FA2823-21-Q-A009

Eglin TM Data Recorder Technical Requirement Document

8 Jan 2021

The 96th Range Group supports testing on many of Eglin Air Force Bases' telemetry sites by providing customized instrumentation to the sites. This requirement is for three (3) telemetry data recorders and components to upgrade existing instrumentation systems previously upgraded to meet new spectrum relocation requirements. This acquisition requires Safran brand name recorders to ensure compatibility with the existing range recording system.

CLIN Requirement Products Qty

Commercial Storage Module, Solid-

State Disk Safran Part No. SHS505-12200

0002 PCM Cards, Safran Part No. SHS511-2002 6

0003 Cables, Safran Part No. SDS105-0010 6

0004 GMDR-12 MDS,

Safran Part No. SHS505-32006-3 3

0005 Signal Module Blanking Plates Safran Part No. SHS120-0502/5/6 30

0006 Cables, Safran Part No. SDS105-0014 3

0007 GPS Receiver, Safran Part No. SHS505-2041 3

Delivery: The contractor shall deliver all items within one hundred twenty (120) days after receipt of order (ARO) to the address below.

96 Test Wing LMCA ATTN: Kenny Moore 505 North Florida Avenue Bldg 33 LMCA MHU Eglin AFB, FL 32542

Technical Specifications:

Physical:

Dimensions: 2RU / 3.5” High Weight: <50 lbs.

Temp (op): -10 to 55 deg C Humidity (op): 0% to 93%, non-condensing Temp (non-op): -20 to 70 deg C Power (VAC): 100-240 VAC Power (Hz): 48 to 62 Hz Power (Watts): <300 Watts

FA2823-21-Q-A0009

Cooling: Side or rear; top and bottom cover can be blocked

Standards:

IRIG 106 CH10 Compliant on all installed interfaces and devices

Record Media:

Disk Type: Solid-State Disk (Safran SHS505-12200, Qty 3) Disk Interface: SAS or SATA Disk bank Capacity: 2TB Data

Operator Control:

Terminal port / KVM Remote PC control via network using remote client or web interface Able to create, save, and reload recorder configuration files

Data Transfer:

Data Transfer to local USB and eSATA devices Transfer CH10 data files via GigE Ethernet Bit rate: 800 Mbit/s Ethernet: 100/1000 Mbs Ethernet bus, UDP broadcast, PTP (Precision Time Protocol; time code sync. IEEE 1588-2002/ IEEE 1588-2008), FTP server download function, remote control

Telemetry Interface Boards:

6 Digital PCM Channels per card (0-30Mbps) (Safran SHS511-2002, Qty 6) 6 Common TTL E to E / Playback outputs per card Output Impedance: 75 Ω 180 Mbs total card data rate Mating cables with single ended in/out BNC connectors (Safran SDS105-0010, Qty 6)

Physical Interface:

GMDR-12 MDS with 12 signal module slots, and two media receptacles- one Rugged Storage Module (RSM)/Rugged Raid Module (RRM), and one Commercial Media Receptacle (Safran 1A- SHS505-32006-3, Qty 3) BNC: All data, video, GPS antenna, and Timing RJ45: Ethernet connections Signal module blanking plates (Safran SHS120-0502/5/6, Qty 30) Power Connection: AC power Time, voice, synch connector: HD-D-Sub 26 pin female BNC mating cables for time, voice, and sync inputs (Safran SDS105-0014, Qty 3) Remote Connector: HD-D-Sub 26 pin female Front Panel Displays: 2 X >3” color active matrix

Timing:

Internal GPS receiver with IRIG A, B, G, 1 pps / 10 pps; GPS replay as RS232, and PTP outputs (Safran SHS505-2041, Qty 3) GPS time code, PTP (Precision Time Protocol; IEEE 1588-2002 (slave) / IEEE 1588-2008 (slave)) Precision Time Protocol; IEEE 1588-2002 time master version 1 / IEEE 1588-2008 time master version 2 Data recorded and time tagged with +-1 uS accuracy

FA2823-21-Q-A0009

Warranty:

One year parts and labor

Cybersecurity Requirements:

The recorder shall meet specific security controls as defined in the National Institute of Standards and Technology (NIST) Special Publication (SP) 800-53, Revision 4, Security and Privacy Controls for Federal Information Systems and Organizations. Security controls will be based on Point-to-Point system with Mission Assurance Category (MAC) III.