PERFORMANCE WORK STATEMENT

FOR

TRAFFIC SIGNAL

MAINTENANCE AND REPAIR

FA4800-21-Q-0008

633 CONS

Langley Air Force Base

Joint Base Langley-Eustis, VA

PWS Contract Number Contract Traffic Signal Maintenance and Repair 8 Feb 2021

TABLE OF CONTENTS

1.0. SCOPE OF WORK

2.0. DESCRIPTION OF SERVICES

3.0. GENERAL INFORMATION

4.0. SERVICES SUMMARY

5.0. GOVERNMENT AND CONTRACTOR FURNISHED PROPERTY, SUPPLIES AND

SERVICES

APPENDIX A – APPLICABLE PUBLICATIONS AND FORMS

TECHNICAL EXHIBIT 1 - HISTORICAL WORKLOAD

1.0. SCOPE OF WORK. This requirement is for the annual inspection, preventative maintenance and repair of all seven (7) traffic signal systems including associated controllers, conflict monitors, light heads, crosswalk lights, cross walk controls, sensor loops and emergency vehicle preemption systems (EVP) on Langley AFB, VA. In addition, the contractor shall program controls to timing schedules, maintain the fire department emergency traffic control system, and provide service calls in the event of required maintenance, or malfunctions.

2.0 DESCRIPTION OF SERVICES. The Contractor shall provide all management, transportation, tools, supplies, equipment, and labor necessary to maintain and repair all traffic signals at Langley AFB, Virginia in a manner that will ensure continuous and reliable operation.

Maintenance and repair services shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD), state and local transportation codes, commercial practices, and traffic signal manufacturer’s specifications.

2.1 Maintenance Services. The contractor shall perform annual inspections for all traffic signal systems including controllers, light heads, cross walk lights, cross walk controls, sensor loops and emergency vehicle pre-emption systems (EVP). Additionally, service calls, when required, shall be performed 24 hours per day, seven (7) days per week, 365 days per year.

2.1.1. The contractor shall perform preventive maintenance on each traffic signal identified in Exhibit A to ensure reliable and continuous operation. As part of preventive maintenance the contractor shall, but is not limited to, align light heads, replace light head shields, replace light bulbs (cross walk heads) and repair cross walk call buttons. The contractor shall program controls to timing schedules designated by the government representative. The contractor shall maintain the fire department emergency traffic control system. The maintenance work shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD), state and local transportation codes, commercial practices or manufacturer’s specification.

2.1.2. The contractor shall prepare and submit a written report within two-business days after the annual inspection. The report shall identify each traffic signal, the location, maintenance work performed, repairs needed, estimated repair costs, date of inspection, name of inspector, and overall condition of the signal system(s).

2.1.3. The contractor shall perform the first annual preventive maintenance on all traffic signals within the first 90 days of the period of performance.

2.2. Service Calls. The contractor shall respond to all service calls within one (1) hour of notification, whether answered in person, answering service or by answering machine 0730-1630 hours, Monday-Friday and respond on-site within two (2) hours of notification. Time starts at the time of actual receipt of voice message by the QAP or Fire Department Emergency Desk after normal work hours. A traffic light that malfunctions is considered a service call. Any malfunctioning traffic light repair is considered urgent. The contractor shall diagnose, troubleshoot and repair the malfunction immediately if possible. If the malfunction can’t be corrected immediately and without parts, the contractor shall follow the procedures listed in para 2.3.

2.2.1. Reports: The contractor shall prepare and submit a written report within two business days after maintenance and repairs are completed. The report shall include the date and time of the service call, the location of the traffic signal, the repairs performed, and the name of the technician performing the repairs. If additional repairs are required the contractor shall submit a written report with quote within 48 hours of service call. The report shall identify each traffic signal, the location, required repairs and parts list.

2.3 Repairs. The contractor shall identify, in writing, all necessary repairs considered to be out of the scope of preventative maintenance as defined within this PWS. The contractor shall accomplish all work order tasks during normal duty hours; however, occasions may arise that require work to be accomplished outside of these hours. The contractor shall coordinate all routine work outside of normal duty hours with the COR and the CO.

2.3.1. The COR will approve each repair that has a total cost under $2,500.00 and the Contracting Officer (CO) will approve each service call/repair that has a total cost of $2,500.00 and greater. The contractor is not authorized to perform unscheduled work without the below approvals.

