Options Price Sheet.docx

DOCX document 14 KB Posted

Attached to
Radio Frequency (RF) Shielded Door replacement Federal contract opportunity
Solicitation number
FA930220Q0020
Issued by
Department of the Air Force Materiel Command Test Center

About this file

This combined synopsis/solicitation from the Department of the Air Force Materiel Command Test Center seeks quotes to replace three radio frequency shielded doors at Edwards Air Force Base in accordance with the attached performance work statement and statement of work. Offerors must provide pricing for four options on the attached price sheet by September 16th, 2020, including labor rates and estimated completion timelines. The award will be made to the lowest priced technically acceptable small business offeror meeting the requirements. Products must demonstrate the ability to meet radio frequency shielding specifications.

View the file

Other files for this federal contract opportunity

Other files attached to Radio Frequency (RF) Shielded Door replacement, newest first.
File Type Posted
SOW - EWS- TCR RF Doors replacement 10SEP2020 rev3.docx DOCX document
FA9302-20-Q-0020 Combo Synopsis RF Shielded Door Replacement 2.docx DOCX document
FAR 52.204-24 Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment[2].pdf PDF
Wage Determination 2015-5613 Rev 15 dated 6-13-2020.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Options Price Sheet

Option 1: Remove and Replace all (3) RF Doors with new RF Sliding Doors

· Move/relocate all electrical and utilities in the walls, and surrounding area

· Remove metal ramp & plate in the vestibule

· Demo and remove concrete stairs and landing in the vestibule

· Install 3 new RF sliding doors to the below areas:

1. West Easy St to vestibule

2. Vestibule to TCR

3. Vestibule to anechoic chamber Labor Rate .

Option 1 Total Price .

Option 2: Remove and Replace Chamber RF Door and all Electrical Component Removal/Reinstallation

· Move/relocate all electrical work and utilities associated with all 3 RF Doors

· Remove metal ramp and plate in the vestibule

· Remove concrete stairs and landing in the vestibule

· Install new RF sliding door from the vestibule in to the chamber

· Install 3 foot long, by 3.5” high ramp in chamber Labor Rate .

Option 2 Total Price .

Option 3: Remove and Replace West Easy St. RF Door and TCR RF Door

· Move/relocate all electrical and utilities for the installation of all 3 RF Sliding Doors

· Install new West Easy St RF Sliding Door

· Install 3 foot, by 3.5” high ramp from West Easy St to vestibule

· Install new TCR RF Sliding Door Labor Rate .

Option 3 Total Price .

Option 4: Move/Relocate all electrical/utilities

· Move/relocate all electrical and utilities for the installation of 3 sliding RF doors, in preparation of future RF door installation Labor Rate .

Option 4 Total Price .