FOPO 253760 – REMOVE RUST AND RECOAT HISTORIC GUARDRAILS – FORT POINT HISTORIC SITE 04/18/2022 PG 1 OF 3
3RD FLOOR LEVEL +/- 27’-0”
2ND FLOOR LEVEL +/- 13’-5”
GROUND LEVEL
INTERIOR COURTYARD HEIGHTS1A
PROJECT LOCATION MAP2
INTERIOR COURTYARD HEIGHTS1B
GUARDRAIL LEVELS OF THIS PROJECT
PROJECT SITE
PHOTOS OF FORT POINT 2nd and 3rd FLOOR GUARDRAILS OVERALL VIEW
LOOKING WEST (14 PANELS EACH FLOOR)
- PANELS ARE NUMBERED FROM 1 TO 14 STARTING AT 1 ON THE
WEST ENDING AT 14 ON THE EAST.
PANEL SIZING (HEIGHT x
LENGTH)
PANEL 01: 3’-0” X 15’-0”
PANEL 02: 3’-0” X 15’-0”
PANEL 03: 3’-0” X 5’-0”
PANEL 04: 3’-0” X 5’-0”
PANEL 05: 3’-0” X 15’-0”
PANEL 06: 3’-0” X 15’-0”
PANEL 07: 3’-0” X 15’-0”
PANEL 08: 3’-0” X 15’-0”
PANEL 09: 3’-0” X 15’-0”
PANEL 10: 3’-0” X 15’-0”
PANEL 11: 3’-0” X 15’-6”
PANEL 12: 3’-0” X 5’-0”
PANEL 13: 3’-0” X 5’-0”
PANEL 14: 3’-0” X 15’-6”
FOPO 253760 – REMOVE RUST AND RECOAT HISTORIC GUARDRAILS – FORT POINT HISTORIC SITE 04/18/2022 PG 2 OF 3
01 03 04
02 05
12 13
PHOTO OF FORT POINT 2nd FLOOR GUARDRAIL LOOKING SOUTH AT PANEL 6
- PANEL ANCHOR SPLICE PLATES TO BRICK MASONRY ARE TYPICAL – CONDITION VARIES, ANCHOR PLATE EMBEDDED IN MASONRY FIELD PAINTING ONLY (NO REPLACEMENT IN CONTRACT). (SEE INSET EXAMPLE DETAIL PHOTO ABOVE RIGHT AND REFERENCE DRAWING DETAILS).
- PANEL UPRIGHT POST ANCHORING CONDITIONS ARE SIMILAR – CUT PANEL UPRIGHT POST LEAVING ANCHORING BASE STUB FOR NEW MENDING SLEEVES.
(SEE INSET EXAMPLE DETAIL PHOTO ABOVE LEFT). ALLOW FOR 3-1/2” LONG 1-1/4” I.D. SLEEVE BOLTED IN TWO PLACES WITH S.S. MACHINE BOLTS – 3 EA. PANEL.