STATEMENT OF WORK

(PRODUCT)

GENERAL INFORMATION.

1.0 SCOPE OF WORK.

Features, Components, Accessories, Modules, Software and/or Services to be included:

2.0 BACKGROUND.

CONTRACTOR REQUIREMENTS.

3.0 TECHNICAL REQUIREMENTS/TASKS. Technical Specifications/Salient Characteristics:

4.0 GOVERNMENT FURNISHED.

5.0 DELIVERABLES/SCHEDULE.

KEY DELIVERABLES:

Item No. Deliverable Objective Due

6.0 TRAVEL.

7.0 CONTRACTOR’S KEY PERSONNEL.

8.0 SECURITY REQUIREMENTS.

9.0 DATA RIGHTS.

10.0 SECTION 508 – ELECTRONIC AND INFORMATION TECHNOLOGY STANDARDS.

11.0 SECTION 889 OF THE NATIONAL DEFENSE AUTHORIZATION ACT CERTIFICATION

Text1: Bench-top Automatic Gas Pycnometer
Text2: Vendor is to deliver a bench-top automatic gas pycnometer for measuring true volume and density of porous solid samples.
Text13: Gas pycnometer is a device used in measuring the true volume and true density of porous solids. The pycnometer has two gas-tight chambers or cells, one cell for the sample and the other, an expansion cell with a fix volume. Pressurized gas will occupy the empty space in the sample cell and spaces in between (interparticle) and porous spaces within (intraparticle) the sample particles. A valve is opened and the gas will expand to the second cell. The true volume of the sample is calculated from the equilibrium pressure before and after gas has expanded and the known volumes of the empty sample cell and expansion (second) cell. True density is calculated from the true volume and the weight of the sample.
Text4: 1) Automated true volume and density analyzer
Text5: 2) Built in processor and graphical user interface.
Text6: 3) Sample volume range:10 mL to 100 mL
Text7: 4) Certified volume calibration kit
Text8: 5) Pressure transducer
Text9: 6) Two-stage pressure regulator for helium.
Text10: 7) Protection from elutriation of fine powder sample.
Text11: 8) Temperature controller
Text14: 1) Automated gas pycnometer for measuring true volume and density.
Text15: 2) Built in processor and graphical user interface display.
Text16: 3) Programmable data acquisition.
Text17: 4) Sample cells for 10 mL and up to 100 mL samples.
Text18: 5) Calibration volume kit with certification.
Text19: 6) Built in temperature controller: Temperature range from 15 to 50 degrees C.
Text20: 7) Protection from elutriation of fine particles out of the sample cell.
Text21: 8) Pressure transducer accuracy: 0.1% or better.
Text22: 9) Pressure reading resolution: 0.0001 psi
Text23: 10) Two-stage pressure regulator for helium: Western CGA-580,
Text24: output pressure 0- 25 psig.
Text25: 11) Ports for connecting to analytical balance, flash drive, and printer
Text27: Government will be present during delivery and installation of equipment. If needed, the government will supply a standard loading dock to accept delivery of the unit. The government will supply a location with suitable instrument requirements (space, electricity) as needed to operate the instrument. Equipment will be delivered to 1815 North University Street, Peoria, Illinois. Given COVID restrictions, additional requirements will be in place for entrance to the lab. These will be communicated with the equipment supplier. Attempts will be made to ensure that safety is met for all parties and the equipment delivered in a timely manner.
Text29: 2
Text30: 3
Text31: 4
Text32: 5
Text33: 6
Text34: 7
Text35: 8
Text65: None
Text67: A copy of an official government photo ID (State-issued driver’s license or ID card, passport, green card, etc.) must be provided no later than one week before arrival of contract service technician(s) except in the case of emergency service, were only the name of the technician provided via email or telephone will be necessary. Security access to the NCAUR facility will be provided based on this identification requirement. Freight drivers must comply with NCAUR COVID-19 pandemic guidelines to include the wearing of face masks and maintaining 6 foot social distancing.
Text68: N/A
Text66: N/A
Text69: N/A
Text70: Offeror will represent that:

(1) It will not provide covered telecommunications equipment or services to the Government in the performance of any contract, subcontract or other contractual instrument resulting from this solicitation.

(2) After conducting a reasonable inquiry, for purposes of this representation, the Offeror represents that It does not use covered telecommunications equipment or services, or use any equipment, system, or service that uses covered telecommunications equipment or services.

Text29a:
Text30a:
Text31a:
Text32a:
Text33a:
Text34a:
Text35a:
Text28a: Delivery
Text28b: N/A
Text30b:
Text31b:
Text32b:
Text33b:
Text34b:
Text29b:
Text35b:
Text28: 1
Text29c:
Text30c:
Text31c:
Text32c:
Text33c:
Text34c:
Text28c: No later than 120 days after purchase order is provided to the vendor
Text35c:
Text26: 12) Power requirement: 110 VAC
Text101:
Text102:
Text12: 9).Ports for transferring data and connecting to analytical balance and printer.
Text105: 10)