Amendment_2_-_EPDM_Tech_Sheet.pdf
PDF 240 KB Posted
- Attached to
- BADL-203937 Revegetation Services associated with recent road work Federal contract opportunity
- Solicitation number
- P16PX02829
About this file
Amendment 2 - EPDM Tech Sheet
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_2_-_Attachment_1_-_Q A_9.7.2016.pdf | ||
| Attachment 3 - BADL_Grading_Sheets_203937_11and_12_final.pdf | ||
| Solicitation_and_Contract_Clauses_.pdf | ||
| Attachment_2_-_Wage_Rates__03-01-2016.pdf | ||
| 1449_-_P16PX02829_-_BADL_203937.pdf | ||
| Attachment_1_-_SOS_BADL_203937.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL INFORMATION SHEET P-101
1/05
PondGard Non-Reinforced EPDM Geomembrane (Black)
DESCRIPTION:
Firestone PondGard non-reinforced EPDM Geomembrane is a cured single-ply pond lining geomembrane.
PREPARATION OF SUBSTRATES:
1. Substrates must be clean, dry, smooth, and free of sharp edges, fins, loose or foreign materials, oil, grease, and other materials that may damage the geomembrane.
2. All roughened surfaces that can damage the geomembrane shall be repaired as specified to offer a smooth substrate.
3. All surface voids greater than 1/4" (6.3 mm) wide shall be properly filled with an acceptable fill material.
METHOD OF APPLICATION:
1. PondGard non-reinforced EPDM Geomembrane must be installed in accordance with current PondGard specifications, details and workmanship requirements.
STORAGE:
1. Store away from sources of punctures, and physical damage.
2. Assure that structural decking will support the loads incurred by material when stored on rooftop. The deck load limitations should be specified by the project designer.
3. Store away from ignition sources as geomembrane will burn when exposed to open flame.
This sheet is meant only to highlight Firestone’s products and specifications. Information is subject to change without notice. Firestone takes responsibility for furnishing quality materials, which meet Firestone’s published product specification. As neither Firestone itself nor its representatives practice design, Firestone offers no opinion on, and expressly disclaims any responsibility for the soundness of any project on which its products may be applied. If questions arise as to the soundness of a project, or its ability to support a planned installation properly, the Owner should obtain opinions of competent design engineers before proceeding. Firestone accepts no liability for any failure or for resultant damages, and no Firestone Representative is authorized to vary this disclaimer.
PRODUCT DATA
PACKAGING:
Thickness Widths Lengths Weight
.045” 7.5 ft* (2.3 m*) 50 ft (15.2 m) 0.29 lb/sf (1.4 kg/m2) (1.1 mm) 9 ft** (2.7 m**) 100 ft (30.5 m)
10 ft (3 m) 200 ft (61 m) 20 ft (6.1 m) 25 ft (7.6 m) 40 ft (12.2 m) 50 ft (15.2 m)
.060” 7.5 ft* (2.3 m*) 50 ft (15.2 m) 0.40 lb (1.9 kg/m2) (1.5 mm) 9 ft** (2.7 m**) 100 ft (30.5 m)
10 ft (3 m) 20 ft (6.1 m)
*Packaged 2 panels per roll.
**Available in 100’ (30.5 m) rolls only.
PRECAUTIONARY DATA:
1. Take care when moving, transporting, handling, etc.
to avoid sources of punctures and physical damage.
2. Isolate waste products, such as petroleum products, greases, oils (mineral and vegetable) and animal fats from the PondGard geomembrane. Contact Firestone Specialty Products Department for specific recommendations.
3. Refer to Material Safety Data Sheets (MSDS) for safety information.
LEED INFORMATION:
Post Consumer Recycled Content: 0% Post Industrial Recycled Content: 0% Manufacturing Locations: Prescott, AR
Kingstree, SC
Firestone Building Products Company A Division of BFS Diversified Products, LLC
310 East 96th Street, Indianapolis, Indiana 46240 Sales: (800) 428-4442 Specialty Products (800) 428-4442 ext. 7238 or 7252
Internet Address: http://www.firestonebpco.com
TECHNICAL INFORMATION SHEET P-101
1/05
PondGard Non-Reinforced EPDM Geomembrane (Black)
PHYSICAL PROPERTIES
Property Test Method Units Minimum
ASTM Performance 45 mil 60 mil
SI Eng SI Eng Specific Gravity ASTM D792 gm/cc 1.1 1.1 1.1 1.1 Unit Weight ASTM D751 kg/m2 (lb/ft2) 1.3 .28 1.8 .40 Thickness (min. ave.)
*Lowest individual of 10 values
ASTM D5199 mm (in) 1.14 -10%
.045 -10%
1.52 -10%
.060 -10%
Tensile Properties Break Strength ASTM D882 kN/m (lb/in) 8.8 50 11.4 65 Break Elongation ASTM D882 % 500 500 500 500 Tear Resistance ASTM D1004 N (lbs) 40 9 50 12 Puncture Resistance ASTM D4833 N (lbs) 150 35 190 45 Shore A Durometer ASTM D2240 65-10 65-10 65-10 65-10 Resistance to Ozone 7 days/100@37.8(150) 50% ext.
ASTM D1149 No Cracks
No Cracks
No Cracks
No Cracks
Multiaxial Elongation ASTM D5617 % 100 100 100 100 Oven Aging at
100C (212) for 170 hours
ASTM D882
% retained on tensile break strength 90 90 90 90 % retained on tensile break elongation 75 75 75 75 UV Resistance Xenon Arc for 2000 hours at 80C (176F)
ASTM G155
% retained on tensile break strength 90 90 90 90 % retained on tensile break elongation 75 75 75 75 Brittleness Temperature ASTM D746 -45C -49F -45C -49F Water Resistance weight after immersion 7 days @ 65C (170F)
ASTM D471 % +8,-2 +8,-2 +8,-2 +8,-2
Water Vapor Permeability (max.)
ASTM E96 Perm mils 2.0 2.0 2.0 2.0
Dimensional Stability ASTM D1204 % 0.75 0.75 0.75 0.75 Chronic Toxicity Screening EPA/600/4-89/ 001
ASTM E729
Method 1000.0 passes passes passes passes passes passes passes passes
Certified PondGard production materials are special order items requiring a minimum of two weeks as production lead-time Seaming Minimum Values (after 24 hours cure time) for 6” cover strip and 3” double-face tape systems
Shear ASTM D4437 Modified 508mm per minute 20 in per minute kN/m (lb/in) 6.1 35
Peel ASTM D4437 Modified 508mm per minute 20 in per minute kN/m (lb/in) *Cohesive bond mode/ FTB tape
2.4* 14*