Form 430126 (Revised 82114 jsb) Date:___________

LS1LS3 PILOT EXCITER WINDING TEST DATA

W.O.:___________

P.O.:___________

Contractor & Job#:___________

UNIT LS1LS3

PILOT EXCITER WINDING TEST DATA

UNIT: _______________

Insulation Resistance (meggared). Test Instrument Voltage: ____________________

BRUSHES REMOVED: As Found After Cleaning As Left

Rotor (armature) Coils and Comm. to shaft ......………………______ Megohms ______ Megohms ______Megohms

Stator (fields) Interpole Coils & Brush arms to frame (A3) Shunt Field disconnected….……….....______ Megohms ______ Megohms ______Megohms

Brush arms to frame (A4)………….…….. ______ Megohms ______ Megohms ______Megohms

Shunt (F5 & F6) to frame..... ....................... ______ Megohms ______ Megohms ______Megohms

ARMATURE COILS AFTER CLEANING:

Ductor: Attach separate sheet with ductor readings.

Surge Comparison/Baker AWATests: Attach separate sheet with photographs and/or report, and a narrative of test results.

FIELD COILS

As Found (Incoming)

AC & DC VOLTAGE DROP TESTS

Interpoles, __10___ Amps @ ______ VAC

Volts/pole = ______ ______

Total = ______ VAC

Interpoles, __10___ Amps @ ______ VDC

Volts/pole = ______ ______

Total = ______ VDC

Pole No’s. __1___ __2___ __3___ __4___ (See exciter wiring diagram for pole numbers/locations)

Shunt (F5 F6) ______ Amps @ _250__ VAC

Volts/pole = ______ ______ ______ ______

Total = ______ VAC

Shunt (F5 F6) ______ Amps @ _250__ VDC

Volts/pole = ______ ______ ______ ______

Total = ______ VDC

As Found (After Cleaning)

AC & DC VOLTAGE DROP TESTS

Interpoles, __10___ Amps @ ______ VAC

Volts/pole = ______ ______

Total = ______ VAC

Interpoles, __10___ Amps @ ______ VDC

Volts/pole = ______ ______

Total = ______ VDC

Pole No’s. __1___ __2___ __3___ __4___ (See exciter wiring diagram for pole numbers/locations)

Shunt (F5 F6) ______ Amps @ _250__ VAC

Volts/pole = ______ ______ ______ ______

Total = ______ VAC

Shunt (F5 F6) ______ Amps @ _250__ VDC

Volts/pole = ______ ______ ______ ______

Total = ______ VDC

As Found (As Left)

AC & DC VOLTAGE DROP TESTS

Interpoles, __10___ Amps @ ______ VAC

Volts/pole = ______ ______

Total = ______ VAC

Interpoles, __10___ Amps @ ______ VDC

Volts/pole = ______ ______

Total = ______ VDC

Pole No’s. __1___ __2___ __3___ __4___ (See exciter wiring diagram for pole numbers/locations)

Shunt (F5 F6) ______ Amps @ _250__ VAC

Volts/pole = ______ ______ ______ ______

Total = ______ VAC

Shunt (F5 F6) ______ Amps @ _250__ VDC

Volts/pole = ______ ______ ______ ______

Total = ______ VDC

DC RESISTANCE READINGS

Shunt (F5 F6) ______ Ohms

PERFORM OTHER CONTRACTOR STANDARD INSPECTIONS AND TESTS, AND DOCUMENT ON CONTRACTOR

STANDARD FORMS.

REMARKS: