Attachment_One_(1)_DRAWINGs.pdf
PDF 3 MB Posted
- Attached to
- Change House Federal contract opportunity
- Solicitation number
- SPMYM2-15-Q-0265
About this file
Drawings Attachment One (1)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_0004_SPMYM2-15-Q-0265_(Change_House_Encl).doc | DOC document | |
| SPMYM2-15-Q-0265-0003.pdf | ||
| SPMYM2-15-Q-0265-0002.pdf | ||
| Attachment_Three_(3)_Revised_CDRLs.pdf | ||
| SPMYM2-15-Q-0265-0001.pdf | ||
| Attachment_Two_(2)_CDRLs.pdf | ||
| SPMYM2-15-Q-0265.pdf | ||
| SPMYM215Q0265_J A_2015-003_Redacted.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
PUGET SOUND NAVAL SHIPYARD
DRAWING NO.
TITLE
SCALE REV.
D W
G . N
O
T
IT
LE
R
E V
SIGNATURE DATE
CONCURRENCE
SIGNATURE DATE
APPROVAL
CODE
DISTRIBUTION STATEMENT: N/A
SIGNATURE DATE
A.D.C. REVIEW
CHANGE HOUSE ENCLOSURE
2370-1805
ORIG
O R
IG
G1 OF 53
ENGINEER
ENGINEER
(ELECTRICAL)
DRAWN
(ELECTRICAL)
BRANCH
SUPERVISOR
CHECKED
DRAWN
CHECKED
(ELECTRICAL)
/S/ DH DAILEY
/S/ JP TERRELL
11�19�14
11�19�14
/S/ RT WHEELER 11�19�14
/S/ DH DAILEY 11�19�14
/S/ JM BYRNES 11�19�14
/S/ MH SCHRODER 11�19�14
/S/ WL SPALINGER 11�19�14
/S/ JM BYRNES 11�19�14
/S/ SIGNATURE ON FILE
-1
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
GENERAL NOTES
1. GENERAL:
A. THIS DRAWING PROVIDES DETAILS AND REQUIREMENTS FOR THE CONSTRUCTION OF (1) CHANGE HOUSE ENCLOSURE.
B. THE CHANGE HOUSE SHALL BE CONSTRUCTED OFF-SIGHT AND SHIPPED TO PSNS & IMF BREMERTON, WA.
C. THE CONTRACTOR’S SURFACE(S) THAT IS USED FOR ERECTION AND ASSEMBLY SHALL BE FLAT WITHIN ±1/4” OVER THE ENTIRE
SURFACE AND ±1/4” OVER ANY 10’ SPAN OF THAT SURFACE.
D. THE CHANGE HOUSE IS DESIGNED TO BE LIFTED BY THE (4) LIFT POINTS AT THE ROOF. SEE SHEET G3 FOR LIFT SKETCHES.
E. THE CHANGE HOUSE SHALL BE COVERED WITH AN 8 mil (MIN) HEAT SHRINK CONSTRUCTION WRAP FOR SHIPMENT TO PSNS. THE
CONSTRUCTION WRAP SHALL PROVIDE COMPLETE WEATHER PROTECTION. DO NOT COVER LIFT POINTS WITH THE
CONSTRUCTION WRAP.
F. REFER TO PSNS & IMF DRAWING 2370-1806 FOR MATERIAL AND PRODUCT SPECIFICATIONS.
2. DESIGN: DESIGN LOADS ARE PER ASCE 7-10:
A. ROOF LIVE LOAD: 25 psf B. ROOF UPLIFT LOAD: 44 psf C. BASIC WIND SPEED: V=115 mph D. MAPPED SPECTRAL RESPONSE ACCELERATION (T=0.2 s): SS=1.57 E. MAPPED SPECTRAL RESPONSE ACCELERATION (T=1.0 s): S1=0.61
F. SEISMIC RESPONSE MODIFICATION FACTOR: R=3
3. DIMENSIONAL REQUIREMENTS:
A. DIMENSIONS UP TO 72” ARE SHOWN IN INCHES AND COMMON FRACTIONS. DIMENSIONS INCLUDING AND OVER 72” ARE SHOWN IN
FEET – INCHES AND COMMON FRACTIONS.
B. OPENINGS, WALLS, STRUCTURAL MEMBERS, ETC. ARE LOCATED RELATIVE TO THE OVERALL STRUCTURE BY THE GRID LINE
SYSTEM. COLUMNS AND BEAMS ARE CENTERED ON GRID LINES.
C. DIMENSIONS SHOWN IN PARENTHESES ARE PROVIDED FOR INFORMATION OR GUIDANCE. ACTUAL DIMENSIONS SHALL BE BASED
ON THE FIELD FIT OF THE PART BEING ASSEMBLED.
D. MANUFACTURING TOLERANCES SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE:
± .030” FOR ALL MACHINED SURFACES
± 1/8” FOR ALL DIMENSIONS FROM 0” TO 12”
± 1/4” FOR ALL DIMENSIONS GREATER THAN 12”
± 1º FOR ALL ANGLES
ABBREVIATIONS AND ACRONYMS
SHEET # SHEET NAME
G1 COVER, SHEET INDEX & GENERAL NOTES
G2 BUILDING ISOMETRICS
G3 LIFT SKETCH AND NOTES
A1 FLOOR PLAN - LEVEL 01; SYMBOL LEGEND
A2 FLOOR PLAN - LEVEL 02
A3 REFLECTED CEILING PLAN - LEVEL 01
A4 REFLECTED CEILING PLAN - LEVEL 02
A5 BUILDING EXTERIOR ELEVATIONS
A6 BUILDING SECTIONS
A7 EXTERIOR WALL SECTIONS
A8 INTERIOR ELEVATIONS
A9 STAIR ELEVATION & DETAILS
A10 PARTITION WALLS
A11 DOOR SCHEDULE; JAMB, SILL & HEAD DETAILS
A12 DOOR ROUGH FRAMING DETAILS
A13 FINISH PLAN - LEVEL 01
A14 FINISH PLAN - LEVEL 02
S1 STRUCTURAL NOTES & VIEW LEGEND
S2 FRAMING PLAN - BASE PLATE & LEVEL 01
S3 FRAMING PLAN - LEVELS 02 & ROOF
S4 STRUCTURAL ELEVATIONS
S5 BASE PLATE & CONNECTION DETAILS
S6 CONNECTION DETAILS - TYPICAL
S7 CONNECTION DETAILS - ROOF & COLD-FORMED JOISTS
S8 CONNECTION DETAILS - MOMENT FRAME
S9 CONNECTION DETAILS - MOMENT FRAME
S10 CONNECTION DETAILS - MOMENT FRAME
S11 CONNECTION DETAILS - BRACED FRAME
S12 CONNECTION DETAILS - BRACED FRAME
S13 DECK PLATE PLAN - LEVELS 01 & 02
S14 DECK PLATE PLAN - ROOF; DECK PLATE DETAILS
S15 RAISED DECK DETAILS
S16 GIRT ELEVATIONS
S17 GIRT DETAILS
M1 MECHANICAL NOTES & VIEW LEGEND
M2 VENTILATION PLAN - LEVEL 01
M3 VENTILATION PLAN - LEVEL 02
M4 VENTILATION ELEVATIONS AN DETAILS
E1 ELECTRICAL NOTES & VIEW LEGEND
E2 LIGHTING PLAN - LEVEL 01
E3 LIGHTING PLAN - LEVEL 02
E4 POWER PLAN - LEVEL 01
E5 POWER PLAN - LEVEL 02
E6 FIRE PLAN - LEVEL 01
E7 FIRE PLAN - LEVEL 02
E8 MISCELLANEOUS CONNECTIONS - LEVEL 01
E9 MISCELLANEOUS CONNECTIONS - LEVEL 02
E10 MAIN CABINET WIRING DIAGRAMS
E11 FIRE ALARM WIRING DIAGRAMS
E12 PA AND LIGHTING WIRING DIAGRAMS
E13 STENTOFON WIRING DIAGRAM
E14 SECURITY DOOR WIRING DIAGRAMS
E15 PANEL WIRING DIAGRAMS
SHEET INDEX
• AFF - ABOVE FINISHED FLOOR
• ADJ - ADJUSTABLE
• ASSY - ASSEMBLY
• B.O. - BOTTOM OF
• BF - BRACED FRAME
• CHE - CHANGE HOUSE ENCLOSURE
• CL - CENTERLINE
• COL - COLUMN
• CJP - COMPLETE JOINT PENETRATION
• CG - CORNER GUARD
• D - CONDENSATE LINE
• DTI - DIRECT TENSION INDICATOR
• DFT - DRY FILM THICKNESS
• DSW - DOMICILIARY SOLID WASTE
• DWV - DRAIN-WASTE-VENT
• EL. - ELEVATION
• ENCL - ENCLOSURE
• EOR - ENGINEER OF RECORD
• EQ - EQUAL
• ERV - ENERGY RECOVERY VENTILATOR
• EWA - EXISTING WALL ANCHOR
• GALV. - GALVANIZED
• GA. - GAUGE
• GR. - GRADE
• GWB - GYPSUM WALL BOARD
• HCP - HONEYCOMB WALL PANEL
• I.D. - INSIDE DIAMETER
• INSUL. - INSULATION
• NTS - NOT TO SCALE
• MFR - MANUFACTURER
• MSDS - MATERIAL SAFETY DATA SHEET
• MAX - MAXIMUM
• MIN - MINIMUM
• MTL - METAL
• MB - MOP BASIN
• O.C. - ON CENTER
• O.D. - OUTSIDE DIAMETER
• OPP - OPPOSITE
• PLCS - PLACES
• PL - PLATE
• PT - PRE-TENSIONED
• RL - REFRIGERANT LINE
• REQ’D - REQUIRED
• RR - RESTROOM
• SCH - SCHEDULE
• SAFB - SOUND ATTENUATION FIRE BLANKET
• SST - STAINLESS STEEL
• T&P - TEMPERATURE AND PRESSURE
• THK - THICK, THICKNESS
• T.O. - TOP OF
• TYP - TYPICAL
• UNO - UNLESS NOTED OTHERWISE
• WH - WATER HEATER
• WPS - WELD PROCEDURE SPECIFICATION
• W.P. - WORKING POINT
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
G2
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
G2
BUILDING ISOMETRIC 2
G2
BUILDING ISOMETRIC
G2
VIEW TITLE
NOTE
VIEW TITLE
NOTE
LOCATION
ELEVATION
VIEW NUMBER
SHEET NUMBER
VIEW IS ON
VIEW NUMBER
SHEET NUMBER VIEW
IS REFERENCED
SHEET NUMBER
VIEW IS ON
VIEW NUMBER
SHEET NUMBER
VIEW IS ON
VIEW NUMBER
SHEET NUMBER
VIEW IS ON
SHEET NUMBER
VIEW IS ON
VIEW REFERENCE
VIEW REFERENCE
ELEVATION VIEW
REFERENCE
PARTIAL SECTION
ELEVATION MARKER
VIEW SYMBOLS LEGEND
# VIEW TITLE
VIEW NUMBER
NOTE: MECHANICAL AND
ELECTRICAL COMPONENTS NOT
SHOWN IN ISOMETRIC VIEWS.
