S-614-14 (RRFB DETAIL).pdf
PDF 2 MB Posted
- Attached to
- Rapid Flashing Beacons State and local contract opportunity
- Solicitation number
- 2025-22Q
- Issued by
- Garfield County, Colorado
About this file
This is a technical drawing and detail specification document for Rectangular Rapid Flashing Beacons (RRFB) prepared by the Colorado Department of Transportation (CDOT) Traffic & Safety Engineering division. The document provides comprehensive engineering specifications for a pedestrian crossing safety system, including detailed schematics for mounting configurations, electrical service details, signal head configurations, solar panel installations, and foundation requirements. The drawings include uni-directional and bi-directional beacon setups with specific sign placements (such as W11-2, W16-7PR/PL), pedestrian pushbutton assemblies, and mounting instructions for 4" standard steel pipe supports.
The technical specifications outline critical design parameters including wind load considerations, soil density assumptions (110 lb/cu.ft), soil cohesion (750 lb/sq.ft), and footing design based on 100 MPH wind speeds. The document provides installation guidance for electrical services, grounding methods, conduit specifications, and foundation details. Alternative installation methods are illustrated, with provisions for various site conditions such as different soil types, groundwater tables, and potential geological challenges. The drawings are designed to ensure consistent, safe, and standardized installation of pedestrian crossing warning systems across Colorado's roadways.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| 2025-22Q Rapid Flashing Beacons.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PIPE POST ENTERS
SLIPFITTER COLLAR
APPROXIMATELY 4"
N ~ 0 N
Lt') N
X 0
N i------ TYPICAL SIGNAL HEAD
12" YELLOW LENS
t 12"
PANEL ATTACHMENT
(SEE DETAILS)
4" STD. STEEL PIPE
WT. 10.79 LBS./FT.
BREAK-AWAY ASSEMBLY
(SEE NOTE 5 AND DETAIL ON SHEET 2)
ATTACH GROUNDING
CABLE BY LUG
• r
~ (SEE DETAIL, SHEET 2)
~~n~~~
I I I I
~-~--~--+-- LJ
J'/411 MINIMUM DIA. RIGID
UNDERGROUND CONDUIT
24" MINIMUM BELOW
GROUND LEVEL (OPTIONAL)
POST ANCHOR
(SEE DETAIL, SHEET 2)
f l--18" ----I
TYPICAL CONCRETE
FOOTING DETAIL
(SEE NOTE 3)
TABLE OF DIMENSIONS FOR PANELS NOT ILLUSTRATED
DIMENSIONS (IN.) LENS BACKING DESCRIPTION TYPE ZEES X y z
36" DIAMETER CIRCLE PANEL ( • ) 8 20 8 12" YELLOW 20"
48" DIAMETER CIRCLE PANEL ( • ) toY2 27 toY2 12" YELLOW 20"
36" PENTAGON PANEL ( • ) 9 20 9 12" YELLOW 20"
48" PENT AGDN PANEL ( • ) 12 25% 9 12" YELLOW 20"
48" OCTAGON PANEL ( • ) 12 24 12 12" RED 20"
24" X 48" RECTANGLE PANEL ( • ) 12 24 12 12" YELLOW 20"
TYPICAL ELEVATION FACING TRAFFIC
Com uter File Information Sheet Revisions Creation Date: 07 /04 / 12 Date: Corrvnenta
_ cr_e_a_te_d_ By_:_B_u_tt_a_ K_E_N __________ .... ~
1--La_s_t _M_o_d_if i_c_at_io_n_Da_t_e_: _07....a/_3_1'-/ 1_9 _______ -I ~ Last Modified By : EBUTT A (=:) ------------------ ,..-., CAD Ver.: MicroStation V8 Scale: Not to Scale Units: English \-1
DOOR
HINGE
LL
D w Cl w w _J
Cl w _J w "" I-
ST AND ARD 12" VISOR
DOOR ---~~~-=-.-1r
FASTENER
TYPICAL SIGNAL HEAD
12" YELLOW DR RED LENS
WITH 150 WATT LAMP
DR !TE AMBER LED
ATTACH SIGNAL HEAD
WITH !V2" CLOSE NIPPLE _J
AND PIPE LOCKNUT l;::!=::::::::~::;r
PLUG UNUSED OPENINGS
SLIPFITTER COLLAR FDR 4"
STD. STEEL PIPE (4Y2" O.D.)
