The document is a set of technology infrastructure design drawings for the Macomb County Central Intake & Assessment Center and Jail Renovations project, prepared by Metro Technology Services for the Macomb County Office of the Sheriff. The drawings detail a comprehensive technology infrastructure upgrade, specifically focusing on structured cabling and communication equipment room fittings across multiple building levels, including basement, ground, second, third, fourth, and penthouse levels. The technical bid package (25-T01) is dated June 12, 2025, and covers the installation of network infrastructure, security electronics, access control systems, video management systems, and associated technical equipment throughout the facility located at 43565 Elizabeth Road in Mount Clemens, Michigan.
The drawings provide extensive technical specifications for technology infrastructure, including detailed floor plans showing precise locations for data drops, wireless access points, surveillance cameras, intercom systems, card readers, and other network and security devices. The project appears to be comprehensively planned, with specific notes about electrical requirements, conduit installations, cable routing, and integration of various technological systems. The technology contractor will be responsible for furnishing and installing structured cabling, including backbone fiber optic cabling and horizontal cabling across all specified drawings, with devices and equipment to be provided by others. The technical specifications emphasize compliance with national, state, and local codes, and include detailed requirements for cable management, power supply, and system integration.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| RFP 31-25 CIAC - Technology Bid Package 25-T01 Structured Cabling _ Communication Equipment Room Fittings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T0.00
Owner
Project Name
Revisions
Drawn By
Checked By
Approved By
Sheet No.
Sheet Name
Project No.
KW
KW
KW
Issued
COVER SHEET
25-T01 / MC 31-25
Macomb County 1 South Main St.
Mount Clemens, MI 48043
Macomb County Central Intake & Assessment
Macomb County Sheriff's Office 43565 Elizabeth Rd.
Mount Clemens, MI 48043
Key Plan
Bidding - Construction 06.12.2025
59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com
Center / Jail Renovations
Index of Drawings
DWG# DRAWING TITLE
TECHNOLOGY DRAWINGS:
TS1.00
TECHNOLOGY FLOOR PLAN - LOWER LEVEL AREA 'A'T1.00A
TECHNOLOGY SITE PLAN
TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'A' T1.01A
TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'B'T1.01B
TECHNOLOGY FLOOR PLAN - 2ND FLOOR AREA 'A'T1.02A
T1.02B T1.03A T1.03B T1.04A T1.04B
T1.04MA
T1.04MB
T1.05A T1.05B
ENLARGED TECHNOLOGY PLANS AND DETAILST1.06
TECHNOLOGY FLOOR PLAN - MCJ LOWER LEVELT1.07
TECHNOLOGY FLOOR PLAN - MCJ GROUND LEVELT.1.08
TECHNOLOGY FLOOR PLAN - MCJ SECOND LEVELT.1.09
T-01
TECHNOLOGY FLOOR PLAN - 2ND FLOOR AREA 'B'
TECHNOLOGY FLOOR PLAN - 3RD FLOOR AREA 'A'
TECHNOLOGY FLOOR PLAN - 3RD FLOOR AREA 'B'
TECHNOLOGY FLOOR PLAN - 4TH FLOOR AREA 'A'
TECHNOLOGY FLOOR PLAN - 4TH FLOOR AREA 'B'
TECHNOLOGY FLOOR PLAN - 4TH FLOOR MEZZANINE AREA 'A'
TECHNOLOGY FLOOR PLAN - 4TH FLOOR MEZZANINE AREA 'B'
TECHNOLOGY FLOOR PLAN - PENTHOUSE AREA 'A'
TECHNOLOGY FLOOR PLAN - PENTHOUSE AREA 'B'
SECURITY ELECTRONICS DRAWINGS:
SECURITY ELECTRONICS - SYMBOL LEGENDSE000
SECURITY ELECTRONICS - SITE PLAN SE100
SE101
SE102
SE103
SE104
SE105
SE106
SE107
SE108
SE109
SE110
SE111
SE112
SE113
SE114
SE115
SE200
Tech Bid Package 25-T01
Location Map
Macomb County Central Intake & Assessment Center / Jail Renovations Macomb County Sheriff's Office 43565 Elizabeth Rd.
Mount Clemens, MI 48043
Structured Cabling & Communication Equipment Room Fittings Technology Bid Package 25-T01
Bid Number: 31-25 Date: June 12, 2025
T-03T-02
PROPOSAL NUMBER
SE201
SE300
SE301
SE302
SECURITY ELECTRONICS - SITE PLAN ENLARGED DETAILS
SECURITY ELECTRONICS - BASEMENT LEVEL - AREA A
SECURITY ELECTRONICS - GROUND LEVEL - AREA A
SECURITY ELECTRONICS - GROUND LEVEL - AREA B
SECURITY ELECTRONICS - SECOND LEVEL - AREA A
SECURITY ELECTRONICS - SECOND LEVEL - AREA B
SECURITY ELECTRONICS - THIRD LEVEL - AREA A
SECURITY ELECTRONICS - THIRD LEVEL - AREA B
SECURITY ELECTRONICS - FOURTH LEVEL - AREA A
SECURITY ELECTRONICS - FOURTH LEVEL - AREA B
SECURITY ELECTRONICS - FOURTH LEVEL MEZZANINE - AREA A
SECURITY ELECTRONICS - FOURTH LEVEL MEZZANINE - AREA B
SECURITY ELECTRONICS - MECH PENTHOUSE LEVEL - AREA A
SECURITY ELECTRONICS - MECH PENTHOUSE LEVEL - AREA B
SECURITY ELECTRONICS - ENLARGED DETAILS
SECURITY ELECTRONICS - INTERCONNECT
SECURITY ELECTRONICS - INTERCONNECT CONT.