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
G3
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
G3
CHE LIFT SKETCH
20' SPREADER
ATTACH LABEL PLATE AT
APPROXIMATELY GRID 3,
5' ABOVE B.O. BASE PLATE
G3
PROOF TEST SKETCH FOR LIFT POINTS
COLUMN,
CONSTRAIN NEAR
CAP PLATE
CAP PLATE
PADEYE
LOAD TEST VALUE
67,500 LBS (MIN)
69,750 LBS (MAX)
35° 30°
G3
PROOF TEST SKETCH FOR LIFT POINTS
COLUMN,
CONSTRAIN NEAR
CAP PLATE
CAP PLATE
PADEYE
LOAD TEST VALUE
67,500 LBS (MIN)
69,750 LBS (MAX)
35° 30°
G3
G3
TEST PER
TEST PER
G3
LABEL PLATES FOR EACH LIFT POINT
QUANITY = 4
G3
ENCLOSURE LABEL PLATE
QUANITY =1
CHANGE HOUSE ENCLOSURE
DWG 2370-1805
WEIGHT: (ENTER OBSERVED WEIGHT)
MFR: (ENTER NAME OF GENERAL CONTRACTOR)
YEAR: (ENTER YEAR BUILT)
SPREADER REQUIRED FOR LIFTING
LIFT POINT
DWG 2370-1805
GPS CAPACITY: 45,000 LBS
TEST DATE: MM-DD-YYYY
PERIODIC TEST: NOT REQUIRED
SPREADER REQUIRED FOR LIFTING
LOAD TESTING AND NDT REQUIREMENTS
1. GENERAL NOTES:
A. ITEMS TO BE LOAD TESTED ARE FOUR (4) COLUMN PADEYES (SHOWN IN DETAIL 3 ON SHEET S7).
B. LOAD TESTING SHALL OCCUR IN SHOP ONCE CAP PLATES AND PADEYES HAVE BEEN WELDED TO THE FOUR (4) COLUMNS.
C. THE COLUMN, CAP PLATE AND PADEYE WELDMENTS ARE GENERICALLY REFERRED TO AS LIFT POINTS.
D. CONTRACTOR IS RESPONSIBLE FOR TEST FIXTURE DESIGN AND FINAL TEST PROCEDURE.
2. DOCUMENTATION:
A. AFTER COMPLETION OF LOAD TESTING, CONTRACTOR SHALL PROVIDE WRITTEN DOCUMENTATION THAT THE LOAD TEST AND NDT
REQUIREMENTS WERE SATISFACTORILY PERFORMED FOR EACH LIFT POINT.
B. ENSURE DOCUMENTATION CLEARLY SPECIFIES PERFORMANCE OF “PRE” AND “POST” LOAD VISUAL AND MT INSPECTIONS, METHOD USED (CLAUSE 6 OF AWS D1.1), ACCEPTANCE CRITERIA USED (CLAUSE 6, PART C OF AWS D1.1) AND ITEMS (PIECES AND
WELDS) THAT WERE INSPECTED AND TESTED.
C. DOCUMENTATION SHALL CLEARLY IDENTIFY THE LOCATION OF EACH LIFT POINT AFTER BUILDING ERECTION AND THE LOCATIONS
OF THEIR CORRESPONDING LABEL PLATES.
3. PRIOR TO AND FOLLOWING LOAD TEST, INSPECT EACH LIFT POINT AS FOLLOWS:
A. MATERIAL:
i. VISUALLY INSPECT THE LIFT POINTS FOR DEFORMATION OR OBVIOUS DAMAGE SUCH AS CRACKED, DISTORTED, CORRODED MATERIAL OR ANY DEFICIENCY THAT MAY AFFECT THE LIFTING CAPACITY OF THE PADEYE.
ii. MT THE ACCESSIBLE PORTIONS OF THE LIFT POINT PARENT MATERIAL PER AWS D1.1.
B. WELDS:
i. VISUALLY INSPECT THE WELDS SECURING EACH PADEYE AND CAP PLATE TO COLUMNS TO ENSURE THEY ARE PROPERLY SIZED AND INSTALLED IN ACCORDANCE WITH CLAUSE 6.9, PART C OF AWS D1.1 WITH THE FOLLOWING
EXCEPTIONS:
(a) NO UNDERSIZED WELDS ARE ALLOWED.
(b) NO POROSITY GREATER THAN 1/8 INCH IS ALLOWED.
(c) WELDS AND ADJACENT BASE METALS SHALL BE FREE OF LOCALIZED DISCONTINUITIES INCLUDING GOUGES, GRIND MARKS AND SURFACE ROUGHNESS WHICH EXCEEDS A DEPTH OF 1/32 INCH ON MATERIALS LESS THAN
1/2 INCH IN THICKNESS AND 1/16 INCH ON MATERIALS 1/2 INCH AND THICKER.
ii. MT THE ACCESSIBLE PORTIONS OF THE LIFT POINT ATTACHMENT WELDS PER AWS D1.1.
4. LOADS:
A. UPON COMPLETION OF CONSTRUCTION, MEASURE AND RECORD THE WEIGHT OF THE CHE. THIS SHALL BE THE WEIGHT ENTERED
ON THE ENCLOSURE LABEL PLATE.
B. THE ESTIMATED LIFTING WEIGHT OF THE FULLY-ASSEMBLED CHANGE HOUSE ENCLOSURE IS 100,000 LBS.
C. THE LOAD TEST VALUE FOR EACH LIFT POINT SHALL BE 150% (+5% / -0%) OF THE MAXIMUM DESIGN LIFT LOAD ANY OF THE LIFT
POINTS ARE ESTIMATED TO CARRY (UP TO 33,500 LBS EACH). THE LOAD TEST VALUE FOR EACH INDIVIDUAL LIFT POINT SHALL BE 67,500 (+2,250 / -0 LBS). THIS WILL GIVE A RATED CAPACITY OF 45,000 LBS FOR EACH LIFT POINT.
5. PERFORM LOAD TEST AS FOLLOWS:
A. LOAD TESTS SHALL BE PERFORMED ON INDIVIDUAL LIFT POINTS ONLY.
B. CONTRACTOR SHALL RESTRAIN THE COLUMN AND LOAD THE LIFT POINT IN SUCH A WAY TO REFLECT TRUE LOADING CONDITIONS.
C. LOAD TEST SHALL BE PERFORMED BY ATTACHING A 2 INCH SHACKLE TO THE PADEYE AND APPLYING THE PRESCRIBED LOAD TO
THE SHACKLE.
D. APPLY PROOF TEST LOAD, AS SHOWN IN DETAIL 2 (OR 3) ON SHEET G3, FOR TEN (10) MINUTES. INSPECT LIFT POINT ACCORDING
TO THE REQUIREMENTS OF NOTE 3. ABOVE.
E. REPEAT PROOF TEST FOR EACH LIFT POINT.
6. LABELING REQUIREMENTS:
A. THE LABEL PLATE SHALL BE CLEARLY VISIBLE AND FREE FROM OBSTRUCTIONS. ATTACH LABEL PLATE WITH DOUBLE-SIDED
BONDING TAPE. THE LABEL PLATE SHALL BE MADE FROM STAINLESS STEEL WITH 3/8 INCH TALL (MIN) LASER CUT LETTERING AND
CONTAIN THE FOLLOWING INFORMATION:
B. ATTACH A LABEL PLATE (VIEW 5/G3) ON THE EXTERIOR FACE OF THE EXTERIOR PANEL IN THE LOCATION SHOWN ON VIEW 1 OF
SHEET G3.
C. ATTACH A LABEL PLATE (VIEW 4/G3) ON THE ROOF PANEL, NEAR EACH OF THE FOUR LIFT POINTS, IN THE LOCATION SHOWN ON
VIEW 1 OF SHEET G3.
54321
A
B
C
'-0
'-0
'-0
40'-0"
10'-0" 10'-0" 10'-0" 10'-0"
ELECTRICAL
STAIRS
RAISED DECK, +3/4"
LOCKER ROOM
RAISED PLATFORM, +12"
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A1
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
UP
A1
FLOOR PLAN
LEVEL 01
A5
A5
A5
A5
A6
A6
A6
3/
4"
/2
8'
-9
/4
67 3/4" 40 1/2" 11 3/4"
9 1/4" 40 1/2" 14" 40 1/2"
15 3/4"
20'-0" 21 3/4" 6'-4 1/2" 21 3/4"
/4
/2
'-7
/2
/2
/4
49"
49"
/8
A9
SYMBOL DESCRIPTION
GRID LABEL
ROOM LABEL
PARTITION WALL LABEL
DOOR LABEL
SYMBOL LEGEND
ROOM NAME
A8
56"
54321
B
C
'-0
'-0
'-0
40'-0"
10'-0" 10'-0" 10'-0" 10'-0"
MESS AREA
RR B
RR A
CORRIDOR
STAIRS
CONFERENCE ROOM
HOUSE KEEPING
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A2
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
DOWN
A5
A5
A5
A5
A6
A6
A6
2 2
66" 44"
49"
A2
FLOOR PLAN
LEVEL 02
8' -9
/8
/2
A8
A8
A8
A83
A8
A8
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A3
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
54321
A
B
C
'-0
'-0
'-0
40'-0"
10'-0" 10'-0" 10'-0" 10'-0"
A3
REFLECTED CEILING PLAN
LEVEL 01
A5
A5
A5
A5
A6
A6
A6
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A4
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
54321
A
B
C
'-0
'-0
'-0
40'-0"
10'-0" 10'-0" 10'-0" 10'-0"
A5
A5
A5
A5
A6
A6
A6
A4
REFLECTED CEILING PLAN
LEVEL 02
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A5
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
1 2 3 4 5 C B A
CBA12345
67 4 3
2 1
CORNER TRIM PER
PANEL MFR, TYP
LIFT POINT
LIFT POINT
CORNER TRIM PER
PANEL MFR, TYP
EAVE TRIM PER
PANEL MFR, TYP
RAKE TRIM PER
PANEL MFR, TYP
RAKE TRIM PER
PANEL MFR, TYP
CORNER TRIM PER
PANEL MFR, TYP
RAKE TRIM PER
PANEL MFR
CORNER TRIM PER
PANEL MFR, TYP
EAVE TRIM PER
PANEL MFR, TYP
LIFT POINT
LIFT POINT
B.O. BASE PL
EL. 0' - 0"
T.O. DECK PL
EL. 0' - 9 3/8"
T.O. DECK PL
EL. 11' - 10 3/8"
T.O. RIDGE
EL. (24' - 10 1/2")
B.O. BASE PL
0' - 0"
T.O. DECK PL
EL. 0' - 9 3/8"
T.O. DECK PL
EL. 11' - 10 3/8"
B.O. BASE PL
EL. 0' - 0"
B.O. BASE PL
EL. 0' - 0"
T.O. DECK PL
EL. 0' - 9 3/8"
T.O. DECK PL
EL. 11' - 10 3/8"
T.O. DECK PL
EL. 11' - 10 3/8"
T.O. DECK PL
EL. 0' - 9 3/8"
A5
EXTERIOR ELEVATION
GRID A
A5
EXTERIOR ELEVATION
GRID C
A5
EXTERIOR ELEVATION
GRID 1
A5
EXTERIOR ELEVATION
GRID 5
2" INSULATED
METAL WALL PANEL
2" INSULATED
METAL WALL PANEL 2" INSULATED
METAL WALL PANEL
2" INSULATED
METAL WALL PANEL
2" INSULATED
METAL ROOF PANEL
DOORWAY WITH
BOLTING FLANGE,
SEE DETAIL 1
A12
DOORWAY WITHOUT
BOLTING FLANGE,
SEE DETAIL 4
A12
WATER SUPPLY AND
SANITARY WASTE STUB-OUTS,
SEE DETAIL
WALL EXHAUST HOODS
WALL EXHAUST/
INTAKE HOODS
WALL EXHAUST/
INTAKE HOODS
M1
24"
6"
M1
LIFT POINTS SHALL BE
CENTERED BETWEEN
STANDING SEAMS, TYP
INDUCTION
WALL LIGHTS
INDUCTION
WALL LIGHTS
INDUCTION
WALL LIGHTS
INDUCTION
WALL LIGHTS
NOTE: HVAC AND SOME ELECTRICAL
COMPONENTS NOT SHOWN IN
EXTERIOR ELEVATION VIEWS.
