This document provides details for a federal contract solicitation for construction services. The solicitation is for a project called Beddown Global ASNT involving repair and renovation of 550 square feet in room 1083 of a Command Post facility. The scope of work requires the contractor to provide all material, equipment, labor and supervision to complete a usable space. Key project roles of Project Manager, Quality Control and Superintendent may not be subcontracted below the Prime Contractor. A Critical Path construction schedule is due five days after award. The work will take place on a secure military facility requiring background checks. The estimated value is between $500,000 and $1,000,000. Bid and payment/performance bonds are required. Offerors must be registered in SAM at time of bid opening. A pre-bid conference will be held on August 27, 2020 at the specified location.
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER SHEET
AND DRAWING INDEX
GI001
DRTH
EXISTING CONDITIONS &
DEMOLITION
CU-101
RPSF
PLAN
NORTH
SITE PLAN
CU-102
RPSF
CIVIL
SECTIONS AND DETAILS
CU-103
RPSF
STRUCTURAL
ABBREVIATIONS AND NOTES
S-001
NOTES
S-002
STRUCTURAL
SITE PLAN
SS101
PLATFORM FRAMING
PLANS, SECTIONS & DETAILS
S-101
RPSF
PARTIAL PLAN & ENLARGED PLAN
S-102
RPSF
S-501
S-502
Galvanized Post Outside
Diameter
Wall thickness Yield
Strength in
PSI
Corner Post 6.625 inch 0.280 inch 30,000
Minimum
End Post 6.625 Inch 0.280 inch 30,000
Minimum
Pull Post 4.500 inch 0.237 inch 30,000
Minimum
Line Post 2.875 inch 0.203 inch 30,000
Minimum
SCH 40
OF FENCE PLATFORM.
AIR NATIONAL GUARD REFERENCED
FENCE DETAILS - SHEET 1 OF 4
MAIN ASSEMBLY
F-510
AIR NATIONAL GUARD REFERENCED
FENCE DETAILS - SHEET 2 OF 4
DETAIL VIEWS
F-511
AIR NATIONAL GUARD REFERENCED
FENCE DETAILS - SHEET 3 OF 4
POSTS & OUTRIGGER
F-512
NEW FENCE POST
THE EXISTING
FENCE CONFIGURATION
FENCE
NON
SENSORED
AIR NATIONAL GUARD REFERENCED
FENCE DETAILS - SHEET 4 OF 4
WIRE & TRANSITION DETAILS
F-513
MECHANICAL
ABBREVIATIONS, NOTES
& SYMBOLS
M-001
JVTH
Increment 2
Cabinet
PDSC
MEC
EA Cell
MC
NNC
NNC
MC
JBOX
MDU
MECHANICAL
HVAC PLANS
DEMOLITION AND NEW WORK
MH-101
JVTH
MECHANICAL
PIPING PLAN
MP-101
JVTH
| 0_General |
| GI001 |
| GI001 |
| 1_Civl |
| CU-101 |
| CU-101 |
| Site |
| CU-102 |
| CU-102 |
| Site |
| CU-103 |
| CU-103 |
| S-501 |
| 2_Structural |
| S-001 |
| S-001 |
| S-001 |
| S-002 |
| S-001 |
| S-002 |
| SS101 |
| SS101 |
| SS101 |
| S-101 |
| S-101 |
| S-101 |
| S-102 |
| S-102 |
| S-102 |
| S-501 |
| S-501 |
| S-501 |
| S-502 |
| S-501 |
| S-502 |
| F-510 |
| F-510 |
| F-510 |
| F-511 |
| F-510 |
| F-511 |
| F-512 |
| F-510 |
| F-512 |
| F-513 |
| F-510 |
| F-513 |
| 6_Mechanical |
| M-001 |
| M-001 |
| MP-001 |
| MH-101 |
| MH-101 |
| MH-101 |
| MP-101 |
| MP-101 |
| MP-101 |
| Electrical |
| E-001 |
| E-002 |
| E-101 |