SALIENT CHARACTERISTICS – Privacy Curtains Attachment A
Salient Characteristics:
1. Patient Life Privacy Systems, Non-Ceiling Mounted Privacy Oval Track and Hardware for Patient/Exam Rm, Lactation Room:
1.1. Material: Standard heavy duty extruded aluminum with radius top and bottom
1.2. Min. 3/8” W x 1 1/2” H - Max 5/8” W x 1 3/4” H
1.3. Various sizes of straight and bent sections available for custom configurations
1.4. Easy On- Easy Off cubical curtain configuration to accommodate ceiling mounted lifts
1.5. Hardware / accessories available for custom configurations with internal splice when needed to secure sections with stainless steel rivets (painted to match)
1.6. Standard curtain loading tool
1.7. Standard track color: White or similar to match existing
1.8. Fire Rating: Class A
1.9. Min. One-Year Warranty
2. Easy On – Easy Off Cubical Curtains:
2.1 The Easy On - Easy Off Cubicle Curtains are open C-type fast install and removal curtain system. Cubicle curtains to be manufactured flat and sized approximately 10% wider than the track length, unless specified otherwise. The curtain height will be determined by the floor-to-ceiling height and curtains should be finished approximately 10”-12” above finished floor, as suggested by Joint Commission's patient privacy standards. This distance will allow for ease in periodic floor cleaning and prevents mop and/or floor cleaner from coming in direct contact with cubicle curtain, soiling the treatment.
VA Loma Linda, Women’s Clinic A5180 10391 Corporate Dr.
Redlands, CA 92374 Project: VA Loma Linda Based Outpatient Women’s Clinic
Total Quantity: 26 rooms
1st floor (26 total) Room location/numbers: Exam 01, Exam 02, Exam 03, Exam 04, Exam 05, Exam 06, Procedure 07, Procedure 10, Exam 14, Exam 16, Exam 18, Exam 21, Exam 22, Lactation Room
Item Name:
JSN: Wall Mounted Cubicle Track With Curtain
Basis of Design:
Patient Lift Privacy Systems, Non-Ceiling Mounted Privacy, Oval Track, Custom Configuration or EQUAL:
Textured Privacy Cubicle Curtains
*Picture is for reference only to provide guidance to the vendors.
SALIENT CHARACTERISTICS – Privacy Curtains Attachment A
2.2 The C-type rings to be inserted and spaced minimum 6” and maximum 8” apart on a minimum 4” and maximum 6” National Fire Protection Association (NFPA) approved vinyl breathable mesh fabric that is integrated to minimum ½” and maximum 1“ vertical and horizontal hole size opening mesh (minimum 70 percent open) allows for fire sprinkler penetration in the unfortunate case of fire. The mesh will be required to have a minimum 18” drop from sprinkler head to fabric. If the distance of the Flat Track is farther than the 18” drop then mesh may not be necessary to meet patient privacy standards.
2.3 The cubicle curtains must use a commercial grade of molded synthetic polymer C-type rings that allow for Easy On -Easy Off handling of environmental services and nursing staff. The ring system must mount on the approximately between .25”-.5” x 1.5”-2” Flat Track and must glide effortlessly without binding over the life of the curtain.
2.4 The bottom hem of the cubicle curtain is double folded and minimum 2” and maximum 3”. The side hems are double folded and minimum 1” and maximum 2”. All hems and seams are sewn with a double needle lock stitch.
All vertical seams are surged and sewn with a double needle lock stitch for maximum durability.
2.5 The cubicle fabric will contain the following characteristics to be approved by the facility: meet NFPA 701 flame spread requirements for vertical flammability (flame spread certification paperwork must be supplied), fabric must have a antimicrobial properties that have been proven to reduce bacteria on soft surfaces, must be “evidence based” third party tested, produces bacterial reduction within one hour and antimicrobial properties must be intrinsic and irreversibly bound to the polymers of the fabric and are able to withstand a minimum of 200 commercial launderings at a temperature of not more than 160 degrees Fahrenheit (71 degrees Celsius).
2.6 CAL TB 133 Compliance
2.7 Choice of fabric: Arc-Com Shoreline-X Seafoam OR equal to match existing
2.1. Min panel size: approximately 66” W by 69” H. Maximum panel size: approximately 69” W by 72” H. Including minimum 16” and maximum 18” of integrated mesh, hemmed as required
3. Shop drawings must be provided as PDF and/or AutoCAD.
4. Warranty literature information must be provided.
4.1. Minimum (1) One-Year Warranty.
VA Loma Linda, Women’s Clinic A5180