6"
NOTE: DO NOT
DRILL HOLES IN
FLANGE, THIS
DOOR ONLY
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A6
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A6
BUILDING SECTION 2 3
A6
BUILDING SECTION 3
A6
BUILDING SECTION 1
A B C
3 4
T.O. DECK PL
EL. 0' - 9 3/8"
T.O. DECK PL
11' - 10 3/8"
A7
A B C
ELECTRICAL
T.O. DECK PL
EL. 0' - 9 3/8"
T.O. DECK PL
11' - 10 3/8"
HOUSE
KEEPING
STAIRS
1 2 3 4 5
T.O. DECK PL
EL. 0' - 9 3/8"
T.O. DECK PL
11' - 10 3/8"
A7
CONFERENCE ROOM
LOCKER ROOM
CORRIDOR
STAIRS
HOUSE KEEPING CONFERENCE ROOM
LOCKER ROOM
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A7
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A7
TYP WALL SECTION
GRID C, GRID A SIMILAR
A7
TYP WALL SECTION
GRID 5, GRID 1 SIMILAR
GIRT, HSS3X3X1/8
2" INSULATED
METAL ROOF PANEL
2" INSULATED
METAL WALL PANEL
FASTENERS PER PANEL MFR
GIRT, HSS3X3X1/8
EAVE TRIM PER PANEL MFR
COLD-FORMED JOIST
RESILIENT FLOORING
ON DECK PLATE
C 5
METAL ROOF DECK FOAMED-IN-PLACE INSULATION
PARTITION
WALL PER SCH
ACCOUSTIC CEILING
ACCOUSTIC CEILING
PARTITION
WALL PER SCH
BEAM, W10X19
FOAMED-IN-PLACE
INSULATION, MIN 3" THK,
SEAL ENTIRE UNDERSIDE
OF CHE, PROVIDE
BACKING NOT SHOWN IF
NECESSARY
BASE TRIM AND DRIP EDGE
FLASHING PER PANEL MFR
FASTENERS PER PANEL MFR
RESILIENT FLOORING
ON DECK PLATE
BEAM, W10X19
GIRT, HSS3X3X1/8
2" INSULATED
METAL ROOF PANEL
2" INSULATED
METAL WALL PANEL
FASTENERS PER PANEL MFR
GIRT, HSS3X3X1/8
RAKE TRIM PER PANEL MFR
RESILIENT FLOORING
ON DECK PLATE
METAL ROOF DECK
FOAMED-IN-PLACE INSULATION
PARTITION
WALL PER SCH
ACCOUSTIC CEILING
ACCOUSTIC CEILING
PARTITION
WALL PER SCH
BEAM, W10X19
FOAMED-IN-PLACE
INSULATION, MIN 3" THK,
SEAL ENTIRE UNDERSIDE
OF CHE, PROVIDE
BACKING NOT SHOWN IF
NECESSARY
BASE TRIM AND DRIP EDGE
FLASHING PER PANEL MFR
FASTENERS PER PANEL MFR
RESILIENT FLOORING
ON DECK PLATE
BEAM, W10X19
BEAM, W8X10
INSULATION BACKING,
16 GA. SST, 1 1/2" LAPS
BEAM, W8X35
INSULATION BACKING,
16 GA. SST, 1 1/2" LAPS
A7
TYP WALL CORNER
IN WAY OF LEVEL 01
A7
TYP WALL CORNER
IN WAY OF LEVEL 02
INSIDE CORNER TRIM,
SEE DETAIL 5
S17
2" INSULATED
WALL PANEL
2" INSULATED
WALL PANEL
COLUMN, W10X33
GWB
METAL STUD
FOAMED-IN-PLACE
INSULATION
FASTENERS PER PANEL MFR
OUTSIDE CORNER
TRIM PER PANEL MFR
INSIDE CORNER TRIM,
SEE DETAIL 5
S17
2" INSULATED
WALL PANEL
2" INSULATED
WALL PANEL
COLUMN, W10X33
METAL STUD
FOAMED-IN-PLACE
INSULATION
FASTENERS PER PANEL MFR
OUTSIDE CORNER
TRIM PER PANEL MFR
INSIDE CORNER BATTEN
ASSEMBLY, SEE DETAIL
CLEANROOM WALL PANEL
A12
8"
TYP
4 1/2"
TYP
8"
TYP
4 7/8"
TYP
1-12
FIRE BLOCK, FOAM-IN-PLACE INSULATION,
FULLY SEAL AROUND BUILDING
PERIMETER; MIN THICKNESS OF 2"
1-12
FIRE BLOCK BACKING,
BENT 16 GA. STEEL GALV.
FIRE BLOCK BACKING,
BENT 16 GA. STEEL GALV.
FIRE BLOCK, FOAM-IN-PLACE
INSULATION, FULLY SEAL
AROUND BUILDING PERIMETER
1-12
1-12
16 GA. SHEET AT
EVERY STUD, TYP
TYP
TYP4
TYP 4
TYP4
TYP 4
METAL STUD
TYP 4
METAL STUD
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A8
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
STAIRSCORRIDOR
(2) CGCG
A8
INTERIOR ELEVATION
MESS AREA
A8
INTERIOR ELEVATION
RESTROOM
34"
20"
24"
A8
INTERIOR ELEVATION
HOUSEKEEPING 1
A8
INTERIOR ELEVATION
HOUSEKEEPING 2
RESILIENT WALL BASE
48"
PIPE SLEEVE FOR
DISTRIBUTION PIPING,
LOCATE TO SUIT
BACK SPLASH, 22 GA. SST 304
SHEET, HEMM TOP EDGE, #4
BRUSH FINISH, GLUE TO
SUBSTRATE, TYP
SURFACE MOUNT WATER
SUPPLY MANIFOLDS, WATER
HEATER AND VALVES ON
STAINLESS SHEET
PIPE SLEEVE FOR
MAIN WATER SUPPLY,
LOCATE TO SUIT
BACK SPLASH,
22 GA. SST 304
SHEET, HEMM
TOP EDGE, #4
BRUSH FINISH,
GLUE TO
SUBSTRATE,
TYP
A8
INTERIOR ELEVATION
HOUSEKEEPING 3
48"
BACK SPLASH, 22 GA. SST 304
SHEET, HEMM TOP EDGE, #4
BRUSH FINISH, GLUE TO
SUBSTRATE, TYP
48"
SERVICE FAUCET
25" 21"
10"MOP BASIN
36"
SERVICE FAUCET,
CENTER OVER
MOP BASIN
RESILIENT WALL BASE, TYP
MOP BASIN
27"
5"
A8
INTERIOR ELEVATION
BASE OF STAIRS
PLUMBING ACCESS
DOOR, 12" x 12" SST, ALLEN HEAD CAM
36"
18"
30" 3"
30"
3" FILLER, TO MATCH
CABINETRY FINISH
18"
SURFACE
MOUNTED
MIRROR
PEDESTAL SINK
TOILET
3"30"18"
PLUMBING
ACCESS DOOR,
12" x 12" SST, ALLEN HEAD CAM, TO SERVICE
FAUCET STOP
VALVES
MAXIMUM OCCUPANCY
IS 49 OCCUPANTS
66"
POST SIGN READING
"MAXIMUM OCCUPANCY
IS 49 OCCUPANTS" IN
1/2" TALL LETTERS
12" x 12" ELECTRICAL ENCL
RECESSED IN WALL, FOR
DOOR ELECTRIC STRIKE3"
3"
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A9
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A9
STAIR ELEVATION
'-1
R
IS
E
R S
T.O. DECK PL
EL. 0' - 9 3/8"
T.O. DECK PL
EL. 11' - 10 3/8"
DECK PL
(2) HANDRAILS
7" R
IS
E
11"
RUN
T .O
. R A
IL
1"
(2) STRINGERS,
C12X20.7
1 1/2" MIN, 2 1/2" MAX
BACKING, 3 5/8" MTL STUD
INTERIOR WALL
PANEL PER PLAN
SELF-TAPPING
SCREWS, SST
HANDRAIL BRACKET, SST
HANDRAIL, PIPE 1 1/2" SCH 40 SST
A9
TYP HANDRAIL/BRACKET
FILL VOID WITH
FOAM-IN-PLACE
INSULATION, TYP
A9
STAIR NOSING DETAIL
A9
STAIR BASE DETAIL
A9
STAIR TOP DETAIL
NOTE: INSUL. NOT SHOWN FOR CLARITY
STAIR TREADS,
DIAMOND PL 1/8" THK,
44" TREAD WIDTH
BEAM,
C10X15
RETURN HANDRAIL
ENDS TO WALL,
CAP AND SEAL
WELD PER DETAIL
,TYP
BATT INSUL., 3" SAFB
1/4" HCP OVER (3) 1/2" GWB,
ATTACH TO ANGLE W/
SELF-TAPPING SCREWS
T .O
. R A
IL
2"
FILL VOID WITH
FOAM-IN-PLACE
INSULATION, TYP
STINGER CAP, PL 1/8"
1/8 1/8
L3X3X3/8 x 6", SEE TYP
SHEAR CONNECTION
FOR DETAILS
1/
2"
A9
STAIR ATTACHMENT DETAIL
IN WAY OF STRINGER TOP
3 SIDES3/16
T.O. DECK PL
A9
STAIR ATTACHMENT DETAIL
IN WAY OF STRINGER BOTTOM
TERMINATE FLOORING AT
LOWER RISER AND STRINGERS
(2) 3/4"O BOLTS
STRINGER
BEAM, C10X15
LOWER RISER
STRINGER
3 SIDES3/16
BEAM, W8X10
1 1/2"
L3X3X3/8 x 6", SEE TYP
SHEAR CONNECTION
FOR DETAILS
PL 1/8"
BEAM CL
3"
BOLT RISER TO
STRINGER PER MFR
STRINGER CAP, PL 1/4"
UPPER STAIR
TREAD/RISER
STRINGER STRINGER
STRINGER
BOLT TREADS TO
STRINGER PER MFR, TYP
INTERMEDIATE
TREAD/RISER
A9
A9
A9
A9
TREAD
1"
THIS SIDE ONLY
CONTINUOUS SEALANT
GWB-TO-STRINGER, TYP
STRINGER
CONTINUOUS SEALANT
HCP-TO-HCP, TYP
MTL STUD
MTL STUD
11"
FURRING
PER WALL
SECTION
DECK PL
REFER TO WALL
SECTIONS FOR
DETAILS NOT SHOWN
A9
STAIR SECTION
S17
HANDRAIL BRACKET,
4' O.C. MAX SPACING
12"
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A10
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
MTL STUD
A10
SECTION
WALL TYPE '1'
A10
SECTION
WALL TYPE '2'
A10
SECTION
WALL TYPE '3'
A10
SECTION
WALL TYPE '4'
A10
SECTION
WALL TYPE '5'
A10
SECTION
WALL TYPE '6'
A10
SECTION
WALL TYPE '7'
9'-0"
ACOUSTIC
CEILING
3"
HCP 1/4"
(ONE SIDE)
DECK PLATE
RESILIENT
FLOOR & BASE
MTL STUD
ACOUSTIC
CEILING
GWB 1/2"
(ONE SIDE)
DECK PLATE
RESILIENT
FLOOR & BASE
9'-0"
MTL STUD
ACOUSTIC
CEILING
HCP 1/4"
(EACH SIDE)
DECK PLATE
RESILIENT
FLOOR & BASE,
BOTH SIDES
9'-0" 9'-0"9'-0"
3"
CHANNEL STUDS
(TOP & BOTTOM)
ATTACH TO
STRUCTURE
MTL STUD
ACOUSTIC
CEILING
(3) 1/2" GWB
FIRE RATED
DECK PLATE
RESILIENT
FLOOR & BASE,
BOTH SIDES
WIDTHWIDTH WIDTH WIDTHWIDTH
CHANNEL STUDS
(TOP & BOTTOM)
ATTACH TO
STRUCTURE
CHANNEL STUDS
(TOP & BOTTOM)
ATTACH TO
STRUCTURE
MTL STUD
ACOUSTIC
CEILING
GWB 1/2"
(EACH SIDE)
DECK PLATE
RESILIENT
FLOOR & BASE,
BOTH SIDES
CHANNEL STUDS
(TOP & BOTTOM)
ATTACH TO
STRUCTURE
ACOUSTIC PAD
(LOCKER SIDE)
HCP 1/4"
(LOCKER SIDE)
BATT INSUL.
