S02_PACS Sketches.pdf
PDF 2 MB Posted
- Attached to
- J063--Services for intrusion detection system (IDS) & Physical Access Control (PACS) (SDVOSB Set Aside) Federal contract opportunity
- Solicitation number
- 36C10D24Q0064
- Issued by
- Department of Veterans Affairs
About this file
This document is a set of sketches and a bill of materials for the maintenance and repair of an Intrusion Detection System (IDS) and Physical Access Control System (PACS) at the Department of Veterans Affairs facility located at 477 Michigan Ave, Detroit, Michigan.
The sketches provide detailed floor plans and schematics of the IDS and PACS systems, including the location of various components such as controllers, power supplies, readers, door contacts, and wireless transmitters. The bill of materials lists the specific part numbers and quantities of the required equipment. The government encourages the contractor to field verify the information provided in the sketches. The document also includes important notes, such as the requirement to place the duress system in "test mode" prior to activating any duress buttons, and that certain doors are manually unlocked and accessible to the public during normal business hours.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C10D24Q0064 0001_2.docx | DOCX document | |
| 36C10D24Q0064 0001_1.docx | DOCX document | |
| 36C10D24Q0064 0001.docx | DOCX document | |
| P07_Wage Determination_2015-4839 (Rev-23).pdf | ||
| Solicitation Vendor Q and A Format.xlsx | XLSX spreadsheet | |
| S02_6500 Appendix C.pdf | ||
| S02_Past Performance Questionnaire_.docx | DOCX document | |
| 36C10D24Q0064.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project:
SHEET 1 of 21
Bill of Materials
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
Item No. Part Number Description Quantity Applicable Sheets
1 Z240 Lenel OnGuard WorkStation, L9K19UT#ABA 3.4 GHz i7, 1TB, 8GB 1 SH. 10
2 V246HQL Lenel OnGuard Monitor 24” 1 SH. 10 3 Lenel Software Lenel OnGuard Software 1 SH. 10 4 LNL-2220 Lenel 2-Reader Intelligent Controller 1 SH. 9
5 FPO150/250-2C8D8PE4M1 MCLASS Unified Power System 150W 12/24 VDC 8 Doors
2 SH. 4 & SH. 9
6 FPO150/250-
2C82D8PE8M2
MCLASS Unified Power System 150W 12/24 VDC 8 Doors
3 SH. 4, SH. 7 & SH. 9
7 LNL-1320 Lenel 2-Reader Board 27 SH. 4, SH. 7 & SH. 9
8 920PHRNEK00005 RP40 PIV Class Reader 45 SH. 2, SH. 4-7 & SH. 9-12 9 921PHRNEK0005D RPK40 PIV Class Reader 7 SH 4-5, SH. 9, SH. 10 & SH. 12
10 1076C-N Recessed Steel Door Contact ¾” Diameter, 3/8” Gap SPDT 38 SH. 4-7 & SH. 9-12
11 DS160 Request to Exit Detector 1 SH. 10 12 4500C-12/24-630-LBM ASSA Abloy, Electric Strike 8 SH. 2, SH. 5 & SH. 9-11
13 Mortise electronic lockset (Yale) 25 SH. 4-7 & SH. 9-12
14 6000 Power Matic ASSA Abloy, Electronic Door Operator 17 SH. 4, SH. 6-7 & SH. 9-12 15 Yale, Electronic Panic Bar Hardware 17 SH. 4, SH. 6-7 & SH. 9-12 16 B9412GV4 Bosch IDS Control Panel 1 SH 17 17 B920 Bosch Two-line alphanumeric keypad 1 SH 17 18 B8108A Bosch IDS 16” x 16” Enclosure 1 SH 17 19 B426 Bosch Ethernet Comm Module 1 SH 17 20 Inovonics, Wireless Receiver 1 SH 17 21 269R Honeywell Hold-Up Switch 2 SH 20
22 EN1235SF Bosch, Fixed Location Wireless Transmitter 47 SH 14-18 & SH 21
SHEET 2 of 21
11th floor, plan view, PACS locations
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
8 12
ELEVATOR LOBBY
SHEET 3 of 21
12th floor, plan view, PACS sections
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226 Section 12-1A
Section 12-1B
Section 12-1D
Section 12-1C
MENS RESTROOM
WOMENS RESTROOM
SHEET 4 of 21
12th floor, plan view, sections 12-1A & 12-1B
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
PASSAGEWAY
IT
CLOSET
DAV
CONFERENCE
RM
PA
SS
AG
EW
AY
PA
SS
AG
EW
AY
SHEET 5 of 21
12th floor, plan view, section 12-1C
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
Note 2: The sliding glass door is unlocked manually prior to working hours and can be accessed by public during normal working hours. Once unlocked, the door is opened via motion and does not require
PACS access.
