DEPTH LOGGERS AND WAVE RECORDERS
SALIENT CHARACTERISTICS:
65 EA, Depth Logger:
· Shall be a submersible single-channel pressure logger capable of intermittent and continuous wave burst measurement & tidal averaging.
· Shall be capable of sampling at speeds up to 16 Hz bursts with wave analysis.
· Battery powered replaceable battery.
· Shall have a pressure measurement range of 20 meters and measurement time constant of less than 10 ms.
· Shall have a pressure accuracy of ±0.05% full scale or better and a resolution of 0.001% full scale or better.
· Shall be capable of USB downloading.
· Shall be capable of storing at least 20 million readings.
1 EA, Temperature and Depth Logger:
· Shall be a submersible two-channel temperature and pressure logger capable of intermittent and continuous wave burst measurement & tidal averaging.
· Shall be capable of sampling at speeds up to 16 Hz bursts with wave analysis.
· Shall be capable of operating on eight (8) user replaceable AA batteries.
· Shall be capable of USB downloading.
· Shall have RS-232/485 communications.
· Shall have a plastic housing.
· Shall have a pressure measurement range of 20 meters and measurement time constant of less than 10 ms.
· Shall have pressure measurement accuracy of ±0.05% full scale or better and resolution of 0.001% full scale or better.
· Shall be capable of measuring temperature of a range of -5 to 35o C.
· Shall have a temperature measurement accuracy of +/-0.002o C, or better.
· Shall be capable of storing at least 200 million readings.
· Shall be no larger than 2.5" in diameter
1 EA, Instrument Case (large):
· Shall be compatible with the depth loggers described above.
· Shall consist of a protective case for transporting the depth loggers.
· capable of housing up to 60 depth loggers.
1 EA, Instrument Case (small):
· Shall be compatible with the depth loggers described above.
· Capable of housing up to 14 depth loggers.
1 EA, Support Kit:
· Shall consist of various spare parts including, but not limited to, o-rings, o-ring grease, o-ring removal tool, desiccant, and USB stick.