About this file

The document is a set of technology infrastructure design drawings for the Macomb County Central Intake & Assessment Center and Jail Renovations project, prepared by Metro Technology Services for the Macomb County Office of the Sheriff. The drawings detail a comprehensive technology infrastructure upgrade, specifically focusing on structured cabling and communication equipment room fittings across multiple building levels, including basement, ground, second, third, fourth, and penthouse levels. The technical bid package (25-T01) is dated June 12, 2025, and covers the installation of network infrastructure, security electronics, access control systems, video management systems, and associated technical equipment throughout the facility located at 43565 Elizabeth Road in Mount Clemens, Michigan.

The drawings provide extensive technical specifications for technology infrastructure, including detailed floor plans showing precise locations for data drops, wireless access points, surveillance cameras, intercom systems, card readers, and other network and security devices. The project appears to be comprehensively planned, with specific notes about electrical requirements, conduit installations, cable routing, and integration of various technological systems. The technology contractor will be responsible for furnishing and installing structured cabling, including backbone fiber optic cabling and horizontal cabling across all specified drawings, with devices and equipment to be provided by others. The technical specifications emphasize compliance with national, state, and local codes, and include detailed requirements for cable management, power supply, and system integration.

View the file

Other files for this state and local contract opportunity

Other files attached to CIAC - Tech Package - Structured Cabling & Communication Equipment Room Fittings, newest first.
File Type Posted
RFP 31-25 CIAC - Technology Bid Package 25-T01 Structured Cabling _ Communication Equipment Room Fittings.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T0.00

Owner

Project Name

Revisions

Drawn By

Checked By

Approved By

Sheet No.

Sheet Name

Project No.

KW

KW

KW

Issued

COVER SHEET

25-T01 / MC 31-25

Macomb County 1 South Main St.

Mount Clemens, MI 48043

Macomb County Central Intake & Assessment

Macomb County Sheriff's Office 43565 Elizabeth Rd.

Mount Clemens, MI 48043

Key Plan

Bidding - Construction 06.12.2025

59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com

Center / Jail Renovations

Index of Drawings

DWG# DRAWING TITLE

TECHNOLOGY DRAWINGS:

TS1.00

TECHNOLOGY FLOOR PLAN - LOWER LEVEL AREA 'A'T1.00A

TECHNOLOGY SITE PLAN

TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'A' T1.01A

TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'B'T1.01B

TECHNOLOGY FLOOR PLAN - 2ND FLOOR AREA 'A'T1.02A

T1.02B T1.03A T1.03B T1.04A T1.04B

T1.04MA

T1.04MB

T1.05A T1.05B

ENLARGED TECHNOLOGY PLANS AND DETAILST1.06

TECHNOLOGY FLOOR PLAN - MCJ LOWER LEVELT1.07

TECHNOLOGY FLOOR PLAN - MCJ GROUND LEVELT.1.08

TECHNOLOGY FLOOR PLAN - MCJ SECOND LEVELT.1.09

T-01

TECHNOLOGY FLOOR PLAN - 2ND FLOOR AREA 'B'

TECHNOLOGY FLOOR PLAN - 3RD FLOOR AREA 'A'

TECHNOLOGY FLOOR PLAN - 3RD FLOOR AREA 'B'

TECHNOLOGY FLOOR PLAN - 4TH FLOOR AREA 'A'

TECHNOLOGY FLOOR PLAN - 4TH FLOOR AREA 'B'

TECHNOLOGY FLOOR PLAN - 4TH FLOOR MEZZANINE AREA 'A'

TECHNOLOGY FLOOR PLAN - 4TH FLOOR MEZZANINE AREA 'B'

TECHNOLOGY FLOOR PLAN - PENTHOUSE AREA 'A'

TECHNOLOGY FLOOR PLAN - PENTHOUSE AREA 'B'

SECURITY ELECTRONICS DRAWINGS:

SECURITY ELECTRONICS - SYMBOL LEGENDSE000

SECURITY ELECTRONICS - SITE PLAN SE100

SE101

SE102

SE103

SE104

SE105

SE106

SE107

SE108

SE109

SE110

SE111

SE112

SE113

SE114

SE115

SE200

Tech Bid Package 25-T01

Location Map

Macomb County Central Intake & Assessment Center / Jail Renovations Macomb County Sheriff's Office 43565 Elizabeth Rd.

Mount Clemens, MI 48043

Structured Cabling & Communication Equipment Room Fittings Technology Bid Package 25-T01

Bid Number: 31-25 Date: June 12, 2025

T-03T-02

PROPOSAL NUMBER

SE201

SE300

SE301

SE302

SECURITY ELECTRONICS - SITE PLAN ENLARGED DETAILS

SECURITY ELECTRONICS - BASEMENT LEVEL - AREA A

SECURITY ELECTRONICS - GROUND LEVEL - AREA A

SECURITY ELECTRONICS - GROUND LEVEL - AREA B

SECURITY ELECTRONICS - SECOND LEVEL - AREA A

SECURITY ELECTRONICS - SECOND LEVEL - AREA B

SECURITY ELECTRONICS - THIRD LEVEL - AREA A

SECURITY ELECTRONICS - THIRD LEVEL - AREA B

SECURITY ELECTRONICS - FOURTH LEVEL - AREA A

SECURITY ELECTRONICS - FOURTH LEVEL - AREA B

SECURITY ELECTRONICS - FOURTH LEVEL MEZZANINE - AREA A

SECURITY ELECTRONICS - FOURTH LEVEL MEZZANINE - AREA B

SECURITY ELECTRONICS - MECH PENTHOUSE LEVEL - AREA A

SECURITY ELECTRONICS - MECH PENTHOUSE LEVEL - AREA B

SECURITY ELECTRONICS - ENLARGED DETAILS

SECURITY ELECTRONICS - INTERCONNECT

SECURITY ELECTRONICS - INTERCONNECT CONT.

SECURITY ELECTRONICS - TYPICAL EQUIPMENT ROOM

SECURITY ELECTRONICS - TYPICAL DOOR INSTALLATION

SECURITY ELECTRONICS - ONE LINE DIAGRAMS

E-012

E-010E-011 E-009

E-0

E-015

E-003E-002 E-004

E-017

E-018

E-027

E-028

ENTER

EXIT

ENTER

EXIT

STAFF PARKING LOT

SERVICE YARD

STAFF PARKING LOT

ENTER

EXIT

EXIT

E-023

E-022

E-019

E-020

ET

R

ET

R

ET

R

E-024

E-025

E-026

E-021

E-016

E-001

E-014

E-013 E-007

E-006

E-005

TECHNOLOGY SITE PLAN

SCALE: 1" = 20'-0"

N

TS1.00

1 1

TS1.00

Owner

Project Name

Revisions

Drawn By

Checked By

Approved By

Sheet No.