2.3.1.1. All work with the total cost of each repair under the micro-purchase threshold limit (currently $2,500.00) shall be approved by the COR first before the contractor is authorized to perform. The contractor shall repair the affected system or area within the mutually agreed upon time after notification.

2.3.1.2. All work with the total cost of each repair over the micro-purchase threshold limit (currently $2,500.00) is required to be approved by a CO to determine the price to be fair and reasonable. The process for CO approval is outlined below.

2.3.1.2.1. When the contractor identifies a repair that is estimated to cost $2,500.00 or more, the contractor shall contact the COR first and provide the COR with the scope of work for repairs.

The contractor shall not provide any pricing or estimates, for any repair that is estimated to cost $2,500.00 or more. The contractor shall only provide the scope of work to the COR.

2.3.1.2.2. The COR will submit a repair request to the 633 CONS contract specialist, who will then send a Request for Quote (RFQ) to the contractor.

2.3.1.2.3. The contractor shall provide their quote to the 633 CONS contract specialist, who will then coordinate with the COR to ensure technical acceptability. Once the COR provides their technical review to the 633 CONS contract specialist, a Letter of Direction (LOD) will be issued by 633 CONS for the contractor to begin the repairs. The contractor shall complete the repairs within the mutually agreed upon time stated in the LOD after the LOD notification. A minimum of three (3) quotes shall be submitted by the contractor for items that are not proprietary to the Original Equipment Manufacturer (OEM).

2.3.1.3. The contractor shall invoice for all repairs after the work is completed and submit all tickets for the work as one (1) attachment in iRAPT.

2.4. Personnel Qualifications (if applicable) – Contractor personnel shall have the technical skills necessary to provide the required service to all contracted equipment and contractor furnished equipment.

2.5. Deliverables. The contractor shall submit all deliverables in electronic form and shall produce reports using the Microsoft Office suite of applications. All deliverables must meet professional standards and the requirements set forth in contractual documentation. The contractor shall be responsible for delivering all end items specified.

Document/Item Due

Contract Manager Designation Prior to the beginning of performance Contractor's Quality Control Plan NLT 10 working days after contract award Blank Inspection Report Prior to the beginning of performance Annual Inspection Report W/in five business days of inspection Repair & Maintenance Quotes As needed

Repair & Maintenance Report

W/in five business days of repair &maintenance

3.0. GENERAL INFORMATION.

3.1. Hours of Operation. The hours of operation are 0730 to 1630 Eastern Standard Time (EST), Monday – Friday, excluding federal holidays. If the contractor wishes to perform any services outside of the normal hours of operation, the contractor shall coordinate with the Contracting Officer Representative (COR) and the Contracting Officer (CO) no later than one week prior to the scheduled event. In the event of emergency circumstances, accommodations may be made on a case by case basis.

3.1.1. Base Closure Days. If the Base Commander determines the base is closed due to snow, hurricane, or Acts of God, the contractor shall reschedule work planned for this time.

3.1.2. Federal Holidays. The Contractor shall not be required to work any of the following federal holidays:

New Year’s Day - 1 January

Martin Luther King Day - 3rd Monday in January Washington’s Birthday - 3rd Monday in February Memorial Day - last Monday in May Independence Day - 4 July Labor Day - 1st Monday in September Columbus Day - 2nd Monday in October Veteran’s Day - 11 November Thanksgiving Day - 4th Thursday in November Christmas Day - 25 December

3.1.2.1. If a holiday falls on Saturday, the preceding Friday shall be observed. If a holiday falls on Sunday, the following Monday shall be observed. If a holiday falls on a scheduled service day, the contractor shall be responsible for rescheduling services for the first day post the holiday observance.

3.2. Essential Contractor Service. The Government has identified all or a portion of the contractor services performed under this contract as essential contractor services in support of mission essential functions. The Government identifies the service calls to be considered essential services. These services are not considered essential during exercises.

Note:

Services are essential if the effectiveness of defense systems or operations has the potential to be seriously impaired by the interruption of these services, as determined by the appropriate functional commander or civilian equivalentIf this paragraph is used, CONS must include provision DFARS 252.237-7023 in the solicitation and clause 252.237-7024 in the contract.

Mission-essential functions” means those organizational activities that must be performed under all circumstances to achieve DoD component missions or responsibilities, as determined by the appropriate functional commander or civilian equivalent. Failure to perform or sustain these functions would significantly affect DoD’s ability to provide vital services or exercise authority, direction, and control.

