03_SOW_IP_Phone_Systems.pdf

PDF 121 KB Posted

Attached to
IP PHONE SYSTEMS - CURECANTI SITES Federal contract opportunity
Solicitation number
R15PS00221
Issued by
Department of the Interior Bureau of Reclamation

About this file

SOW IP Phones for Curecanti Sites

View the file

Other files for this federal contract opportunity

Other files attached to IP PHONE SYSTEMS - CURECANTI SITES, newest first.
File Type Posted
Sol_R15PS00221_Amd_000005.pdf PDF
Sol_R15PS00221_Amd_000004.pdf PDF
Sol_R15PS00221_Amd_000003.pdf PDF
Sol_R15PS00221_Amd_000001.pdf PDF
14_Wage_Determinatin_IP_Phones.pdf PDF
06_WBR_1413.106_JOTFOC_IP_Phone_Systems_FINAL_COPY_for_PUBLISHING.pdf PDF
Sol_R15PS00221.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scope of Work Bureau of Reclamation, Curecanti Sites

Internet Protocol (IP) Phone System

SUMMARY

Phase I Replace/upgrade/configure routers for the other Bureau of Reclamation SRST sites as listed below under “Current SRST Site Router Information” and proceed to upgrade/virtualize the Cisco Unified Communications Manager (version 7.13a)/ Cisco Unity Connection (version 7.1.3)(CUCM/CUC) environments to the latest stable CUCM/CUC releases. Cisco UCS platform has already been acquired by Reclamation for this purpose. The vendor shall also implement active directly integration for user administrator and voice mail accounts.

The normal business hours of the Bureau of Reclamation are Monday through Friday 7:00 a.m.

to 5:00 p.m.. All testing, troubleshooting and cutovers need to occur during non-business hours.

The contractor and contractor employees must be escorted by Bureau employees at all times throughout the term of the contract.

Phase II The Bureau of Reclamation, Curecanti Field Division is in need of new telephone system, equipment, and end user units for the Montrose, Colorado office and five field sites. The Bureau of Reclamation currently has a regional Cisco Unified Communications Manager (CUCM) and Unity Connection Systems (UCS) located in our Salt Lake City Office. This scope of work is to outline the requirements to install, configure and test 6 (six) additional Survivable Remote Site Telephony (SRST) in the following locations:

Montrose Office 1820 South Rio Grande Montrose, CO 81401-4859

Crystal Dam and Power Plant 78501 East Portal Road Montrose, CO 81401 GPS Coordinates: 38°30′38.48″N 107°37′30.60″W

Morrow Point Dam and Power Plant 82849 Q83 Road Cimarron, CO 81220 GPS Coordinates: 38°27′07.25″N 107°32′17″W

Blue Mesa Dam and Power Plant 13630 Highway 50 Pine Creek Trail Turnoff Gunnison, CO 81230 GPS Coordinates: 38°27′12″N 107°20′04″W

Lower Molina Power Plant 53758 Highway 330 Molina, CO 81646

Upper Molina Power Plant 5625 KK Road Molina, CO 81646

An integrated solution is desired, if possible, for each site (excluding the Montrose office) to provide a voice gateway router, integrated gigabit network switch and wireless access point. If integrated wireless and/or network switching is not possible for the location, wireless access points and managed switches shall be installed. Gigabit connectivity is required for network switching and the Cisco AIR-CAP 3602i-A-K9 Access Point solution is required. The Bureau of Reclamation, Upper Colorado Region has a managed Cisco Wireless LAN Controller that manages all wireless access for the region. The integration of wireless is not a component of this project, only wireless hardware is requested.

Site Visit A scheduled site visit will be held for the project on January 14-15, 2015. The site visit will take two days to provide sufficient time for the potential vendors to visit all remotes. Interested vendors are encouraged to attend both days in order to better understand the full scope of the project.

