DEPTH LOGGERS AND WAVE RECORDERS

SALIENT CHARACTERISTICS:

65 EA, Depth Logger:

· Shall be a submersible single-channel pressure logger capable of intermittent and continuous wave burst measurement & tidal averaging.

· Shall be capable of sampling at speeds up to 16 Hz bursts with wave analysis.

· Battery powered replaceable battery.

· Shall have a pressure measurement range of 20 meters and measurement time constant of less than 10 ms.

· Shall have a pressure accuracy of ±0.05% full scale or better and a resolution of 0.001% full scale or better.

· Shall be capable of USB downloading.

· Shall be capable of storing at least 20 million readings.

1 EA, Temperature and Depth Logger:

· Shall be a submersible two-channel temperature and pressure logger capable of intermittent and continuous wave burst measurement & tidal averaging.

· Shall be capable of sampling at speeds up to 16 Hz bursts with wave analysis.

· Shall be capable of operating on eight (8) user replaceable AA batteries.

· Shall be capable of USB downloading.

· Shall have RS-232/485 communications.

· Shall have a plastic housing.

· Shall have a pressure measurement range of 20 meters and measurement time constant of less than 10 ms.

· Shall have pressure measurement accuracy of ±0.05% full scale or better and resolution of 0.001% full scale or better.

· Shall be capable of measuring temperature of a range of -5 to 35o C.

· Shall have a temperature measurement accuracy of +/-0.002o C, or better.

· Shall be capable of storing at least 200 million readings.

· Shall be no larger than 2.5" in diameter

1 EA, Instrument Case (large):

· Shall be compatible with the depth loggers described above.

· Shall consist of a protective case for transporting the depth loggers.

· capable of housing up to 60 depth loggers.

1 EA, Instrument Case (small):

· Shall be compatible with the depth loggers described above.

· Capable of housing up to 14 depth loggers.

1 EA, Support Kit:

· Shall consist of various spare parts including, but not limited to, o-rings, o-ring grease, o-ring removal tool, desiccant, and USB stick.