Form 430126 (Revised 82114 jsb) Date:___________
LS1LS3 PILOT EXCITER WINDING TEST DATA
W.O.:___________
P.O.:___________
Contractor & Job#:___________
UNIT LS1LS3
PILOT EXCITER WINDING TEST DATA
UNIT: _______________
Insulation Resistance (meggared). Test Instrument Voltage: ____________________
BRUSHES REMOVED: As Found After Cleaning As Left
Rotor (armature) Coils and Comm. to shaft ......………………______ Megohms ______ Megohms ______Megohms
Stator (fields) Interpole Coils & Brush arms to frame (A3) Shunt Field disconnected….……….....______ Megohms ______ Megohms ______Megohms
Brush arms to frame (A4)………….…….. ______ Megohms ______ Megohms ______Megohms
Shunt (F5 & F6) to frame..... ....................... ______ Megohms ______ Megohms ______Megohms
ARMATURE COILS AFTER CLEANING:
Ductor: Attach separate sheet with ductor readings.
Surge Comparison/Baker AWATests: Attach separate sheet with photographs and/or report, and a narrative of test results.
FIELD COILS
As Found (Incoming)
AC & DC VOLTAGE DROP TESTS
Interpoles, __10___ Amps @ ______ VAC
Volts/pole = ______ ______
Total = ______ VAC
Interpoles, __10___ Amps @ ______ VDC
Volts/pole = ______ ______
Total = ______ VDC
Pole No’s. __1___ __2___ __3___ __4___ (See exciter wiring diagram for pole numbers/locations)
Shunt (F5 F6) ______ Amps @ _250__ VAC
Volts/pole = ______ ______ ______ ______
Total = ______ VAC
Shunt (F5 F6) ______ Amps @ _250__ VDC
Volts/pole = ______ ______ ______ ______
Total = ______ VDC
As Found (After Cleaning)
AC & DC VOLTAGE DROP TESTS
Interpoles, __10___ Amps @ ______ VAC
Volts/pole = ______ ______
Total = ______ VAC
Interpoles, __10___ Amps @ ______ VDC
Volts/pole = ______ ______
Total = ______ VDC
Pole No’s. __1___ __2___ __3___ __4___ (See exciter wiring diagram for pole numbers/locations)
Shunt (F5 F6) ______ Amps @ _250__ VAC
Volts/pole = ______ ______ ______ ______
Total = ______ VAC
Shunt (F5 F6) ______ Amps @ _250__ VDC
Volts/pole = ______ ______ ______ ______
Total = ______ VDC
As Found (As Left)
AC & DC VOLTAGE DROP TESTS
Interpoles, __10___ Amps @ ______ VAC
Volts/pole = ______ ______
Total = ______ VAC
Interpoles, __10___ Amps @ ______ VDC
Volts/pole = ______ ______
Total = ______ VDC
Pole No’s. __1___ __2___ __3___ __4___ (See exciter wiring diagram for pole numbers/locations)
Shunt (F5 F6) ______ Amps @ _250__ VAC
Volts/pole = ______ ______ ______ ______
Total = ______ VAC
Shunt (F5 F6) ______ Amps @ _250__ VDC
Volts/pole = ______ ______ ______ ______
Total = ______ VDC
DC RESISTANCE READINGS
Shunt (F5 F6) ______ Ohms
PERFORM OTHER CONTRACTOR STANDARD INSPECTIONS AND TESTS, AND DOCUMENT ON CONTRACTOR
STANDARD FORMS.
REMARKS: