Overhaul Pkg Rpt Viewer YC1574_1632.pdf
PDF 52 KB Posted
- Attached to
- Open-Ocean Tow Mission Federal contract opportunity
- Solicitation number
- N3220522R4057
About this file
This document package includes a request for proposal for open-ocean towing mission services for the Department of the Navy's Military Sealift Command. The solicitation seeks towing and associated services for naval vessels between shipyards and operational areas, with requirements for towing equipment inspections and hazardous waste disposal. Responses are due by November 30, 2022 with contract award anticipated by January 2023. Offerors must comply with attached Department of Labor wage determinations. The scope involves towing two tugs, YC1574 and YC1632, between Pearl Harbor, Hawaii and shipyards on the U.S. West Coast. Services include underwater hull cleaning, inspection and testing of both vessels as well as inspection and testing of towing fittings.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 22R4057 QA 0002.pdf | ||
| 22R4057 QA 0001.pdf | ||
| YC 1632 IMG_3480.jpg | JPG image | |
| YC 1574 IMG_3477.jpg | JPG image | |
| WD 20190288 REV 11.pdf | ||
| Shipyard Data Template.xlsx | XLSX spreadsheet | |
| RFP 22R4057.pdf | ||
| YC 1574 IMG_3478.jpg | JPG image | |
| YC 1574 IMG_3479.jpg | JPG image | |
| YC 1632 IMG_3482.jpg | JPG image | |
| YC 1632 IMG_3481.jpg | JPG image | |
| Drawings YC-1632 (class drawings).pdf | ||
| TUGCON 2020 (Rev. 2 (08-21)).pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UnclassifiedVSB
CSMP Summary Report
UNCLASSIFIED
62813UIC:
NAVSTA PEARL HARBOR HICNIC 62813
WC JSN Equipment Noun Name EIC Defr Dt EOC PRI TA SCR CD SCREENING VALUE
NService Cd:
YC05 L004 13-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1632-MAINT-ZINC REPLACE
P1CM
IN SUPPORT OF FUTURE TOWING REQUIREMENTS REQUEST YC1632 REQUEST
RPLACE ZINK THAT ARE FOUND TO BE DEPLETED BY 50% OR MORE.
Problem Description:
Recommended Solution: REQUEST YC1632 ZINCS THAT ARE MORE THAN 50% DEPLETED BE
REPLACED WITH NEW ZINCS OF SAME SIZE. FOR PLANNING
PURPOSES, EXPECT 20% ZINCS TO REQUIRE REPLACEMENT.
HRMC (NMD)
Special Data: First Contact: WILLIAMS T. Second Contact: PARKS, M.
YC04 L002 13-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1574-MAINT-UW HULL CLEAN
P1CM
IN SUPPORT OF FUTURE TOWING REQUIREMENTS REQUEST YC1574 UW HULL
AND FREEBOARD (THAT CAN BE REACHED FROM THE WATER) NEED TO BE
CLEANED
Problem Description:
Recommended Solution: REQUEST YC1574 UW HULL AND FREEBOARD (THAT CAN BE
REACHED FROM THE WATER) BE CLEANED OF MARINE GROWTH.
REQUEST PICTURES BE TAKEN OF ENTIRE UNDERWATER HULL AND
FREEBOARD BOTH BEFORE AND AFTER CLEANING.
HRMC (NMD)
Special Data: First Contact: WILLIAMS T. Second Contact: PARKS, M.
10-Nov-2021 17:14 Unclassified Page 1 of 5
UNCLASSIFIED
62813UIC:
NAVSTA PEARL HARBOR HICNIC 62813
WC JSN Equipment Noun Name EIC Defr Dt EOC PRI TA SCR CD SCREENING VALUE
NService Cd:
YC04 L001 10-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1574-MAINT-UW HULL INSPECT
P2CM
IN SUPPORT OF FUTURE TOWING REQUIREMENT REQUEST YC1574 UW HULL AND
FREEBOARD INSPECTION TO INCLUDE UT TEST.
Problem Description:
Recommended Solution: REQUEST INSPECT UW HULL AND FREEBOARD (THAT CAN BE
REACHED FROM THE WATER) TO INCLUDE UT TEST. UT INSPECTION
SHOULD BE IN A 3' X 3' GRID. PROVIDE A GRID MAP SO THE
LOCATION ON THE HULL CAN BE DETERMINED. PROVIDE RESULTS
OF VISUAL AND UT INSPECTION IN HARD COPY AND ELECTRONIC
MEDIA. INCLUDE AN ESTIMATE OF THE PERCENTAGE OF PBARE
MEDAL PRESENT. CONDITION AND PERCENTAGE OF ZINC MATERIAL
REMAINING AND ANY ZINCS THAT MIGHT BE MISSING OR DAMAGED. A
DESCRIPTION OF STRUCTURAL DEFICIENCIES FOUND.
HRMC (NMD)
Special Data: First Contact: WILLIAMS T. Second Contact: PARKS, M
YC05 L005 13-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1632-MAINT-TOW FITTINGS TEST
P1CM
IN SUPPORT OF FUTURE TOWING REQUIREMENTS REQUEST PERFORM
ULTRASONIC TESTING OF THE TOWING EYES AND TOWING BITS ON 1632. THE
TOWING BITS WILL HAVE TO BE CHECKED ON BOTH ENDS OF THE VESSELS AS IT
IS EXPECTED THAT THE VESSELS WILL BE TOWED IN TANDUM.
Problem Description:
Recommended Solution: REQUEST PERFORM ULTRASONIC/NDT TESTING OF THE TOWING
EYES AND TOWING BITS ON YC1632. THE TOWING BITS WILL HAVE
TO BE CHECKED ON BOTH ENDS OF THE VESSELS AS IT IS
EXPECTED THAT THE VESSELS WILL BE TOWED IN TANDUM.
PROVIDE A REPORT ON THE CONDITION OF THE FITTINGS BOTH IN
HARD COPY AND ELECTRONIC MEDIA.
HRMC (NMD)
10-Nov-2021 17:14 Unclassified Page 2 of 5
UNCLASSIFIED
62813UIC:
NAVSTA PEARL HARBOR HICNIC 62813
WC JSN Equipment Noun Name EIC Defr Dt EOC PRI TA SCR CD SCREENING VALUE
NService Cd:
YC05 L001 13-Sep-2021 1 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1632-MAINT-HAZWASTE 86591
P1CM
DISPOSAL OF HAZWASTE GENERATED DURING THE CLEANING AND INSPECTION
OF YC1632
Problem Description:
Recommended Solution: REQUEST OUTSIDE ACTIVITY DISPOSE OF HAZARDOUS WASTE
GENERATED DURING CLEANING AND INSPECTION OF YC1632
HRMC (NMD)
Special Data: First Contact: WILLIAMS T. Second Contact: PARKS, M.
YC04 L005 13-Sep-2021 1 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1574-MAINT-HAZWASTE 86591
P1CM
DISPOSAL OF HAZWASTE GENERATED DURING THE CLEANING AND INSPECTION
OF YC1574
Problem Description:
Recommended Solution: REQUEST OUTSIDE ACTIVITY DISPOSE OF HAZARDOUS WASTE
GENERATED DURING CLEANING AND INSPECTION OF YC1574
HRMC (NMD)
Special Data: First Contact: WILLIAMS T. Second Contact: PARKS, M.
YC04 L003 13-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1574-MAINT-ZINC REPLACE
P1CM
IN SUPPORT OF FUTURE TOWING REQUIREMENTS REQUEST YC1574 REQUEST
RPLACE ZINK THAT ARE FOUND TO BE DEPLETED BY 50% OR MORE.
Problem Description:
Recommended Solution: REQUEST YC1574 ZINCS THAT ARE MORE THAN 50% DEPLETED BE
REPLACED WITH NEW ZINCS OF SAME SIZE. FOR PLANNING
PURPOSES, EXPECT 20% ZINCS TO REQUIRE REPLACEMENT.