SITES

Below is a table for each location identifying the number of IP phones and analog extensions needed with associated estimated cabling length to each analog device. The Bureau of Reclamation will ensure all network cabling and transports are in place and operational prior to installation. All sites shall have a local analog POTS line for SRST, 911 services and 911 calls.

All other voice traffic shall route through a T1PRI at the Montrose, Colorado office.

The vendor shall supply a new telephone for each IP extension listed. Phone models shall meet the following criteria. Vendor shall also provide 3 sidecars for extensions as indicated in the tables below:

All IP phones shall be ENERGY STAR certified All IP phones with Voicemail (w/VM) as indicated in the tables below shall be color screen backlit phones with 5 lines of display and Sidecar capable All other IP phones shall have a minimum LCD 2-line display All phones shall be headset capable (answer via headset function button or via headset) Conference phones shall be IP conference stations with satellite microphones and daisy chain capable All phones shall be equipped with a speakerphone Vendor shall configure and assign voicemail for each extension as requiring voicemail

(w/VM)

Montrose (Voice Gateway Router required):

Location/Label Extension Analog/IP/Optional Notes

Administrative Bld. 6300 IP Administrative Bld. 6301 IP Sidecar Required (BLFSD+Pickup) Warehouse Office 6302 IP

Administrative Bld. 6303 IP Administrative Bld. Fax 6304 Analog

Administrative Bld. 6305 IP Administrative Bld./Main Line

6306 IP Sidecar Required (BLFSD+Pickup)

Warehouse Office 6307 IP Administrative Bld. 6308 IP

Machine Shop 6309 IP Administrative Bld. 6310 IP Administrative Bld. 6311 IP

Warehouse 6312 IP Warehouse 2 6313 IP

Administrative Bld. 6314 IP Warehouse Fax 6315 Analog

Warehouse Office 6316 IP Administrative Bld. 6318 IP Administrative Bld. 6319 IP Administrative Bld. 6320 IP Administrative Bld. 6321 IP Administrative Bld. 6322 IP Warehouse Office 6323 IP

Administrative Bld. 6324 IP Administrative Bld. 6325 IP Administrative Bld. 6326 IP Administrative Bld. 6327 IP Administrative Bld.

Conference Rm

6328 IP

Conference station with satellite microphones required.

DID Range 6300 - 6339

Crystal Dam (Voice Gateway Router, PoE Switching and Wireless Access Point required):

Location/Label Current

Extension Analog/IP/Optional Notes

Approximate Wiring

Distance (Feet)

Telco Number (970) 249-7827 Analog Incoming Telco

Trunk N/A

Entire Plant 0 Group N/A Operators Desk 101* IP w/VM 5 Jet Flow Gates 102* Analog 200

Governor Cabinet 103* Analog 150 Exciter Cabinet 104* Analog 100

Level 1 105* Analog 2 phones, single pair 300 of wire Pipe Gallery 106* Analog 300 Break Room 107* IP 100

Access Structure 108* Analog 600 P. Gate House 109* Analog 600 Comm. Room 110* IP 5 Comm. Room 111* IP 5 Comm. Room 113* IP 5

Mechanic Desk 112* Analog 75 Generator Floor Exit 112* Analog 75

Fax Desk 114* Analog 100 Annex 117* Analog 150

Computer Desk 119* IP 10 Office Computer 122* IP 100 Electrician Desk 123* Analog 100

PSII Desk 124* IP w/VM 100

Morrow Point Dam (Voice Gateway Router, PoE Switching and Wireless Access Point required):

New DIDs ranges will be obtained by Reclamation for this location.

