Requirements Document Final.pdf
PDF 277 KB Posted
- Attached to
- Electrical Calibration Federal contract opportunity
- Solicitation number
- 1333ND23QNB730465
About this file
This requirements document outlines the need for a benchtop multi-product calibrator and transconductance amplifier to support electrical calibration activities at the National Institute of Standards and Technology. The calibrator must be able to generate DC voltages from 0-1020V and currents from 0-30A, as well as AC voltages up to 1100V at 3Hz-500kHz and currents up to 30A at 3Hz-30kHz. The transconductance amplifier must generate DC currents from 0-100A and AC currents from 0-120A at 1Hz-10kHz, with 150ppm accuracy for both DC and AC outputs. Delivery of both items is due within 90 days of award. Testing, inspection, and acceptance of the equipment will be completed by NIST within 60 working days of receipt. The contractor shall provide a one year warranty on all equipment. Payment terms are net 30 days upon acceptance of invoices.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions and Answers .docx | DOCX document | |
| Applicable Provisions and Clauses Final .pdf | ||
| Combined Solicitation Synopsis_Final.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUIREMENTS DOCUMENT
Title: Electrical Calibration
Requesting Lab: Engineering Laboratory
I. BACKGROUND INFORMATION
The Mechanical Systems & Controls Group at the National Institute of Standards and
Technology (NIST) expands the scientific knowledge of building operation and integration with the smart electric grid. The group’s focus is to improve energy efficiency of building equipment through measurement, control strategies, and technical insight related to grid stability, power quality, integration of distributed renewable energy resources, and provision of ancillary services. The research activities include power system monitoring, simulation, and data analysis.
To fulfill its mission, the Mechanical Systems & Controls Group requires calibration equipment to characterize the electrical performances of voltage and current sensors, and power meters. The calibration equipment will be used to quantify the measurement uncertainty, frequency response, and gain of various voltage and current sensors, and power meters. The calibration equipment purchase supports the objectives of the Electrical Performance of Grid-Interactive Efficient
Buildings (EPGEB) and collaboration work with the Office of Facility and Property
Management. A key component of measurement science to support EPGEB is collecting high-quality data such as high-frequency voltage and current waveforms, and electrical power and energy consumption data. Collecting high-quality data needs accurate instrumentations that require frequent calibration and spot checking. The impact of this invested equipment is not limited to the EPGEB project, it will allow other researchers in Division 732 to calibrate various electrical measurement equipment to advance their project requirements.
Purpose/Objective:
The objective of the requirement is to calibrate various electrical measurement instruments.
More specifically, the objective is to quantify the measurement uncertainty, frequency response, and gain of electrical measurement equipment.
II. SCOPE
The Contractor shall deliver one (1) programmable and low noise benchtop multi-product calibrator and one (1) transconductance amplifier, including all required cables, connectors, warranty, training, and accredited calibration. The transconductance amplifier shall be compatible with parallel operation with other transconductance amplifiers or other mechanisms such as turn-coil to extend the range of current output. The delivery shall be made to the NIST in
Gaithersburg campus in MD in accordance with the provided delivery schedule. The calibrator and the transconductance amplifier shall also be compatible with each other. The specifications criteria for the Multi-Product Calibrator and the Transconductance Amplifier are shown in the
Minimum Requirements section.
III. MINIMUM REQUIREMENTS
The Contractor shall provide a system that meets all technical specifications identified below. All items must be new. Used or remanufactured equipment will not be considered for award.
Experimental, prototype, or custom items will not be considered. The use of “gray market” components are not authorized for sale in the U.S. by the Contractor is not acceptable. All line items shall be shipped in the original manufacturer’s packaging and include all original documentation and software, when applicable.
Line Item 0001: Benchtop Multi-Product Calibrator
Description: A benchtop multi-product calibrator is programmable source equipment for calibrating electrical and temperature measurement equipment and sensors.
Quantity: 1
A. Technical Specifications
a. DC voltage: 0 V to ± 1020 V or better,
b. DC current: 0 A to ± 30 A or better,
c. AC voltage: up to 1100 V at 3 Hz – 500 kHz or better,
d. AC current: up to 30 A or better at 3 Hz – 30 kHz or better,
e. Volt/hertz: at least 100 kHz at 120 V and 240 V,
f. Resistance: discrete values from 1 Ω to 1000 MΩ or better,
g. AC waveforms: sine wave, square wave, triangle wave, and truncated sine wave.