HRMC (NMD)
10-Nov-2021 17:14 Unclassified Page 3 of 5
UNCLASSIFIED
62813UIC:
NAVSTA PEARL HARBOR HICNIC 62813
WC JSN Equipment Noun Name EIC Defr Dt EOC PRI TA SCR CD SCREENING VALUE
NService Cd:
YC05 L003 13-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1632-MAINT-UW HULL CLEAN
P1CM
IN SUPPORT OF FUTURE TOWING REQUIREMENTS REQUEST YC1632 UW HULL
AND FREEBOARD (THAT CAN BE REACHED FROM THE WATER) NEED TO BE
CLEANED
Problem Description:
Recommended Solution: REQUEST YC1632 UW HULL AND FREEBOARD (THAT CAN BE
REACHED FROM THE WATER) BE CLEANED OF MARINE GROWTH.
REQUEST PICTURES BE TAKEN OF ENTIRE UNDERWATER HULL AND
FREEBOARD BOTH BEFORE AND AFTER CLEANING.
HRMC (NMD)
Special Data: First Contact: WILLIAMS T. Second Contact: PARKS, M.
YC05 L002 13-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1632-MAINT-UW HULL INSPECT
P1CM
IN SUPPORT OF FUTURE TOWING REQUIREMENT REQUEST 1632 UW HULL AND
FREEBOARD INSPECTION TO INCLUDE UT TEST.
Problem Description:
Recommended Solution: REQUEST INSPECT UW HULL AND FREEBOARD (THAT CAN BE
REACHED FROM THE WATER) TO INCLUDE UT TEST. UT INSPECTION
SHOULD BE IN A 3' X 3' GRID. PROVIDE A GRID MAP SO THE
LOCATION ON THE HULL CAN BE DETERMINED. PROVIDE RESULTS
OF VISUAL AND UT INSPECTION IN HARD COPY AND ELECTRONIC
MEDIA. INCLUDE AN ESTIMATE OF THE PERCENTAGE OF PBARE
MEDAL PRESENT. CONDITION AND PERCENTAGE OF ZINC MATERIAL
REMAINING AND ANY ZINCS THAT MIGHT BE MISSING OR DAMAGED. A
DESCRIPTION OF STRUCTURAL DEFICIENCIES FOUND.
HRMC (NMD)
10-Nov-2021 17:14 Unclassified Page 4 of 5
UNCLASSIFIED
62813UIC:
NAVSTA PEARL HARBOR HICNIC 62813
WC JSN Equipment Noun Name EIC Defr Dt EOC PRI TA SCR CD SCREENING VALUE
NService Cd:
YC04 L004 13-Sep-2021 2 1 1
CSMP Summary:
Avail ID:
Location:
Maintenance Activity:
APL: SWLIN/HSC:YC1574-MAINT-TOW FITTINGS TEST
P1CM
IN SUPPORT OF FUTURE TOWING REQUIREMENTS REQUEST PERFORM
ULTRASONIC TESTING OF THE TOWING EYES AND TOWING BITS ON YC1574. THE
TOWING BITS WILL HAVE TO BE CHECKED ON BOTH ENDS OF THE VESSELS AS IT
IS EXPECTED THAT THE VESSELS WILL BE TOWED IN TANDUM.
Problem Description:
Recommended Solution: REQUEST PERFORM ULTRASONIC/NDT TESTING OF THE TOWING
EYES AND TOWING BITS ON YC1574. THE TOWING BITS WILL HAVE
TO BE CHECKED ON BOTH ENDS OF THE VESSELS AS IT IS
EXPECTED THAT THE VESSELS WILL BE TOWED IN TANDUM.
PROVIDE A REPORT ON THE CONDITION OF THE FITTINGS BOTH IN
HARD COPY AND ELECTRONIC MEDIA.
HRMC (NMD)
10-Nov-2021 17:14 Unclassified Page 5 of 5