This document contains a schedule and supplemental drawings for replacing the security camera surveillance system at the Memphis VA Medical Center. The schedule lists existing and new cameras by building and floor, along with the number of fixed, PTZ, and total cameras. It also notes several existing systems that will remain in use and be connected to the new surveillance control center. The related federal contract opportunity is solicitation number 36C24920R0074_1 to replace the security camera surveillance system, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The description specifies replacing the security camera surveillance system at the Memphis VA Medical Center.
View the file
Other files for this federal contract opportunity
Show all 33
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Camera Schedule
Building Description Floor Switch Enclosure/Rack Location Fixed PTZ Total
R New R New R New
1 Administration G – Ground Electric Closet GB 0 8 0 2 0 10
1 Administration G – Ground SCC CEG4 0 3 0 4 0 7
1 Administration G – Ground Electric Closet 11 0 9 0 1 0 10
1 Administration 1 – First Electric Closet AW1E2 (b) 0 35 0 3 0 38
1 Administration 1 – First Electric Closet CW173 0 3 0 3 0 6
1 Administration/AC 1 – First Electric Closet 6115 (g) 0 25 0 0 0 25
1 Administration 2 – Second Electric Closet at Elevators P8 & P9 (c) 16 3 0 0 16 3
1 Administration 2 – Second Electric Closet CW207 24 6 0 1 24 7
1 Administration 3 – Third Electric Closet at Elevators P6 & P7 0 0 0 0 0 0
1 Administration 4 – Fourth Electric Closet CW424 0 0 0 0 0 0
1A Bed Tower G – Ground Comm Closet GB1110 (d) 10 19 0 1 10 20
1A Bed Tower 1 – First Electric Closet G107 0 4 0 1 0 5
1A Bed Tower 2 – Second Electric Closet G234 0 2 0 1 0 2
1A Bed Tower 3 – Third Electric Closet G336 0 1 0 1 0 2
1A Bed Tower 4 – Fourth Electric Closet G430 0 0 0 1 0 1
1A Bed Tower 5 – Fifth Electric Closet G536 0 0 0 1 0 1
5 Clinic Annex G – Ground Electric Closet 5152 0 0 0 2 0 2
5 Clinic Annex 1 – First Telephone Closet 5260 0 0 0 1 0 1
5 Clinic Annex 2 – Second Mechanical Room 0 2 0 0 0 2
7 Spinal Cord Injury B – Basement Electric Closet BB100 0 1 0 1 0 2
7 Spinal Cord Injury B – Basement Electric Closet BC101 0 1 0 1 0 2
7 Spinal Cord Injury 1 – First Electric Closet 1B100 0 4 0 1 0 5
7 Spinal Cord Injury 1 – First Electric Closet 1C101 0 3 0 1 0 5
7 Spinal Cord Injury 2 – Second Electric Closet 2B100 0 4 0 2 0 6
7 Spinal Cord Injury 2 – Second Electric Closet 2C101 0 0 0 1 0 1
10 Engineering 1 – First Electric Shop 0 0 0 0 0 0
15 Parking Garage 1 – First Utility Closet 1 (e) 30 0 10 0 40 0
Site (a) South Lot 0 0 0 3 0 3
Site (a) East Lot 0 0 0 2 0 2
Site (a) West Lot 0 0 0 2 0 2
Site (a) Building 1 0 1 0 9 0 10
Site (a) Building 1/AC 0 4 0 2 0 6
Site (a) Building 1A (d) 2 2 0 4 2 6
Site (a) Building 5 0 1 0 3 0 4
Site (a) Building 7 0 0 0 5 0 5
Site (a) Building 9 0 1 0 0 0 1
Site (a) Building 10 0 2 0 1 0 3
82 144 10 61 92 205
Notes: All camera locations are existing; only those identified as New are existing cameras to be replaced with new cameras.