Sheet Name

Project No.

KW

KW

KW

Issued

TECHNOLOGY

SITE PLAN

25-T01 / MC 31-25

Macomb County 1 South Main St.

Mount Clemens, MI 48043

Macomb County Sheriff's Office 43565 Elizabeth Rd.

Mount Clemens, MI 48043

Key Plan

Bidding - Construction 06.12.2025

B A

CIAC BLDG

EXTG BLDG

59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS

AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.

2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES

AND REGULATIONS.

3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH

MANUFACTURER'S REGULATIONS.

4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND

FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL

DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER

NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE

CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE

CONSIDERED AS GROUNDS FOR AN EXTRA.

5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND

SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE

PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO

ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.

6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.

7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE

ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.

8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.

9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE

ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START

OF WORK.

10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,

ROOF, AND FIRE RATED WALLS.

11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS

THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.

12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR

SHEET.

13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN

LOCATIONS WITH CABLE TRAY.

14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A

MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE

BOX TO MEET ACOUSTICAL REQUIREMENTS.

15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE

SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS

CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.

16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS

REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY

PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.

17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY

OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.

18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL

INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING

AGENCY OF THE PERMIT.

19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR

THE SYSTEM THEY ARE ASSOCIATED WITH.

20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE

PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID

PACKAGE.

21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS

NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL

NOT EXCEED 40% FULL CAPACITY.

22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR

SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF

THIS PROJECT.

23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF

THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.

DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE

WRITTEN APPROVAL.

Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01

INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF (UNLESS NOTED OTHERWISE IN THE KEYNOTES

BELOW). ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING

INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)

SYMBOL DESCRIPTION

TECHNOLOGY FLOOR PLAN LEGEND:

X-000

ETR

INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO

REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.

X-000

TECHNOLOGY FLOOR PLAN KEYNOTES:

1 SURVEILLANCE CAMERA TO BE POLE-MOUNTED THIS LOCATION (BY OTHERS).

TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL ONE (1) COMPOSITE

CABLE (OPTICAL FIBER & COPPER CABLE - SIMILAR TO CORNING ACTIFI FIBER

CABLE, 2 FIBERS) FROM THE NEAREST MDF/IDF TO THIS LOCATION.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.).

SURVEILLANCE CAMERA TO BE SURFACE-MOUNTED ON UNDERSIDE OF

CANOPY THIS LOCATION.

SURVEILLANCE CAMERA TO BE PEDESTAL-MOUNTED THIS LOCATION (BY

OTHERS). TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL ONE (1)

COMPOSITE CABLE (OPTICAL FIBER & COPPER CABLE - SIMILAR TO CORNING

ACTIFI FIBER CABLE, 2 FIBERS) FROM THE NEAREST MDF/IDF TO THIS

LOCATION. ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING

INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.).

L-0

L-008

L-010

L-006L-003

L-004

L-005

L-001

L-0

L-007

FIRE PUMP ROOM

PLUMBING/ WATER HEATER

ROOM

MDF

MECHANICAL

FRESH AIR INTAKE AREAWAY

CORRIDOR

EMER ELECELECTRICAL ROOM

ELEC SUBSTATION RM

STAIR 2

STAIR 3

ELEVATOR LOBBY

MECHANICAL

AREA AAREA B

AREA AAREA B

UP

UP

AP

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS

AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.

2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES

AND REGULATIONS.

3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH

MANUFACTURER'S REGULATIONS.

4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND

FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL

DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER

NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE

CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE

CONSIDERED AS GROUNDS FOR AN EXTRA.

5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND

SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE

PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO

ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.

6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.

7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE

ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.

8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.

9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE

ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START

OF WORK.

10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,

ROOF, AND FIRE RATED WALLS.

11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS

THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.

12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR

SHEET.

13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN

LOCATIONS WITH CABLE TRAY.

14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A

MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE

BOX TO MEET ACOUSTICAL REQUIREMENTS.

15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE

SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS

CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.

16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS

REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY

PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.

17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY

OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.

18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL

INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING

AGENCY OF THE PERMIT.

19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR

THE SYSTEM THEY ARE ASSOCIATED WITH.

20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE

PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID

PACKAGE.

21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS

NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL

NOT EXCEED 40% FULL CAPACITY.

22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR

SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF

THIS PROJECT.

23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF

THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.

DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE

WRITTEN APPROVAL.

TECHNOLOGY FLOOR PLAN - LOWER LEVEL AREA 'A'

SCALE: 1/8" = 1'-0"

N

T1.00A

2 2 2 2

T1.06

T1.00A

Owner

Project Name

Revisions

Drawn By

Checked By

Approved By

Sheet No.

Sheet Name

Project No.

KW

KW

KW

Issued

TECHNOLOGY

FLOOR PLAN -

LOWER LEVEL

AREA 'A'

25-T01 / MC 31-25

Macomb County 1 South Main St.

Mount Clemens, MI 48043

Macomb County Sheriff's Office 43565 Elizabeth Rd.

Mount Clemens, MI 48043

Key Plan

Bidding - Construction 06.12.2025

B A

CIAC BLDG

EXTG BLDG

59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com

Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01

LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN

FUTURE TECHNOLOGY BID PACKAGE.

1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC

CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION

271300.

TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE

FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT

LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.

LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE

FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO

SPECIFICATION SECTION 271100.

TECHNOLOGY FLOOR PLAN KEYNOTES:

"X"

INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY

CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"

DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR

TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,

JUNCTION BOXES, ETC.)

INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR

BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A

TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL

CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.)

"X"

INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

AP

SYMBOL DESCRIPTION

TECHNOLOGY FLOOR PLAN LEGEND:

INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

X-000

ETR

INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO

REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.

X-000

"X"

INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT

(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND

INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING

INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)

TV

INDICATES LOCATION OF NEW EXTERNAL MICROPHONE TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. NO WORK REQUIRED IN THIS BID PACKAGE.M

LOCATION OF VIDEO VISITATION UNIT (BY OTHERS). ELECTRICAL

CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,

JUNCTION BOXES, ETC.).