Location/Label Current

Extension Analog/IP/Optional Notes

Approximate Wiring

Distance (Feet)

Telco Number (970) 249-5278 Analog Incoming Telco

Trunk N/A

Cimarron Yard (970) 252-9236 Analog Not tied to phone system N/A

Entire Plant 0* Analog N/A Control Room 101* IP w/VM 20

SCADA Cabinet 102* Analog 20 Office Desk 103* IP 150

Office Portable 104* IP 150 Lunch Room will be

New Office 105* IP w/VM 500

Visitor Center 106* IP 500 Recorder Hut 107* Analog 1000 Switch Yard 108* Analog 2500 Cable Tunnel 109* Analog 400

Heat & Vent Rm 110* Analog 500 Compressor Rm 111* Analog 200

Pump Rm 112* Analog 200 Pipe Gallery 113* Analog 300 Intake Str #1 114* Analog 1000 Intake Str #2 115* Analog 1000 Outlet Gate 116* Analog 1000 Dam-Sump 117* Analog 1000

Gen Floor Door 118* Analog 300 Modem Office 119* Analog 100 PBX Cabinet 120* Analog

Fax Office 121* Analog 300?

Control Room 122* IP 100

Open 123* Analog Exciter #1 124* Analog 200 Exciter #2 125* Analog 300

Gen Breaker 126* Analog 200 Dam Instrument 127* Analog 2000

UPS Cabinet 128* Analog 100 Battery Monitor 129* Analog 100 Relay Computer 130* Analog 100

Blue Mesa (Voice Gateway Router, PoE Switching and Wireless Access Point required):

Location/Label Extension Analog/IP/Optional Notes Approximate

Wiring Distance (Feet)

Telco Number (970) 641-6242 Analog N/A Entire Plant 0 N/A N/A

Control Room 101* IP w/VM 50 Welding Shop 102* Analog 200

Cable Spreading Room 103* Analog 100 Front Door 104* Analog 200

3rd Floor Booth 105* Analog 200 Spillway Gatehouse 106* Analog 2000

Intake Structure 107* Analog 2000 Switchyard 108* Analog 2000

2nd Floor Booth 109* Analog 200 PBX Cabinet 110* Analog 100

New Harris PBX 111* Analog 100 Hollow Jets 112* Analog 600 Jem Meters 113* Analog WAPA SER 114* Analog 100

Supervisor Office 115* Analog 100 Security Auto Dialer 116* Analog

Control Room 117* IP 50 Supervisor Computer 118* IP w/VM 100

Lunchroom East 119* IP 100 Journeyman Office 120* Analog 100 Lunchroom West 121* Analog 100

Exciter #1 122* Analog 100 Exciter #2 123* Analog 150

Site Fax TBD Analog Reclamation will install wiring for new fax line.

TBD

Lower Molina (Voice Gateway Router, PoE Switching and Wireless Access

New DIDs ranges will be obtained by Reclamation for this location.

Location/Label Extension Analog/IP/Optional Notes

Approximate Wiring

Distance (Feet)

Telco Number (970) 487-3348 Analog N/A Office Bldg 1 (970) 487-3348* IP w/VM 50 Office Bldg 2 (970) 487-3348* IP w/VM 50

Office Bldg Shop (970) 487-3348* Analog

Flasher and horn are existing. Flasher and horn shall work when the phone rings.

Control Room (970) 487-3348* IP Fiber needed for IP 200 Fax TBD Analog Need to install TBD

Must dial 9 for outside line

Appears that telco circuit enters at Power

Plant and ties to Western Area Power Administration phone switch, then delivers extensions to office/shop building

Upper Molina (Voice Gateway Router, PoE Switching and Wireless Access

New DIDs ranges will be obtained by Reclamation for this location.

Location/Label Extension Analog/IP/Optional Notes

Approximate Wiring

Distance (Feet)

Telco Number (970) 240-6576 Analog Single phone 30 Power Plant TBD* IP w/VM

*Extension will change to different DID prior to installation

Vendor Deliverables for the Project The vendor shall:

Provide all necessary hardware/software/licenses to install phones, sidecars, voice gateways, SRST, and Cisco 3602 Wireless access points.

Configure, install and test all IP and analog extensions on existing phones Configure, install and test all voice gateway equipment Mount all equipment where applicable

Ensure all security configuration is applied – system and phone security (work with Reclamation IT staff)

Configure QoS Configure 911 services Configure PRIs (minimum 2) Test/Validate IP Routing Configure/Test SRST Configure intercom/paging (destinations to be determined before install) Configure dial plan for calls over WAPA phone system (PRI connection between systems) Configure 2 Meet-Me lines (DIDs to be determined before install) Set up line groups (exact extensions in group to be determined before install) shall be configured for each location (multiple extensions ring when one number is called) Pickup groups shall be configured for sites (pickup group defined before install) Provide end user training (suggested day would be during a Thursday Morning all employee safety meeting) and shall provide each employee a handout on the use and function of the new phone system before cut over of new phones for approximately 45 employees

Provide 90 day post-installation support for troubleshooting and solving any unforeseen issues that may arise. The support shall include onsite response by a Cisco Certified Voice Engineer within 1 business day.

Provide 1-year SmartNet maintenance for all hardware/software Provide a project manager to oversee and document the project Perform a knowledge transfer to Reclamation’s system administration staff on the work performed which includes :

Configuration for all phones, analog devices, voicemail accounts, gateways, and all other necessary components to function properly according to the host system design (All router configurations, all Call Manager configurations and all VG appliance configurations for each site. Cross training for any pertinent operations.)

All equipment shall be new (not refurbished or used) from Cisco

Phone System Test Checklist:

This list needs to be tested at each facility and related device pool. One IP handset of each type per location is sufficient. All analog phones need to be tested to make/answer calls. Tests performed before cutover when possible and all remaining tests performed after cutover and before employees report for duty.

Successfully made a local call Successfully made a long distance call Successfully make Toll Free calls Call 911 and verify 911 dispatch received correct location information (some locations require that you call the local dispatch service for permission prior to performing a 911 test)

Dial 711 (National Relay) Dial 411 (Information)

Successfully dialed a 4-digit onsite number Successfully dialed a 4-digit offsite number International Calls Call Glen Canyon Test all Calling Search Space functionality Test calls routed through WAPA Phone System for calls to Glen Canyon, Flaming

Gorge, etc. (T1 PRI) Test pickup groups Test Line Groups Voicemail access Test Meet-Me bridge Test hold music Test Bells/Strobes Test all faxes Test all analog extensions Calls to site analog lines ring main line for the site SRST Fail-over (all functions work) Test Ad-Hoc Call Park Do Not Disturb Divert Call Forwarding Redial Call Back Speed Dials BLFSD Indicator/Function BLFSD w/pickup Indicator/Function Call History Directories Headset Call Hold Resume Call Call Transfer Conference List Answer Multiple call queue (up to 4 simultaneous) Call Mute Speakerphone PC Port functions Volume controls Intercom/Paging Flasher and horn shall work when the phone rings.

QUOTE REQUIREMENTS

All vendors submitting a quote for the phone systems shall provide the following with their quote. Vendors will be evaluated based on how well the information provided addresses the areas below and meets the requirements of this scope of work.

Past Performance

Submit three (3) references for phone installations completed in the last 5 years similar in type to the phone system proposed. Include the company name, a description of the project showing it is of the similar type and scope as this project, contact name, and phone number.

Technical Approach

Proposed project schedule (total time to complete proposed work to include timelines for each phase and each location)

Detailed design for the complete solution Implementation plan (installation strategy, order of implementation, testing strategy, etc..)

Vendor provided Statement of Work for all site installations (6 Montrose facilities and all affected sites for phase 1) to include line item description and pricing, design strategy for each site, project manager references and contact information and project plan in preferred vendor format.

Vendor Requirements for the Project

To be qualified to receive an award, vendors shall have the following qualifications and shall provide proof of them with their quote:

CCIE Voice certified design/installation engineers Vendor provided senior level Cisco CCIE-Voice certified engineers for design and onsite installation (Minimum or Equivalent: 5 full Call Manager system installations and minimum 3 years Cisco Voice experience at the CCIE level.)