1 2 3 64 5
MTL STUD
ACOUSTIC
CEILING
(3) 1/2" GWB
FIRE RATED
RESILIENT
FLOOR & BASE
ACOUSTIC PAD
GWB 1/2"
CHANNEL STUDS
(TOP & BOTTOM)
BATT INSUL.
9'-0"
3"
MTL STUD
DECK PLATE
RESILIENT
FLOOR & BASE,
BOTH SIDES
ACOUSTIC PAD
(LOCKER SIDE)
BATT INSUL.
CHANNEL STUDS (TOP
& BOTTOM) ATTACH
TO STRUCTURE
CHANNEL STUDS (TOP
& BOTTOM) ATTACH
TO STRUCTURE
GWB (FROM
ABOVE)
VARIES
1"
HCP 1/4"
(EACH SIDE)
STAIR
STRINGER
1 1/2" FURRING
CHANNEL/HAT
@ 24" O.C.
3"
9'-0"
DECK PLATE
3" 3" 4 1/8" 4 5/8" 5 5/8" 5 3/8" 5 5/8"
DEPTH 2 1/2" DEPTH 2 1/2" DEPTH 3 5/8" DEPTH 3 5/8" DEPTH 3 5/8" DEPTH 3 5/8" DEPTH 3 5/8"
GAUGE 20 GAUGE 20 GAUGE 20 GAUGE 20 GAUGE 20 GAUGE 20 GAUGE 20
SPACING 24" SPACING 24" SPACING 24" SPACING 24" SPACING 24" SPACING 24" SPACING 24"
HEIGHT to structure HEIGHT 9' - 3" HEIGHT 9' HEIGHT 9' HEIGHT 9' HEIGHT to structure HEIGHT see w all section
TYPE HCP TYPE GWB TYPE HCP TYPE GWB TYPE GWB TYPE GWB & HCP TYPE HCP
THICKNESS 1/4" THICKNESS 1/2" THICKNESS 1/4" THICKNESS 1/2" THICKNESS
see w all section
THICKNESS
see w all section
THICKNESS 1/4"
HEIGHT
3" above ceiling
HEIGHT 9' HEIGHT 9' HEIGHT 9' HEIGHT
see w all section
HEIGHT
see w all section
HEIGHT
see w all section
BATT
INSULATION
no
BATT
INSULATION
no
BATT
INSULATION
no
BATT
INSULATION
no
BATT
INSULATION
3" SAFB
BATT
INSULATION
3" SAFB
BATT
INSULATION
3" SAFB
ACOUSTIC PAD no ACOUSTIC PAD no ACOUSTIC PAD no ACOUSTIC PAD yes ACOUSTIC PAD yes ACOUSTIC PAD yes ACOUSTIC PAD yes
ACOUSTIC
SEALANT
no
ACOUSTIC
SEALANT
no
ACOUSTIC
SEALANT
no
ACOUSTIC
SEALANT
yes
ACOUSTIC
SEALANT
yes
ACOUSTIC
SEALANT
yes
ACOUSTIC
SEALANT
yes
WALL TYPE '2' WALL TYPE '7'
A C
O U
S T
IC
S
A C
O U
S T
IC
S
W A
LL
C
O V
E R
IN
G
W A
LL
C
O V
E R
IN
G
A C
O U
S T
IC
S
W A
LL
C
O V
E R
IN
G
A C
O U
S T
IC
S
A C
O U
S T
IC
S
M E
T A
L S
T U
D
M E
T A
L S
T U
D
TABLE A10: PARTITION WALL SCHEDULE
WALL TYPE '6'WALL TYPE '3'WALL TYPE '1' WALL TYPE '4' WALL TYPE '5'
M E
T A
L S
T U
D
WIDTH
A C
O U
S T
IC
S
M E
T A
L S
T U
D
W A
LL
C
O V
E R
IN
G
A C
O U
S T
IC
S
M E
T A
L S
T U
D
M E
T A
L S
T U
D W
A
LL
C O
V E
R
IN
G
W A
LL
C
O V
E R
IN
G
W A
LL
C
O V
E R
IN
G
M E
T A
L S
T U
D
WIDTH WIDTH WIDTH WIDTH WIDTH WIDTH
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A11
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
2"
5 3/4"
JAMB FRAME
ANCHORS
EXTERIOR WALL PANEL
INTERIOR WALL PER PLAN
1"
5 3/4"
1"
5 3/4"
EXTERIOR WALL PANEL
INTERIOR WALL PER PLAN
4"
1"
5 3/4"8"
4 7/8"
OR
4 1/2"
8"
4 7/8"
OR
4 1/2"
CG
CAULK AROUND
BOTH SIDES, TYP
WALL TYPE PER PLAN
JAMB FRAME
ANCHORS
WALL TYPE
PER PLAN
1" 5 3/4"
1/4"
TYP
2"
8"
BEAM PER PLAN
GIRT, HSS3X3X1/8
CAULK AROUND
BOTH SIDES, TYP3"
INTERIOR WALL PER PANEL
HEAD PLATE,
BENT PL 1/8"
EXTERIOR
WALL PANEL
3"
RESILIENT FLOORING
ON DECK PL1/2"
1/4"
TYP
2"
5 1/2"
RESILIENT FLOORING
ON DECK PL
THRESHOLD
PER SCHEDULE
11"
4"
1/2"
MAX
GIRT, HSS3X3X1/8
4"
INTERIOR WALL
PER PANELEXTERIOR
WALL PANEL
5 3/4"
CG CG
1"
DRIP EDGE AT HEAD,
BASE TRIM AND
FLASHING PER PANEL
MFR, TYP
1 SILL 4 SILL
2 HEAD 5 HEAD
3 JAMB 6 JAMB 8 JAMB
7 HEAD
CG
SILL PLATE,
BENT PL 1/4"
PL 1/8" x 3", FULL HEADER
LENGTH
MTL STUD
5 1/2"
THRESHOLD
PER SCHEDULE
2"
DOOR WIDTH
2"
D O
O R
H E
IG
H
T 2"
TYPE 'F' TYPE 'G' TYPE 'F'HOLLOW
METAL FRAME
JAMB PLATE,
BENT PL 1/8"
JAMB PLATE,
BENT PL 1/4"
NOTE: SILL #4, JAMB #6 AND HEAD #5
MAKE UP DOORWAYS WITH AN OUTSIDE
BOLTING FLANGE. SEE DETAIL 1
A12
CAULK AROUND
BOTH SIDES, TYP
HEAD PLATE,
BENT PL 1/4"
1"
FOAMED-IN-PLACE
INSULATION
FOAMED-IN-PLACE
INSULATION
5 3/4"
DRIP EDGE AT
HEAD, BASE
TRIM AND
FLASHING
PER PANEL
MFR, TYP
1/8
PL 1/8" x 3", FULL JAMB
LENGTH
1/8
NOTE: SILL #1, JAMB #3 AND HEAD #2
MAKE UP DOORWAYS WITHOUT AN
OUTSIDE BOLTING FLANGE. SEE DETAIL 4
A12
WIDTH HEIGHT
1 1 LOCKER RM OUTSIDE 16 5-3/4" EWA 16 F 3' - 0" 6' - 8" HW-1 2 3 1
2 1 LOCKER RM OUTSIDE 16 5-3/4" EWA 16 F 3' - 0" 6' - 8" HW-2 5 6 4
3 1 LOCKER RM OUTSIDE 16 5-3/4" EWA 16 G 3' - 0" 6' - 8" HW-3 5 6 4 90 min RATED
4 1 LOCKER RM OUTSIDE 16 5-3/4" EWA 16 G 3' - 0" 6' - 8" HW-3 5 6 4 90 min RATED
5 1 LOCKER RM OUTSIDE 16 5-3/4" EWA 16 F 6' - 0" 8' - 0" HW-4 5 6 4 NO THRESHOLD
6 1 LOCKER RM OUTSIDE 16 5-3/4" EWA 16 F 3' - 0" 6' - 8" HW-1 2 3 1
7 1 STAIRS OUTSIDE 16 5-3/4" EWA 16 F 3' - 0" 6' - 8" HW-5 2 3 1
8 2 BATH A CORRIDOR 16 5-3/4" SSA 18 F 2' - 8" 6' - 8" HW-7 7 8 N/A
9 2 BATH B CORRIDOR 16 5-3/4" SSA 18 F 2' - 8" 6' - 8" HW-7 7 8 N/A
10 2 HOUSE KEEPING CORRIDOR 16 5-3/4" SSA 18 F 2' - 8" 6' - 8" HW-7 7 8 N/A
11 2 CONF RM CORRIDOR 16 5-3/4" SSA 18 F 2' - 8" 6' - 8" HW-6 7 8 N/A
12 2 CONF RM CORRIDOR 16 5-3/4" SSA 18 F 2' - 8" 6' - 8" HW-6 7 8 N/A
13 2 CONF RM OUTSIDE 16 5-3/4" EWA 16 F 3' - 0" 6' - 8" HW-1 5 6 4
H'WARE
SETFROM TYPE
GAUGE
(MIN)LEVEL SILL
ANCHOR
TYPE
GAUGE
(MIN) JAMBTO
DETAIL
OPENING
DEPTH
DOOR
REMARKS
TABLE A11: DOOR SCHEDULE
DOOR
LOCATION FRAME
HEAD
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A12
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
11 11/16" 23 1/2"
12"
24"
36"
48"
60"
6'-0"
7'-0"
11 11/16"
1 1/2" TYP
CL
44" (6'-8")
7'-0" (8'-4")
1 1/2"
TYP
1 1/2"
TYP
A12
TYP DOORWAY WITH BOLTING FLANGE