VCCP

ZC+M

ZC+S

ALT#1

ALT#1

ALT#1

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER CONTROL

PANEL LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL TWO (2) DATA DROPS THIS LOCATION. VERIFY EXACT

LOCATION PRIOR TO INSTALLATION.

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ MAIN

MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE VCCP

IN THE LOCAL MDF/IDF. TECHNOLOGY CONTRACTOR SHALL

FURNISH AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+M

LOCATION TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE

RUN FOR BIDDING PURPOSES).

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ SUB

MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

NEAREST ZC+M. TECHNOLOGY CONTRACTOR SHALL FURNISH

AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+S LOCATION

TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE RUN FOR

BIDDING PURPOSES).

8 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL AN ELEVATOR DEVICE

JUNCTION BOX FOR INTERFACE OF ELEVATOR DEVICES TO BE LOCATED

WITHIN THE ELEVATOR CABS. REFER TO SPECIFICATION SECTION 271500.

2 2

2 2

2 2 2 2

2 (COPIER)

2 2

2 2

2 2

(COPIER)

2 2

2 2

2 2

3 3 3

(COPIER)

G-062

G-057

G-059

G-058

G-061

G-063

G-085

G-083G-080

G-086

G-084

G-104 G-105

G-107

G-106

G-113

G-081

G-116

G-117

G-066

G-064

G-06 5 G-068

G-06

G-087

G-088

G-089 G-115G-114

G-118

G-126

G-075

G-074

G-072

TV

TV

G-079

G-077

G-076

G-073

G-103

G-094

G-096

2-TV

G-127

G-125 G-097

G-098

G-128

G-119

G-120

G-122

G-121

G-123

AP

AP

AP

AP

AP

AP

AP AP

AP

AP

AP AP

AP

AP

AP

AP

AP

AP

AP

(COPIER)

G-060

G-039

TV

AREA AAREA B

AREA AAREA B

PROPERTY STORAGE ROOM

INTERVIEW

ROOM

LT. / SGT.'S OFFICE

TETHERING VENDOR

FINANCE

KIOSK

TRASH

ALCOVE

JANITOR

CLOSET

CLINIC

PEDESTRIAN

SALLYPORT

OPEN WAITING - CLINIC

SECURE

WAITING

SECURE

WAITING

RECEPTION AND NURSING

STATION

EXAMINATION

ROOM -

GENERAL

DIALYSIS

SUITE

SUPPORT EXAMINATION

ROOM-

TRAUMA/ORTHO

SPECIALIZED

TREATMENT

EXAMINATION

ROOM- MINOR

PROCEDURES

EXAM PREP

AND

PHLEBOTOMY

ALCOVE

DENTAL EXAM ROOM

DENTAL

LAB/WORKROOM

AIR

COMPRESSOR

CLOSET

DOCTOR/

MEDICAL

DIRECTOR

OFFICE

MEDICAL

SUPPLY ROOM

MEDICATION STORAGE

MEDICAL

EQUIPMENT

STORAGE

CHARTING AREA

CLEAN UTILITY DIRTY UTILITY

ICE MAKER&

NOURISHMENT

PANTRY

Water Cooler

RESTROOM -

INMATE

RESTROOM -

STAFF

DIALYSIS

SPACE

EXAMINATION

ROOM -

GENERAL

EXAMINATION

ROOM -

GENERAL

EXAMINATION

ROOM -

GENERAL

INTERVIEW ROOM

EXTERIOR COURTYARD

JAIL

CLOTHING

STORAGE

TRASH

ALCOVE

OPEN

WAITING-

RELEASE

RELEASE PROPERTY STAGING

RELEASE

PROPERTY

TRANSACTION

WINDOW

RELEASE

CHANGING

HEALTH

SERVICES

ADMINISTRATOR

PSYCHIATRIST/MH

NURSE

PRACTITIONER

MH SERVICES

COORDINATOR

MEDICAL

RECORDS

STORAGE

SHARED OFFICE-MENTAL

HEALTH

DIRECTOR OF

NURSING

MEDICAL

RECORDS

CLERK

PRINTER/ COPIER ALCOVE

BREAKROOM - STAFF

CONFERENCE

ROOM

RECREATIONAL

LIBRARY BOOKS

ALCOVE

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

CLINIC SERVICES -

CIRCULATION

STAFF

ENTRANCE

PEDESTRIAN

SALLYPORT

CLEAN OPEN WAITING -

FULL BODY SEARCHFULL BODY SCANNER/ STATION

SECURE CORRIDOR

IDF-1

STAFF CIRCULATION

CLINIC OFFICER WORKSTATION

CORRIDOR

DEPUTY DIRECTOR

CLINICAL MANAGER

CLERICAL

SPECIALIST

BREAKROOM -

STAFF

INTERVIEW ROOM

WAITING AREA

CLERICAL

SPECIALIST

CLERICAL

SPECIALIST

SALLYPORT

PUBLIC LOBBY

CIRCULATION

ENTRY VESTIBULE

INTERVIEW ROOMS

INTERVIEW ROOMS

NONCONTACT

VISIT BOOTH -

ADA

NONCONTACT

VISIT BOOTH -

ADA

RELEASE

RESOURCE

INTERVIEW

ROOM

RELEASE

RESOURCE

INTERVIEW

ROOM

OFFICER

STATION

COMMUNITY CORRECTIONS

STAFF

SALLYPORT

LOCKERS

CIRCULATION

ADMINISTRATIVE

SERGEANT

STAFF

RESTROOM

OFFICE

SUPPLIES

SECURE FILE

STORAGE

OPERATIONS

LIEUTENANT

ADMINISTRATIVE

LIEUTENANT COMMUNITY

CORRECTIONS

DIRECTOR

EXECUTIVE

WORKROOM

+STORAGE

PRINTER/COPIER

WORK ALCOVE

JAIL OFFICE

PUBLIC

RESTROOM

PUBLIC

RESTROOM

ANTEROOM

PRINTER/

COPIER

WORK

ALCOVE

JANITOR

CLOSET

PUBLIC

NONCONTACT

VISIT BOOTH -

ADA

PUBLIC

NONCONTACT

VISIT BOOTH -

ADA

JAIL OFFICE

STATION

CONFERENCE ROOM

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

SECURE

PASSAGE

CONNECTION

RELEASE CORRIDOR

FIRE DEPT. CONTROL ROOM

BREAK ROOM

VIDEO

ARAIGNMENT

BOOTHS

STAFF LOCKER ROOM

JANITOR

CLOSET

RESTROOM -

INMATE

JAIL

ADMINISTRATOR

PRINTER/COPIER

WORK ALCOVE

RESTROOM-

INMATE

SECURE WAITING - TEL

SECURE WAITING - TEL

OFFICER

BOOTH

EXCHANGE/

CHECK OUT

UPS

EXERCISE ROOM

JAIL OFFICE

SUPERVISOR

RESTROOM -

STAFF

RESTROOM -

STAFF

RESTROOM -

STAFF

PRINTER/

COPIER

WORK

ALCOVE

RESTROOM -

STAFF

LACTATION

ROOM

RESTROOM -

STAFF

LACTATION

ROOM

CORRIDOR

JANITORS

CLOSET

ADA SHOWER/

CHANGING

CORRIDOR

ELEVATOR LOBBY

RESTROOM -

STAFF

CENTRAL CONTROL

ELECTRICAL ROOM

CONTROL

ROOM

SALLYPORT

ELECTRICAL ROOM

DECON ROOM

STAFF

ADMINISTRATION

SERVICE

WINDOW

RECORDS/BOND

TRANSACTION

WINDOW

WATER

COOLER

CORRIDOR

JAIL OFFICE

STATION

RESTROOM

INMATE

PRINTER

ALCOVE

JAIL OFFICE

STATION

DIRTY OPEN

WAITING -

FULL BODY

SEARCH

SALLYPORT

VESTIBULE

WAITING - VISITOR

RESTROOM -

STAFF

RESTROOM -

STAFF

JANITORS

CLOSET

COMMUNITY CORRECTIONS

STAFF

FIRE

SPRINKLERS

PIPE SHAFT

MECH SHAFT MECH SHAFT

CIRCULATION CIRCULATION

STORAGE

CLOSET

MEDICAL

STORAGE

STAFF TOILET

COMMUNITY CORRECTIONS

STAFF

OPEN WAITING - TELOFFICER

STATION

LOCKERS /

CORRIDOR

ROOF HATCH

ACCESS /

STORAGE

ADMIN.

ASSISTANT

JAIL OFFICE

STATION

G-

G-070 G-071

2 2 2 2 2 2 2

JAIL OFFICE

STATION

G-095

4 TV4 TV

G-111

G-112

2 2

2 2

G-108

G-124

G-102

G-101

G-100

G-099

G-082

G-093G-

G-

0 G-091

KEY WATCHER

SYSTEM

LOCATION

2 2

TV

TV

2-TV2

PH

TV

TV

TV

TV

G-13

DN

UPUP

UPUP

UP

VCCP

ALT#1

ZC+M

ALT#1

ZC+M

ALT#1

ZC+M

ALT#1

T1.06

TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'A'

SCALE: 1/8" = 1'-0"

N

T1.01A

T1.01A

Owner

Project Name

Revisions

Drawn By

Checked By

Approved By

Sheet No.

Sheet Name

Project No.

KW

KW

KW

Issued

TECHNOLOGY

FLOOR PLAN -

GROUND LEVEL

AREA 'A'

25-T01 / MC 31-25

Macomb County 1 South Main St.

Mount Clemens, MI 48043

Macomb County Sheriff's Office 43565 Elizabeth Rd.

Mount Clemens, MI 48043

Key Plan

Bidding - Construction 06.12.2025

B A

CIAC BLDG

EXTG BLDG

59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS

AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.

2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES

AND REGULATIONS.

3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH

MANUFACTURER'S REGULATIONS.

4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND

FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL

DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER

NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE

CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE

CONSIDERED AS GROUNDS FOR AN EXTRA.

5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND

SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE

PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO

ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.

6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.

7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE

ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.

8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.

9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE

ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START

OF WORK.

10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,

ROOF, AND FIRE RATED WALLS.

11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS

THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.

12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR

SHEET.

13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN

LOCATIONS WITH CABLE TRAY.

14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A

MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE

BOX TO MEET ACOUSTICAL REQUIREMENTS.

15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE

SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS

CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.

16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS

REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY

PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.

17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY

OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.

18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL

INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING

AGENCY OF THE PERMIT.

19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR

THE SYSTEM THEY ARE ASSOCIATED WITH.

20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE

PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID

PACKAGE.

21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS

NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL

NOT EXCEED 40% FULL CAPACITY.

22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR

SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF

THIS PROJECT.

23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF

THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.

DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE

WRITTEN APPROVAL.

Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01

LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN

FUTURE TECHNOLOGY BID PACKAGE.

1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC

CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION

271300.

TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE

FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT

LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.

LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE

FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO

SPECIFICATION SECTION 271100.

TECHNOLOGY FLOOR PLAN KEYNOTES:

"X"

INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY

CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"

DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR

TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,

JUNCTION BOXES, ETC.)

INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR

BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A

TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL

CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.)

"X"

INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

AP

SYMBOL DESCRIPTION

TECHNOLOGY FLOOR PLAN LEGEND:

INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

X-000

ETR

INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO

REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.

X-000

"X"

INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT

(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND

INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING

INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)

TV

INDICATES LOCATION OF NEW EXTERNAL MICROPHONE TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. NO WORK REQUIRED IN THIS BID PACKAGE.M

LOCATION OF VIDEO VISITATION UNIT (BY OTHERS). ELECTRICAL

CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,

JUNCTION BOXES, ETC.).

VCCP

ZC+M

ZC+S

ALT#1

ALT#1

ALT#1

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER CONTROL

PANEL LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL TWO (2) DATA DROPS THIS LOCATION. VERIFY EXACT

LOCATION PRIOR TO INSTALLATION.

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ MAIN

MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE VCCP

IN THE LOCAL MDF/IDF. TECHNOLOGY CONTRACTOR SHALL

FURNISH AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+M

LOCATION TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE

RUN FOR BIDDING PURPOSES).

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ SUB

MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

NEAREST ZC+M. TECHNOLOGY CONTRACTOR SHALL FURNISH

AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+S LOCATION

TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE RUN FOR

BIDDING PURPOSES).

