S02 Drawing 2 - EP-101_VA Pharmacy SEG_03-19-19.pdf
PDF 128 KB Posted
- Attached to
- 5999--Back Up Generator Install Federal contract opportunity
- Solicitation number
- 36C26223Q1005
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26223Q1005_4.docx | DOCX document | |
| 36C26223Q1005 0003 Amendment to Solicitation.pdf | ||
| 36C26223Q1005_3.docx | DOCX document | |
| 36C26223Q1005 0002 Amendment to Solicitation.docx | DOCX document | |
| 36C26223Q1005 0001.pdf | ||
| 36C26223Q1005_2.docx | DOCX document | |
| S02 Generator Picture.pdf | ||
| VA Form 10091 FMS Vendor.pdf | ||
| S02 Drawing 1 - E-501_VA Pharmacy SEG_03-19-19.pdf | ||
| 36C26223Q1005_1 Back Up Generator Instal Solicitation.pdf | ||
| 36C26223Q1005.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMPRESSOR
ROOM
PROCESSING
TELECOM
ROOM
STORAGE
STORAGE
111 112
WOMEN'S
MEN'S
PROCESSING JAN
OPEN
WAREHOUSE
CAGE
VESTIBULE
100OFFICE
OFFICE
OFFICE
OFFICE / ADMIN
WALK-IN
COOLER
LOADING
DOCK
VESTIBULE
MEZZANINE
ABOVE
"MDP"
ATS
PANEL "LP2"
EDP
PANEL "LP1" (RE-FEED TO "EDP")
TO SEG
PANEL "EP1" (RE-FEED TO "EDP")
PANEL "EP2" (RE-FEED TO "EDP")
PANEL "EP3"
13 14 14
6 6
EP-101
1/8" = 1'-0"
POWER PLAN
POWER
PLAN
SHEET KEYNOTES
1. NEW 4-500KCMIL THHN/THWN (CU) + 1#1/0 THHN/THWN (CU) GR IN 3.5"C. ROUTE
OVER HEAD THROUGH THE BUILDING FROM THE EXISTING MAIN DISTRIBUTION
PANELBOARD TO THE NEW 400A ATS. COORDINATE ROUTING WITH EXISTING
FIELD CONDITIONS.
2. NEW 400A AUTOMATIC TRANSFER SWITCH (ATS), ASCO 300 SERIES IN NEMA 1
ENCLOSURE. INSTALL IN CONVENIENT AND ACCESSIBLE LOCATION V VERIFY WITH
EXISTING FIELD CONDITIONS.
3. NEW TWO (2) 3"C EACH WITH 4-250KCMIL THHN/THWN (AL) + 1#2/0 THHN/THWN (AL)
GR, MINIMUM 24" BELOW FINISH GRADE FROM THE ATS TO THE SEG. REFER TO
THE SITE PLAN THIS SHEET FOR ROUTING.
4. NEW 4-600KCMILL THHN/THWN (CU) + 1#1/0 THHN/THWN (CU) GR IN 4"C FROM THE
ATS TO NEW PANEL "EDP".
5. NEW PANEL "EDP" RATED 120/208V, 3PH, 4W , 400A MLO SURFACE MOUNT, NEMA 1
CONSTRUCTION. REFER TO THE PANEL SCHEDULE THIS SHEET.
6. NEW PANEL FEEDER, 4#3/0 THHN/THWN (CU) + 1#6 THHN/THWN (CU) GR IN 2"C.
7. EXISTING PANEL. DISCONNECT AND REMOVE EXISTING PANEL FEEDER FROM
"MDP" AND PROVIDE NEW PANEL TO NEW PANEL "EDP" AS INDICATED.
8. EXISTING PANEL REMAINS. NO WORK. SHOWN FOR REFERENCE ONLY.
9. NEW 1.5"C WITH 3#1 THHN/THWN (CU) + 1#6 THHN/THWN (CU) GR TO PANEL "E3"
FOR 120V BRANCH CIRCUITS FOR THE SEG BATTERY CHARGER AND SEG BLOCK
HEATER.
10. NEW 1"C WITH CONTROL WIRING AS REQUIRED FROM THE SEG TO THE ATS FOR
START CIRCUIT.
11. EXISTING MAIN DISTRIBUTION PANELBOARD, RATED 277/480V, 3PH, 4W, 1000A MAIN
CIRCUIT BREAKER. PROVIDE NEW 400A/3P CIRCUIT BREAKER IN SPACE FOR NEW
PANEL "EDP" AND MATCH THE EXISTING PANELBOARD MANUFACTURER, SIEMENS.
PROVIDE NEW NAMEPLATE FOR "PANEL EDP".
12. NOT USED.
13. EXISTING PANEL FEEDER REMAINS.
14. REMOVE EXISTING PANEL FEEDER. ABANDON CONDUIT BELOW GRADE.
ISSUE:
CAD DWG FILE:
CHECKED BY:
DRAWN BY:
SHEET TITLE:
PROJECT NO:
MARK DESCRIPTIONDATE
CONSULTANT
DATE:
CONSTRUCTION DOCUMENTS
03-21-17
ACE
FJT
17-050
EP-101.DWG
S :\1
A C
E E
\2
P ro je ct s\
-1
V
A P ha rm ac y
S E
G \E le ct
\E P
-1
.D W
G
120 Aliso Drive, SE Albuquerque, New Mexico 87108
Phone 505.842.5787 Facsimile 505.842.5797
A C ENGINEERING
ENTERPRISES, LLC
ELECTRONIC MEDIA COPY:
Electronic media is subject to damage or alteration. AC Engineering Enterprises, LLC.
neither warrants nor accepts responsibility for the condition of the electronic media or correctness on data stored thereon.
VA PHARMACY
SEG
01/23/19
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text W
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text K
AutoCAD SHX Text C
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text T
| Sheets and Views |
| EP-101 |
File details come from the government source that posted it. Updated .