%" SET SCREWS
TYPICAL SIGNAL HEAD - 12 INCH LENS
-----BACKING ZEE ----
4" I• . * • ! • * • I • * • ! • * • ! 4"
* = 611 INCREMENTS
(DRILL %" HOLES FOR NUMBER
BY ZEE LENGTH MINUS 811 )
REQ'D. UNDER EACH U-CLAMP
SIGN PANEL U-CLAMP
TYPICAL PANEL ATTACHMENT DETAILS
Al
LATERAL PLACEMENT ( 11 A11 )
NORMAL LATERAL PLACEMENT "A" FOR WARNING SIGNS
IS 12' PLUS CURB DR SHOULDER WIDTH.
NORMAL LATERAL PLACEMENT "A" FOR REGULATORY
SIGNS IS 6' PLUS CURB DR SHOULDER WIDTH,
DR IF NONE 12' FROM EDGE OF PAVEMENT.
2' SHALL BE CONSIDERED MINIMUM EXCEPT
THAT IN URBAN AREAS 1' FROM THE CURB FACE
IS PERMISSIBLE WHERE SIDEWALK WIDTH IS LIMITED
DR WHERE EXISTING POLES ARE CLOSE TD THE CURB.
REFER TD COLORADO STANDARD PLAN S-614-1 FOR
VERTICAL PLACEMENT REQUIREMENTS.
TYPICAL SIGN PLACEMENT
GENERAL NOTES
I. ALL SIGN PANELS USED ON FLASHING BEACONS ARE CLASS II AND SHALL BE
FABRICATED IN ACCORDANCE WITH:
A. PANELS SHALL BE SINGLE SHEET ALUMINUM 0.100 MINIMUM THICKNESS.
B. BACKING ZEES ARE 3 IN. X 211#16 IN. 2.33 LBS. PER FT. ALUMINUM.
C. ALL SIGNS SHALL BE FABRICATED USING RETRDREFLECTIVE SHEETING CONFORMING
TD ASTM D4956. THE TYPE SHALL BE DESCRIBED IN THE STANDARD
SPECIFICATIONS AND/DR AS SHOWN ON THE PLANS.
D. BOLTS, U-CLAMPS, NUTS AND METAL WASHERS SHALL BE GALVANIZED
DR CADMIUM PLATED.
2. INSTALLATION DESIGN CONFORMS WITH AASHTD "STANDARD SPECIFICATIONS FDR
STRUCTURAL SUPPORTS FDR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS"
ANO SHALL BE FABRICATED IN ACCORDANCE WITH:
A. STEEL PIPE, PDST ANCHOR PLATES AND BREAK-AWAY PLATES SHALL
CONFORM TD AASHTD M270 (ASTM A709) GRADE 36.
B. HIGH STRENGTH BDL TS, NUTS AND WASHERS SHALL CONFORM TD ASTM-A325
AND SHALL BE GALVANIZED DR CADMIUM PLATED.
C. HOLES SHALL BE DRILLED AND CUTS SHALL PREFERABLY BE SAW CUTS;
HOWEVER,FLAME CUTTING WILL BE PERMITTED PROVIDED ALL EDGES ARE
GROUND. METAL SHALL NOT PROJECT BEYOND THE PLANE OF THE PLATE FACE
ON BREAK-AWAY PLATES.
D. ALL WELDING IS TD BE CONTINUOUS AND IN ACCORDANCE WITH CURRENT
AWS SPECIFICATIONS.
E. A "KEEPER PLATE" OF THIN (28 GAGE) GALVANIZED SHEET METAL,
FABRICATED TD MATCH BREAK-AWAY PLATE DIMENSIONS BUT WITH
HOLES RATHER THAN SLDTS, SHALL BE USED TD RESTRAIN BOLT LOOSENING
DUE TD WIND VIBRATION.
