This document outlines specifications for a microbial chemostat procurement opportunity. The Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Midwest Area is seeking a parallel four-vessel bacterial bioreactor system not exceeding 750mm x 520mm x 960mm in size, with each 0.75L vessel equipped for temperature control, rotation speeds of two impellers, and up to 13 ports for sensors. The system must include a touchscreen controller to display all bioreactors, digital instrumentation controlling up to 24 parameters per vessel and up to four pumps per vessel, and allow for aseptic sampling and operation without laminar flow or dead volume. Installation and onsite training must be completed within 180 days of award under solicitation number 12505B23Q0229, with all associated costs included in the quote. Delivery is required to the USDA facility at 1920 Dayton Avenue, Building 24 in Ames, Iowa within 150 days of award.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Clauses and Provisions.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications Project: Procurement of Microbial chemostat
GENERAL INFORMATION
1.0 Scope of Work: Our current research requires the ability to simulate gut conditions in vitro to study bacterial population from animal intestines. A chemostat (bioreactor) will allow us it establish cultures of mixed bacterial population to test hypotheses.
2.0 Background: Many years ago, a chemostat was used in our lab to culture mixed bacterial populations. The system no longer functions and requires replacement.
Market research was completed by a team of USDA scientists to identify the capabilities and to identify units that are highly dynamic and could run multiple cultures in parallel.
CONTRACTOR REQUIREMENTS
3.0 Technical Requirements/Tasks:
• Bacterial Bioreactor must be equal to or less than (W x D x H) 750 mm x 520 mm x 960 mm
• Bacterial Bioreactor must have parallel bioreactors with 4 vessels, and each vessel needs to be 0.75 L
• Bacterial Bioreactor must have touch screen controller that display all bioreactors at once
• Bacterial Bioreactor must have a digital instrumentation that controls up to 24 parameters per vessel
• Bacterial Bioreactor must utilize up to 4 pumps per vessel
• Bacterial Bioreactor must have aseptic operation with aseptic sampling without laminar flow and no dead volume
• Bacterial Bioreactor must have drive and temperature control and Bottom drive has magnetic coupling
• Bacterial Bioreactor must have temperature control using heating blocks in combination with cooling water
• Bacterial Bioreactor must have range of rotation speed with 2 impellors
• Bacterial Bioreactor must have stainless steel top plate, with up to 13 ports for sensors
• Bacterial Bioreactor must have simultaneous pH and pO2 sensor calibration for
• all bioreactors
• Bacterial Bioreactor must have automatic filling and emptying of the reagent hoses
• Bacterial Bioreactor must display all parameters as trend lines on graphics
• All anticipated charges pertaining to onsite installation shall be included with quote
• All anticipated charges pertaining to conducting a single USDA staff training on the system shall be included with quote
• Qty: 1 system
4.0 Government Furnished: Staff shall be provided to escort installation and training personnel while onsite in the Federal facility.
5.0 Deliverables/Schedule: Delivered on site within 150 days of date of award and onsite installation and training completed within 180 days of date of award
6.0 Technical Point of Contact: Should there be technical questions, please contact
Torey Looft torey.looft@usda.gov 513-254-7997
7.0 Place of Delivery: USDA, 1920 Dayton Avenue, Bldg 24, Ames, IA 50010 mailto:torey.looft@usda.gov
| CONTRACTOR REQUIREMENTS |
| 3.0 Technical Requirements/Tasks: |
File details come from the government source that posted it. Updated .