Vendor shall be Master Certified in Cisco Unified Communications Minimum Cisco Gold Partner Vendor provided Cisco Certified Project Manager to direct the installation to meet the requirements outlined in the scope of work (project manager may be remote)

The following qualifications are not required; however, vendors who have these capabilities will receive a higher technical rating.

ISO 9000 Certification Certification as Cisco Powered Managed Services Partner for Unified Communications

Project Submittals and Meetings All submittals shall be provided to Reclamation within 30 days of project acceptance

Provide final installation documentation for all work that is performed Weekly status and coordination meetings from date of award through the completion of the project.

Final as-built documentation of implemented solution Vendor shall provide information regarding the verification tests run on the installed components that are a part of the project, and the results of those tests.

Vendor will provide detailed documentation of all configuration and procedures associated with the installation as outlined under Vendor Deliverables for the Project using system screenshots, device configurations and narratives where appropriate.

Government Provided Equipment/Information The government will provide the following to enable the installation and project to proceed:

All cabling and wiring for this project will be completed by Reclamation.

The following Network Information will be provided post award:

o Network Layout & Network Diagrams/Documentation o IP Addressing o VLAN Scheme and Assignments o VTP Layout and Configurations o STP Layout and Configurations o QoS policies and Configurations (if existing) o Switch Management o Network/Switch Host naming conventions o DHCP scheme o IP Routing Protocols o AAA schemes o SNMP schemes and parameters

IP Telephony Information:

o List of extensions and names for each site.

o DID numbers for each site & who/what these numbers are associated with.

o Name of person(s) that we will be training for “End User” training.

o IP addressing scheme(s).

o Any specific call flow requirements o Call Scripts and call flow charts that are currently being used (if applicable).

Security Information:

o Network and Switch Security Conventions o Existing Security Policy (if existing) o Ports & Protocols needed for firewall

Current SRST Site Router Information:

Site Model Version RAM/Flash Phones SLC 2911 15.0(1r)M15 256/256 240

SLV 2821 12.2.24T 256/64 38

PRO 3825 15.1.1XB 512/128 141

DUR 2821 12.4.15T8 256/128 34

GJO 2821 12.4.24T 256/128 47

FGD 2921 15.2.3T 256/256 77

FON 2911 15.2.3T 256/256 37

URM 2811 12.2.24T 256/256 14

PGD 1861 12.2.24T1 128/128 4

The numbers above include analog extensions.

Router Hardware Inventory Information:

URM-VOIP-RECNET#sh inv NAME: "2811 chassis", DESCR: "2811 chassis"

PID: CISCO2811, VID: NA, SN: FTX0911C0GF

NAME: "2nd generation two port FXO voice interface daughtercard on Slot 0 SubSlot 0", DESCR: "2nd generation two port FXO voice int"

PID: VIC2-2FXO, VID: V01, SN: FOC10260N6A

NAME: "PVDMII DSP SIMM with one DSP on Slot 0 SubSlot 4", DESCR: "PVDMII DSP SIMM with one DSP"

PID: PVDM2-16, VID: V01, SN: FOC10310HAM

SLV-VOIP-RECNET#sh inv NAME: "2821 chassis", DESCR: "2821 chassis"

PID: CISCO2821, VID: V05, SN: FTX1342AJK8

NAME: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multiflex Trunk - T1/E1 on Slot 0 SubSlot 0", DESCR: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multif"

PID: VWIC2-2MFT-T1/E1, VID: V01, SN: FOC13411SZZ

NAME: "Four port FXS DID voice interface daughtercard on Slot 0 SubSlot 1", DESCR: "Four port FXS DID voice interface daughtercard"

PID: VIC-4FXS/DID= VID: 3.1, SN: FOC12280Z2U

NAME: "Four port FXS DID voice interface daughtercard on Slot 0 SubSlot 2", DESCR: "Four