2 2

8 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL AN ELEVATOR DEVICE

2 (COPIER)

2 2 2

2 2

2 2

2 2

(COPIER)

2 2

2 2

G-056

G-046 G-047

G-026

G-024

G-02

G-04

G-025

G-041

G-02

G-01

G-01

G-021

G-015

G-022

G-014

G-013

G-053

G-052

G-040

G-042

G-045

G-062

G-035 G-03

G-03

G-050

G-

G-

G-

G-

G-

G-

G-004

G-005

G-006

G-008

G-017 G-057G-033

G-059G-034

G-058

G-061

G-063

G-080

G-066

G-064

G-06 5 G-068

G-06

G-087

G-089

G-075

G-074

G-072

TV

TV

G-079

G-077

G-076

G-073

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

G-016

G-038

(COPIER)

G-060

G-039

G-02

G-049

G-048

TV

TV

M

M

AREA AAREA B

AREA AAREA B

PROPERTY STORAGE ROOM

CAROSEL

SECURE

HOLDING CELL

- SMALL (10)

SECURE

HOLDING CELL

- INDIVIDUAL

SECURE

HOLDING CELL

- INDIVIDUAL

SECURE

HOLDING CELL

- GROUP (16)

COURT

CLOTHES

TRANSACTION

WINDOW

CHANGING -

COURT

CLOTHES

RESTROOM-

INMATE

RESTROOM-

INMATE

PRINTER/

COPIER WORK

ALCOVE

TRANSPORT

EQUIPMENT

STORAGE

TRANSPORT

PEDESTRIAN

SALLYPORT

TRANSPORTATION

COORDINATOR

OPEN WAITING -

TRANSPORT - FEMALE

OPEN WAITING ARRESTEE

PRE-ADMISSION

BOOKING

TRANSACTION

STATION

MULTI USE

STATION

INTERVIEW

ROOM

LT. / SGT.'S OFFICE

HEALTH CARE

TRIAGE/

EXAMINATION

ROOM

TETHERING VENDOR

FINANCE

KIOSK

MEAL STAGING

TRASH

ALCOVE

JANITOR

CLOSET

OPEN WAITING

INTAKE

CORRIDOR

PRE-ADMISSION

PROCESSING

VALUABLE

PROPERTY

TRANSACTION

WINDOW

FULL BODY

SCANNER/STATION

CIRCULATION

VALUABLE

PROPERTY

STAGING

INTAKE

PROPERTY

TRANSACTION

WINDOW

JAIL

CLOTHING

STORAGE

TRASH

ALCOVE

OPEN

WAITING-

RELEASE

RELEASE PROPERTY STAGING

RELEASE

PROPERTY

TRANSACTION

WINDOW

RELEASE

CHANGING

SOILED

PROPERTY

STORAGE

COURT

CLOTHES

TRANSACTION

WINDOW

MH SERVICES

COORDINATOR

SHARED OFFICE-MENTAL

HEALTH

RESTROOM-

INMATE

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

STAFF

ENTRANCE

PEDESTRIAN

SALLYPORT

CLEAN OPEN WAITING -

FULL BODY SEARCHFULL BODY SCANNER/ STATION

VEHICLE SALLYPORT

INTERVIEW

ROOM

STAFF

SALLYPORT

SALLYPORT

CIRCULATION

SECURE

HOLDING ROOM

- COMBATANT

ARRESTEE

MALE FULL HEIGHT ASSIGNED

LOCKERS / CHANGING ROOM

MALE TOILET/

URINAL/ SINK

AREA

CIRCULATION

SALLYPORT

PUBLIC LOBBY

CIRCULATION

ENTRY VESTIBULE

OFFICER

STATION

RECEPTION

WORKSTATION

WEATHER

VESTIBULE

STAFF

BREAKROOM

CIRCULATION

ADMINISTRATIVE

SERGEANT

STAFF

RESTROOM

OFFICE

SUPPLIES

SECURE FILE

STORAGE

FOOD MARKET

KIOSKS

OPERATIONS

LIEUTENANT

ADMINISTRATIVE

LIEUTENANT

JAIL OFFICE

VALUABLE

PROPERTY

TRANSACTION

WINDOW

RELEASE

PROCESSING

STATION

EXIT

PASSAGEWAY

PRINTER/

COPIER

WORK

ALCOVE

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JAIL OFFICE

STATION

JANITOR CLOSET

SECURE

HOLDING CELL

- GROUP

ARRESTING

OFFICER

WORK AREA

SECURE

HOLDING CELL

- GROUP

RELEASE CORRIDOR

FEMALE

LOCKERS

VEST

MALE

LOCKERS

VEST

BREAK ROOM

SECURE

HOLDING CELL

- INDIVIDUAL

JAIL

ADMINISTRATOR

OPERATIONS

SERGEANT

PAT SEARCH ALCOVE

RESTROOM -

STAFF

EXCHANGE/

CHECK OUT

EXERCISE ROOM

LACTATION

ROOM

JAIL OFFICE

SUPERVISOR

FEMALE FULL

HEIGHT

ASSIGNED

LOCKERS /

CHANGING

ROOM

FEMALE

TOILET/SINK

AREA

FEMALE

SHOWER

ROOMS

PRINTER/

COPIER

WORK

ALCOVE

RESTROOM -

STAFF

LACTATION

ROOM

ELEVATOR LOBBY

ELECTRICAL ROOM

ADMINISTRATION

SERVICE

WINDOW

RECORDS/BOND

TRANSACTION

WINDOW

PAT SEARCH

ALCOVE

JAIL OFFICE

STATION

RESTROOM

INMATE

PRINTER

ALCOVE

JAIL OFFICE

STATION

MULTI USE

STATION

PRETRIAL

SERVICES

INTERVIEW

STATION

MULTI USE

STATION

DIRTY OPEN

WAITING -

FULL BODY

SEARCH

WAITING - VISITOR

PRE-ADMISSION

BOOKING

TRANSACTION

WINDOW

VALUABLE

PROPERTY

TRANSACTION

WINDOW

PRINTER/COPIER

WORK ALCOVE

CIRCULATION CIRCULATION

IDF-1A

RELEASE

PROCESSING

STATION

MULTI USE

STATION

MULTI USE

STATION

MULTI USE

STATION

INITIAL

CLASSIFIC

ATION

SCREANING MANUAL

FINGERPRINT

STATION

INITIAL

CLASSIFIC

ATION

SCREANING

PRETRIAL

SERVICES

INTERVIEW

STATION

PRETRIAL

SERVICES

INTERVIEW

STATION

PRETRIAL

SERVICES

INTERVIEW

STATION

RESTROOM-

LEO/STAFF

RESTROOM

STAFF

MENTAL

HEALTH

SCREENING

ROOM

STORAGE

CLOSET

MEDICAL

STORAGE

STAFF TOILET

SHOWER /

SEARCH

ROOM

CLEAN OPEN

WAITING

DIRTY OPEN

WAITING

RESTROOM-

INMATE

AFIS STATION

(LIVE SCAN &

PHOTO)

AFIS STATION

(LIVE SCAN &

PHOTO)