3.3. English Language Requirement. All contractor personnel shall read, understand, speak and write English fluently.

3.4. Contract Manager. The Contractor shall provide a contract manager and an alternate who shall be responsible for the performance of the work; these duties can be an additional duty.

These individuals shall have full authority to act for the contractor on all contract matters relating to the daily operation of this contract and shall be designated, in writing, to the Contracting Officer (CO). The alternate contract manager shall act for the contract manager when the manager is absent.

3.4.1. The contract manager or alternate shall be available within 2 hours to meet on the installation or by telecom with the CO and/or with other government personnel designated by the CO during normal duty hours to discuss issues or concerns.

3.5. Communication. Contractor personnel shall maintain open and professional communication with government personnel at all times. Complaints validated by the COR shall be reported in writing to the CO and the contractor for action. Failure of the contractor to take corrective action on validated complaints raised by the COR and the CO will be considered a failure to perform.

3.6. Appearance. Contractor personnel shall present a professional, conservative, and neat appearance. Contractor personnel shall report for duty in a professional manner, in appropriate attire and having complied with socially acceptable standards of personal hygiene.

3.7. Contractor Identification. All contractor personnel attending meetings, answering Government telephones, and working in other situations where their contractor status is not obvious are required to identify themselves as such to avoid being mistaken for Government officials. Contractors performing work at Government workplaces will provide their employees with an easily readable identification (ID) badge indicating the employee's name, the contractor's name, the functional area of assignment, and a recent color photograph of the employee.

Contractors shall require their employees to wear the ID badges visibly when performing work at Government workplaces. Contractor personnel must also ensure that all e-mails, documents, or reports they produce are suitably marked as Contractor products or that Contractor participation is appropriately disclosed. All signature blocks on e-mails shall indicate the Contractor's name.

All e-mail address lines shall include CTR in the address line.

3.8. Conflict of Interest. The contractor shall not employ any person who is an employee of the United States Government if the employment of that person would create a conflict of interest.

The contractor shall not employ any person who is an employee of the Department of the Air Force, either military or civilian, unless such a person seeks and receives approval in accordance with the Department of Defense (DoD) Directive 5500.7 and Air Force policy. If prior military, personnel must have been discharged under honorable conditions with no administrative actions taken against them.

3.9. Security Requirements for Unclassified Contracts. The contractor shall ensure the necessary pass and identification items required for contract performance are obtained for all personnel.

3.9.1. Listing of Personnel. The contractor shall maintain a current listing of personnel. The list shall include the employee’s name, social security number and level of security clearance. The list shall be validated and signed by the company’s Facility Security Officer (FSO) and provided to the sponsoring agency’s security manager, the COR, and the CO. An updated listing shall be provided when an employee’s status or information changes.

3.9.2.Temporary Base Access Passes. Use this paragraph for contracts on Langley AFB. The contractor shall ensure that each employee obtains the following pass and identification items:

all necessary cards, passes, buttons, decals, or other items required for access to the areas and the installation. Upon contract award and the replacement of any employees, the contractor will be required to complete a base access request form which will be submitted to the COR. The COR will submit the pass request to the 633d Security Forces Squadron (633 SFS) to obtain the necessary identification items. Upon approval of the pass request by 633 SFS, the contractor employee will be required to obtain any individual and vehicle identifications media at the 633 SFS Pass and Identification Section, 20 Nealy Ave (Bldg 5) on Langley AFB, VA.

3.9.3. Employee clearance requirements. As a minimum, contractor personnel must be able to obtain and maintain a TIER 1, favorable suitability/fitness determination under 5 CFR 731 or equivalent. The Government will submit background investigations for positions that require a Common Access Card (CAC) and/or IT access only. Prior to CAC issuance, an FBI fingerprint check must be completed without adverse comment, and the T1 Investigation or equivalent must be initiated. CACs will not be issued before the fingerprint check results have been completed and the investigation has been opened/scheduled at Office of Personnel Management (OPM).

Contractor personnel receiving unfavorable T1 Investigations shall not be employed. The sponsoring Government agency will submit requests for investigation on AF Form 2583, Request for Personnel Security Action, at no additional cost to the contractor. The contractor shall comply with the requirements of DoDM 5200.02, AFM 16-1405 Personnel Security Program and AFI 33-119, Electronic Mail (E-Mail) Management and Use.