SECURITY ELECTRONICS - TYPICAL EQUIPMENT ROOM
SECURITY ELECTRONICS - TYPICAL DOOR INSTALLATION
SECURITY ELECTRONICS - ONE LINE DIAGRAMS
E-012
E-010E-011 E-009
E-0
E-015
E-003E-002 E-004
E-017
E-018
E-027
E-028
ENTER
EXIT
ENTER
EXIT
STAFF PARKING LOT
SERVICE YARD
STAFF PARKING LOT
ENTER
EXIT
EXIT
E-023
E-022
E-019
E-020
ET
R
ET
R
ET
R
E-024
E-025
E-026
E-021
E-016
E-001
E-014
E-013 E-007
E-006
E-005
TECHNOLOGY SITE PLAN
SCALE: 1" = 20'-0"
N
TS1.00
1 1
TS1.00
Owner
Project Name
Revisions
Drawn By
Checked By
Approved By
Sheet No.
Sheet Name
Project No.
KW
KW
KW
Issued
TECHNOLOGY
SITE PLAN
25-T01 / MC 31-25
Macomb County 1 South Main St.
Mount Clemens, MI 48043
Macomb County Sheriff's Office 43565 Elizabeth Rd.
Mount Clemens, MI 48043
Key Plan
Bidding - Construction 06.12.2025
B A
CIAC BLDG
EXTG BLDG
59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com
GENERAL TECHNOLOGY NOTES:
1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS
AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.
2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES
AND REGULATIONS.
3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH
MANUFACTURER'S REGULATIONS.
4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND
FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL
DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER
NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE
CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE
CONSIDERED AS GROUNDS FOR AN EXTRA.
5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND
SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO
ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.
6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.
7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE
ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.
8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.
9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE
ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START
OF WORK.
10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,
ROOF, AND FIRE RATED WALLS.
11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS
THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.
12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR
SHEET.
13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN
LOCATIONS WITH CABLE TRAY.
14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A
MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE
BOX TO MEET ACOUSTICAL REQUIREMENTS.
15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE
SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS
CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.
16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS
REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY
PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.
17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY
OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.
18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL
INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING
AGENCY OF THE PERMIT.
19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR
THE SYSTEM THEY ARE ASSOCIATED WITH.
20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE
PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID
PACKAGE.
21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS
NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL
NOT EXCEED 40% FULL CAPACITY.
22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF
THIS PROJECT.
23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF
THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.
DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE
WRITTEN APPROVAL.
Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01
INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF (UNLESS NOTED OTHERWISE IN THE KEYNOTES
BELOW). ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING
INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)
SYMBOL DESCRIPTION
TECHNOLOGY FLOOR PLAN LEGEND:
X-000
ETR
INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO
REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.
X-000
TECHNOLOGY FLOOR PLAN KEYNOTES:
1 SURVEILLANCE CAMERA TO BE POLE-MOUNTED THIS LOCATION (BY OTHERS).
TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL ONE (1) COMPOSITE
CABLE (OPTICAL FIBER & COPPER CABLE - SIMILAR TO CORNING ACTIFI FIBER
CABLE, 2 FIBERS) FROM THE NEAREST MDF/IDF TO THIS LOCATION.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.).
SURVEILLANCE CAMERA TO BE SURFACE-MOUNTED ON UNDERSIDE OF
CANOPY THIS LOCATION.
SURVEILLANCE CAMERA TO BE PEDESTAL-MOUNTED THIS LOCATION (BY
OTHERS). TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL ONE (1)
COMPOSITE CABLE (OPTICAL FIBER & COPPER CABLE - SIMILAR TO CORNING
ACTIFI FIBER CABLE, 2 FIBERS) FROM THE NEAREST MDF/IDF TO THIS
LOCATION. ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING
INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.).
L-0
L-008
L-010
L-006L-003
L-004
L-005
L-001
L-0
L-007
FIRE PUMP ROOM
PLUMBING/ WATER HEATER
ROOM
MDF
MECHANICAL
FRESH AIR INTAKE AREAWAY
CORRIDOR
EMER ELECELECTRICAL ROOM
ELEC SUBSTATION RM
STAIR 2
STAIR 3
ELEVATOR LOBBY
MECHANICAL
AREA AAREA B
AREA AAREA B
UP
UP
AP
GENERAL TECHNOLOGY NOTES:
1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS
AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.
2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES
AND REGULATIONS.
3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH
MANUFACTURER'S REGULATIONS.
4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND
FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL
DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER
NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE
CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE
CONSIDERED AS GROUNDS FOR AN EXTRA.
5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND
SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO
ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.
6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.
7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE
ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.
8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.
9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE
ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START
OF WORK.
10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,
ROOF, AND FIRE RATED WALLS.
11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS
THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.
12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR
SHEET.
13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN
LOCATIONS WITH CABLE TRAY.
14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A
MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE
BOX TO MEET ACOUSTICAL REQUIREMENTS.
15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE
SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS
CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.
16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS
REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY
PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.
17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY
OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.
18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL
INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING
AGENCY OF THE PERMIT.
19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR
THE SYSTEM THEY ARE ASSOCIATED WITH.
20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE
PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID
PACKAGE.
21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS
NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL
NOT EXCEED 40% FULL CAPACITY.
22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF
THIS PROJECT.
23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF
THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.
DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE
WRITTEN APPROVAL.
TECHNOLOGY FLOOR PLAN - LOWER LEVEL AREA 'A'
SCALE: 1/8" = 1'-0"
N
T1.00A
2 2 2 2
T1.06
T1.00A
Owner
Project Name
Revisions
Drawn By
Checked By
Approved By
Sheet No.