PID: VIC-4FXS/DID= VID: 3.1, SN: FOC12280ZW8

NAME: "PVDMII DSP SIMM with four DSPs on Slot 0 SubSlot 4", DESCR: "PVDMII DSP SIMM with four DSPs"

PID: PVDM2-64 , VID: V01, SN: FOC11374C74

FON-VOIP-RECNET#sh inv NAME: "CISCO2911/K9 chassis", DESCR: "CISCO2911/K9 chassis"

PID: CISCO2911/K9, VID: V06, SN: FTX1638AL9R

NAME: "3rd generation two port EM voice interface daughtercard on Slot 0 SubSlot 0", DESCR: "3rd generation two port EM voice inter"

PID: VIC3-2E/M, VID: V02, SN: FOC16314G49

NAME: "3rd generation two port EM voice interface daughtercard on Slot 0 SubSlot 1", DESCR: "3rd generation two port EM voice inter"

PID: VIC3-2E/M, VID: V02, SN: FOC16314FX2

NAME: "2nd generation four port FXO voice interface daughtercard on Slot 0 SubSlot 2", DESCR: "2nd generation four port FXO voice i"

PID: VIC2-4FXO, VID: V04, SN: FOC16325H47

NAME: "3rd generation four port FXS DID voice interface daughtercard on Slot 0 SubSlot 3", DESCR: "3rd generation four port FXS DID"

PID: VIC3-4FXS/DID, VID: V03, SN: FOC16350PUE

NAME: "PVDM3 DSP DIMM with 32 Channels on Slot 0 SubSlot 4", DESCR: "PVDM3 DSP DIMM with 32 Channels"

PID: PVDM3-32, VID: V01, SN: FOC16330XPT

NAME: "PVDM3 DSP DIMM with 128 Channels on Slot 0 SubSlot 5", DESCR: "PVDM3 DSP DIMM with 128 Channels"

PID: PVDM3-128, VID: V01, SN: FOC164621J5

NAME: "Network Module Adapter for SM Slot on Slot 1", DESCR: "Network Module Adapter for SM Slot"

PID: SM-NM-ADPTR, VID: V01, SN: FOC16344T7Z

NAME: "High Density Analog Voice Network Module on Slot 1", DESCR: "High Density Analog Voice Network Module"

PID: NM-HD-2V, VID: V01, SN: FOC16313DXC

NAME: "Internal Services Module with Services Ready Engine on Slot 0", DESCR: "Internal Services Module with Services Ready Engine"

PID: ISM-SRE-300-K9, VID: V02, SN: FOC163536MW

NAME: "C2911 AC Power Supply", DESCR: "C2911 AC Power Supply"

PID: PWR-2911-AC, VID: V04, SN: AZS163002ZF

FGD-VOIP-RECNET#sh inv NAME: "CISCO2921/K9 chassis", DESCR: "CISCO2921/K9 chassis"

PID: CISCO2921/K9, VID: V07, SN: FTX1638ALB6

NAME: "2nd generation four port FXO voice interface daughtercard on Slot 0 SubSlot 0", DESCR: "2nd generation four port FXO voice i"

PID: VIC2-4FXO, VID: V01, SN: FOC113700E9

NAME: "3rd generation four port FXS DID voice interface daughtercard on Slot 0 SubSlot 1", DESCR: "3rd generation four port FXS DID"

PID: VIC3-4FXS/DID, VID: V03, SN: FOC16350PS1

NAME: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multiflex Trunk - T1/E1 on Slot 0 SubSlot 2", DESCR: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multif"

PID: VWIC2-2MFT-T1/E1, VID: V01, SN: FOC16227YXK

NAME: "PVDM3 DSP DIMM with 32 Channels on Slot 0 SubSlot 4", DESCR: "PVDM3 DSP DIMM with 32 Channels"

PID: PVDM3-32, VID: V01, SN: FOC16347X69

NAME: "PVDM3 DSP DIMM with 128 Channels on Slot 0 SubSlot 5", DESCR: "PVDM3 DSP DIMM with 128 Channels"