3.9.4 Physical Security (Security of Government Property). The contractor shall safeguard all government property, including controlled forms provided for contractor use. At the close of each work period, government equipment, facilities, and squadron assets and materials shall be secured.

3.9.5. Entry Procedures to Controlled/Restricted Areas. The contractor shall implement local base procedures for entry to Air Force (AF) controlled/restricted areas where contractor personnel will work.

3.9.6. Reporting Requirements. The contractor shall comply with the requirements of Volume 1, AFI 71-101, Criminal Investigations, and paragraph 1.1 of Volume 2, Protective Service Matters. Contractor personnel shall report to an appropriate authority any information or circumstances of which they are aware that may pose a threat to the security of DoD personnel, contractor personnel, resources, and classified or unclassified defense information. The contractor personnel’s immediate supervisor shall brief him/her upon initial on-base assignment and as required thereafter.

3.9.7. Retrieving Identification Media. The contractor shall return all identification media to the sponsoring agency’s security office, the COR or the CO upon completion/termination of the contract or upon departure of any personnel during the course of the contract. Failure to do so may delay payment to the contractor. Final payment may be withheld until identification media is returned.

3.8. Key Control. Use only if keys will be issued to contractor personnel for contract performance; type “Keys shall not be provided to the contractor” if not used. The contractor shall establish and implement key control procedures in the Quality Control Plan (QCP) to ensure keys issued to the contractor by the government are properly safeguarded and not used by unauthorized personnel. The contractor shall not duplicate keys issued by the government.

Contractor personnel shall not use keys to open work areas for personnel other than contractor personnel engaged in performance of their duties, unless authorized by the Facility Security Officer (FSO) or Facility Manager.

3.9. Traffic Laws. The contractor and/or contractor personnel shall comply with the installation traffic code as specified in Virginia State Law and Air Force Instruction (AFI) 31-218, Motor Vehicle Traffic Supervision (current edition). The Contractor and/or contractor personnel shall comply with current instruction on cell phone use while on any military installation.

3.10. Weapons, Firearms, and Ammunition. Contractor personnel are prohibited from possessing weapons, firearms, or ammunition, on themselves or within their contractor-owned vehicle or privately-owned vehicle while on any military installation. This prohibition includes any individual who may otherwise possess any legally issued concealed weapons permit.

3.11. Smoking in Air Combat Command (ACC) Facilities. Contractors are advised that the ACC Commander has placed restrictions on the smoking of tobacco products in ACC facilities.

AFI 40-102, Tobacco Use in the Air Force (current edition), outlines the procedures used by the commander to control smoking in our facilities. Contract personnel and visitors are subject to the same restrictions as Government personnel. Smoking is permitted only in designated smoking areas.

3.12. ENVIRONMENTAL MANAGEMENT: Joint Base Langley-Eustis (JBLE) is dedicated to the conservation, protection, and enhancement of the environment. The contractor shall comply with all: federal laws and regulations; state and local laws, ordinances, and regulations;

and Installation policies and procedures. JBLE Installation specific policies and procedures:

3.13.1. Joint Base Langley-Eustis – Langley Air Force Base. The contractor must comply with all provisions of the JBLE-Langley Environmental Special Conditions. You can review or download the document at http://www.jble.af.mil/Units/Air-Force/Langley-Environmental/ under the "Contracting- Compliance" heading. This is a living document that is updated periodically so ensure you have the latest version. If you have any questions, please contact your project manager or the 633d Contracting Officer first and have them contact the 633d CES Environmental Element on your behalf.

3.13.2. Joint Base Langley-Eustis - Fort Eustis. The contractor must comply with JBLE-I 32-101, Environmental Management with related Environmental Management Procedures (EMPs). EMPs are reviewed and/or updated at least annually. JBLE-I 32-101 and EMPs can be reviewed and downloaded at:

http://www.jble.af.mil/Units/Army/Eustis-Enviromental.

3.14 Operations Security (OPSEC)

This contract has been determined to not have critical or sensitive information requiring an OPSEC Plan.

4.0. SERVICES SUMMARY (SS). The contract service requirements are summarized in performance objectives that relate directly to mission essential items. The performance threshold http://www.jble.af.mil/Units/Air-Force/Langley-Environmental/ http://www.jble.af.mil/Units/Army/Eustis-Enviromental briefly describes the minimally acceptable levels of service required for each requirement. The SS and the contractor’s Quality Control Plan provide information on contract requirements, the expected level of contractor performance and the expected method of government surveillance and confirmation of services provided. These thresholds are critical to mission success.