Sheet Name
Project No.
KW
KW
KW
Issued
TECHNOLOGY
FLOOR PLAN -
LOWER LEVEL
AREA 'A'
25-T01 / MC 31-25
Macomb County 1 South Main St.
Mount Clemens, MI 48043
Macomb County Sheriff's Office 43565 Elizabeth Rd.
Mount Clemens, MI 48043
Key Plan
Bidding - Construction 06.12.2025
B A
CIAC BLDG
EXTG BLDG
59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com
Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01
LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN
FUTURE TECHNOLOGY BID PACKAGE.
1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC
CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION
271300.
TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE
FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT
LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.
LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE
FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO
SPECIFICATION SECTION 271100.
TECHNOLOGY FLOOR PLAN KEYNOTES:
"X"
INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY
CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"
DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR
TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,
JUNCTION BOXES, ETC.)
INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR
BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A
TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL
CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.)
"X"
INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
AP
SYMBOL DESCRIPTION
TECHNOLOGY FLOOR PLAN LEGEND:
INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
X-000
ETR
INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO
REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.
X-000
"X"
INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT
(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND
INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING
INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)
TV
INDICATES LOCATION OF NEW EXTERNAL MICROPHONE TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. NO WORK REQUIRED IN THIS BID PACKAGE.M
LOCATION OF VIDEO VISITATION UNIT (BY OTHERS). ELECTRICAL
CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,
JUNCTION BOXES, ETC.).
VCCP
ZC+M
ZC+S
ALT#1
ALT#1
ALT#1
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER CONTROL
PANEL LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL TWO (2) DATA DROPS THIS LOCATION. VERIFY EXACT
LOCATION PRIOR TO INSTALLATION.
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ MAIN
MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE VCCP
IN THE LOCAL MDF/IDF. TECHNOLOGY CONTRACTOR SHALL
FURNISH AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+M
LOCATION TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE
RUN FOR BIDDING PURPOSES).
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ SUB
MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
NEAREST ZC+M. TECHNOLOGY CONTRACTOR SHALL FURNISH
AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+S LOCATION
TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE RUN FOR
BIDDING PURPOSES).
8 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL AN ELEVATOR DEVICE
JUNCTION BOX FOR INTERFACE OF ELEVATOR DEVICES TO BE LOCATED
WITHIN THE ELEVATOR CABS. REFER TO SPECIFICATION SECTION 271500.
2 2
2 2
2 2 2 2
2 (COPIER)
2 2
2 2
2 2
(COPIER)
2 2
2 2
2 2
3 3 3
(COPIER)
G-062
G-057
G-059
G-058
G-061
G-063
G-085
G-083G-080
G-086
G-084
G-104 G-105
G-107
G-106
G-113
G-081
G-116
G-117
G-066
G-064
G-06 5 G-068
G-06
G-087
G-088
G-089 G-115G-114
G-118
G-126
G-075
G-074
G-072
TV
TV
G-079
G-077
G-076
G-073
G-103
G-094
G-096
2-TV
G-127
G-125 G-097
G-098
G-128
G-119
G-120
G-122
G-121
G-123
AP
AP
AP
AP
AP
AP
AP AP
AP
AP
AP AP
AP
AP
AP
AP
AP
AP
AP
(COPIER)
G-060
G-039
TV
AREA AAREA B
AREA AAREA B
PROPERTY STORAGE ROOM
INTERVIEW
ROOM
LT. / SGT.'S OFFICE
TETHERING VENDOR
FINANCE
KIOSK
TRASH
ALCOVE
JANITOR
CLOSET
CLINIC
PEDESTRIAN
SALLYPORT
OPEN WAITING - CLINIC
SECURE
WAITING
SECURE
WAITING
RECEPTION AND NURSING
STATION
EXAMINATION
ROOM -
GENERAL
DIALYSIS
SUITE
SUPPORT EXAMINATION
ROOM-
TRAUMA/ORTHO
SPECIALIZED
TREATMENT
EXAMINATION
