Text version
Contact your DSC distributor www.dsc.com
1-888-888-7838
Product Features:
AcuityTM
DSC Glassbreak Detectors
Breaking a window is one of the easiest and most common ways for an intruder to enter a home or business. To help protect against this type of intrusion, an Acuity glassbreak detector is needed.
“Smart” enough to distinguish the sound of breaking glass from other common sounds found in homes and businesses, the detectors feature high-performance microphones and advanced microprocessor-based
Digital Sound Analysis (DSA) that can determine all types of breaking framed glass (plate, float, tempered, wired and laminated) up to 25 feet away. Acuity glassbreak detectors can be mounted on walls or ceilings.
Omnidirectional microphone
Advanced microprocessor-based glassbreak sensor
High-level static and transient protection
High RF immunity with SMD construction
White noise rejection mechanism
Installer test mode for glassbreak sensor
Alarm memory (latching LED) for glassbreak sensor
MOV transient / static protection
Jumper selectable sensitivity range
P/N 29001854 R004 8/10/05 9:24 AM Page 1
AcuityTM
Locating the Detector For optimum protection, Acuity glassbreak detectors should be placed in clear view of their intended area of protection. Curtains, blinds and other window coverings will absorb sound energy from the shattering glass. If this is a potential problem, mount the detector as close as possible to the protected glass.
Note: Do not mount the detector on the same wall as the protected glass or near objects, such as speakers, that produce prolonged sounds.
AFT-100 Glassbreak Simulator The AFT-100 glassbreak simulator provides the most reliable and accurate indication of the correct mounting location for the detector. Do not install the detector beyond the maximum recommended range, even if the glassbreak simulator reports additional range. Future changes in room acoustics could reduce any additional range.
Test for false alarm immunity by creating sounds in the room that will likely occur when the detector is armed.
P/ N
R
P rin te d in
C an ad a
Distributed by:
For product information www.dsc.com Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
©2005 2005•08
DSC Glassbreak Detectors
Ordering Information:
Wall-Mount AC-100 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact AC-101 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact and Tamper Switch AC-102 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `C’ Alarm Contact and Tamper Switch Ceiling-Mount AC-500 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact AC-501 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `A’ Alarm Contact and Tamper Switch AC-502 . . . . . . . . . . . . . . . . . . . . . . . . . . Form `C’ Alarm Contact and Tamper Switch
Accessories AFT-100 . . . . . . . . . . . . . . . . . . . . . . . . . Glassbreak Simulator
Acuity Mounting Locations
Ceiling-Mount Models Dimensions . . . . . . . . . . . . . . . . . . . . . 4.6” (D) x 1.4” (H)
(117 mm x 36 mm) Input Voltage . . . . . . . . . . . . . . . . . . 9 to 14.5 VDC
Current Draw . . . . . . . . . . . . . . . . . . 24 mA to 12 VDC
Current in Alarm . . . . . . . . . . . . . . . 32 mA @ 12 VDC
Alarm Relay: Contact Rating . . . 1 Amp @ 24 VDC
Tamper Switch: Contact Rating..0.1 Amp @ 24 VDC
Microphone Type . . . . . . . . . . . . . . Omnidirectional Electret Installer Test Mode . . . . . . . . . . . . . . Jumper J1 Alarm Memory Mode . . . . . . . . . . . . Jumper J2 Detection Level . . . . . . . . . . . . . . . . . Jumper J5
Wall-Mount Models Dimensions . . . . . . . . . . . . . . . . . . . . . 3.5” (L) x 2.5” (W) x 0.8” (D)
(89 mm x 64 mm x 20 mm) Input Voltage . . . . . . . . . . . . . . . . . . 9 to 16 VDC
Current Draw . . . . . . . . . . . . . . . . . . 12 mA to 12 VDC
Current in Alarm . . . . . . . . . . . . . . . 35 mA @ 12 VDC
Alarm Relay: Contact Rating . . . 1 Amp @ 24 VDC
Tamper Switch: Contact Rating..0.1 Amp @ 24 VDC
Microphone Type . . . . . . . . . . . . . . Omnidirectional Electret Installer Test Mode . . . . . . . . . . . . . . Jumper J1 Alarm Memory Mode . . . . . . . . . . . . Jumper J2 Detection Level . . . . . . . . . . . . . . . . . Jumper J3
Specifications
P/N 29001854 R004 8/10/05 9:24 AM Page 2