Procedures as set forth in the Federal Acquisition Regulation (FAR) 52.212-4 (a), Contract Terms and Conditions - Commercial Items, Inspection/Acceptance, will be used to remedy all deficiencies. The absence of any contract requirements from the SS shall not detract from its enforceability nor limit the rights or remedies of the Government under any other provision of the contract. The Government has the right to inspect all services required in the contract.

Performance Objective Reference Paragraph Performance Threshold

Method of Surveillance

SS-1 Repair and maintain traffic signals

Paragraph 2.1. inclusive

No more than 1 discrepancy per month

Periodic Inspection

SS-2 Service Calls (0730-1630 Hrs, Monday-Friday)

Paragraph 2.1., 2.2. and 3.1. 100% response in allotted time 100%

Inspection

SS-3 Service Calls - other times Paragraph 2.1., 2.2. and 3.1. 100% response in allotted time 100% Inspection of Sign In Procedures

4.1. Performance Evaluation. The purpose of the Services Summary is to define performance evaluation and payment procedures. The Performance Objective (column 1) describes what the government will survey. Performance of a service will be evaluated to determine whether or not it meets the Performance Threshold (PT) of the contract. When the PT is exceeded, the COR will document the performance issue in a Corrective Action Report (CAR) or a Performance Assessment Report (PAR) and provide it to the Contracting Officer to finalize it and issue the report to the contractor.

4.1.1. The Government will periodically evaluate the contractor’s performance by appointing a representative(s) to monitor performance to ensure services are received. The government representative will evaluate the contractor’s performance through inspections of reports and contractor services documentation. The Government may inspect each task as completed or increase the number of quality assurance inspections if deemed appropriate because of repeated failures or because of repeated customer complaints. Likewise, the Government may decrease the number of quality assurance inspections if performance dictates.

4.1.2. If any of the services do not conform to contract requirements, the Government may require the contractor to perform the services again in conformity with contract requirements at no increase in contract amount. When the defects in services cannot be corrected by re-performance, the Government may:

- Require the contractor to take necessary action to ensure that future performance conforms to contract requirements; and

- Reduce the contract price to reflect the reduced value of the services performed.

4.1.3. Failing to meet the performance threshold as outlined in the SS for any of these performance objectives in any one month period may result in an immediate Progress Meeting with the Multi-Functional Team (MFT). All remedies shall be in accordance with the FAR 52.212-4 (a), Contract Terms and Conditions - Commercial Items, Inspection/Acceptance.

4.2. Quality Control. The contractor shall develop and maintain a quality control program to ensure services are performed in accordance with this contract and PWS. The contractor shall develop and implement procedures to identify and prevent non-performance and continual repeat of defective service. A written Quality Control Plan (QCP) shall be submitted to the CO and COR for review and feedback. The plan shall be submitted no later than 10 working days after award. The plan shall specifically address the contractor’s strategy to provide quality workmanship, continual process improvement and for correcting deficiencies as required.

4.3. Quality Assurance. The Government shall inspect and evaluate the contractor’s performance to ensure services are received in accordance with requirements set forth in this contract. The COR shall inspect by watching actual task performance, physically checking an attribute of the completed task, checking management information reports, investigating customer complaints, conferring with facility managers, or otherwise inspecting the task or its results to determine whether or not performance meets the standards contained in this PWS. The COR will record surveillance results. Results of the surveillance then become the official Air Force record of the contractor’s performance. When a performance threshold has not been met or contractor performance has not been accomplished, the COR will initiate a Corrective Action Report (CAR) or Performance Assessment Report (PAR), and provide the Contracting Officer a Contract Discrepancy Report (CDR) for issuance to the contractor. The contractor shall respond to the CDR in accordance with instructions provided and return it to the Contracting Officer no later than the suspense given by the CO.

4.4. Surveillance Methods.

4.4.1. 100% Surveillance. This method requires the COR to inspect the service each time it occurs. Results shall be annotated on the inspection checklist. Any deficiency shall be documented and the contractor shall re-perform service as directed by the COR. Any unsatisfactory inspection identified but re-performed acceptably, shall still be counted as an unsatisfactory inspection for trending purposes.