ROOM- MINOR
PROCEDURES
EXAM PREP
AND
PHLEBOTOMY
ALCOVE
DENTAL EXAM ROOM
DENTAL
LAB/WORKROOM
AIR
COMPRESSOR
CLOSET
DOCTOR/
MEDICAL
DIRECTOR
OFFICE
MEDICAL
SUPPLY ROOM
MEDICATION STORAGE
MEDICAL
EQUIPMENT
STORAGE
CHARTING AREA
CLEAN UTILITY DIRTY UTILITY
ICE MAKER&
NOURISHMENT
PANTRY
Water Cooler
RESTROOM -
INMATE
RESTROOM -
STAFF
DIALYSIS
SPACE
EXAMINATION
ROOM -
GENERAL
EXAMINATION
ROOM -
GENERAL
EXAMINATION
ROOM -
GENERAL
INTERVIEW ROOM
EXTERIOR COURTYARD
JAIL
CLOTHING
STORAGE
TRASH
ALCOVE
OPEN
WAITING-
RELEASE
RELEASE PROPERTY STAGING
RELEASE
PROPERTY
TRANSACTION
WINDOW
RELEASE
CHANGING
HEALTH
SERVICES
ADMINISTRATOR
PSYCHIATRIST/MH
NURSE
PRACTITIONER
MH SERVICES
COORDINATOR
MEDICAL
RECORDS
STORAGE
SHARED OFFICE-MENTAL
HEALTH
DIRECTOR OF
NURSING
MEDICAL
RECORDS
CLERK
PRINTER/ COPIER ALCOVE
BREAKROOM - STAFF
CONFERENCE
ROOM
RECREATIONAL
LIBRARY BOOKS
ALCOVE
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
CLINIC SERVICES -
CIRCULATION
STAFF
ENTRANCE
PEDESTRIAN
SALLYPORT
CLEAN OPEN WAITING -
FULL BODY SEARCHFULL BODY SCANNER/ STATION
SECURE CORRIDOR
IDF-1
STAFF CIRCULATION
CLINIC OFFICER WORKSTATION
CORRIDOR
DEPUTY DIRECTOR
CLINICAL MANAGER
CLERICAL
SPECIALIST
BREAKROOM -
STAFF
INTERVIEW ROOM
WAITING AREA
CLERICAL
SPECIALIST
CLERICAL
SPECIALIST
SALLYPORT
PUBLIC LOBBY
CIRCULATION
ENTRY VESTIBULE
INTERVIEW ROOMS
INTERVIEW ROOMS
NONCONTACT
VISIT BOOTH -
ADA
NONCONTACT
VISIT BOOTH -
ADA
RELEASE
RESOURCE
INTERVIEW
ROOM
RELEASE
RESOURCE
INTERVIEW
ROOM
OFFICER
STATION
COMMUNITY CORRECTIONS
STAFF
SALLYPORT
LOCKERS
CIRCULATION
ADMINISTRATIVE
SERGEANT
STAFF
RESTROOM
OFFICE
SUPPLIES
SECURE FILE
STORAGE
OPERATIONS
LIEUTENANT
ADMINISTRATIVE
LIEUTENANT COMMUNITY
CORRECTIONS
DIRECTOR
EXECUTIVE
WORKROOM
+STORAGE
PRINTER/COPIER
WORK ALCOVE
JAIL OFFICE
PUBLIC
RESTROOM
PUBLIC
RESTROOM
ANTEROOM
PRINTER/
COPIER
WORK
ALCOVE
JANITOR
CLOSET
PUBLIC
NONCONTACT
VISIT BOOTH -
ADA
PUBLIC
NONCONTACT
VISIT BOOTH -
ADA
JAIL OFFICE
STATION
CONFERENCE ROOM
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
SECURE
PASSAGE
CONNECTION
RELEASE CORRIDOR
FIRE DEPT. CONTROL ROOM
BREAK ROOM
VIDEO
ARAIGNMENT
BOOTHS
STAFF LOCKER ROOM
JANITOR
CLOSET
RESTROOM -
INMATE
JAIL
ADMINISTRATOR
PRINTER/COPIER
WORK ALCOVE
RESTROOM-
INMATE
SECURE WAITING - TEL
SECURE WAITING - TEL
OFFICER
BOOTH
EXCHANGE/
CHECK OUT
UPS
EXERCISE ROOM
JAIL OFFICE
SUPERVISOR
RESTROOM -
STAFF
RESTROOM -
STAFF
RESTROOM -
STAFF
PRINTER/
COPIER
WORK
ALCOVE
RESTROOM -
STAFF
LACTATION
ROOM
RESTROOM -
STAFF
LACTATION
ROOM
CORRIDOR
JANITORS
CLOSET
ADA SHOWER/
CHANGING
CORRIDOR
ELEVATOR LOBBY
RESTROOM -
STAFF
CENTRAL CONTROL
ELECTRICAL ROOM
CONTROL
ROOM
SALLYPORT
ELECTRICAL ROOM
DECON ROOM
STAFF
ADMINISTRATION
SERVICE
WINDOW
RECORDS/BOND
TRANSACTION
WINDOW
WATER
COOLER
CORRIDOR
JAIL OFFICE
STATION
RESTROOM
INMATE
PRINTER
ALCOVE
JAIL OFFICE
STATION
DIRTY OPEN
WAITING -
FULL BODY
SEARCH
SALLYPORT
VESTIBULE
WAITING - VISITOR
RESTROOM -
STAFF
RESTROOM -
STAFF
JANITORS
CLOSET
COMMUNITY CORRECTIONS
STAFF
FIRE
SPRINKLERS
PIPE SHAFT
MECH SHAFT MECH SHAFT
CIRCULATION CIRCULATION
STORAGE
CLOSET
MEDICAL
STORAGE
STAFF TOILET
COMMUNITY CORRECTIONS
STAFF
OPEN WAITING - TELOFFICER
STATION
LOCKERS /
CORRIDOR
ROOF HATCH
ACCESS /
STORAGE
ADMIN.
ASSISTANT
JAIL OFFICE
STATION
G-
G-070 G-071
2 2 2 2 2 2 2
JAIL OFFICE
STATION
G-095
4 TV4 TV
G-111
G-112
2 2
2 2
G-108
G-124
G-102
G-101
G-100
G-099
G-082
G-093G-
G-
0 G-091
KEY WATCHER
SYSTEM
LOCATION
2 2
TV
TV
2-TV2
PH
TV
TV
TV
TV
G-13
DN
UPUP
UPUP
UP
VCCP
ALT#1
ZC+M
ALT#1
ZC+M
ALT#1
ZC+M
ALT#1
T1.06
TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'A'
SCALE: 1/8" = 1'-0"
N
T1.01A
T1.01A
Owner
Project Name
Revisions
Drawn By
Checked By
Approved By
Sheet No.
Sheet Name
Project No.
KW
KW
KW
Issued
TECHNOLOGY
FLOOR PLAN -
GROUND LEVEL
AREA 'A'
25-T01 / MC 31-25
Macomb County 1 South Main St.
Mount Clemens, MI 48043
Macomb County Sheriff's Office 43565 Elizabeth Rd.
Mount Clemens, MI 48043
Key Plan
Bidding - Construction 06.12.2025
B A
CIAC BLDG
EXTG BLDG
59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com
GENERAL TECHNOLOGY NOTES:
1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS
AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.