PID: PVDM3-128, VID: V01, SN: FOC16467DXA

NAME: "Network Module Adapter for SM Slot on Slot 1", DESCR: "Network Module Adapter for SM Slot"

PID: SM-NM-ADPTR, VID: V01, SN: FOC163567NZ

NAME: "High Density Voice2 Network module with no board interface on Slot 1", DESCR:

"High Density Voice2 Network module with no b"

PID: NM-HDV2, VID: V02, SN: FOC1618630A

NAME: "Internal Services Module with Services Ready Engine on Slot 0", DESCR: "Internal Services Module with Services Ready Engine"

PID: ISM-SRE-300-K9, VID: V02, SN: FOC16347HWQ

NAME: "C2921/C2951 AC Power Supply", DESCR: "C2921/C2951 AC Power Supply"

PID: PWR-2921-51-AC, VID: V03, SN: QCS1629H0H0

PRO-VOIP-RECNET#sh inv NAME: "3825 chassis", DESCR: "3825 chassis"

PID: CISCO3825, VID: V05, SN: FTX1341A0CC

NAME: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multiflex Trunk - T1/E1 on Slot 0 SubSlot 0", DESCR: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multif"

PID: VWIC2-2MFT-T1/E1, VID: V01, SN: FOC13372Q0Q

NAME: "Four port FXS DID voice interface daughtercard on Slot 0 SubSlot 1", DESCR: "Four port FXS DID voice interface daughtercard"

PID: VIC-4FXS/DID= VID: 3.1, SN: FOC13422A78

NAME: "Four port FXS DID voice interface daughtercard on Slot 0 SubSlot 2", DESCR: "Four port FXS DID voice interface daughtercard"

PID: VIC-4FXS/DID= VID: 3.1, SN: FOC13342T0N

NAME: "3rd generation four port FXS DID voice interface daughtercard on Slot 0 SubSlot 3", DESCR: "3rd generation four port FXS DID"

PID: VIC3-4FXS/DID, VID: V02, SN: FOC13492ZL6

NAME: "PVDMII DSP SIMM with four DSPs on Slot 0 SubSlot 4", DESCR: "PVDMII DSP SIMM with four DSPs"

PID: PVDM2-64, VID: V01, SN: FOC13374PB3

NAME: "PVDMII DSP SIMM with four DSPs on Slot 0 SubSlot 5", DESCR: "PVDMII DSP SIMM with four DSPs"

PID: PVDM2-64, VID: V01, SN: FOC133156HH

PGD-VOIP-RECNET#sh inv NAME: "C1861-SRST-F/K9 Chassis", DESCR: "C1861-SRST-F/K9 Chassis"

PID: C1861-SRST-F/K9, VID: V02, SN: FTX1341834P

NAME: "2nd generation four port FXO voice interface daughtercard in DaughterCard Slot 2", DESCR: "2nd generation four port FXO voic"

PID: VIC2-4FXO, VID: V01, SN: FOC1137006H

DUR-VOIP-RECNET#sh inv NAME: "2821 chassis", DESCR: "2821 chassis"

PID: CISCO2821, VID: V05, SN: FTX1310A1XC

NAME: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multiflex Trunk - T1/E1 on Slot 0 SubSlot 0", DESCR: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multif"

PID: VWIC2-2MFT-T1/E1, VID: V01, SN: FOC13103WNZ

NAME: "Four port FXS DID voice interface daughtercard on Slot 0 SubSlot 1", DESCR: "Four

PID: VIC-4FXS/DID= VID: 3.1, SN: FOC12386W30

NAME: "2nd generation four port FXO voice interface daughtercard on Slot 0 SubSlot 2", DESCR: "2nd generation four port FXO voice i"

