Tank_Drawing.pdf

PDF 135 KB Posted

Attached to
Caustic Tank Replacement State and local contract opportunity
Solicitation number
26-P-00249
Issued by
Hillsborough County, Florida

About this file

This is a technical drawing document for a Snyder Industries tank model ET3 (ASM TK 8500VCT X 120) prepared for the City of Tampa Wastewater Department's caustic tank replacement procurement under solicitation number 26-P-00249. The procurement involves the supply and installation of a single 8,500-gallon vertical natural HDPE tank measuring 120 inches by 194 inches with a 1.9 specific gravity rating designed for 50% caustic applications. The tank must be delivered and installed at 2700 Maritime Boulevard, Tampa, Florida 33605, with delivery restricted to Monday through Friday between 7 a.m. and 3 p.m. Quote submissions were due April 17, 2026, and must remain valid for a minimum of 60 days from submission.

Pricing must be submitted on an FOB Destination basis with separate line item costs for the tank and installation labor, inclusive of all freight, handling, and shipping charges. The technical specifications include an 18-inch PE threaded/vented manway, two 4-inch and two 3-inch S.U.M.O. fittings, a 12-inch by 24-inch fitting, ladder lugs at 0 and 180 degrees, and eight tiedown/lifting lugs. All dimensions are in inches and subject to a 3% tolerance on rotational molded parts. All external piping must be independently supported, and only base fittings are to remain installed at shipment per Snyder Industries procedure. Vendors must consult Snyder's Guidelines for Use and Installation prior to delivery, available at http://www.snyderindustriestanks.com/Technical. The City identified two Small Local Business Enterprise (SLBE) certified vendors: Brian Carrier & Associates, Inc., based in Land O Lakes, Florida, and RZ Service Group LLC, headquartered in Tampa. All bidders must be licensed to do business in Florida, demonstrate E-Verify compliance, maintain proof of insurance, and comply with the City's non-discrimination, ethics, indemnification, and public records requirements. The City reserves the right to award by division, line item, or aggregate total.

View the file

Other files for this state and local contract opportunity

Other files attached to Caustic Tank Replacement, newest first.
File Type Posted
Caustic_Tank_Replacement.pdf PDF
Caustic_Tank_Replacement.pdf PDF
Directory_2026-04-07_(1)_Only_2_SLBE_vendors.xls XLS spreadsheet
Directory_2026-04-07_(1)_Only_2_SLBE_vendors.xls XLS spreadsheet
Tank_Drawing.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

*ALL EXTERNAL PIPING MUST BE INDEPENDENTLY SUPPORTED.

*ONLY BASE FITTINGS TO BE LEFT INSTALLED AT TIME OF SHIPMENT PER SII PROCEDURE.

*Consult Snyder's Guidelines for Use and Installation prior to delivery.

Available on-line at http://www.snyderindustriestanks.com/Technical

1.06 TYP.

120.0

179.6

94.0

FLANGE

LINE

9.0

62.0

FLANGE

LINE

8.3

192.5 194.2

18" PE THREADED/VENTED

MAWAY w/ 15" ACCESS

2-4" S.U.M.O.

FITTING LOCATION

(10" X 10") @ 0°

2-3" S.U.M.O.

FITTING LOCATION

(6.5" X 6.5") @ 90°

12" X 24" FITTING

FLAT @ 270°

LADDER LUGS

@ 0° AND 180°

15.0

15.0

14.4

15.7

1.5 TYP.

26.0

2.0 TYP.

6.5" X 6.5"

S.U.M.O. FLAT

0°

45°135°

180°

225°

270°

315°

10" X 10"

S.U.M.O. FLAT

12" X 24" FITTING

FLAT @ 270°

TIEDOWN/LIFTING

LUG 8 PLCS. 90° TYP.

90°

PART NO.

ET3

DRAWN BYDO NOT SCALE TITLE:

ENG. ID.

REVISION

ASM TK 8500VCT X 120

SHEET

© SNYDER INDUSTRIES, INC., 2019

ALL DIMENSIONS, DESIGNS, AND INFORMATION ON THIS PRINT MUST BE

CONSIDERED PROPRIETARY TO SNYDER INDUSTRIES, INC. AND MAY NOT

BE USED, COPIED, OR DISTRIBUTED WITHOUT WRITTEN PERMISSION OF AN

OFFICER (OR HIS AGENT) OF THE FIRM.

STATUS: Released

D0010477400000N

ALL DIMENSIONS ARE IN INCHES, NOMINAL, & SUBJECT TO CHANGE WITHOUT NOTICE.

ALL DIMENSIONS ON ROTATIONAL MOLDED PARTS ARE SUBJECT TO A 3% TOLERANCE.

(402) 467-5221 www.snydernet.com

B http://www.snyderindustriestanks.com/Technical/Guidelines-for-Use-Installation

Sheet1