2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES
AND REGULATIONS.
3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH
MANUFACTURER'S REGULATIONS.
4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND
FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL
DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER
NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE
CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE
CONSIDERED AS GROUNDS FOR AN EXTRA.
5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND
SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO
ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.
6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.
7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE
ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.
8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.
9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE
ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START
OF WORK.
10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,
ROOF, AND FIRE RATED WALLS.
11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS
THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.
12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR
SHEET.
13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN
LOCATIONS WITH CABLE TRAY.
14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A
MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE
BOX TO MEET ACOUSTICAL REQUIREMENTS.
15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE
SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS
CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.
16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS
REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY
PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.
17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY
OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.
18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL
INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING
AGENCY OF THE PERMIT.
19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR
THE SYSTEM THEY ARE ASSOCIATED WITH.
20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE
PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID
PACKAGE.
21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS
NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL
NOT EXCEED 40% FULL CAPACITY.
22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF
THIS PROJECT.
23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF
THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.
DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE
WRITTEN APPROVAL.
Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01
LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN
FUTURE TECHNOLOGY BID PACKAGE.
1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC
CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION
271300.
TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE
FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT
LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.
LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE
FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO
SPECIFICATION SECTION 271100.
TECHNOLOGY FLOOR PLAN KEYNOTES:
"X"
INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY
CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"
DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR
TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,
JUNCTION BOXES, ETC.)
INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR
BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A
TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL
CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.)
"X"
INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
AP
SYMBOL DESCRIPTION
TECHNOLOGY FLOOR PLAN LEGEND:
INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
X-000
ETR
INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO
REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.
X-000
"X"
INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT
(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND
INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING
INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)
TV
INDICATES LOCATION OF NEW EXTERNAL MICROPHONE TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. NO WORK REQUIRED IN THIS BID PACKAGE.M
LOCATION OF VIDEO VISITATION UNIT (BY OTHERS). ELECTRICAL
CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,
JUNCTION BOXES, ETC.).
VCCP
ZC+M
ZC+S
ALT#1
ALT#1
ALT#1
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER CONTROL
PANEL LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL TWO (2) DATA DROPS THIS LOCATION. VERIFY EXACT
LOCATION PRIOR TO INSTALLATION.
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ MAIN
MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE VCCP
IN THE LOCAL MDF/IDF. TECHNOLOGY CONTRACTOR SHALL
FURNISH AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+M
LOCATION TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE
RUN FOR BIDDING PURPOSES).