SECURE HOLDING CELL -

INDIVIDUAL

STORAGE

SECURE HOLDING CELL -

INDIVIDUAL SECURE HOLDING CELL -

INDIVIDUAL OFFICER

STATION

OPEN WAITING -

TRANSPORT - MALE

STAIR 1

ROOF HATCH

ACCESS /

STORAGE

PRE-ADMINISSION

GROUP

HOLDING CELL

(10)

JANITOR

CLOSET

JAIL OFFICE

STATION

G-

G-

INTERVIEW

ROOM

G-

INTERVIEW

ROOM

G-

G-

M

G-028G-

G-

G-051

G-055

2 2 2

G-

G-070 G-071

2 2 2 2 2 2 2

JAIL OFFICE

STATION

KEY WATCHER

SYSTEM

LOCATION

BREATHALYZER

ROOM

2 2

TV

TV

TV

TV

TV

TV

2 2

PH

PH

TV

TV

TV

TV

TV

CAMERA BY

FOOD VENDOR

G-129

G-13

G-13

G-132

G-13

DN

UPUP

UP

M M M

TV

TV

ZC+M

ALT#1

ZC+M

ALT#1

ZC+M

ALT#1

ZC+M

ALT#1

ZC+M

ALT#1

ZC+S

ALT#1

ZC+S

ALT#1

ZC+S

ALT#1

CAMERA/MIC

BY iRECORD

CAMERA/MIC

BY iRECORD

CAMERA/MIC

BY iRECORD

T1.06 2A

TECHNOLOGY FLOOR PLAN - GROUND LEVEL AREA 'B'

SCALE: 1/8" = 1'-0"

N

T1.01B

T1.01B

Owner

Project Name

Revisions

Drawn By

Checked By

Approved By

Sheet No.

Sheet Name

Project No.

KW

KW

KW

Issued

TECHNOLOGY

FLOOR PLAN -

GROUND LEVEL

AREA 'B'

25-T01 / MC 31-25

Macomb County 1 South Main St.

Mount Clemens, MI 48043

Macomb County Sheriff's Office 43565 Elizabeth Rd.

Mount Clemens, MI 48043

Key Plan

Bidding - Construction 06.12.2025

B A

CIAC BLDG

EXTG BLDG

59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS

AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.

2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES

AND REGULATIONS.

3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH

MANUFACTURER'S REGULATIONS.

4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND

FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL

DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER

NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE

CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE

CONSIDERED AS GROUNDS FOR AN EXTRA.

5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND

SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE

PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO

ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.

6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.

7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE

ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.

8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.

9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE

ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START

OF WORK.

10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,

ROOF, AND FIRE RATED WALLS.

11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS

THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.

12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR

SHEET.

13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN

LOCATIONS WITH CABLE TRAY.

14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A

MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE

BOX TO MEET ACOUSTICAL REQUIREMENTS.

15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE

SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS

CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.

16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS

REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY

PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.

17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY

OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.

18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL

INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING

AGENCY OF THE PERMIT.

19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR

THE SYSTEM THEY ARE ASSOCIATED WITH.

20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE

PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID

PACKAGE.

21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS

NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL

NOT EXCEED 40% FULL CAPACITY.

22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR

SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF

THIS PROJECT.

23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF

THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.

DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE

WRITTEN APPROVAL.

Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01

LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN

FUTURE TECHNOLOGY BID PACKAGE.

1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC

CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION

271300.

TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE

FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT

LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.

LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE

FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO

SPECIFICATION SECTION 271100.

TECHNOLOGY FLOOR PLAN KEYNOTES:

"X"

INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY

CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"

DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR

TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,

JUNCTION BOXES, ETC.)

INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR

BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A

TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL

CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.)

"X"

INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

AP

SYMBOL DESCRIPTION

TECHNOLOGY FLOOR PLAN LEGEND:

INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

X-000

ETR

INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO

REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.

X-000

"X"

INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT

(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND

INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING

INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)

TV

INDICATES LOCATION OF NEW EXTERNAL MICROPHONE TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. NO WORK REQUIRED IN THIS BID PACKAGE.M

LOCATION OF VIDEO VISITATION UNIT (BY OTHERS). ELECTRICAL

CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,

JUNCTION BOXES, ETC.).

VCCP

ZC+M

ZC+S

ALT#1

ALT#1

ALT#1

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER CONTROL

PANEL LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL TWO (2) DATA DROPS THIS LOCATION. VERIFY EXACT

LOCATION PRIOR TO INSTALLATION.

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ MAIN

MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE VCCP

IN THE LOCAL MDF/IDF. TECHNOLOGY CONTRACTOR SHALL

FURNISH AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+M

LOCATION TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE

RUN FOR BIDDING PURPOSES).

PROPOSAL T-01, ALTERNATE #1 - VACUUM CENTER ZC+ SUB

MODULE LOCATION. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

NEAREST ZC+M. TECHNOLOGY CONTRACTOR SHALL FURNISH

AND INSTALL FOUR (4) CAT6 CABLES FROM THE ZC+S LOCATION

TO NEARBY EPI/STATIONS (ASSUME 25' EACH CABLE RUN FOR

BIDDING PURPOSES).

8 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL AN ELEVATOR DEVICE

JUNCTION BOX FOR INTERFACE OF ELEVATOR DEVICES TO BE LOCATED

3 4

2-047

2-0502-044

2-049

2-051

2-074

2-073

2-075

2-0

2-091

2-090

2-092

2-071

2-

2-094

2-096

2-095

2-

2-072

2-064

2-069

2-048

AP AP

AP

AP

AP

AP

FIRST FLOOR ROOF

FIRST FLOOR ROOF

STAIR 2

STAIR 3

COURTYARD

EL

EV

. N o

EL

EV

. N o

EL

EV

. N o

EL

EV

. N o

SHARED

TABLET

CHARGING &

STORAGE

SHARED

PROPERTY

STORAGE AND

LAUNDRY

CART

STORAGE

INTERVIEW

ROOM

CALMING

ROOM

STORAGE

ROOM

SAFETY CELL

CALMING

ROOM

INTERVIEW

ROOM

ADA SHOWER/

CHANGING

SHOWER/

CHANGING

SHOWER/

CHANGING

SHOWER/

CHANGING

ADA SHOWER/

CHANGING

EXAM ROOM

GENERAL

EXAM ROOM

GENERAL

SHOWER/

CHANGING

STORAGE

SINGLE ROOM

ADA SINGLE

SINGLE ROOM

FRESH AIR

COURT

ADA SINGLE

ROOM

SINGLE ROOM

ADA SHOWER

SINGLE ROOM

SINGLE ROOM

SINGLE ROOM

SINGLE ROOM

SINGLE ROOM

SINGLE ROOM

ADA SINGLE

ROOM -

BARIATRIC

FRESH AIR

COURT

SINGLE ROOM

MEDICATION

ROOM

MEDICATION

STORAGE

ROOM

SALLYPORT

HOUSING POD

PEDESTRAIN

SALLYPORT

SHARED

SUPPLY

STORAGE

ROOM

DOUBLE ROOM

CIRCULATION

NURSE/OFFICER

WORKSTATION

CIRCULATION

DOUBLE ROOM

DOUBLE ROOM

DOUBLE ROOM

DOUBLE ROOM

ADA DOUBLE

ROOM

DOUBLE ROOM

DOUBLE ROOM

DOUBLE ROOM

DOUBLE ROOM

D0UBLE

OCCUPANCY

ROOM

ELECTRICAL

ELECTRICAL

IDF-2

NURSE/OFFICER

WORKSTATION

MECH. SHAFT

MECH. SHAFT

SHARED VIDEO

ARRAIGMENT

BOOTHS

FP CLOSET

DOUBLE ROOM

DAYROOM /

DINING / TV

FOOD &

BEVERAGE

STATION

JANITOR

CLOSET

OFFICER

WORKROOM

OFFICER

WORKROOM

RESTROOM -

STAFF

RESTROOM -

STAFF

NURSE/OFFICER

WORKSTATION

ELEVATOR

LOBBY

ADA SINGLE

ROOM -

BARIATRIC

SINGLE ROOM

ELECTRONICS

STORAGE /

REACHING

ELEVATOR

CORRIDOR

DAYROOM /

DINING / TV

ADA

MULTIFUNCTIONING

WATER

COOLER FOOD &

BEVERAGE

STATION

MULTIFUNCTIONAL

KIOSK

DAYROOM /

DINING / TV

ADA

MULTIFUNCTIONING

MULTIFUNCTIONAL

KIOSK

STAFF

RESTROOM

STAFF

RESTROOM

CORRIDOR

MECH. SHAFT

MECH. SHAFT

MECH. SHAFT

FIRE

SPRINKLERS

PIPE SHAFT

ADA SINGLE

ROOM -

BARIATRIC

SINGLE ROOM

MALE ACUTE 2

9 BED

(7 SINGLE, 2 ADA

BARIATRIC)

1 ADA SHOWER + 1

SHOWER

1 FRESH AIR COURT

MALE ACUTE 1

HIGH OBSERVATION

7 BED

(6 SINGLE, 1 ADA

BARIATRIC)

1 ADA SHOWER

1 FRESH AIR COURT

MALE SUBACUTE

27 BED

3 SHOWER + 1 ADA

SHOWER

SINGLE ROOM

SINGLE ROOM

MULTI

PURPOSE

ROOM

MULTI

PURPOSE

ROOM

2 2

2-046

2-045

TV TV

2-

2-

2-076

2-088

2-

AREA AAREA B

AREA AAREA B

2-052

2-053

2-054

2-055

2-056

2-103

SINGLE ROOM

2-057

2-058

2-059

2-060 2-062

2-063

2-065

2-067

2-068

2-070

2 PH

TV

TV

VV

TV

VV

PH

TV

2-105 2-1

2-102

2-1

UPUP

UP

TV

VCCP

ALT#1

ZC+M

ALT#1

ZC+M

ALT#1

ZC+S

ALT#1

ZC+S

ALT#1

ZC+M

ALT#1

ZC+S

ALT#1

ZC+S

ALT#1

ZC+M

ALT#1

ZC+M

ALT#1

ZC+S

ALT#1

ZC+S

ALT#1

ZC+S

ALT#1

ZC+S

ALT#1

ZC+M

ALT#1

ZC+S

ALT#1

T1.06

TECHNOLOGY FLOOR PLAN - 2nd FLOOR AREA 'A'

SCALE: 1/8" = 1'-0"

N

T1.02A

T1.02A

Owner

Project Name

Revisions

Drawn By

Checked By

Approved By

Sheet No.

Sheet Name

Project No.

KW

KW

KW

Issued

TECHNOLOGY

FLOOR PLAN -

2ND FLOOR

AREA 'A'

25-T01 / MC 31-25

Macomb County 1 South Main St.

Mount Clemens, MI 48043

Macomb County Sheriff's Office 43565 Elizabeth Rd.

Mount Clemens, MI 48043

Key Plan

Bidding - Construction 06.12.2025

B A

CIAC BLDG

EXTG BLDG

59 North Walnut Street, Suite 202 Mount Clemens, MI 48043 Office: (586) 203-8423 Fax: (586) 203-8930 www.MetroTechnologyServices.com

GENERAL TECHNOLOGY NOTES:

1. THESE DRAWINGS REPRESENT THE GENERAL EXTENT AND ARRANGEMENT OF SYSTEMS

AND ARE NOT TO BE CONSIDERED FABRICATION DRAWINGS.

2. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES, ORDINANCES

AND REGULATIONS.

3. ALL MATERIALS SHALL BE INSTALLED/APPLIED IN STRICT ACCORDANCE WITH

MANUFACTURER'S REGULATIONS.

4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VISITING THE JOB SITE AND

FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS PRIOR TO START OF WORK. ALL

DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED, AND CONSTRUCTION MANAGER

NOTIFIED OF ANY DISCREPANCIES PRIOR TO THE RECEIPT OF BIDS. FAILURE OF THE

CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO THE AWARD OF BID WILL NOT BE

CONSIDERED AS GROUNDS FOR AN EXTRA.

5. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR INITIATING, MAINTAINING, AND

SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE

PERFORMANCE OF THE CONTRACT. PROVIDE ALL NECESSARY TEMPORARY PROTECTION TO

ENSURE THE SAFETY OF THE GENERAL PUBLIC DURING CONSTRUCTION.

6. ALL ITEMS SHALL BE AS SPECIFIED BY ARCHITECT/TECHNOLOGY DESIGNER.

7. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO THE

ARCHITECT/TECHNOLOGY DESIGNER FOR REVIEW PRIOR TO INSTALLATION/APPLICATION.

8. ALL DEBRIS SHALL BE LEGALLY DISPOSED OF OFF THE SITE BY THE CONTRACTOR.

9. CONTRACTOR SHALL COORDINATE INSTALLATION AND PHASING OF WORK WITH THE

ARCHITECT/TECHNOLOGY DESIGNER AND OWNER'S REPRESENTATIVE PRIOR TO THE START

OF WORK.