• F. PIPE LENGTH VARIES WITH VERTICAL PLACEMENT, MINIMUM GROUND
CLEARANCE (7 FT. ) AND THE SIGN PANEL REQUIRED. IT WILL BE AS
SHOWN ON THE PLANS, DR AS DETERMINED BY CROSS-SECTION, DR AS
DIRECTED BY THE ENGINEER FOR EACH LOCATION (MAXIMUM LENGTH
IS APPROXIMATELY 20 FT.-10 IN. AND MINIMUM LENGTH IS APPROXIMATELY
15 FT.-4 IN. IF LENGTH IS NOT SPECIFIED SUPPLY MAXIMUM - MAY REQUIRE
FIELD CUT TD CONFORM TD TYPICAL SIGN PLACEMENT DETAILS).
3. CONCRETE FOOTINGS FDR FLASHING BEACON INSTALLATIONS SHALL CONFORM TD
"DRILLED CAISSONS" AND "STRUCTURAL CONCRETE" (CLASS "BZ").
4. ALL ELECTRICAL MATERIALS AND WORKMANSHIP SHALL CONFORM TD THE
LATEST REQUIREMENTS OF THE NEC,NEMA, UL OR EIA WHEREVER
APPLICABLE; THE COLORADO PUC AND ANY LOCAL CODES OR
ORDINANCES WHICH MAY APPLY; AND THE FOLLOWING:
A. THE CONTRACTOR IS TD PROVIDE ALL NECESSARY WIRING WITHIN THE
BEACON AND FROM THERE TD THE POWER SOURCE PROVIDED BY THE
UTILITY COMPANY. THE UTILITY COMPANY WILL MAKE THE
CONNECTION WITH THE CONTRACTOR'S WIRING.
B. THE ELECTRICAL SERVICE BETWEEN THE POWER SOURCE AND THE
FLASHING BEACON SHALL BE UNDERGROUND UNLESS AN AERIAL DROP
IS AUTHORIZED BY THE ENGINEER. ALL WIRING EXCLUDING THE AERIAL
DROP WIRE SHALL BE IN CONDUIT.
C. THE "FLASHER" SHALL BE HOUSED IN A SUIT ABLE ENCLOSURE ON THE
UTILITY POLE AT THE POWER SOURCE UNLESS THE ENGINEER DIRECTS
THAT THE ENCLOSURE BE MOUNTED ON THE BEACON PIPE OR THAT
THE DEVICE MAY BE CONTAINED WITHIN THE SIGNAL HEAD ITSELF.
D. A SUITABLE ENCLOSURE FOR THE FLASHER SHALL BE IN ACCORDANCE
WITH "A RAIN TIGHT JUNCTION BOX OR CAN, APPROXIMATELY 8 IN. X 8
N. X 4 IN., SURFACE MOUNT, WITH A FLANGED SCREW ATTACHED
COVER, AND FABRICATED FROM NOT LESS THAN 16 GAGE GALVANIZED
STEEL".
E. A BUil T -IN RADIO INTERFERENCE SUPPRESSION DEVICE AND A
PHOTOCELL SENSOR TYPE SIGNAL LAMP DIMMER SHALL BE PROVIDED
FOR EACH FLASHING BEACON.
F. BEACONS SHALL FLASH AT A RATE OF NOT LESS THAN 50 AND NOT MORE
THAN 60 TIMES PER MINUTE.
5. BREAKAWAY BASE INST ALLATIDN SHALL BE USED FDR UNI-DIRECTIONAL
CONFIGURATION ONLY. PEDESTAL FOUNDATION (AS SHOWN ON SHEET 3).
MAY BE USED FOR BOTH UNI-DIRECTIONAL AND BI-DIRECTIONAL CONFIGURATIONS.
6. WHEN SPECIFIED IN THE PLANS, SOLAR POWERED SYSTEM MAY BE USED IN
PLACE OF AC POWER SYSTEM SHOWN ON THIS SHEET.
7. FOR ADVANCE PLACEMENT OF WARNING SIGNS SEE MUTCD SECTION 2C.05 AND
TABLE 2C-4.
Colorado Department of Transportation
8'1 2829 W. Howard Pl.
Denver, CO 80204 Phone: 303- 757- 94 36
FAX: 303- 757- 9219
FLASHING BEACON AND
SIGN INSTALLATIONS
STANDARD PLAN NO.