Sine waves up to 1 MHz or better,
h. Communication: IEEE-488, USB 2.0 or higher for remote control applications, USB host port for saving calibration data to an external hard drive and firmware updates, ethernet 10/100/1000Base-T, and RS-232,
i. External frequency reference input: up to 10 MHz or better,
j. WBGA color display with touch-screen functionality, and
k. Harmonic waveform signals up to 50th order or higher.
Line Item 0002: Transconductance Amplifier
Description: A transconductance amplifier is a high-accuracy and low noise programmable current source. The transconductance amplifier extends the benchtop multi-product calibrator’s functionality to generate higher current values greater than 120 A AC.
Quantity: 1
B. Technical Specifications
a. DC current with different range selection capability: 0 A to 100 A or better,
b. AC current with different range selection capability: 0 A to 120 A or better at frequencies 1 Hz - 10 kHz or better,
c. DC Accuracy: 150 ppm or better,
d. AC Accuracy: 150 ppm or better,
e. Compatible for parallel output connection,
f. Output connectors: standard RS 100G, and
g. Communication: IEEE-488, USB 2.0 or higher, or Ethernet.
IV. DELIVERABLES
Description Quantity or Format Due Date
Benchtop Multi-Product
Calibrator
90 days ADC
120 A Transconductance
Amplifier as a current source
90 days ADC
Standards of Acceptance: The NIST COR shall review (list deliverable) and respond with an acceptance or request for revision email to the Contractor Point of Contact (POC) within 14 days of receipt of deliverable. This section applies to deliverables which must be reviewed and approved for acceptances (draft plans, drawings, etc.)
V. DELIVERY TERMS
Delivery shall be F.O.B Destination and shall occur in accordance with the delivery due dates provided in the above table.
FOB Destination means: The contractor shall pack and mark the shipment in conformance with carrier requirements, deliver the shipment in good order and condition to the point of delivery specified in the purchase order, be responsible for any loss of and/or damage to the goods occurring before receipt and acceptance of the shipment by the consignee at the delivery point specified in the purchase order; and pay all charges to the specified point of delivery. The contractor shall deliver all Line Items to:
National Institute of Standards and Technology
Shipping and Receiving
100 Bureau Drive, Building 301
Gaithersburg, MD 20899
VI. INSPECTION & ACCEPTANCE
In addition to the inspection and acceptance terms articulated in 52.212-4, the Government reserves the right to perform such performance tests and evaluations as defined below to verify specified system performance. Such tests and evaluations, if performed, shall be conducted within the environment that the system is to be operated. The Contractor has the right to be present during the tests and evaluations, if performed, at the Contractor’s expense.
Performance Tests:
1. Operate and test the equipment in accordance with the minimum requirement specifications provided for the line items listed above.
NIST may choose at its discretion to forego this part of acceptance testing.
A visual inspection of the equipment will be performed by the NIST COR to identify surface defects or any form of indication that any equipment was damaged during transport to NIST. The Government shall have sole discretion to require repair or replacement of damaged and/or nonconforming supplies at no cost to the
Government. The Government at any time prior to acceptance shall reject the equipment due to defects and/or nonconformance. The contractor is responsible for latent defects discovered any time after final inspection. However, the extent of its liability shall be prorated over the useful life of the equipment.
Ownership of the equipment shall transfer to NIST upon acceptance by the
Government.
The Government will test, inspect, and accept or reject the equipment within (60 working days it will take to inspect, accept or reject) of the receipt of the equipment unless otherwise indicated above. The Government reserves the right to conduct quality assurance testing to confirm that a given instrument(s) meets the manufacturer’s and/or the Government’s performance specifications. It is anticipated that the equipment will meet all manufacturer’s specifications and/or the
Government’s performance specifications identified in the most recent operations and maintenance manual for each piece of equipment and/or in this document.
VII. WARRANTY
The contractor shall warranty the entire system for a period of a minimum of (1 year or standard warranty if greater than 1 year) after receipt of the equipment and shall be in accordance with terms in FAR 52.212-4. Warranty shall commence upon acceptance of the system by the
Government.
VIII. PAYMENT SCHEDULE
Advance payment is not authorized. The Contractor must invoice in arrears according to the payment schedule. The Contractor shall be paid, in accordance with Net 30-day payment terms, upon receipt and acceptance of a proper invoice, in accordance with the following schedule:
After acceptance by the COR.
NOTE: Partial shipments and partial invoices will not be accepted, unless otherwise requested and accepted by the Contracting Officer prior to award offer. Proposed payment schedules shall be submitted with vendor’s response to the RFQ for consideration.
File details come from the government source that posted it. Updated .