10. CONTRACTOR SHALL FIRE SEAL AROUND ALL NEW CONDUITS PENETRATING FLOORS,

ROOF, AND FIRE RATED WALLS.

11. ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTS

THROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.

12. SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR

SHEET.

13. UTILIZE CABLE TRAY AND CONDUIT RACEWAYS/PATHWAYS WHENEVER POSSIBLE IN

LOCATIONS WITH CABLE TRAY.

14. ALL OUTLETS AND DEVICES MOUNTED BACK TO BACK IN WALL MUST BE SPACED A

MINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE

BOX TO MEET ACOUSTICAL REQUIREMENTS.

15. ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF IN THE

SAME BUILDING AREA (UNLESS NOTED OTHERWISE). COPPER TELECOMMUNICATIONS

CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH.

16. FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS

REQUIRED FOR ROUTING OF CONDUIT. PROVIDE SURFACE-MOUNTED METAL RACEWAY

PAINTED TO MATCH ADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.

17. ALL WORK SHALL BE DONE IN A MANNER TO MINIMIZE THE IMPACT ON DAILY

OPERATIONS. COORDINATE WITH THE OWNER FOR BEST WORK TIME TO ACCESS SPACES.

18. EACH BUILDING SITE REQUIRES ITS OWN ELECTRICAL PERMIT AND SHALL HAVE A FINAL

INSPECTION AT THE TIME OF COMPLETION OF WORK ON THE BUILDING BY THE ISSUING

AGENCY OF THE PERMIT.

19. ALL TELECOMMUNICATIONS JACKS SHALL MATCH THE COLOR OF THE CABLING FOR

THE SYSTEM THEY ARE ASSOCIATED WITH.

20. CONTRACTORS SHALL PROVIDE CURRENT PROOF OF CERTIFICATION LEVEL FOR THE

PRODUCT LINE THEY ARE USING ON THE PROJECT AT THE TIME OF BID WITH THE BID

PACKAGE.

21. PROVIDE ALL RACEWAYS AS REQUIRED, AND ADDITIONAL CONDUIT SLEEVES AS

NEEDED INTO MDF AND IDF LOCATIONS. EXISTING PATHWAYS MAY BE UTILIZED BUT SHALL

NOT EXCEED 40% FULL CAPACITY.

22. SOME LOCATIONS MAY REQUIRE A LIFT OR OTHER MEANS TO ACCESS. CONTRACTOR

SHALL BE RESPONSIBLE FOR PROVIDING ALL ACCESS REQUIRED FOR THE ENTIRETY OF

THIS PROJECT.

23. THERE SHALL BE NO NETWORK OR SYSTEMS DOWNTIME DURING THE DURATION OF

THIS PROJECT WITHOUT COORDINATION WITH AND APPROVAL OF THE OWNER.

DOWNTIMES SHALL BE OUTSIDE OF OWNER'S OPERATING HOURS AND SHALL REQUIRE

WRITTEN APPROVAL.

Macomb County Central Intake & Assessment Center / Jail Renovations Tech Bid Package 25-T01

LOCATION OF MONITOR TO BE FURNISHED AND INSTALLED BY OTHERS IN

FUTURE TECHNOLOGY BID PACKAGE.

1 TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW FIBER OPTIC

CABLING (12 STRANDS) FROM THIS LOCATION TO "MDF" IN LOWER LEVEL.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.). REFER TO SPECIFICATION SECTION

271300.

TECHNOLOGY CONTRACTOR TO FURNISH AND INSTALL NEW HDMI CABLE

FROM MONITOR LOCATION TO FLOOR BOX. ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

6 LOCATION OF INMATE PHONE (BY OTHERS). ELECTRICAL CONTRACTOR TO

PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.).

7 DATA DROP FOR FIRE ALARM CONTROL PANEL. COORDINATE EXACT

LOCATION WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.

LOCATION OF FLOOR-MOUNTED, 4-POST, LOCKABLE IT CABINET TO BE

FURNISHED AND INSTALLED BY TECHNOLOGY CONTRACTOR. REFER TO

SPECIFICATION SECTION 271100.

TECHNOLOGY FLOOR PLAN KEYNOTES:

"X"

INDICATES LOCATION OF NEW DATA DROP. TECHNOLOGY

CONTRACTOR SHALL FURNISH AND INSTALL A TOTAL OF "X"

DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL CONTRACTOR

TO PROVIDE ALL SUPPORTING INFRASTRUCTURE (CONDUITS,

JUNCTION BOXES, ETC.)

INDICATES LOCATION OF NEW DATA DROP LOCATED IN FLOOR

BOX. TECHNOLOGY CONTRACTOR SHALL FURNISH AND INSTALL A

TOTAL "X" DROPS AT EACH OF THESE LOCATIONS. ELECTRICAL

CONTRACTOR TO PROVIDE ALL SUPPORTING INFRASTRUCTURE

(CONDUITS, JUNCTION BOXES, ETC.)

"X"

INDICATES LOCATION OF NEW SURVEILLANCE CAMERA TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

AP

SYMBOL DESCRIPTION

TECHNOLOGY FLOOR PLAN LEGEND:

INDICATES LOCATION OF NEW WIRELESS ACCESS POINT TO BE

FURNISHED AND INSTALLED BY OTHERS IN FUTURE TECHNOLOGY

BID PACKAGE. TECHNOLOGY CONTRACTOR TO FURNISH AND

INSTALL ONE (1) CAT6 CABLE FROM THIS LOCATION TO THE

LOCAL MDF/IDF. ELECTRICAL CONTRACTOR TO PROVIDE ALL

SUPPORTING INFRASTRUCTURE (CONDUITS, JUNCTION BOXES,

ETC.)

X-000

ETR

INDICATES LOCATION OF EXISTING SURVEILLANCE CAMERA TO

REMAIN. NO WORK REQUIRED IN THIS BID PACKAGE.

X-000

"X"

INDICATES LOCATION OF NEW DATA DROP AT MONITOR HEIGHT

(VARIES). TECHNOLOGY CONTRACTOR SHALL FURNISH AND

INSTALL A TOTAL OF "X" DROPS AT EACH OF THESE LOCATIONS.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SUPPORTING

INFRASTRUCTURE (CONDUITS, JUNCTION BOXES, ETC.)

TV

INDICATES LOCATION OF NEW EXTERNAL MICROPHONE TO BE

This is the start of the file's text. The full file is on GovTribe.