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ SUB
MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
NEAREST ZC+M. TECHNOLOGY CONTRACTOR SHALL FURNISH
AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+S LOCATION
TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE RUN FOR
BIDDING PURPOSES).
2 2
8 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL AN ELEVATOR DEVICE
2 (COPIER)
2 2 2
2 2
2 2
2 2
(COPIER)
2 2
2 2
G-056
G-046 G-047
G-026
G-024
G-02
G-04
G-025
G-041
G-02
G-01
G-01
G-021
G-015
G-022
G-014
G-013
G-053
G-052
G-040
G-042
G-045
G-062
G-035 G-03
G-03
G-050
G-
G-
G-
G-
G-
G-
G-004
G-005
G-006
G-008
G-017 G-057G-033
G-059G-034
G-058
G-061
G-063
G-080
G-066
G-064
G-06 5 G-068
G-06
G-087
G-089
G-075
G-074
G-072
TV
TV
G-079
G-077
G-076
G-073
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
G-016
G-038
(COPIER)
G-060
G-039
G-02
G-049
G-048
TV
TV
M
M
AREA AAREA B
AREA AAREA B
PROPERTY STORAGE ROOM
CAROSEL
SECURE
HOLDING CELL
- SMALL (10)
SECURE
HOLDING CELL
- INDIVIDUAL
SECURE
HOLDING CELL
- INDIVIDUAL
SECURE
HOLDING CELL
- GROUP (16)
COURT
CLOTHES
TRANSACTION
WINDOW
CHANGING -
COURT
CLOTHES
RESTROOM-
INMATE
RESTROOM-
INMATE
PRINTER/
COPIER WORK
ALCOVE
TRANSPORT
EQUIPMENT
STORAGE
TRANSPORT
PEDESTRIAN
SALLYPORT
TRANSPORTATION
COORDINATOR
OPEN WAITING -
TRANSPORT - FEMALE
OPEN WAITING ARRESTEE
PRE-ADMISSION
BOOKING
TRANSACTION
STATION
MULTI USE
STATION
INTERVIEW
ROOM
LT. / SGT.'S OFFICE
HEALTH CARE
TRIAGE/
EXAMINATION
ROOM
TETHERING VENDOR
FINANCE
KIOSK
MEAL STAGING
TRASH
ALCOVE
JANITOR
CLOSET
OPEN WAITING
INTAKE
CORRIDOR
PRE-ADMISSION
PROCESSING
VALUABLE
PROPERTY
TRANSACTION
WINDOW
FULL BODY
SCANNER/STATION
CIRCULATION
VALUABLE
PROPERTY
STAGING
INTAKE
PROPERTY
TRANSACTION
WINDOW
JAIL
CLOTHING
STORAGE
TRASH
ALCOVE
OPEN
WAITING-
RELEASE
RELEASE PROPERTY STAGING
RELEASE
PROPERTY
TRANSACTION
WINDOW
RELEASE
CHANGING
SOILED
PROPERTY
STORAGE
COURT
CLOTHES
TRANSACTION
WINDOW
MH SERVICES
COORDINATOR
SHARED OFFICE-MENTAL
HEALTH
RESTROOM-
INMATE
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
STAFF
ENTRANCE
PEDESTRIAN
SALLYPORT
CLEAN OPEN WAITING -
FULL BODY SEARCHFULL BODY SCANNER/ STATION
VEHICLE SALLYPORT
INTERVIEW
ROOM
STAFF
SALLYPORT
SALLYPORT
CIRCULATION
SECURE
HOLDING ROOM
- COMBATANT
ARRESTEE
MALE FULL HEIGHT ASSIGNED
LOCKERS / CHANGING ROOM
MALE TOILET/
URINAL/ SINK
AREA
CIRCULATION
SALLYPORT
PUBLIC LOBBY
CIRCULATION
ENTRY VESTIBULE
OFFICER
STATION
RECEPTION
WORKSTATION
WEATHER
VESTIBULE
STAFF
BREAKROOM
CIRCULATION
ADMINISTRATIVE
SERGEANT
STAFF
RESTROOM
OFFICE
SUPPLIES
SECURE FILE
STORAGE
FOOD MARKET
KIOSKS
OPERATIONS
LIEUTENANT
ADMINISTRATIVE
LIEUTENANT
JAIL OFFICE
VALUABLE
PROPERTY
TRANSACTION
WINDOW
RELEASE
PROCESSING
STATION
EXIT
PASSAGEWAY
PRINTER/
COPIER
WORK
ALCOVE
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JAIL OFFICE
STATION
JANITOR CLOSET
SECURE
HOLDING CELL
- GROUP
ARRESTING
OFFICER
WORK AREA
SECURE
HOLDING CELL
- GROUP
RELEASE CORRIDOR
FEMALE
LOCKERS
VEST
MALE
LOCKERS
VEST
BREAK ROOM
SECURE
HOLDING CELL
- INDIVIDUAL
JAIL
ADMINISTRATOR
OPERATIONS
SERGEANT
PAT SEARCH ALCOVE
RESTROOM -
STAFF
EXCHANGE/
CHECK OUT
EXERCISE ROOM
LACTATION
ROOM
JAIL OFFICE
SUPERVISOR
FEMALE FULL
HEIGHT
ASSIGNED
LOCKERS /
CHANGING
ROOM
FEMALE
TOILET/SINK
AREA
FEMALE
SHOWER
ROOMS
PRINTER/
COPIER
WORK
ALCOVE
RESTROOM -
STAFF
LACTATION
ROOM
ELEVATOR LOBBY
ELECTRICAL ROOM
ADMINISTRATION
SERVICE
WINDOW
RECORDS/BOND
TRANSACTION
WINDOW
PAT SEARCH
ALCOVE
JAIL OFFICE
STATION
RESTROOM
INMATE
PRINTER
ALCOVE
JAIL OFFICE
STATION
MULTI USE
STATION
PRETRIAL
SERVICES
INTERVIEW
STATION
MULTI USE
STATION
DIRTY OPEN
WAITING -
FULL BODY
SEARCH
WAITING - VISITOR
PRE-ADMISSION
BOOKING
TRANSACTION
WINDOW
VALUABLE
PROPERTY
TRANSACTION
WINDOW
PRINTER/COPIER
WORK ALCOVE
CIRCULATION CIRCULATION
IDF-1A
RELEASE
PROCESSING
STATION
MULTI USE
STATION
MULTI USE
STATION
MULTI USE
STATION
INITIAL
CLASSIFIC
ATION
SCREANING MANUAL
FINGERPRINT
STATION
INITIAL
CLASSIFIC
ATION
SCREANING
PRETRIAL
SERVICES
INTERVIEW
STATION
PRETRIAL
SERVICES
INTERVIEW
STATION
PRETRIAL
SERVICES
INTERVIEW
STATION
RESTROOM-
LEO/STAFF
RESTROOM
STAFF
MENTAL
HEALTH
SCREENING
ROOM
STORAGE
CLOSET
MEDICAL
STORAGE
STAFF TOILET
SHOWER /
SEARCH
ROOM
CLEAN OPEN
WAITING
DIRTY OPEN
WAITING
RESTROOM-
INMATE
AFIS STATION
(LIVE SCAN &
PHOTO)
AFIS STATION
(LIVE SCAN &
PHOTO)
SECURE HOLDING CELL -
INDIVIDUAL
STORAGE
SECURE HOLDING CELL -
INDIVIDUAL SECURE HOLDING CELL -
INDIVIDUAL OFFICER
STATION
OPEN WAITING -
TRANSPORT - MALE
STAIR 1
ROOF HATCH
ACCESS /
STORAGE
PRE-ADMINISSION
GROUP
HOLDING CELL
(10)
JANITOR
CLOSET
JAIL OFFICE
STATION
G-
G-
INTERVIEW
ROOM
G-
INTERVIEW
ROOM
G-
G-
M
G-028G-
G-
G-051
G-055
2 2 2
G-
G-070 G-071
2 2 2 2 2 2 2
JAIL OFFICE
STATION
KEY WATCHER
SYSTEM
LOCATION
BREATHALYZER
ROOM
2 2
TV
TV
TV
TV
TV
TV
2 2
PH
PH
TV
TV
TV
TV
TV
CAMERA BY
FOOD VENDOR
G-129
G-13
G-13
G-132
G-13
DN
UPUP
UP
M M M
TV
TV
ZC+M
ALT#1
ZC+M
ALT#1
ZC+M
ALT#1
ZC+M
ALT#1
ZC+M
ALT#1
ZC+S
ALT#1
ZC+S
ALT#1
ZC+S
ALT#1
CAMERA/MIC
BY iRECORD
CAMERA/MIC
BY iRECORD
CAMERA/MIC
BY iRECORD
T1.06 2A
TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'B'
SCALE: 1/8" = 1'-0"
N
T1.01B
T1.01B
Owner
Project Name
Revisions
Drawn By
Checked By
Approved By
Sheet No.