S-614-14
Traffic 8c Safety Engineering MKB Issued By: Traffic & Safety Engineering Branch July 31, 2019. Pr o ject Sheet Number :
Standard Sheet No. 1 of 4
A
%11 0 X 27'4" H.S. BOLT
WITH HEX HEAD AND
THREE FLAT WASHERS
SECTION A-A
BREAK-AWAY ASSEMBLY BOLTING PROCEDURE
2Y2" DIA. HOLE IN
CENTER OF PLATES
I. ASSEMBLE POST TD FOOTING WITH BOLTS- ONE FLAT WASHER ON EACH BOLT TOP AND BDTTDM,AND ONE FLAT WASHER AND THE KEEPER PLATE BETWEEN THE BREAK-AWAY PLATES. USE BRASS SHIMS TO PLUMB THE POST.
2. TIGHTEN ALL BOLTS TO MAXIMUM POSSIBLE WITH A 12 TO 15 INCH PIPE WRENCH TO BED WASHERS AND SHIMS TO CLEAN BOLT THREADS, THEN LOOSEN EACH BOLT IN TURN AND RETIGHTEN IN A SYSTEMATIC ORDER TO 450
INCH-POUNDS TORQUE.
3. BURR THREADS AT JUNCTION WITH NUT USING A CENTER PUNCH TO PREVENT NUT LOOSENING.
SECTION B-B (PLATE DETAIL)
SHIM DETAI L
FURNISH TWO (2) .012 IN.± THICK
AND TWO (2) .032 IN.± THICK SHIMS.
SHIMS SHALL BE FABRICATED FROM
BRASS SHIMS STOCK DR STRIP
CONFORMING TD ASTM-B 36.
POLE CLAMP
PIPE CLAMP
ASSEMBLY
11/4" CONDUIT
NIPPLE
LOCKNUT
BEACON
PIPE
BUSHING ENCLOSURE
(NOTE: WELD VARIES WITH CONDUIT OR
NIPPLE WALL THICKNESS.)
TYPICAL PIPE
ATTACHMENTS
TYPICAL BREAK-AWAY ASSEMBLY DETAILS
4" X 8" X 1/4 11
METAL PLATE
FLANGE SECTION A-A
POST ANCHOR DETAILS
Com uter File Information Creation Date: 07 /04 / 12
1--Cr_e_a_te_d ___ By ... :_B_u_tt_a_K.;.;E;.;.N __________ -1 (=:)
Last Modification Date: (=:) ------------------ ,---., Last Modified By: \.__./
CAD Ver.: MicroStation VB Scale: Not to Scale Units: English (=:)
VIEW AT POWER SOURCE
AERIAL DROP
SERVICE
SERVICE POLE
VIEWS AT ENCLOSURES
POWER SUPPLY
IIIL±....._~ METER ~~---.
CIRCUIT
BREAKER
• FLASHER
ENCLOSURE
UNDERGROUND~----~•
SERVICE
NOTES
LOCATION AND CONFIGURATION OF ELECTRICAL
EQUIPMENT IS DIAGRAMATIC ONLY (USE ANY
METHOD COMPLYING WITH THE GENERAL NOTES).
• EXISTING GROUND AT SERVICE POLE;
OTHERWISE PULL THRU CONDUIT DR
ATTACH TD CONDUIT AND TAP OFF
VIEW AT BEACON
UNDERGROUND. ALTERNATE SIGN
• DRILL AND TAP PIPE FOR 1/. 11 ROUND FLASHER PANEL
ROUND HEAD BRASS SCREW,Y/ LONG LOCAT~ONS
FDR GROUND LUG.
• PROVIDE WEEP HOLE WITH AERIAL DROP SERVICE BEACON
# BEDDING MATERIAL FDR CONDUIT SHALL BE PLACED PIPE
IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE.
UNDERGROUND CONNECTI ON
Jl/4" MIN. DIA.