PID: VIC2-4FXO, VID: V01, SN: FOC1137002S

NAME: "PVDMII DSP SIMM with Two DSPs on Slot 0 SubSlot 4", DESCR: "PVDMII DSP SIMM with Two DSPs"

PID: PVDM2-32, VID: V01, SN: FOC13033FM3

NAME: "PVDMII DSP SIMM with one DSP on Slot 0 SubSlot 5", DESCR: "PVDMII DSP SIMM with one DSP"

PID: PVDM2-16, VID: V01, SN: FOC13064P3D

NAME: "PVDMII DSP SIMM with four DSPs on Slot 0 SubSlot 6", DESCR: "PVDMII DSP SIMM with four DSPs"

PID: PVDM2-64, VID: V01, SN: FOC13025QE6

GJO-VOIP-RECNET#sh inve NAME: "2821 chassis", DESCR: "2821 chassis"

PID: CISCO2821, VID: V05, SN: FTX1310A1XG

NAME: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multiflex Trunk - T1/E1 on Slot 0 SubSlot 0", DESCR: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multif"

PID: VWIC2-2MFT-T1/E1, VID: V01, SN: FOC13103WFQ

NAME: "Four port FXS DID voice interface daughtercard on Slot 0 SubSlot 1", DESCR: "Four port FXS DID voice interface daughtercard"

PID: VIC-4FXS/DID= VID: 3.1, SN: FOC13223SA8

NAME: "2nd generation four port FXO voice interface daughtercard on Slot 0 SubSlot 2", DESCR: "2nd generation four port FXO voice i"

PID: VIC2-4FXO, VID: V01, SN: FOC113700ER

NAME: "PVDMII DSP SIMM with Two DSPs on Slot 0 SubSlot 4", DESCR: "PVDMII DSP SIMM with Two DSPs"

PID: PVDM2-32, VID: V01, SN: FOC13033FQ7

NAME: "PVDMII DSP SIMM with one DSP on Slot 0 SubSlot 5", DESCR: "PVDMII DSP SIMM with one DSP"

PID: PVDM2-16, VID: V01, SN: FOC13064N0T

NAME: "PVDMII DSP SIMM with four DSPs on Slot 0 SubSlot 6", DESCR: "PVDMII DSP SIMM with four DSPs"

PID: PVDM2-64, VID: V01, SN: FOC16333F2G

For SLC:

UC-VOIP2-RECNET#sh inv

NAME: "CISCO2911/K9 chassis", DESCR: "CISCO2911/K9 chassis"

PID: CISCO2911/K9, VID: V06, SN: FTX1639ALWN

NAME: "VWIC3-4MFT-T1/E1 - 4-Port RJ-48 Multiflex Trunk - T1/E1 on Slot 0 SubSlot 0", DESCR: "VWIC3-4MFT-T1/E1 - 4-Port RJ-48 Multif"

PID: VWIC3-4MFT-T1/E1, VID: V01, SN: FOC17478479

NAME: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multiflex Trunk - T1/E1 on Slot 0 SubSlot 1", DESCR: "VWIC2-2MFT-T1/E1 - 2-Port RJ-48 Multif"

PID: VWIC2-2MFT-T1/E1, VID: V01, SN: FOC17027YBC

NAME: "PVDM3 DSP DIMM with 16 Channels on Slot 0 SubSlot 4", DESCR: "PVDM3 DSP DIMM with 16 Channels"

PID: PVDM3-16, VID: V01, SN: FOC16370KWG

NAME: "PVDM3 DSP DIMM with 128 Channels on Slot 0 SubSlot 5", DESCR: "PVDM3 DSP DIMM with 128 Channels"

PID: PVDM3-128, VID: V01, SN: FOC16350P1E

NAME: "C2911 AC Power Supply", DESCR: "C2911 AC Power Supply"

PID: PWR-2911-AC, VID: V04, SN: DCA1628R1HZ

FON, FGD and SLC all have VG224 appliances for all of the analog extensions (phones)

File details come from the government source that posted it. Updated .