NOTE: DOOR #5 DIMENSIONS IN PARENTHESES
TYP 3/16
3/16
TYP 3/16
TYP
1/4" TYP
A12
DOORWAY FLANGE SECTION
NOTE: DECK PL SHOWN
HEADER
PLATE,
1/4" PL
4"
4"
O 5/8" THRU
(22) PLACES
4" 4"
3/16 TYP3/16
JAMB PLATE,
1/4" PL,
EACH SIDE
A12
SILL PLATE, 1/4" PL
JAMB PLATE
SILL PLATE
A12
DOORWAY FLANGE SECTION
3/16
A12
3/16 3/16
JAMB PLATE
3/16TYP 3/16
20 1/2" TYP
(38 1/2")
5 1/4"
TYP
5 1/2" TYP
VARIES
2 1/2" TYP
HEADER PLATE
HEADER PLATE
JAMB PLATE
DECK PL
A12
TYP DOORWAY WITHOUT BOLTING FLANGE
DECK PL
6'-10 1/4"
CLEAR
3" 40 1/2"
CLEAR
3"
1 3/4"
1 3/4"
TYP 1/8 TYP1/8
1/8 TYP1/8
JAMB PLATE,
1/8" PL,
EACH SIDE
HEADER PLATE, 1/8" PL5
A12
VARIES
2 1/2" TYP2 7/8"
TYP
A12
DOORWAY SECTION
3"
HEADER PLATE
CL
20 3/8" TYP
HEADER PLATE
JAMB PLATE
CLEANROOM
WALL PANEL
CLEANROOM WALL PANEL
COLUMN, W10X33
METAL STUD, FLANGE
WIDTH MIN 2 1/2" FOR
BATTENS, TYP
METAL STUD
SCREW, SST, PAN HEAD,
SELF-DRILLING, SIZE TO SUIT
BATTEN MOUNTING HOLES, TYP
ENCLOSURE CAP, TYP
GASKET, 1/16" x 1/4", TYP
BATTEN, 1 3/4"
SHALLOW, TYP 2 PLCS
A12
TYP INSIDE CORNER BATTEN ASSY
A12
TYP VERTICAL BATTEN ASSY
BATTEN, 1 3/4"
SHALLOW
CLEANROOM WALL PANEL
CLEANROOM WALL PANEL
METAL STUD, FLANGE
WIDTH MIN 2 1/2" FOR
BATTENS, TYP
SCREW, SST, PAN HEAD,
SELF-DRILLING, SIZE TO SUIT
BATTEN MOUNTING HOLES, TYP
ENCLOSURE CAP
GASKET, 1/16" x 1/4", TYP 2 PLCS
SEALANT, TYP
SEALANT, TYP
TYP 4
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A13
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
54321
A
B
C
'-0
'-0
'-0
40'-0"
10'-0" 10'-0" 10'-0" 10'-0"
ELECTRICAL
STAIRS
RAISED DECK, +3/4"
LOCKER ROOM
RAISED PLATFORM, +12"
A13
FINISH PLAN
LEVEL 01
RESILIENT FLOORING
RESILIENT FLOORING
RESILIENT FLOORING
RESILIENT
FLOORING
STAIR TREADS,
RAISED DIAMOND
PATTERN, GREY
EPOXY PAINT
A13
TYP RAISED PLATFORM FINISH DETAIL
RESILIENT FLOORING
RESILIENT FLOORING
RESILIENT WALL BASE
DECK PL
DECK PL
CORNER GUARD,
MITER CORNERS
A13
A13
CHANNEL,
C12X20.7
RESILIENT FLOORING
CG, 16 GA SST, 2"
WINGS, FULL WALL
HEIGHT, ATTACH WITH
COUNTERSUNK SST
SCREWS, TYP ALL
EXTERIOR CORNERS
NO CG, USE
BATTEN
ASSEMBLY
NO CG, USE
BATTEN
ASSEMBLY
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
A14
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
54321
A
B
C
'-0
'-0
'-0
40'-0"
10'-0" 10'-0" 10'-0" 10'-0"
MESS AREA
RR B
RR A
CORRIDOR
STAIRS
CONFERENCE ROOM
HOUSE KEEPING
A14
FINISH PLAN
LEVEL 02
RESILIENT FLOORING
RESILIENT FLOORING
RESILIENT
FLOORING
RESILIENT
FLOORING
RESILIENT
FLOORING
25"
CG, TYP
LEVEL 02
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S1
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
INDICATES GRID LINE
COLUMN
BASE PLATE PER DETAIL
INDICATES BEAM-TO-COLUMN SHEAR CONNECTION
INDICATES BEAM-TO-COLUMN MOMENT CONNECTION
L
LINES LOCATING C-SHAPES ARE TO FACE OF WEB
L
LINES LOCATING W-SHAPES ARE TO C
LINES LOCATING COLD-FORMED JOISTS ARE TO C
INDICATES COLD-FORMED JOISTS FRAMING INTO SIDE OF BEAM
W
X
BEAM SHAPE DESIGNATION
INDICATES BEAM FRAMING INTO SIDE OF BEAM
W
X33COLUMN SHAPE DESIGNATION
STRUCTURAL SYMBOL LEGEND
S1
STRUCTURAL ISOMETRIC VIEW
STRUCTURAL NOTES
1. FABRICATION REQUIREMENTS:
A. UNLESS OTHERWISE SPECIFIED, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC “CODE OF STANDARD
PRACTICE FOR STEEL BUILDINGS AND BRIDGES”, LATEST EDITION.
B. TYPICAL CONSTRUCTION DETAILS AND WELDS ARE TO BE USED FOR SIMILAR ITEMS.
C. BREAK ALL SHARP EDGES TO A 1/32” CHAMFER (MIN) AND REMOVE ALL WELD SPLATTER FROM EXPOSED SURFACES.
D. CORNERS MAY BE SNIPED TO CLEAR FILLETS OF PREVIOUSLY DEPOSITED WELDS AND EXISTING MATERIAL RADIUS. CLOSE THESE
CHAMFERS BY WELDING WHERE POSSIBLE.
E. CLIP ANGLES, SHEAR TABS AND SHEAR SPLICE PLATES MAY BE LOCATED ON EITHER SIDES OF BEAM. WHEN TWO OPPOSING
EXTENDED SHEAR TABS FRAME INTO THE SAME COLUMN, THEY MUST BE LOCATED ON THE SAME SIDE OF THEIR CONNECTING
BEAMS.
F. WELDING:
i. WELDING SHALL COMPLY WITH WELDING PROCEDURE AND PERFORMANCE REQUIREMENTS OF AWS D1.1.
ii. WELD SYMBOLS SHOWN ARE IN ACCORDANCE WITH AWS A2.4.
iii. VISUALLY INSPECT ALL WELDS IN ACCORDANCE WITH AWS D1.1 WITH THE FOLLOWING EXCEPTION: NO UNDERSIZED
WELDS ARE ALLOWED AND NO POROSITY GREATER THAN 1/8” IS ALLOWED.
iv. WELDS SHALL BE SEQUENCED TO MINIMIZE DISTORTION. WHERE DISTORTION DOES OCCUR, STRAIGHTENING PER AWS
D1.1 SHALL BE PERFORMED TO ACHIEVE TOLERANCES OF THE DRAWING.
v. WELDS MAY BE GROUND FLAT FOR FIT-UP OF OTHER PIECES.
2. STRUCTURAL BOLTED JOINTS:
A. TWO OPTIONS ARE AVAILABLE FOR STRUCTURAL BOLTED ASSEMBLIES:
i. OPTION 1: BOLT ASSEMBLY SHALL CONTAIN (1) ASTM A325 BOLT, (1) ASTM A563 NUT, (1) ASTM F436 HARDENED WASHER
AND (1) ASTM F959 DTI WASHER.
ii. OPTION 2: BOLT ASSEMBLY SHALL BE “TWIST OFF” TYPE IN ACCORDANCE WITH ASTM F1852.
B. BOLT SIZES ARE SPECIFIED IN THIS DRAWING. BOLT LENGTHS MAY BE BASED ON THE BOLT THREADS INCLUDED IN THE SHEAR
PLANE (TYPE “N” CONNECTIONS).
C. ENSURE JOINT SURFACES THAT WILL BECOME INACCESSIBLE UPON ASSEMBLY OF THE BOLTED JOINT ARE PAINTED PRIOR TO
ASSEMBLY OF THE JOINT.
D. BOLT ASSEMBLIES CAN BE ORIENTED AS SHOWN IN THIS DRAWING OR MAY BE TURNED 180º FROM SHOWN TO FACILITATE
ASSEMBLY OF THE BOLTED JOINT.
