished in the English language only.
7.8 Government Furnished Equipment (GFE): Anniston Army Depot will furnish no government owned equipment to the Contractor.
8.0 Warranty: The Equipment shall be covered by a warranty. The warranty shall be for a period of not less 12 months or 2,000 hours, whichever comes first. The warranty shall begin on the date of final acceptance. Warranty shall be in the name of Anniston Army Depot.