UNDERGROUND
RIGID CONDUIT
LOCKNUT
DR WELD
NIPPLE
DRILL AND TAP FDR
GROUND LUG 1/4" X 1"4 11
BRASS SCREW
UNDERGROUND VIEWS AT POWER SOURCE TRENCHI NG DETAI L
--j 6"f--
SERVICE POLE
TYPICAL ALTERNATE GROUNDING METHODS
Sheet Revisions Date: Conmenta
7'4" GRAVEL FOOTING
CONDUIT
IN FOOTING
MINIMUM DEPTH
24"UNDERGROUND
30"UNDER ROADWAY
TYPICAL ALTERNATE GROUNDING METHODS
TYPICAL ELECTRICAL SERVICE DETAIL
Colorado Department of Transportation
SQ 2829 W. Howard Pl.
Denver, CO 80204 Phone: 303- 757 - 9436
FAX: 303-757- 9219
Traffic & Safety Engineering MKB
FLASHING BEACON AND
SIGN INSTALLATIONS
Issued By: Traffic & Safety Engineering Branch July 31, 2019.
STANDARD PLAN NO.
S-614-14
Pro j ect Sheet Number :
Standard Sheet No. 2 of 4
SOLAR PANEL
(AC POWERED SYSTEM MAY
ALSO BE USED WHEN SPECIFIED)
~ SOLAR PANEL
SIGN Wll-2
(SEE NOTE 10)
RECTANGULAR
RAPID-FLASHING
BEACON - APPROX.
24" X 411 X 1-1/2"
(SEE NOTE 7)
SIGN W16-7PR
DR W16-7PL
(30" x 18" OPTIONAL)
~ ---- 4" STD. STEEL PIPE
WT.10.79 LBS./FT.
-----SIGN Wll-5Dl • 12" X 1211
-----PEDESTRIAN PUSHBUTTON
AND SIGN ASSEMBLY
(SEE NOTE 3)
MATCHLINE --------- - -- -- -
FRONT ELEVATIO N VIEW
PEDESTAL FOUNDATION (SEE NOTE 11 AND
DETAIL ON SHEET 4
SIGN Wll-2
RECTANGULAR
RAPID-FLASHING
BEACON ·
SIDE OF POLE
MOUNT SHOWN
SIGN Wl6-7PR
DR W16-7PL
(AC POWERED SYSTEM MAY
ALSO BE USED WHEN SPECIFIED)
CONTROL CABINET
ENCLOSURE
(SEE NOTE 5)
MOUNTING BRACKET
AND STEEL STRAP (TYP.)
'----- WINDBEAM (TYP.)
PEDESTRIAN PUSHBUTTON
AND SIGN ASSEMBLY
(SEE NOTE 3)
_ MATCHLINE__ 1 __ ____ _
SIDE ELEV ATION VIEW
UNI- DIRECTIONAL CONFIGURATION
DETAILS
SIGN Wll-2
RECTANGULAR
RAPID-FLASHING
BEACON -
SIDE OF POLE
MOUNT SHOWN
SIGN W16-7PR
DR Wl6-7PL
PEDESTRIAN PUSHBUTTON
AND SIGN ASSEMBLY
(SEE NOTE 3)
____ MATCHLINE __ _
SIDE ELEVATION VIEW
BI - DIRECTIONAL CONFIGURATION
DETAILS
RECT AGULAR RAPID-FLASHING BEACON (RRFB)
SOLAR PANEL
(AC POWERED SYSTEM MAY
ALSO BE USED WHEN SPECIFIED)
CONTROL CABINET
ENCLOSURE
(SEE NOTE 5)
SIGN Wll-2
RECTANGULAR
RAPID-FLASHING
BEACON -
SIDE OF POLE
MOUNT SHOWN
SIGN Wl6-7PL OR Wl6-7PR
Com uter File Information Creation Date: 07 /31/19 Date:
Sheet Revisions Corrvnenta
Colorado Department of Transportation FLASHING BEACON AND
SIGN INSTALLATIONS
Creat ed By: EButta
Last Modi f ication Date:
Last Modified By:
CAD Ver.: MicroStation VB Scale: Not to Scale Units: English c::) 1-----+------------1 c::) 1-----+----------~ c::)
c::)
8'1 2829 W. Howard Pl.
Denver, CO 80204 Phone: 303- 757- 9436
FAX: 303- 757- 9219
Traffic 8c Safety Engineering MKB Issued By: Traffic & Safety Engineering Branch July 31, 2019.