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S2
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A B C
A B C
S2
FRAMING PLAN
BASE PLATE
S2
FRAMING PLAN
LEVEL 01
W
X33
W
X33
W
X33
W
X33
W
X33
W
X33
W
X33
W
X33
W
X33
W
X33
W
X33
W
X33
W8X35
W8X35
W8X35
W8X35
W8X35
W 8X
W
8X
W 8X
W
8X
W 8X
W
8X
W 8X
W
8X
'-0
'-0
'-0
'-0
13'-0" 13'-0"
'-0
'-0
'-0
'-0
13'-0" 13'-0"
S4
S4
S4
S4
S4
S4
S4
S4
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
BP1
BP1
BP1
BP1
BP1
BP1
BP1
BP1
BP1
BP1
BP2
BP3
BP3
BP3
BP2
W8X35
W8X35
14"
TYP
10'-8"8 @ 16" = TYP 10'-8"8 @ 16" = TYP 14"
TYP
W 8X
52 1/2"
S5
NOTE: FRAMING
FOR RAISED
PLATFORM NOT
SHOWN.
NOTE: COLD-FORMED JOISTS ARE NOT
LABELED IN PLAN VIEWS. REFER TO
STRUCTURAL STEEL LEGEND ON SHEET S1
FOR THEIR LINE WEIGHT. JOISTS ARE 8"
DEEP C-SHAPES WITH LIPS 2 1/2" FLANGE
WIDTH AND 15 GAUGE THICK. MATERIAL IS
33 ksi YIELD STRENGTH AND GALV. G90.
NOTE: SPACING OF COLD-FORMED JOISTS
IS 16" O.C. UNLESS OTHERWISE SPECIFIED.
BLOCKING AND BRIDGING REQ'D OF ALL
COLD-FORMED JOISTS. SEE DETAIL .6
S7
12"
HSS4X4X3/16
HSS4X4X3/16
HSS4X4X3/16
L3 X
3X 1/
L3 X
3X 1/
L3 X
3X 1/
L3 X
3X 1/
S15
S15
34"
TYP
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S3
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A B C
A B C
S3
FRAMING PLAN
LEVEL 02
S3
FRAMING PLAN
ROOF
W10X19
C10X15
W10X19
W12X35
W10X19
W12X35
W12X35
W12X35
W10X19
W
X
W
X
W
X
W
X
W 8X
W
X
W 8X
W
X
W 8X
W
X
W 8X
W
X
W10X19
W12X35
W12X35
W
X
W
X
W
X
W
X
C
X
W
X
W
X
W
X
W
X
/2
C
X
12"
TYP
24'-0"18 @ 16" O.C. = TYP
W10X19
'-0
'-0
'-0
'-0
13'-0" 13'-0"
'-0
'-0
'-0
'-0
13'-0" 13'-0"
7'-9" 6'-8 1/2"
12"
48"3 @ 16" =
13 1/4"
32"2 @ 16" =
13" 12'-0"9 @ 16" =
S4
S4
S4
S4
S4
S4
S4
S4
W10X19
W10X19
S7
S8
S9
S10
S10
R O
T A
T E
T O
M A
T C
H R
O O
F S
LO
P
E R
O T
A T
E T
O M
A T
C H
R O
O F
S
LO
P E
R O
T A
T E
T O
M A
T C
H R
O O
F S
LO
P
E R
O T
A T
E T
O M
A T
C H
R O
O F
S
LO
P E
S6
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S4
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
1 2 3 4 5
5 4 3 2 1 A B C
W10X19 W10X19 W10X19 W10X19
W10X19 W10X19 W10X19 W10X19
W8X10 W8X10 W8X10 W8X10
W
X
W
X
W
X
W
X
W
X
W10X19 W10X19 W10X19 W10X19
W10X19 W10X19 W10X19 W10X19
W8X10 W8X10 W8X10 W8X10
W
X
W
X
W
X
W
X
W
X
HSS
4X
4X 3/
16 HSS4X4X3/16 HSS
4X
4X 3/
16 HSS4X4X3/16
HSS4X
4X
3/
16 HSS4X4X3/16
HSS4X
4X
3/
16 HSS4X4X3/16 HSS4X
4X 3/
16 HSS4X4X3/16
HSS4X
4X
3/
16 HSS4X4X3/16
S4
STRUCTURAL ELEVATION
GRID C
S4
STRUCTURAL ELEVATION
GRID A
S4
STRUCTURAL ELEVATION
GRID 1
T.O. BEAM
EL. 0' - 9 1/8"
T.O. BEAM
EL. 0' - 9 1/8"
T.O. BEAM
EL. 11' - 10 1/8"
T.O. BEAM
EL. 11' - 10 1/8"
T.O. BEAM
EL. (22' - 3 31/32")
T.O. BEAM
EL. (24' - 5 31/32")
W10X19
W10X19 W10X19
W8X35 W8X35
W
X
W
X
W
X
HSS4X
4X
3/1
6 HSS4X4X3/16
T.O. BEAM
EL. 11' - 10 1/8"
T.O. BEAM
EL. 0' - 9 1/8"
B.O. BASE PL
EL. 0' - 0"
B.O. BASE PL
EL. 0' - 0"
B.O. BASE PL
EL. 0' - 0"
W10X19
W10X19 W10X19
W8X35 W8X35
W
X
W
X
W
X
HSS4X
4X
3/1
6 HSS4X4X3/16
T.O. BEAM
EL. 11' - 10 1/8"
T.O. BEAM
EL. 0' - 9 1/8"
B.O. BASE PL
EL. 0' - 0"
C B A
S4
STRUCTURAL ELEVATION
GRID 5
BF-
5 BF-4 BF-
4 BF-5
BF-
1 BF-1
BF-7 BF-6
BF
-3
BF-2 BF
-2
BF-3
BF-
1 BF-1
BF-6 BF-7
W10X19
W10X19
S12
S12
S11
S12
S11
S11
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S5
CODE 2370
ENGINEERING DIVISION
NTS
B
S5
TYP BP3-TO-BEAM CONNECTION
NOTE: JOISTS NOT SHOWN FOR CLARITY
COLUMN, W10X33
NO WELD
IN k-AREA
1/4 1/4
1/4
1/4
S5
TYP BP2-TO-COLUMN CONNECTION
NOTE: BEAMS NOT SHOWN FOR CLARITY
8" 12 1/2"
8"
COLUMN PER PLAN
NO WELD
IN k-AREA
1/4 1/4
1/4
1/4
S5
TYP BP1-TO-COLUMN CONNECTION
NOTE: BEAMS NOT SHOWN FOR CLARITY
BASE PLATE, PL 1"
BASE PLATE, PL 1"
12 1/2" 12 1/2"
BEAM, W8X35
(4) 1" THRU HOLES
(4) 1" THRU HOLES
12"
6"
3"
6"
4 SIDES 1/4 BASE PLATE, PL 1"
30v
BEAM, W8X35COLUMN,
W10X33
2"
2 1/4"
R 1"
1/4 3 1/2 1/4 3 1/2
3/8
12 1/2"
3/8 5
S5
TYP BEAM-TO-COLUMN FLANGE AT BASE PLATE
NOTE: INDICATED AS MOMENT CONNECTION ON FRAMING PLAN
(2) CONTINUITY PLATES,
SEE DETAIL 3
S8
CONTINUITY PL
S5
TYP BEAM-TO-COLUMN WEB AT BASE PLATE
NOTE: SEE DETAIL 6 (THIS SHEET) WHEN IN WAY OF GUSSET
S5
TYP BEAM-TO-COLUMN WEB AT BASE PLATE
IN WAY OF GUSSET PLATE (COLUMNS 2A, 2C, 4A & 4C)
1/4
EXTENDED SHEAR TAB,
SEE DETAIL
T.O. BEAM
EL. 9 1/8"
DOUBLER PL EACH
SIDE OF COLUMN,
SEE DETAIL 4
S8
1/4TYP
DOUBLER PL
S5
BEAM, W8X10
COLUMN, W10X33
BASE PLATE
GUSSET PL PER SCH
BEAM, W8X101/2"
1/2"
SEE DETAIL
BEAM, W8X10
S5
S5
BEAM STUB TOP FLANGE,
SEE DETAIL
CONTINUITY PLATE
BEAM STUB WEB
PLATE, PL 1/4"
BEAM SHEAR SPLICE,
SEE DETAIL
1/4 1/4
S5
TYP BEAM SHEAR SPLICE DETAIL
IN WAY OF BEAM STUBS AT LEVEL 01
S5
TYP BEAM SHEAR SPLICE DETAIL
IN WAY OF BEAM STUBS AT LEVEL 02
2"
2"2 1/4"2"
1 1/2"
1 1/2"
2"
1/2"
BEAM SHEAR SPLICE
PLATE, PL 1/2"
1/4"
TYP
4 3/4"
1/43 SIDES
BEAM, W10X19
BEAM STUB
PER DETAIL
BEAM CL
(4) 3/4"O BOLTS,
ASTM A325
2 3/4" 2" 1 1/2"
BEAM STUB
FLANGE PL
BEAM STUB
WEB PL
1/2"
1 1/2"4 @ = 6"
BEAM, W8X10
BEAM SHEAR SPLICE
PLATE, PL 1/2"
BEAM CL
3 SIDES 1/4
S5
6"
6"
6" 6"
6"
6"
6" 6"
DOUBLER PL
S5
TYP EXTENDED SHEAR TAB CONNECTION
IN WAY OF BEAM-TO-COLUMN CONNECTION
COLUMN, W10X33
EXTENDED SHEAR TAB, PL 1/2"
CONTINUITY OR
WEB STIFFENER PL
1/2" 2" 1 1/2"
BEAM PER PLAN
BEAM CL
1 1/2"4 @ = 6"
1/4 1/4
(2) 3/4"O BOLTS,
ASTM A325
CONTINUITY OR
WEB STIFFENER PL
R 1/2" TYP
(2) 3/4"O BOLTS, ASTM A325
TYP1/4
TYP1/4
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S6
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
BEAM CL
1 1/2"2 @ = 3"
1" MAX, TYP
T.O. BEAMS
EL. 11' - 10 1/8"
BEAM, W10X19
STAIR
OPENING
3 SIDES1/4
BEAM, C10X15
1/4
(2) 1/2"O ERECTION
BOLTS, REMOVE
AFTER WELDING
BEAM CL
T.O. STEEL
EL. 11' - 10 1/8"
S6
TYP CHANNEL-TO-CHANNEL CONNECTION
IN WAY OF STAIRS
BEAM, W12X35
C10X15
1 1/2"
BEAM CL
BEAM PER PLAN
S6
TYP SHEAR TAB CONNECTION
NOTE: IN WAY OF BEAM-TO-COLUMN FLANGE CONNECTION
1/4 1/4
COLUMN,
W10X33
SHEAR TAB, PL 3/8",
MATCH BEAM'S SLOPE
2"
TABLE S6: SHEAR CONNECTION SIZING
BEAM TYPE # BOLTS LENGTH (in)
W8 2 6 W10 2 6 W12 3 9 C10 2 6
# OF 3/4"O BOLTS
ASTM A325 PER
TABLE S6
LENGTH PER TABLE S6
CLIP IN WAY
OF BEAM
k-AREA, TYP
1 1/2"2 @ = 3"
1/2"
1 1/2"4 @ = 6" SHOWN
1/2"
1 1/2"4 @ = 6" SHOWN
LENGTH PER TABLE S6
1/4 1/4
EXTENDED SHEAR TAB, PL 1/2"
BEAM CL
BEAM PER PLAN
# OF 3/4"O BOLTS
ASTM A325 PER
TABLE S6
BEAM PER PLAN
R 1/2" TYP
S6
TYP EXTENDED SHEAR TAB CONNECTION
IN WAY OF BEAM-TO-BEAM CONNECTION
T.O. STEEL
EXTENDED SHEAR TAB,
SEE DETAIL
BEAM, C10X15
1/2"
EXTENDED
SHEAR TAB
R 1/2" TYP
TYP CLIP ANGLE CONNECTION
NOTE: IN WAY OF BEAM-TO-COLUMN WEB CONNECTION
# OF 3/4"O BOLTS ASTM
A325 PER TABLE S6
BEAM CL
1 1/2"4 @ = 6" SHOWN
CLIP ANGLE, L4X3X3/8
1 1/2"2"
LENGTH PER TABLE S6
1/4
CLIP ANGLE, L4X3X3/8
1 1/2"4 @ = 6" 2"1 1/2" 1/2"
BEAM, C10X15
COLUMN,
W10X33
1/2"
WEB STIFFENER,
PL 1/2"
S6
TYP WEB STIFFENER DETAIL
1/4 1/4
COLUMN,
W10X33
2 5/8"
TYP
1 3/8"
TYP
S6
TYP BEAM STUB DETAIL
IN WAY OF GUSSETS AT LEVEL 02 SHOWN
BEAM SHEAR SPLICE, SEE DETAIL
BEAM CL
GUSSET PL PER SCH
BEAM STUB WEB, PL 1/4",
CENTER WITH BEAM WEB
1/4 TYP1/4
MATCH BEAM bf
1/4 TYP1/4
1/4 1/4
1/4 1/4
BEAM STUB FLANGE, PL 1/2"
GUSSET NOT SHOWN
FOR CLARITY
1/4 1/4
45° BEAM PER PLAN
45°
S5
MATCH BEAM
DEPTH, UNO
CUTOUTS ARE SAME AS
TYP WEB STIFFENER
1/2"COLUMN,
W10X33
T.O. STEEL
NOTE: THIS CONNECTION IS
ONLY USED WITH ROOF
FRAMING CONNECTIONS.