Sheet Name
Project No.
KW
KW
KW
Issued
TECHNOLOGY
FLOOR PLAN -
GROUND LEVEL
AREA 'B'
25-T01 / MC 31-25
Macomb County 1 South Main St.
Mount Clemens, MI 48043
Macomb County Sheriff's Office 43565 Elizabeth Rd.
Mount Clemens, MI 48043
Key Plan
Bidding - Construction 06.12.2025
B A
CIAC BLDG
EXTG BLDG
59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com
GENERAL TECHNOLOGY NOTES:
1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS
AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.
2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES
AND REGULATIONS.
3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH
MANUFACTURER'S REGULATIONS.
4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND
FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL
DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER
NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE
CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE
CONSIDERED AS GROUNDS FOR AN EXTRA.
5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND
SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO
ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.
6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.
7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE
ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.
8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.
9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE
ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START
OF WORK.
10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,
ROOF, AND FIRE RATED WALLS.
11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS
THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.
12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR
SHEET.
13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN
LOCATIONS WITH CABLE TRAY.
14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A
MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE
BOX TO MEET ACOUSTICAL REQUIREMENTS.
15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE
SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS
CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.
16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS
REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY
PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.
17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY
OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.
18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL
INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING
AGENCY OF THE PERMIT.
19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR
THE SYSTEM THEY ARE ASSOCIATED WITH.
20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE
PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID
PACKAGE.
21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS
NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL
NOT EXCEED 40% FULL CAPACITY.
22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF
THIS PROJECT.
23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF
THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.
DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE
WRITTEN APPROVAL.
Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01
LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN
FUTURE TECHNOLOGY BID PACKAGE.
1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC
CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION
271300.
TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE
FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT
LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.
LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE
FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO
SPECIFICATION SECTION 271100.
TECHNOLOGY FLOOR PLAN KEYNOTES:
"X"
INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY
CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"
DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR
TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,
JUNCTION BOXES, ETC.)
INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR
BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A
TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL
CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.)
"X"
INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
AP
SYMBOL DESCRIPTION
TECHNOLOGY FLOOR PLAN LEGEND:
INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
X-000
ETR
INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO
REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.
X-000
"X"
INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT
(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND
INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING
INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)
TV
INDICATES LOCATION OF NEW EXTERNAL MICROPHONE TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. NO WORK REQUIRED IN THIS BID PACKAGE.M
LOCATION OF VIDEO VISITATION UNIT (BY OTHERS). ELECTRICAL
CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,
JUNCTION BOXES, ETC.).
VCCP
ZC+M
ZC+S
ALT#1
ALT#1
ALT#1
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER CONTROL
PANEL LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL TWO (2) DATA DROPS THIS LOCATION. VERIFY EXACT
LOCATION PRIOR TO INSTALLATION.
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ MAIN
MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE VCCP
IN THE LOCAL MDF/IDF. TECHNOLOGY CONTRACTOR SHALL
FURNISH AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+M
LOCATION TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE
RUN FOR BIDDING PURPOSES).
PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ SUB
MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
NEAREST ZC+M. TECHNOLOGY CONTRACTOR SHALL FURNISH
AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+S LOCATION
TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE RUN FOR
BIDDING PURPOSES).
8 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL AN ELEVATOR DEVICE
JUNCTION BOX FOR INTERFACE OF ELEVATOR DEVICES TO BE LOCATED
3 4
2-047
2-0502-044
2-049
2-051
2-074
2-073
2-075
2-0
2-091
2-090
2-092
2-071
2-
2-094
2-096
2-095
2-
2-072
2-064
2-069
2-048
AP AP
AP
AP
AP
AP
FIRST FLOOR ROOF
FIRST FLOOR ROOF
STAIR 2
STAIR 3
COURTYARD
EL
EV
. N o
EL
EV
. N o
EL
EV
. N o
EL
EV
. N o
SHARED
TABLET
CHARGING &
STORAGE
SHARED
PROPERTY
STORAGE AND
LAUNDRY
CART
STORAGE
INTERVIEW
ROOM
CALMING
ROOM
STORAGE
ROOM
SAFETY CELL
CALMING
ROOM
INTERVIEW
ROOM
ADA SHOWER/
CHANGING
SHOWER/
CHANGING
SHOWER/
CHANGING
SHOWER/
CHANGING
ADA SHOWER/
CHANGING
EXAM ROOM
GENERAL
EXAM ROOM
GENERAL
SHOWER/
CHANGING
STORAGE
SINGLE ROOM
ADA SINGLE
SINGLE ROOM
FRESH AIR
COURT
ADA SINGLE
ROOM
SINGLE ROOM
ADA SHOWER
SINGLE ROOM
SINGLE ROOM
SINGLE ROOM
SINGLE ROOM
SINGLE ROOM
SINGLE ROOM
ADA SINGLE
ROOM -
BARIATRIC
FRESH AIR
COURT
SINGLE ROOM
MEDICATION
ROOM
MEDICATION
STORAGE
ROOM
SALLYPORT
HOUSING POD
PEDESTRAIN
SALLYPORT
SHARED
SUPPLY
STORAGE
