This is a Statement of Work for the NASA ER-2 project requiring updated Self-Contained Breathing Apparatus (SCBA) equipment for hydrazine response operations. The equipment must be inspected, serviced, and recertified annually by a qualified vendor, with current equipment due for recertification in April 2026.
The SCBA equipment must be directly compatible with US Air Force Fire Department SCBA systems to enable cross-utilization, spare parts access, and air bottle refilling at the AFB Fire Department Host Station. Key technical specifications include NIOSH certification under 42 CFR Part 84 for chemical, biological, radiological, and nuclear (CBRN) protection; Universal Emergency Breathing Supply System (UEBSS) capability; 4500 psig operating pressure with a minimum 45-minute duration; single rechargeable battery power source for all components; a Heads-up Display (HUD) facepiece showing cylinder air volume remaining; and a mechanical bell alarm mechanism for low air cylinder pressure indication. The equipment must be delivered to NASA Armstrong Flight Research Center, Building 4876 Warehouse #6, Lilly Drive, Edwards, California 93524, and is needed no later than March 13, 2026. The point of contact is Alberto Rodriguez.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SATPC0040271 Tab 07 Capability Statement SAM.gov.pdf | ||
| SATPC0040271 Tab 06 RDSS..pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
1. Objective/Requirements The NASA ER-2 project requires updated hydrazine response equipment that can be inspected, serviced, and recertified annually by a qualified vendor. The current equipment is no longer supported for these functions and is due for recertification in April 2026.
2. Characteristics, Scope, and Specs Self-Contained Breathing Apparatus (SCBA) Equipment:
• Directly in line with US Air Force Fire Department SCBA Equipment
Allowing cross-utilization in the event we require extra gear and/or our gear is down for maintenance.
Spare air bottles with ability to refill our bottles at the AFB Fire Department Host Station
Compatible inspection equipment Quick access to spare parts
• NIOSH under 42 CFR, Part 84 for chemical, biological, radiological, and nuclear protection (CBRN) Approval
• Universal Emergency Breathing Supply System (UEBSS)
• 4500 psig operating pressure with minimum 45 min duration
• All components of SCBA must be powered from single power source, e.g.
rechargeable battery.
• Facepiece Heads-up Display (HUD) with cylinder air volume remaining indicator
• Mechanical bell alarm mechanism indicating low air cylinder pressure.
3. Place of Performance or Delivery Location NASA Armstrong Flight Research Center Attn: Alberto Rodriguez Bldg 4876 Warehouse #6, Lilly Drive Edwards, CA 93524