4.4.2. Periodic Surveillances. This method requires the COR to employ a spot check style of evaluation based on the contractor’s schedule. Periodic surveillances will be conducted on a scheduled basis (daily, weekly, monthly, quarterly, semi-annual or annually) and may be adjusted, based on quality trends. Any unsatisfactory inspection (defect) result shall be recorded, and the contractor shall re-perform the service after notification by the COR.

5.0. GOVERNMENT AND CONTRACTOR FURNISHED PROPERTY, SUPPLIES

AND/OR SERVICES.

There is no Government-furnished property for this Contractor that meets the intent of FAR Part 45. There is Government equipment that will remain in the control and accountability of the Government.

Equipment Inventory. An inventory of Government equipment to be used by the contractor to perform this requirement shall be done within five (5) calendar days after the start of the contract period, and not later than ten (10) calendar days before the completion of the contract period (including any option periods). The Contractor and CORs shall conduct a joint inventory of all Government equipment and the Contractor shall sign a hand receipt for all equipment provided by the Government. During joint inventory, any items of equipment missing or not in working order shall be recorded and the Contracting Officer notified in writing. The Contractor and the Government representative shall jointly determine the working order and condition of all equipment and document their findings on the inventory.

APPENDIX A

APPLICABLE PUBLICATIONS AND FORMS

ESTIMATED WORKLOAD DATA

LOCATION TYPE OF EQUIP QTY UNIT

Elm St and Sweeney Blvd

Eagle Signal Controller, NC108A6, 8- phase 1 EA Traffic Control Technologies Conflict Monitor, LNM Series 1 EA ELTEC Time Clock , TC-12 1 EA EDI Load Switch, Mod 510 1 EA EDI Flasher, Mod 810 1 EA Loop Detector, Microsense 1 EA Loop Detector, Sarasota, 215B./235T. 1 EA Lamps, 69W/120v 3 EA

Sweeney Blvd, Nealy and Hammond Aves

Crouse-Hinds Controller, DM-800, 8-phase 1 EA Traffic Control Technologies Conflict Monitor, LNM Series 1 EA EDI Load Switch, #510 1 EA EDI Flasher, #810 1 EA Loop Detector, Sarasota, 215B.& 235T. 1 EA Loop Detector, Microsense 1 EA Lamps, 69W/20v 3 EA

Nealy Ave & Burrell St

Econolite Traffic Controller, 12-phase, ASC/2 1 EA Eberle Design Inc. Conflict Monitor, NSM-12 1 EA 4-Channel Loop Detector, LM304 1 EA Load Switch, Mod #200 1 EA Lamps, 69W/120v 3 EA

Sweeney Blvd and Holly St

Traffic Control Technologies controller, LMD9200, 8 Phase 1 EA Traffic Control Technologies Conflict Monitor Cat #8311A 1 EA Traffic Control Technologies master controller M3000E 1 EA 3M Opticom Priority Control Sys, 3M model 754 Phase Selector with a 3M model 760 Card Rack

EA

Peek Technologies model #Sarasota 353T/MS loop monitors 7 EA Cross Walk Indicators 4 Heads

Cross Walk Call Buttons 4 EA

Nealy Ave, Rickenbacker Rd and Burrell St

Traffic Control Technologies controller, LMD9200, 8 Phase 1 EA Traffic Control Technologies Conflict Monitor Cat #8311A 1 EA Traffic Control Technologies master controller M3000E 1 EA 3M Opticom Priority Control Sys, 3M model 754 Phase Selector with a 3M model 760 Card Rack

EA

EDI (Eberle Design Inc.) model #LM301t. loop monitors 8 EA Cross Walk Indicators 4 Heads Cross Walk Call Buttons 4 EA

B367, 87 Sweeney Blvd

Traffic Control Technologies controller, LMD8000 Conflict Monitor, EDI SSM-3L

1 EA

1.0. SCOPE OF WORK
3.0. GENERAL INFORMATION
5.0. GOVERNMENT AND CONTRACTOR FURNISHED PROPERTY, SUPPLIES AND SERVICES
3.0. GENERAL INFORMATION.
3.14 Operations Security (OPSEC)
4.4. Surveillance Methods.
5.0. GOVERNMENT AND CONTRACTOR FURNISHED PROPERTY, SUPPLIES AND/OR SERVICES.
ESTIMATED WORKLOAD DATA