ROOM
DOUBLE ROOM
CIRCULATION
NURSE/OFFICER
WORKSTATION
CIRCULATION
DOUBLE ROOM
DOUBLE ROOM
DOUBLE ROOM
DOUBLE ROOM
ADA DOUBLE
ROOM
DOUBLE ROOM
DOUBLE ROOM
DOUBLE ROOM
DOUBLE ROOM
D0UBLE
OCCUPANCY
ROOM
ELECTRICAL
ELECTRICAL
IDF-2
NURSE/OFFICER
WORKSTATION
MECH. SHAFT
MECH. SHAFT
SHARED VIDEO
ARRAIGMENT
BOOTHS
FP CLOSET
DOUBLE ROOM
DAYROOM /
DINING / TV
FOOD &
BEVERAGE
STATION
JANITOR
CLOSET
OFFICER
WORKROOM
OFFICER
WORKROOM
RESTROOM -
STAFF
RESTROOM -
STAFF
NURSE/OFFICER
WORKSTATION
ELEVATOR
LOBBY
ADA SINGLE
ROOM -
BARIATRIC
SINGLE ROOM
ELECTRONICS
STORAGE /
REACHING
ELEVATOR
CORRIDOR
DAYROOM /
DINING / TV
ADA
MULTIFUNCTIONING
WATER
COOLER FOOD &
BEVERAGE
STATION
MULTIFUNCTIONAL
KIOSK
DAYROOM /
DINING / TV
ADA
MULTIFUNCTIONING
MULTIFUNCTIONAL
KIOSK
STAFF
RESTROOM
STAFF
RESTROOM
CORRIDOR
MECH. SHAFT
MECH. SHAFT
MECH. SHAFT
FIRE
SPRINKLERS
PIPE SHAFT
ADA SINGLE
ROOM -
BARIATRIC
SINGLE ROOM
MALE ACUTE 2
9 BED
(7 SINGLE, 2 ADA
BARIATRIC)
1 ADA SHOWER + 1
SHOWER
1 FRESH AIR COURT
MALE ACUTE 1
HIGH OBSERVATION
7 BED
(6 SINGLE, 1 ADA
BARIATRIC)
1 ADA SHOWER
1 FRESH AIR COURT
MALE SUBACUTE
27 BED
3 SHOWER + 1 ADA
SHOWER
SINGLE ROOM
SINGLE ROOM
MULTI
PURPOSE
ROOM
MULTI
PURPOSE
ROOM
2 2
2-046
2-045
TV TV
2-
2-
2-076
2-088
2-
AREA AAREA B
AREA AAREA B
2-052
2-053
2-054
2-055
2-056
2-103
SINGLE ROOM
2-057
2-058
2-059
2-060 2-062
2-063
2-065
2-067
2-068
2-070
2 PH
TV
TV
VV
TV
VV
PH
TV
2-105 2-1
2-102
2-1
UPUP
UP
TV
VCCP
ALT#1
ZC+M
ALT#1
ZC+M
ALT#1
ZC+S
ALT#1
ZC+S
ALT#1
ZC+M
ALT#1
ZC+S
ALT#1
ZC+S
ALT#1
ZC+M
ALT#1
ZC+M
ALT#1
ZC+S
ALT#1
ZC+S
ALT#1
ZC+S
ALT#1
ZC+S
ALT#1
ZC+M
ALT#1
ZC+S
ALT#1
T1.06
TECHNOLOGY FLOOR PLAN - 2nd FLOOR AREA 'A'
SCALE: 1/8" = 1'-0"
N
T1.02A
T1.02A
Owner
Project Name
Revisions
Drawn By
Checked By
Approved By
Sheet No.
Sheet Name
Project No.
KW
KW
KW
Issued
TECHNOLOGY
FLOOR PLAN -
2ND FLOOR
AREA 'A'
25-T01 / MC 31-25
Macomb County 1 South Main St.
Mount Clemens, MI 48043
Macomb County Sheriff's Office 43565 Elizabeth Rd.
Mount Clemens, MI 48043
Key Plan
Bidding - Construction 06.12.2025
B A
CIAC BLDG
EXTG BLDG
59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com
GENERAL TECHNOLOGY NOTES:
1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS
AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.
2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES
AND REGULATIONS.
3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH
MANUFACTURER'S REGULATIONS.
4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND
FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL
DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER
NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE
CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE
CONSIDERED AS GROUNDS FOR AN EXTRA.
5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND
SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO
ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.
6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.
7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE
ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.
8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.
9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE
ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START
OF WORK.
10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,
ROOF, AND FIRE RATED WALLS.
11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS
THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.
12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR
SHEET.
13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN
LOCATIONS WITH CABLE TRAY.
14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A
MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE
BOX TO MEET ACOUSTICAL REQUIREMENTS.
15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE
SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS
CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.
16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS
REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY
PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.
17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY
OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.
18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL
INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING
AGENCY OF THE PERMIT.
19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR
THE SYSTEM THEY ARE ASSOCIATED WITH.
20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE
PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID
PACKAGE.
21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS
NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL
NOT EXCEED 40% FULL CAPACITY.
22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF
THIS PROJECT.
23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF
THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.
DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE
WRITTEN APPROVAL.
Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01
LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN
FUTURE TECHNOLOGY BID PACKAGE.
1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC
CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.
ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION
271300.
TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE
FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO
PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.).
7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT
LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.
LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE
FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO
SPECIFICATION SECTION 271100.
TECHNOLOGY FLOOR PLAN KEYNOTES:
"X"
INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY
CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"
DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR
TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,
JUNCTION BOXES, ETC.)
INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR
BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A
TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL
CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE
(CONDUITS, JUNCTION BOXES, ETC.)
"X"
INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
AP
SYMBOL DESCRIPTION
TECHNOLOGY FLOOR PLAN LEGEND:
INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE
FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY
BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND
INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE
LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL
SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,
ETC.)
X-000
ETR
INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO
REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.
X-000
"X"
INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT
(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND
INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.