GENERAL NOTES
I. THE RRFB SYSTEM SHALL ADHERE
TD ALL ASPECTS OF THE FEDERAL
HIGHWAY ADMINISTRATION, INTERIM
APPROVAL 21-RECT ANGULAR RAPID-FLASHING
BEACONS AT UNCONTROLLED MARKED
CROSSWALKS (FHWA IA-21).
2. AN RRFB SHALL ONLY BE USED TD
SUPPLEMENT A POST-MOUNTED Wll-2, SI-I, DR Wll-15 SIGN WITH 16-7P PLAQUE, LOCATED IMMEDIATELY ADJACENT TD AN
UNCONTROLLED MARKED CROSSWALK.
3. PEDESTRIAN PUSHBUTTON AND SIGN
ASSEMBLY MAY BE SEPARATE PARTS.
USE Rl0-25 (9" X 12") SIGN IN ACCORD
ANCE WITH 2009 MUTCD. SIGN MAY INCLUDE
INTEGRATED WARNING LIGHTS.
4. TERMINATE RRFB CONNECTIONS PER MANU
FACTURER'S RECOMMENDATION.
5. CONTROL CABINET ENCLOSURE SHALL
BE SIZED BY THE RRFB MANUFACTURER.
6. BEACON ASSEMBLY MAY BE MOUNTED ON
THE SIDE OF THE POLE AS SHOWN OR ON
THE TOP OF THE POLE IF SPECIFIED.
7. RRFB DISPLAYS SHALL BE LED TYPE MEETING
THE INTENSITY REQUIREMENTS OF SAE J595
FDR CLASS 1 YELLOW, BUT SHALL NOT EXCEED
1000 CANDELAS DURING DAYLIGHT AND 500
CANDELAS AFTER DARK.
8. SEE SHEET 1, 2 AND 4 FOR STANDARD
BASE AND FOUNDATIONS DETAILS.
9. WHEN SPECIFIED IN THE PLANS, AC POWER
SYSTEM (AS SHOWN ON SHEET 1) MAY BE USED
IN PLACE OF SOLAR POWERED SYSTEM SHOWN
ON THIS SHEET.
JO.FOR POSTED SPEEDS OF 35 MPH DR LOWER,
THE Wll-2 SIGNS SHALL BE 36" x 36". FOR
POSTED SPEEDS OF 40 MPH OR HIGHER, THE
Wll-2 SIGNS SHALL BE 48" x 48".
11. PEDESTAL FOUNDATION MAY BE USED
FDR BOTH UNI-DIRECTIONAL AND Bl-DIRECTIONAL
CONFIGURATIONS. BREAKAWAY BASE INSTALLATION
(AS SHOWN ON SHEET 1) SHALL BE USED FOR
UNI-DIRECTIONAL CONFIGURATION ONLY.
STANDARD PLAN NO.
S-614-14
Pr oject Sheet Number :
Standard Sheet No. 3 of 4
7"
6'-0" 0...
0 +l
2-#4 STIRRUPS 0
::c:
"' AT 611 ± AROUND ")
"* f- <C
ANCHOR BDL TS. ~
3"
1'-6"
ALTERNATE PEDESTAL BASE INSTALLATION
Com uter File Information Sheet Revisions Creation Date: 07 /04 /12 Date: Corrvnenta
_ cr_e_a_te_d_By_:_B_u_tt_a_K_E_N __________ ... ~
1--La_s_t _M_o_d_if i_c_at_io_n_Da_t_e_: -----------1 ~ Last Modified By : (=:) ------------------ ,,.-., CAD Ver.: MicroStation VB Scale: Not to Scale Units: English \-1
GENERAL NOTES
1. POLE AND PEDESTAL MUST BE DESIGNED TD MEET THE REQUIREMENTS OUTLINED IN THE "STANDARD SPECIFICATIONS FDR STRUCTURAL
SUPPORTS FDR HIGHWAY SIGNS LUMINAIRES AND TRAFFIC SIGNALS", PUBLISHED BY M SHTD, FDR A WIND VELOCITY OF 100 MPH.
