Remanufacture three (3) 37.5 KVA Single Phase Pad Mount KVA: 37.5 @ 65°C | 60Hz | Impedance: Standard HV: 4160GrdY/2400 (60 KV BIL) | Loop Feed | LV: 240/120 (30 KV BIL) Primary Taps: 2-2.5% FCAN & BN 15 KV Wells Only, Dead Front FR3 Insulating Fluid 4-Hole Spade LV Bushing, Matched Bank 0000000007

Remanufacture ten (10) 25 KVA Single Phase Pad Mount KVA: 25 @ 65°C | 60Hz | Impedance: Standard HV: 4160GrdY/2400 (60 KV BIL) | Loop Feed | LV: 240/120 (30 KV BIL) Primary Taps: 2-2.5% FCAN & BN 15 KV Wells Only, Dead Front FR3 Insulating Fluid 4-Hole Spade LV Bushing

Remanufacture three (3) 37.5 KVA Single Phase Pad Mount KVA: 37.5 @ 65°C | 60Hz | Impedance: Standard HV: 4160GrdY/2400 (60 KV BIL) | Loop Feed | LV: 480Y/277 (30 KV BIL) Primary Taps: 2-2.5% FCAN & BN 15 KV Wells Only, Dead Front FR3 Insulating Fluid 4-Hole Spade LV Bushing, Matched Bank

Remanufacture one (1) 75 KVA Three Phase Pad Mount KVA: 75 @ 65°C | 60Hz | Impedance: Standard HV: 13800GrdY/7970 (95 KV BIL) | Loop Feed | LV: 208Y/120 (30 KV BIL) Primary Taps: 2-2.5% FCAN & BN Bayonet Fusing w/Drip Shield 15 KV Wells Only, Dead Front Non-PCB Mineral Oil Liquid Temperature Gauge Liquid Level Gauge Pressure Vacuum Gauge, PRV Drain Valve + Sampler

Remanufactured 225 KVA Three Phase Pad Mount KVA: 225 @ 65°C | 60Hz | Impedance: Standard HV: 4160GrdY/2400 (95 KV BIL) | Loop Feed | LV: 208Y/120 (30 KV BIL) Primary Taps: 2-2.5% FCAN & BN Bayonet Fusing w/Drip Shield 15 KV Wells Only, Dead Front Non-PCB Mineral Oil Liquid Temperature Gauge Liquid Level Gauge Pressure Vacuum Gauge, PRV Drain Valve + Sampler

REWIND Sixteen (16) 15 KVA Single Phase Pad Mount KVA: 15 @ 65°C | 60Hz | Impedance: Standard HV: 4160GrdY/2400 (60 KV BIL) | Loop Feed | LV: 240/120 (30 KV BIL) Primary Taps: 2-2.5% FCAN & BN 15 KV Wells Only, Dead Front FR3 Insulating Fluid