Tank_Drawing.pdf
PDF 135 KB Posted
- Attached to
- Caustic Tank Replacement State and local contract opportunity
- Solicitation number
- 26-P-00249
- Issued by
- Hillsborough County, Florida
About this file
This is a technical drawing document for a Snyder Industries tank model ET3 (8500VCT X 120) required for the City of Tampa Wastewater Department's caustic tank replacement project at 2700 Maritime Blvd, Tampa, FL 33605. The drawing specifies a 120-inch diameter vertical cylindrical tank with detailed dimensional specifications, fitting locations, and installation requirements. Key specifications include an 18-inch PE threaded/vented manway with 15-inch access opening, two 4-inch S.U.M.O. fittings at the 0-degree position, two 3-inch S.U.M.O. fittings at the 90-degree position, a 12-inch by 24-inch fitting flat at 270 degrees, ladder lugs at 0 and 180 degrees, and eight tiedown/lifting lugs positioned at 90-degree intervals. All external piping must be independently supported, and only base fittings are to remain installed at shipment per Snyder Industries procedure.
The tank is designed and manufactured by Snyder Industries, Inc., with all dimensions nominal in inches and subject to a 3 percent tolerance on rotational molded parts. The technical drawing references Snyder's Guidelines for Use and Installation available at www.snyderindustriestanks.com/Technical, which must be consulted prior to delivery. The contract involves replacement of a caustic 50 percent tank per technical specifications to be delivered and installed at the designated Tampa wastewater facility location. All dimensions, designs, and information contained in the print are proprietary to Snyder Industries and require written permission from a company officer for any use, copying, or distribution.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Caustic_Tank_Replacement.pdf | ||
| Caustic_Tank_Replacement.pdf | ||
| Directory_2026-04-07_(1)_Only_2_SLBE_vendors.xls | XLS spreadsheet | |
| Directory_2026-04-07_(1)_Only_2_SLBE_vendors.xls | XLS spreadsheet | |
| Tank_Drawing.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
*ALL EXTERNAL PIPING MUST BE INDEPENDENTLY SUPPORTED.
*ONLY BASE FITTINGS TO BE LEFT INSTALLED AT TIME OF SHIPMENT PER SII PROCEDURE.
*Consult Snyder's Guidelines for Use and Installation prior to delivery.
Available on-line at http://www.snyderindustriestanks.com/Technical
1.06 TYP.
120.0
179.6
94.0
FLANGE
LINE
9.0
62.0
FLANGE
LINE
8.3
192.5 194.2
18" PE THREADED/VENTED
MAWAY w/ 15" ACCESS
2-4" S.U.M.O.
FITTING LOCATION
(10" X 10") @ 0°
2-3" S.U.M.O.
FITTING LOCATION
(6.5" X 6.5") @ 90°
12" X 24" FITTING
FLAT @ 270°
LADDER LUGS
@ 0° AND 180°
15.0
15.0
14.4
15.7
1.5 TYP.
26.0
2.0 TYP.
6.5" X 6.5"
S.U.M.O. FLAT
0°
45°135°
180°
225°
270°
315°
10" X 10"
S.U.M.O. FLAT
12" X 24" FITTING
FLAT @ 270°
TIEDOWN/LIFTING
LUG 8 PLCS. 90° TYP.
90°
PART NO.
ET3
DRAWN BYDO NOT SCALE TITLE:
ENG. ID.
REVISION
ASM TK 8500VCT X 120
SHEET
© SNYDER INDUSTRIES, INC., 2019
ALL DIMENSIONS, DESIGNS, AND INFORMATION ON THIS PRINT MUST BE
CONSIDERED PROPRIETARY TO SNYDER INDUSTRIES, INC. AND MAY NOT
BE USED, COPIED, OR DISTRIBUTED WITHOUT WRITTEN PERMISSION OF AN
OFFICER (OR HIS AGENT) OF THE FIRM.
STATUS: Released
D0010477400000N
ALL DIMENSIONS ARE IN INCHES, NOMINAL, & SUBJECT TO CHANGE WITHOUT NOTICE.
ALL DIMENSIONS ON ROTATIONAL MOLDED PARTS ARE SUBJECT TO A 3% TOLERANCE.
(402) 467-5221 www.snydernet.com
B http://www.snyderindustriestanks.com/Technical/Guidelines-for-Use-Installation
| Sheet1 |
| Drawing View1 |
| Drawing View2 |
File details come from the government source that posted it. Updated .