THE CONTRACTOR SHALL SUBMIT TWO SETS OF WORKING DRAWINGS, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF COLORADO, IN ACCORDANCE WITH SECTION 105.02 OF THE ST AND ARD SPECIFICATIONS FDR ROAD AND BRIDGE CONSTRUCTION.
DESIGN DATA
THE DESIGNS HEREIN ASSUME THAT FLASHING BEACONS ARE INSTALLED WITHIN
THE ROADWAY PRISM WITH THE FOLLOWING SOIL PARAMETERS:
SOIL DENSITY v = 110 LB./CU.FT.
SOIL COHESION = 750 LB./SQ.FT. FDR MEDIUM STIFF COHESIVE SOIL
SOIL 0 ANGLE = 30 DEG. FDR MEDIUM DENSE CDHESIDNLESS SOIL
SF= 3.0 FDR FLEXURAL RESISTANCE
CONT ACT THE ENGINEER IF THE FLASHING BEACON WILL NOT BE INSTALLED WITHIN
THE ROADWAY PRISM DR IF ANY OF THE FOLLOWING SOIL CONDITIONS ARE ENCOUNTERED DURING DRILLING:
/0 THE SOIL HAS A HIGH ORGANIC CONTENT OR CONSISTS OF
SATURATED SILT AND CLAY.
B) THE SITE WON'T SUPPORT THE WEIGHT OF THE DRILLING RIG.
C) THE FOUNDATION SOILS ARE NOT HDMDGENDUS.
D) FIRM BEDROCK IS ENCOUNTERED.
E) A HIGH GROUNDWATER TABLE IS ENCOUNTERED.
F) LARGE BOULDERS ARE ENCOUNTERED.
FOOTING DESIGN IS BASED ON 100 MPH WIND LOAD ON A 48 IN. X 48 IN. DIAMOND SIGN PANEL MOUNTED 9 FT.ABOVE THE GROUND, WITH A 24 IN. X 24 IN. RECTANGULAR PLAQUE UNDERNEATH AND A FLASHING BEACON 12 IN. ABOVE. IF A SIGN CONFIGURATION IS PROPOSED THAT EXCEEDS
THESE DIMENSIONS, THE FOOTING DESIGN MUST BE ENGINEERED AND SIGNED AND SEALED BY
A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF COLORADO.
FOOTING NOTES
CD HEX NUTS
@ SQUARE NUTS
~ HAND HOLE SHALL BE PROVIDED.
IA\ 4 IN. MIN. NON-SHRINKABLE
~ GROUT OVER ROUGH FOUNDATION
@ SCHEDULE 80 PVC (24 IN. MIN. DEPTH,
30 IN. MIN. DEPTH UNDER ROADWAY)
CONDUIT STUB FROM PULL BOX TD POLE
SHALL BE 2" MIN. DIAMETER.
(j)
INST ALL ANCHOR BDL TS (FURNISHED WITH
POLE) PER MANUFACTURER'S TEMPLATE PRINT
(FURNISHED WITH ORDER)
MINIMUM OVERLAP OF 12 IN.
l-Y2 IN. CLEARANCE FDR HOOPS
ST AND ARD PULL BOX .... TYPE m
CAISSON DESIGNS REQUIRE THAT THE CAISSON
BE FOUNDED IN COMPACT SAND, CLAY OR
SANDY CLAY. IF, BY VISUAL INSPECTION OF
THE HOLE, OTHER MATERIAL IS PRESENT, THE
CAISSON DESIGN SHALL BE MODIFIED AS
DETERMINED BY THE ENGINEER.
Colorado Department of Transportation FLASHING BEACON AND
SIGN INSTALLATIONS
STANDARD PLAN NO.
8 '1 2829 W. Howard Pl.
Denver, CO 80204 Phone:303- 757- 94 36
FAX: 303- 757-9219
Traffic 8c Safety Engineering MKB
S-614-14
I ssued By: Traffic & Safety Engineering Branch July 31, 2019. Pr o ject Sheet Number :
Standard Sheet No. 4 of 4
| S-614-14_1of4 |
| S-614-14_2of4 |
| S-614-14_3of4 |
| S-614-14_4of4 |
File details come from the government source that posted it. Updated .