S6
STAIR OPENING FRAMING CONNECTIONS
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S7
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A
B
C
T.O. BEAM
EL. (24' - 5 31/32")
T.O. BEAM @ GRID
EL. 23' - 5"
T.O. BEAM
EL. (22' - 3 31/32")
PADEYE,
SEE DETAIL
PADEYE,
SEE DETAIL
BEAM, W8X10,
ROTATE TO MATCH
ROOF SLOPE, TYP
CL
6" 12"
6 1/2"
10"
R 3 1/2"
O 2 1/2"
S7
PADEYE DETAIL
PADEYE, PL 2"
ASTM A572 GR. 50
1/2"
1/2"
S7
TYP PADEYE CONNECTION DETAIL
BEAM, W10X19
METAL ROOF
DECK, CUT IN
WAY OF PADEYES
5/8 5/8
3/8
3/8
S7
S7
3/16
3/16
3/16
3/16
3/16
3/16
GUSSET
CLIP ANGLE,
SEE DETAIL 2
S6
TOP PLATE, PL 1" x 13" x 9", CENTER OVER COLUMN
S6
BRACE
COLUMN,
W10X33
BRACE
COLUMN,
W10X33
GUSSET
SHEAR TAB, SEE
DETAIL
EXTENDED SHEAR TAB,
SEE DETAIL 1
S6
SHEAR TAB,
SEE DETAIL
BEAM, W12X35
BEAM, W10X19
S7
SECTION - ROOF FRAMING AT GRID 4
NOTE: GRID 2 SIMILAR
TYP COLD-FORMED JOIST
1/16TYP 1/16
1-4 1-4
SOLID BLOCKING, DEPTH EQUAL
TO OR LESS THAN JOIST DEPTH
x 64 mil THK, FIT BETWEEN FIRST
TWO AND LAST TWO BAYS
WITHIN 6" OF JOIST HANGERS
AND AT CENTER OF JOISTS
1/16 TYP1/16
1-4 1-4
BRIDGING STEEL
STRAP 16 GA. x 3"
WIDE, CONTINUOUS
BETWEEN JOIST
BLOCKING
1/16 TYP1/16
NOTE: BLOCKING AND BRIDGING OF ALL COLD-FORMED JOISTS IS REQ'D.
SETS OF JOISTS THAT ARE PARALLEL AND START & STOP IN-LINE WITH
EACH OTHER MAY BE BLOCKED AND BRIDGED TOGETHER.
S7
TYP COLD-FORMED JOIST BLOCKING & BRIDGING
COLD-FORMED JOIST
JOIST HANGER, A KNOWN
SOURCE IS SIMPSON S/HJCT
PER MFR
(4) #14 x 1" SCREWS
S7
TYP JOIST-TO-BEAM DETAIL
S7
TYP JOIST-TO-COLUMN WEB DETAIL
COLD-FORMED JOIST
JOIST HANGER, A KNOWN
SOURCE IS SIMPSON S/HJCT
(4) #14 x 1" SCREWS
COLUMN, W10X33
S6
13"
MT
MT
MT
MT
MT
MT
MT
MT
PADEYE, CENTER
OVER COLUMN WEB
MT OF ENTIRE PARENT
MATERIAL OF PADEYE
PER MFR
TYP WEB STIFFENER
OR CONTINUITY PL
3/8 3/8
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S8
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
1/2"
R 1/2"
R 1/2"
3/ 4"
1/2"
3/ 4"
BEAM TOP
FLANGE
BEAM
BOTTOM
FLANGE
S8
TYP WELD ACCESS HOLE DETAIL
NOTE: SAME AS TYPE 'A' OF AISC SEISMIC DESIGN MANUAL
(2) DOUBLER
PLATES EACH
SIDE OF COLUMN,
SEE DETAIL
S8
TYP MOMENT CONNECTION DETAIL
SEE DETAIL 1 ON SHEET S10 FOR 2-BOLT CONNECTION
1 1/4" 1/2"
1 1/4"
T.O. STEEL
EL. 11' - 10 1/8"
S8
MOMENT CONNECTION DETAIL
IN WAY OF COLUMNS 2A, 2C, 4A & 4C AT LEVEL 02
1 1/2"4 @ = 6"
1/2"
CONTINUITY PLATE, PL 1/2"
COLUMN
PER PLAN
2 1/2"1 1/2"
1 1/2"
3"
3"
1 1/2"
BEAM CL
1/4 1/4
CJP
30v
SHEAR TAB,
PL 3/8"
(3) 3/4"O BOLTS,
ASTM A325
S8
BEAM, W12X35
BEAM, W10X19
EXTENDED SHEAR TAB
OR BEAM STUB WEB
1/16"
MAX
TYP
2 1/2"
TYP
(4) DOUBLER
PLATES, PL 1/4"
TYP CONTINUITY PL DETAIL
S8
TYP DOUBLER PL DETAIL
COLUMN
PER PLAN
BEAM, W10X19
1/4 1/4
1/4 1/4
(2) 3/4"O BOLTS,
ASTM A325
R 1/2"
1 1/2"
EXTENEDED
SHEAR TAB, PL 3/8"
TYP 1/4
S8
TYP DOUBLER-TO-CONTINUITY PLATES
C COLUMN WEBL
CONTINUITY PL OR
BEAM STUB FLANGE PL
TYP1/4
CONTINUITY PL
DOUBLER PL
MOMENT CONNECTION NOTES:
1. LOCATION OF MOMENT CONNECTIONS IS
INDICATED ON FRAMING PLAN VIEWS.
2. ONLY BEAMS FRAMING INTO COLUMNS SHOWN IN
MOMENT CONNECTION DETAILS FOR CLARITY.
BRACES AND GUSSETS NOT SHOWN.
3. THERMALLY CUT SURFACE ROUGHNESS SHALL
NOT EXCEED 500 �-in IN ACCORDANCE WITH ANSI B46.1.
4. BACKING AT BEAM FLANGES SHALL NOT BE
WELDED OR TACK WELDED TO THE BEAM FLANGE.
ATTACH THE BACKING ONLY TO THE COLUMN
FLANGE.
5. WELD TABS, WHERE USED, SHALL BE REMOVED IN
ACCORDANCE WITH AWS D1.8 CLAUSE 6.11.
6. WITH THE EXCEPTION OF CONTINUITY PLATE
WELDS, MT THE ENDS OF THE WELDS WHERE WELD
TABS ARE REMOVED.
4"
S8
S8
1/4 1/4
1/4 1/4
1/16"
MAX
TYP
ALIGN CONTINUITY PLATES
WITH MOMENT FRAME
BEAM'S FLANGES, TYP
(2) CONTINUITY PLATES
EACH SIDE OF COLUMN,
SEE DETAIL
EXTENDED SHEAR TABS MAY BE PLACED ON
EITHER SIDE OF BEAM WEBS, BUT OPPOSING
TABS AT A COLUMN MUST BE LOCATED ON
THE SAME SIDE AS SHOWN HERE
1 3/8" TYP
2 5/8"
TYP
NOTE: IF NO EXTENDED SHEAR TAB
OR BEAM STUB WEB PRESENT, USE
A SINGLE DOUBLER PLATE
BETWEEN COLUMN FLANGES.
CJP
30v S8
S8
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S9
CODE 2370
ENGINEERING DIVISION
S9
TYP MOMENT CONNECTION DETAIL
IN WAY OF COLUMNS 3A & 3C AT LEVEL 02
COLUMN,
W10X33
(2) DOUBLER
PLATES EACH
SIDE OF COLUMN,
SEE TYP DETAIL
BEAM STUB, SEE
DETAIL
BEAM STUB FLANGES ACT
AS CONTINUITY PLATES
S8
S6
BEAM, W12X35
T.O. STEEL
EL. 11' - 10 1/8"
S8
NOTE: BRACES AND GUSSETS
NOT SHOWN FOR CLARITY.
SET BEAM STUB DEPTH
TO MATCH MOMENT
FRAME FLANGES
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S10
CODE 2370
ENGINEERING DIVISION
S10
TYP MOMENT CONNECTION DETAIL
IN WAY OF COLUMNS 1A, 1C, 5A & 5C AT LEVEL 02
S10
TYP MOMENT CONNECTION DETAIL
IN WAY OF COLUMNS 1B & 5B AT LEVEL 02
(4) CONTINUITY PLATES
COLUMN, W10X33
BEAM STUB FLANGES ACT
AS CONTINUITY PLATES
BEAM, W10X19
T.O. BEAM
EL. 11' - 10 1/8"
NOTE: BRACES AND GUSSETS
NOT SHOWN FOR CLARITY.