PUBLIC CONTACT
SHEET 6 of 21
12th floor, plan view, section 12-1D
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
PASSAGEWAY
PASSAGEWAY
CONFERENCE
ROOM
VR&E COUNSOLERS
VR&E
COUNSOLERS
VR&E COUNSOLERS
PA
SS
AG
EW
AY
VR&E SECURE
OFFICE SPACE
SHEET 7 of 21
13th floor, plan view, PACS locations
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
MENS RESTROOM
WOMENS RESTROOM
10 14 15 14 15
14 15 14 15
ELEVATOR LOBBY
9 10 13
6 7 (x5)
9 10 13
14 15
14 15
SHEET 8 of 21
14th floor, plan view, PACS sections
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226 Section 14-1A
Section 14-1B
Section 14-1DSection
14-1C
MENS RESTROOM
WOMENS RESTROOM
ELEVATOR
LOBBY
SHEET 9 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
14th floor, plan view, section 14-1A
5 64 7 (x9)
10 139
14 158
14 1510
SECTION 14-1A
BREAK ROOM
PASSAG
EW
AY
PASSAG
EW
AY
10 13
IT
WORKSPACE
IT SERVER RM
IT STORAGE
ROOM
OFFICE OF GENERAL COUNSEL
(OGC)
SHEET 10 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
14th floor, plan view, section 14-1B
SUPPORT SERVICES
DIVISION
PASSAGEWAY
IT
CLOSET
SHEET 11 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
14th floor, plan view, section 14-1C
12 8
10 13
14 1510
SECTION 14-1C
CONFERENCE
ROOM DIRECTORS STAFF
OFFICE
PASSAGEWAY(OGC)
SHEET 12 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
14th floor, plan view, section 14-1D
8 14 15
10 13
14 15
10 139
10 13
SECTION 14-1D
PA
SS
AG
EW
AY
ELEVATOR
LOBBY
IT
CLOSET
PASSAGEWAY
TRAINING ROOM
SHEET 13 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
12th floor, plan view, IDS sections
Section 12-2A
Section 12-2B
Section 12-2D
Section 12-2C
WOMENS RESTROOM
MENS RESTROOM IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode prior to any testing.
SHEET 14 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
12th floor, plan view, section 12-2A
SECTION 12-2A
22 22
American Legion
DAV
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode
SHEET 15 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
12th floor, plan view, section 12-2B
22 22
VVAVFW
MVAA
PVA
OFFICE
VR&E CONFERENCE RM.
VR&&E OFFICE SECURE SPACE
SECTION 12-2B
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode
SHEET 16 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
12th floor, plan view, section 12-2C
PASSAGEWAY
PASSAGEWAY
PASSAGEWAY
EMPLOYMENT SVC CTR
22 22 22
See Note 2 See Note 2 See Note 2
See Note 2 See Note 2
See Note 2
See Note 2
See Note 2 See Note 2 See Note 2 See Note 2
See Note 2 See Note 2
See Note 2
See Note 2
See Note 2
See Note 2 Note 2: Duress buttons in these locations are only accessible from the consoler's entry to the office.
SECTION 12-2C
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode prior to any testing.
VR&E
counselor office (TYP)
VR&E SECURE
OFFICE SPACE
PASSAGEWAY
PUBLIC
CONTACT
SHEET 17 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
12th floor, plan view, section 12-2D
Note 2: Duress buttons in these locations are only accessible from the VA employee’s entry to the room.
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode prior to any testing.
22 22 22
22 22
See Note 2
See Note 2
See Note 2 See Note 2 See Note 2
16 18 20
PUBLIC CONTACT
See Note 3
Note 3: The sliding glass door is unlocked manually prior to working hours and can be accessed by public during normal working hours. Once unlocked, the door is opened via motion and does not require PACS access.
SHEET 18 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
13th floor, IDS locations
MENS RESTROOM
WOMENS RESTROOM
ELEVATOR LOBBY
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode prior to any testing.
PA
SS
AG
EW
AY
SHEET 19 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
14th floor, plan view, IDS sections
Section 14-2A
Section 14-2B
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode prior to any testing.
MENS RESTROOM
WOMENS RESTROOM
SHEET 20 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
14th floor, plan view, section 14-2A
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode prior to any testing.
SUPPORT SERVICES
DIVISION
SECTION 14-2A
SHEET 21 of 21
Sheet Title
Note 1: information, regarding existing conditions, provided on sketches is for reference only and the Government encourages the contractor to field verify
Government provided information
Maintenance & Repair for Intrusion Detection System (IDS) & Physical Access Control System
(PACS)
Department of Veterans Affairs 477 Michigan Ave
Detroit, Michigan 48226
14th floor, plan view, section 14-2B
22 22
SECTION 14-2B
IMPORTANT!
Prior to the contractor activating duress buttons, the contractor must request that the
Government place the duress system into “test mode” & the contractor must receive confirmation from the Government that the duress system is in test mode
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Slide Number 6 |
| Slide Number 7 |
| Slide Number 8 |
| Slide Number 9 |
| Slide Number 10 |
| Slide Number 11 |
| Slide Number 12 |
| Slide Number 13 |
| Slide Number 14 |
| Slide Number 15 |
| Slide Number 16 |
| Slide Number 17 |
| Slide Number 18 |
| Slide Number 19 |
| Slide Number 20 |
| Slide Number 21 |
| Slide Number 22 |
| Slide Number 23 |
| Slide Number 24 |
| Slide Number 25 |
| Slide Number 26 |
| Slide Number 27 |
| Slide Number 28 |
File details come from the government source that posted it. Updated .