(a) Use existing path for exterior cameras to enter building and run cabling to nearest switch location on floor
(b) Provide Ward 1C/D new local monitoring and recording capability, provide multi-mode fiber connection back to new SCC
(c) Existing Residential Unit 2C and 2D equipment and cameras to remain and be reused, provide multi-mode fiber connection back to new SCC
(d) Existing Bed Tower cameras to remain and be reused - Site locations at entrance canopy; Building locations ground floor
Lobby area, Stair, Agent Cashier, Travel
(e) Existing Parking Garage equipment and cameras to remain and be reused; extend and terminate existing fiber in CEG4 at new SCC equipment
(f) Existing VCS equipment and cameras to remain and be reused; provide multi-mode fiber connection back to new SCC
(g) Provide Emergency Department cameras in high security type enclosure; (4) Psych and (2) Security Hold
Drawing Legend R-Remain/Reuse Fixed PTZ NVR Switch Enclosure/Rack
New Fixed PTZ NVR Switch Enclosure/Rack
Employee Parking 110 spaces
Employee Parking 110 spaces
Resident parking 43 spaces 33
5 21
LEGEND
1 Administration Building and Ambulatory Care
1A Bed Tower (Seismic/Modernization Addition) 5 Clinic Annex 6 Utility 7 Spinal Cord Injury 8 Propery 10
9 MRI
10 Engineering Shops
0 50' 100' 150' 200' 400 FT
VAN/CAR
VAN/CAR
VAN/CAR
VAN/CAR
VAN/CAR
VAN/CAR
VAN/CAR
VAN/CAR
CAR
CAR
VAN/CAR
VAN/CAR
VAN/CAR
VAN/CAR
PARKING GARAGE
15 x30x10
Ground Floor
Podiatry
Prosthetics
Women's Center Medical Specialty Clinic
Engineering Shops
Radiation Oncology
Release of Information
Medical Records
Police & Security
Warehouse
SPS
Inpatient Pharmacy
Engineering
AFGE
Research & Development
NAGE
P
C&P
Elevator
Stairs
N
S
EW
Main Lobby
TravelAgent Cashier
Occupational Health
P
Pathology
Ambulance Entrance 1st Floor
Emergency Entrance 1st Floor
Bed Tower Entrance
Ground Floor
Clinic Annex Women's Center
Entrances Ground Floor
Spinal Cord Injury Unit Entrance 2nd Floor
East Parking Lot
West Parking Lot
Smoking Shelter
Smoking Shelter
Hypertension
EMS
Administration Bldg Entrance
1st Floor
Staff Entrance 1st Floor
Outpatient Pharmacy
Service Officers
Veterans
Eligibility
Voluntary
Logistics
Business Office
GB
CEG4
GB1110x10
BC101 BB100
1st Floor
Dental Physical Therapy
Occupational Therapy
Outpatient Lab
Orthopedic
Ward 1C/D
MRI
Emergency
Ward 1EWard 1W
Surgical Specialty Clinic
Audiology and Speech Pathology ENT Nuclear
Medicine
Inpatient X-Ray
Outpatient X-Ray
Women's Center
Stone Center
P
GU
Cysto Urology
Elevator
Stairs
N
S
EW
Eye Center
EKG
Patient Rep
Central Check-In
Copper Clinic
IRM
CT
Ultrasound
Emergency Check-In
P Blue Firm
Ambulance Entrance 1st Floor
Emergency Entrance 1st Floor
Bed Tower Entrance
Ground Floor
Clinic Annex Women's Center
Entrances Ground Floor
Spinal Cord Injury Unit Entrance 2nd Floor
East Parking Lot
West Parking Lot
Smoking Shelter
Smoking Shelter
Mental Health ClinicQM
Administration Bldg Entrance
1st Floor
Staff Entrance 1st Floor
PET/CT
MHICM
Department
Social Work
AW1E2
CW173
G107
1C101 1B100
2nd Floor
Spinal Cord Rehab
Outpatient ClinicPVA
MICU
Ward 2S
Theater
Vending
Nutrition and Food Kitchen
Neuropsychology
Chapel
Chaplain
Medical Library
Credit Union
Recreation Therapy
Nursing
HRMS Amb.
Care
P
Executive Office
Cardiology Check-In
CICU
Elevator
Stairs
N
S
EW
Cafeteria
Retail Store
P
Classrooms
Ambulance Entrance 1st Floor
Emergency Entrance 1st Floor
Bed Tower Entrance
Ground Floor
Clinic Annex Women's Center
Entrances Ground Floor
Spinal Cord Injury Unit Entrance 2nd Floor
East Parking Lot
West Parking Lot
Smoking Shelter
Smoking Shelter SCI Pharmacy
Residential Unit 2C and 2D
Ward 2E (Temporary)
Administration Bldg Entrance
1st Floor
Staff Entrance 1st Floor
OEF/OIF/OND
PTSD Clinic
Mental Health x16
EC
CW207
x24
VCS
Retail Store Food Court
G234
MECHANICAL
2C101
2B100
3rd Floor
SICUWard 3F
Vascular Lab Ambulatory
Surgery
Surgical Service
Operating Room
Recovery
P
Elevator
Stairs
N
S
EW
P Ambulance Entrance 1st Floor
Emergency Entrance 1st Floor
Bed Tower Entrance
Ground Floor
Clinic Annex Women's Center
Entrances Ground Floor
Spinal Cord Injury Unit Entrance 2nd Floor
East Parking Lot
West Parking Lot
Smoking Shelter
Smoking Shelter
3E GI Lab
Administration Bldg Entrance
1st Floor
Staff Entrance 1st Floor
EC
G336
4th Floor
Ward 4E
Dialysis
Hematology/ Oncology
P
Elevator
Stairs
N
S
EW
P Ambulance Entrance 1st Floor
Emergency Entrance 1st Floor
Bed Tower Entrance
Ground Floor
Clinic Annex Women's Center
Entrances Ground Floor
Spinal Cord Injury Unit Entrance 2nd Floor
East Parking Lot
West Parking Lot
Smoking Shelter
Smoking Shelter
4F Social Work
OEF/OIF
Customer Svc
Medical Service
Education
Administration Bldg Entrance
1st Floor
Staff Entrance 1st Floor
Medical Media
CW424
G430
Ward 5E
Hoptel
Sleep Lab
EEG
Geriatrics Neurology
5th Floor
P
Elevator
Stairs
N
S
EW
P Ambulance Entrance 1st Floor
Emergency Entrance 1st Floor
Bed Tower Entrance
Ground Floor
Clinic Annex Women's Center
Entrances Ground Floor
Spinal Cord Injury Unit Entrance 2nd Floor
East Parking Lot
West Parking Lot
Smoking Shelter
Smoking Shelter
Administration Bldg Entrance
1st Floor
Staff Entrance 1st Floor
G536
| Camera Schedule |
| VA Supplemental Drawings and Schedule - Cameras Print |
File details come from the government source that posted it. Updated .