(2) CONTINUITY PLATES
S8
BEAM, W10X19 BEAM, W10X19
COLD-FORMED JOIST
COLUMN,
W10X33
S8
S8
T.O. BEAM
EL. 11' - 10 1/8"
1 1/2"4 @ = 6"
2 1/2"1 1/2"
SIM SIM SIM
NOTE: MOMENT CONNECTIONS ALONG
GRIDS 1 AND 5 AT LEVEL 02 DO NOT
REQUIRE DOUBLER PLATES.
(2) 3/4"O BOLTS,
ASTM A325
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S11
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A
B
L2
L1
S1
GUSSET, PL 1/4"
WELD GAP
AS REQ'D
BRACE,
HSS4X4X3/16
S2
Lb
S11
TYP GUSSET DIMENSIONING DETAIL
W.P.
BASE PLATE
BEAM STUB WEB
BEAM, W8X10
COLUMN, W10X33
GUSSET PL #1 PER SCH
1/4 1/4
BRACE1/4
1/4
WEB STIFFENER,
SEE DETAIL
S11
GUSSET PLATE CONNECTION DETAIL
IN WAY OF COLUMNS 2A, 2C, 4A & 4C AT GROUND LEVEL 01
S6
BRACE CL
W.P.
GUSSET PL #9
PER SCH
BEAM CL
BRACE CL
BEAM-TO-COLUMN
MOMENT CONNECTION,
SEE DETAIL
1/4 1/4
1/4 1/4
S11
GUSSET PLATE CONNECTION DETAIL
IN WAY OF COLUMNS 1A, 1C, 5A & 5C AT LEVEL 02
BRACE
S11
GUSSET PLATE CONNECTION DETAIL
IN WAY OF COLUMNS 1A, 1C, 5A & 5C AT LEVEL 02
S10
COLUMN,
W10X33
3/16 3/16
3/16 3/16
2" 1/4"
GAP, T
YP
BRACE
S11
TYP BRACE-TO-GUSSET CONNECTION
1/2" ERECTION BOLT
AS REQ'D, REMOVE
AFTER WELDING
BRACE CL
GUSSET PL
BEAM STUB TOP FLANGE, BASE
PL REPLACES BOTTOM FLANGE
BEAM STUB
PER DETAIL
BEAM
SHEAR
SPLICE
BEAM, W10X19
BEAM CL
1/4 1/4
1/4 1/4
COLUMN,
W10X33
GUSSET PL PER SCH
W.P.
BR
AC
E
CL
BRACE
WEB STIFFENER,
SEE DETAIL 6
S6
S11
GUSSET PL THK + 1/8"
GUSSET PL
SMOOTH TRANSITION
TO RADIUS
Lb
S11
TYP BRACE SLOT DETAIL
IN WAY OF GUSSET PL
BRACE
EQ
EQ
BEAM, W10X19
BEAM, W8X10
BRACED BAY #
BRACE SHAPE
# OF OCCURANCES
BAY HEIGHT (in)
BAY LENGTH (in)
APPROXIMATE BRACE LENGTH (in)
GUSSET LOCATION Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top
GUSSET # 1 2 3 4 5 5 6 7 8 8 9 10 9 11
tgusset (in) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
A (in) 9.301 9.301 9.307 9.307 9.308 9.308 9.795 9.295 9.293 9.293 9.225 9.225
B (in) 15.403 19.646 16.688 14.923 15.040 15.040 20.733 18.134 18.301 18.301 12.170 12.170
L1 (in) 2.435 0.489 2.676 3.368 3.291 3.291 0.483 0.988 0.850 0.850 3.109 3.109
L2 (in) 7.917 10.039 8.235 7.353 7.427 7.427 10.881 9.345 9.448 9.448 6.722 6.722
Lb (in) 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000
S1 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000
S2 5.158 8.037 5.743 4.621 4.704 4.704 8.556 7.093 7.234 7.234 3.191 3.191
Weld Gap (in) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Weld Size Brace-to-Gusset (in) 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16
Weld Size Beam-to-Gusset (in) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Weld Size Column-to-Gusset (in) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
140.115
156.000
TABLE S11: GUSSET PLATE SCHEDULE
HSS4X4X3/16 HSS4X4X3/16 HSS4X4X3/16 HSS4X4X3/16 HSS4X4X3/16 HSS4X4X3/16 HSS4X4X3/16
2 2
120.000 120.000 120.000 120.000 120.000 156.000
125.833 140.115
BF-3 BF-4
4 2 2 2
130.813 152.958 151.833 126.958
BF-5 BF-6 BF-7BF-1 BF-2
S E
E D
E T
A
IL
S E
E D
E T
A
IL
183.042155.951 173.003 173.478 150.446 151.755 185.688
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S12
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
S12
TYP GUSSET PL CONNECTION DETAIL
IN WAY OF COLUMNS 2A, 2C, 4A & 4C AT ROOF
S12
GUSSET PL CONNECTION DETAIL
IN WAY OF COLUMNS 1B & 5B AT ROOF
S12
GUSSET PL CONNECTION DETAIL
IN WAY OF COLUMNS 3A & 3C AT LEVEL 02
BEAM STUB
HALF DEPTH
W.P.
BRACE CL
LBEAM C
PADEYE, SEE DETAIL
CLIP ANGLE, SEE
TYP DETAIL
BEAM, W10X19
COLUMN TOP PL
W.P.
BR
AC
E
CL
WEB STIFFENER,
SEE DETAIL 6
S6
BRACE
GUSSET PL PER SCH
S6
BRACE CL
BRACE CL
BRACE CL BR
AC
E
CL
1/4 TYP1/4
COLUMN,
W10X33 1/4 TYP1/4
B
BEAM, W10X19
BRACE CL
BRACE CL
BEAM CL
W.P.
BRACE
GUSSET PL #11, SEE DETAIL
1/4 TYP1/4
1/4 TYP1/4
BEAM, W10X19
9 13/16"
7 13/16"
13 3/4"
5 15/16"
2"
6 5/8"
1"
8 13/16"
5 7/8"5"
10 7/8"
4 1/8"
5 5/8"
1"
S12
GUSSET PLATE #10 DETAIL
BF-6 UPPER GUSSET PLATE
S12
GUSSET PLATE #11 DETAIL
BF-7 UPPER GUSSET PLATE
GUSSET PL #10,
SEE DETAIL 4
S12 5 S12
BEAM, W10X19
COPE BEAM IN WAY OF TOP PLATE, TYP
S7
GUSSET PL GUSSET PL
BRACE
BRACE
LBEAM C
BEAM, W10X19
BRACE
BRACE
COLUMN,
W10X33
BRACE
COLUMN,
W10X33
MATCH BEAM STUB
DEPTH TO TRANSVERSE
BEAM, SEE DETAIL 1
S9
DOUBLER
PLATES
BEAM, W10X19
BEAM SHEAR SPLICE,
SEE DETAIL 8
S5
WEB STIFFENERS
BRACE
BRACE BRACE
GUSSET PL PER SCH
GUSSET PL PER SCH
GUSSET PL PER SCH GUSSET PL
PER SCH
GUSSET PL PER SCH
WEB STIFFENERS
1/4 TYP1/4
1/4 TYP1/4
SHEAR TAB, TYP,
SEE DETAIL 3
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S13
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
A B C
A B C
S13
DECK PLATE PLAN
LEVEL 01
S13
DECK PLATE PLAN
LEVEL 02
PL 1/4" PL 1/4"
PL 1"
64" 8"
8"
8"
/4
7'-9 1/4" 6'-8 3/4"
8"
S14
S14
S14
S14
S14
1/4" 1/4"
1/4"
1/2"
GUSSET PL
COLUMN,
W10X33
BEAM
PER PLAN
DECK PLATE
PER PLAN
S13
TYP DECK PL DETAIL
IN WAY OF COLUMN
DIMENSIONS IN DECK PLATE
PLANS LOCATE EDGE OF
DECK PLATE TO GRID LINES
S15
PL 1/4"
S15
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S14
CODE 2370
ENGINEERING DIVISION
NTS
SHEET
BEAM PER PLAN
DECK PLATE
PER PLAN
1/4
BEAM CL
JOIST CL
COLD-FORMED
JOIST PER PLAN
DECK PLATE,
PL 1/4"
S14
TYP DECK SPLICE DETAIL
IN WAY OF COLD-FORMED JOIST
S14
TYP DECK SPLICE DETAIL
IN WAY OF W-SHAPE BEAM
3/16
S14
TYP DECK PERIMETER DETAIL
IN WAY OF C-SHAPE BEAM
A B C
1/2" TYP
S14
DECK PLATE PLAN
ROOF
S14
DECK SPLICE DETAIL
IN WAY OF RAISED DECK
S14
TYP DECK PERIMETER DETAIL
IN WAY OF GUSSET PLATES
METAL ROOF DECK IS 1 1/2" x 16GA., TYPE B, GALVANIZED METAL. ATTACH DECK TO
SUPPORT MEMBERS WITH 1/2" EFFECTIVE
DIAMETER ARC SPOT WELDS IN A 36/4
PATTERN. SIDE LAPS SHALL BE CONNECTED
BY BUTTON PUNCH METHOD, MAXIMUM 24"
SPACING BETWEEN PUNCHES.
BEAM PER PLAN
S14
TYP DECK PERIMETER DETAIL
BEAM, C10X15
3/16
3/16 1-8
DECK PLATE
PER PLAN
3/16 1-8
GUSSET PLATE
PER SCH
3/16 1-8
3/16 1-8
DECK PLATE
PER PLAN
3/16 1-8 3/16 1-8
DECK PLATE
PER PLAN
3/16 1-8
1/4
3/16 1-8 3/16 1-8
DECK PLATE,
PL 1/4"
BEAM, W8X10
S14
TYP DECK PERIMETER DETAIL
IN WAY OF GIRTS AT DOORWAYS
DECK PLATE PER PLAN
GIRT
BEAM PER PLAN
DECK PLATE
PER PLAN
1/4
BEAM CL
JOIST CL
COLD-FORMED
JOIST PER PLAN
DECK PLATE,
PL 1/4"
S14
TYP DECK CONNECTION DETAIL
IN WAY OF COLD-FORMED JOIST
S14
TYP DECK CONNECTION DETAIL
IN WAY OF W-SHAPE BEAM
3/16
3/16 1-8 3/16 1-8
1/16 1/16
1-8 1-8
1/16 1-8 1/16 1-8
BEAM PER PLAN
DECK PLATE
PER PLAN
3/16 1-8 3/16 1-8
1/4"
8"
8" 8"
8"
4 1/4"
DECK PLATE, PL 1"
-1
NO DEVIATIONS SHALL BE MADE
WITHOUT CODE 2370 APPROVAL
DRAWING NO.
TITLE
SCALE
D W
G . N
O
T
IT
LE
R
E V
2370-1805
ORIG
O R
IG
PUGET SOUND NAVAL SHIPYARD
REV.
CHANGE HOUSE ENCLOSURE
C H
A N
G E
H O
U S
E E
N C
LO
S
U R
E
S15
CODE 2370
ENGINEERING DIVISION
NTS