PN-29001854-R004-Acuity.pdf

PDF 1 MB Posted

Attached to
5963-- Security System Camera Surveillance Federal contract opportunity
Solicitation number
36C25723Q0472_0002
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

View the file

Other files for this federal contract opportunity

Other files attached to 5963-- Security System Camera Surveillance, newest first.
File Type Posted
prodimage5037b09be8cf3.pdf PDF
Illustra-Pro-Gen4-Multisensor-Data-Sheet_V6.pdf PDF
Commercial_Series_Tr_Data_sheet_enUS_75201771147.pdf PDF
VideoEdge-2U-NVR_v5-9_ds_r10_hs_en.pdf PDF
Illustra-ess-gen4-2MP-varifocal-minidome_ds_r04_hs_en_2.pdf PDF
36C25723Q0472 0002.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contact your DSC distributor www.dsc.com

1-888-888-7838

Product Features:

AcuityTM

DSC Glassbreak Detectors

Breaking a window is one of the easiest and most common ways for an intruder to enter a home or business. To help protect against this type of intrusion, an Acuity glassbreak detector is needed.

“Smart” enough to distinguish the sound of breaking glass from other common sounds found in homes and businesses, the detectors feature high-performance microphones and advanced microprocessor-based

Digital Sound Analysis (DSA) that can determine all types of breaking framed glass (plate, float, tempered, wired and laminated) up to 25 feet away. Acuity glassbreak detectors can be mounted on walls or ceilings.

Omnidirectional microphone

Advanced microprocessor-based glassbreak sensor

High-level static and transient protection

High RF immunity with SMD construction

White noise rejection mechanism

Installer test mode for glassbreak sensor

Alarm memory (latching LED) for glassbreak sensor

MOV transient / static protection

Jumper selectable sensitivity range

P/N 29001854 R004 8/10/05 9:24 AM Page 1

AcuityTM

Locating the Detector For optimum protection, Acuity glassbreak detectors should be placed in clear view of their intended area of protection. Curtains, blinds and other window coverings will absorb sound energy from the shattering glass. If this is a potential problem, mount the detector as close as possible to the protected glass.

Note: Do not mount the detector on the same wall as the protected glass or near objects, such as speakers, that produce prolonged sounds.

AFT-100 Glassbreak Simulator The AFT-100 glassbreak simulator provides the most reliable and accurate indication of the correct mounting location for the detector. Do not install the detector beyond the maximum recommended range, even if the glassbreak simulator reports additional range. Future changes in room acoustics could reduce any additional range.

Test for false alarm immunity by creating sounds in the room that will likely occur when the detector is armed.

P/ N

R

P rin te d in

C an ad a

Distributed by:

For product information www.dsc.com Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.

©2005 2005•08

DSC Glassbreak Detectors

Ordering Information:

Wall-Mount AC-100 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact AC-101 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact and Tamper Switch AC-102 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `C’ Alarm Contact and Tamper Switch Ceiling-Mount AC-500 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact AC-501 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact and Tamper Switch AC-502 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `C’ Alarm Contact and Tamper Switch

Accessories AFT-100 . . . . . . . . . . . . . . . . . . . . . . . . . Glassbreak Simulator

Acuity Mounting Locations

Ceiling-Mount Models Dimensions . . . . . . . . . . . . . . . . . . . . . 4.6” (D) x 1.4” (H)

(117 mm x 36 mm) Input Voltage . . . . . . . . . . . . . . . . . . 9 to 14.5 VDC

Current Draw . . . . . . . . . . . . . . . . . . 24 mA to 12 VDC

Current in Alarm . . . . . . . . . . . . . . . 32 mA @ 12 VDC

Alarm Relay: Contact Rating . . . 1 Amp @ 24 VDC

Tamper Switch: Contact Rating..0.1 Amp @ 24 VDC

Microphone Type . . . . . . . . . . . . . . Omnidirectional Electret Installer Test Mode . . . . . . . . . . . . . . Jumper J1 Alarm Memory Mode . . . . . . . . . . . . Jumper J2 Detection Level . . . . . . . . . . . . . . . . . Jumper J5

Wall-Mount Models Dimensions . . . . . . . . . . . . . . . . . . . . . 3.5” (L) x 2.5” (W) x 0.8” (D)

(89 mm x 64 mm x 20 mm) Input Voltage . . . . . . . . . . . . . . . . . . 9 to 16 VDC

Current Draw . . . . . . . . . . . . . . . . . . 12 mA to 12 VDC

Current in Alarm . . . . . . . . . . . . . . . 35 mA @ 12 VDC

Alarm Relay: Contact Rating . . . 1 Amp @ 24 VDC

Tamper Switch: Contact Rating..0.1 Amp @ 24 VDC

Microphone Type . . . . . . . . . . . . . . Omnidirectional Electret Installer Test Mode . . . . . . . . . . . . . . Jumper J1 Alarm Memory Mode . . . . . . . . . . . . Jumper J2 Detection Level . . . . . . . . . . . . . . . . . Jumper J3

Specifications

P/N 29001854 R004 8/10/05 9:24 AM Page 2