TCS #22, Rev. 8-29-24(Pull Boxes).pdf
PDF 921 KB Posted
- Attached to
- DOTD Pull Boxes(S45) State and local contract opportunity
- Solicitation number
- 3000025310
- Issued by
- Louisiana
About this file
This document is a Traffic Control Standard (TCS) Number 22 issued by the Louisiana Department of Transportation and Development (LA DOTD), specifically detailing specifications for precast concrete composite traffic signal wiring pull boxes and covers. The standard provides comprehensive requirements for pull boxes, including detailed dimensions, design specifications, and testing standards, with a revision date of August 29, 2024. The document outlines precise technical specifications for different box types (D, E, F, G, H, I, and J) with specific product ID numbers, dimensions, and cover configurations.
The technical standard references the American National Standards Institute/Society of Cable Telecommunications Engineers 77 (ANSI/SCTE 77) standards and requires Tier 15 compliance for design and testing. Each pull box must have specific features including a hollow base, embossed "TRAFFIC SIGNAL" logo, skid-resistant surface, pull slot(s), and be supplied with stainless steel or brass hardware (two sets of hex head bolts with washers). The specification mandates that technical documentation demonstrating compliance must be supplied with each shipment, and pull box measurements can vary within a range of no less than ½" smaller up to 2" larger than the specified dimensions.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Submission Instructions.pdf | ||
| 3000025310.pdf | ||
| Louisiana Preference(2019).pdf | ||
| U.S. Preference(2019).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LA DOTD TCS #22 Revised 08/29/24 Product ID No. – See Below Page 2 of 3
DESCRIPTION
The specification sets forth the minimum requirements for precast concrete composite traffic signal wiring pull boxes and covers. This specification refers to the American National Standards Institute/Society of Cable Telecommunications Engineers 77 (ANSI/SCTE 77) standards within.
REQUIREMENTS
See Figure 1, for pull box types and dimensions. Pull box measurements shall meet the requirements of the given sizes of no less than ½” smaller up to 2” larger. Pull box bases shall be hollow.
Covers shall be embossed with the logo “TRAFFIC SIGNAL” as indicated in each figure. Pull box covers shall cover the entire top opening of the pull box, have a skid resistant surface and a pull slot(s) as specified in the figure.
All boxes shall be provided with stainless steel or brass hardware that will secure the cover in place. Boxes and covers shall be supplied with two (2) sets of hex head bolts with washers.
DESIGN & TESTING
The design and testing of the boxes and covers shall conform to ANSI/SCTE 77-2023, Tier 15.
DOCUMENTATION
Technical data indicating compliance with this specification and test documents should be supplied with each shipment.
LA DOTD TCS #22 Revised 08/29/24 Product ID No. – See Below Page 3 of 3