About this file

This combined solicitation and request for quote details procurement requirements for compute node hardware, power distribution units, and extended runtime batteries to support a federal agency's IT infrastructure. Key requirements include delivery of 12 compute nodes with 38-core Intel Xeon processors and NVIDIA GPUs, 2 data farm nodes with 16-core Intel Xeon CPUs, a 10kVA UPS with LCD display, 4 metered PDUs, and an extended runtime battery pack. Delivery for all line items is required by September 1, 2023. This procurement is set aside exclusively for small businesses with less than 1,250 employees and is being conducted by the Naval Undersea Warfare Center Division, Newport. Quotes must demonstrate that proposed products meet all technical requirements and will be evaluated based on price, delivery date, and past performance. The winning vendor will be determined by lowest price technically acceptable criteria.

View the file

Other files for this federal contract opportunity

Other files attached to Procurement of Compute Node Hardware, newest first.
File Type Posted
Attachment 1 - Draft Justification and Approval_Redacted.pdf PDF
Attachment 2 - Salient Characteristics and Minimum Specifications.pdf PDF
Attachment 3 - 52.204-24 Representations.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Government Minimum Requirements Solicitation #: N6660423Q0264

0001: Compute Node Hardware; QTY 12:

• All hardware must be delivered by Sept 1, 2023

• 7x24 Next Business Day Onsite Service, 5 Years

• Standard 5-Year Disk Retention

• Sliding Tray in front of chassis for easy system identification to include system serial number

• Modular, removable and tool less architecture for easy access

• Support for embedded NIC (Network Interface Card) to support up to 4x10GbE or 2x25GbE

• Quad Port 10/25Gb Direct Attach/SFP+ Network Adapter- Full line rate must equal 10GbE over each port

• Systems management controller for early notification to prevent server failures and secure access to remote servers

• Minimum 8X DVD ROM USB external

• On board FIPS Compliant TPM2.0 V3 (Trusted Platform Module)

• Cryptographically signed firmware

• Available USB 3.0 port on front of chassis

• Minimum 2x USB 3.0 or higher ports on rear of chassis

• Minimum 2x VGA port interfaces one on both front and back of chassis

• VGA resolution to support including 1920x1200

• System must have either a front or rear serial port

• Fixed and hot swappable drive support for SAS, SATA or NVMe

• Minimum 8GB RAID Controller Card, SAS 3.0, PCI-e Gen4 with NV Cache

• Compact 2u Form factor with slide rail mounting hardware

• Support for Red Hat Enterprise Linux

• CPU- Dual Thirty Eight Core Intel XEON Platinum 8368 2.4GHz 57MB Cache 270W

• Support for up to 8 PCI-e Gen4

• Support for up to 2 double-width or 4 single-width GPU accelerators

• Include quantity (1) NVIDIA Ampere A100 40GB, Double Wide, Full Height GPU per system

• Support for up to 12 TB system memory (dual socket). Including ECC memory including mixed memory support for RDIMM & LRDIMM at DDR4

• Front drive support for up to 24 2.5” hard drives or 24 NVMe drives

• Minimum dual redundant power supplies capable of auto sensing and auto switching 1100W or greater

• Minimum dual hot-plug redundant fans for system cooling

• Quantity 2 - C19/C20 power cords 2.5 meter

• Energy efficient 80% Power Supply or greater

• System firmware and drivers must be made available by the vendor via http or https and not solely FTP

• BIOS must support the ability to disable power button

• Ensure a secure component supply chain from factory to data center

• Minimum 1536GB DDR4-3200MT/s ECC RAM (64GBx24)

• 2 U form Factor

Minimum quantity two 800GB 2.5” Solid State Drive SAS 12Gpbs hot swappable for RAID 1 configuration

0002: Data Farm Compute Node Hardware; QTY 2:

• All hardware must be delivered by Sept 1, 2023

• 7x24 Next Business Day Onsite Service, 5 Years

• Standard 5-Year Disk Retention

• Sliding Tray in front of chassis for easy system identification to include system serial number

• Modular, removable and tool less architecture for easy access

• Support for embedded NIC (Network Interface Card) to support up to 4x10GbE or 2x25GbE

• Quad Port 10/25Gb Direct Attach/SFP+ Network Adapter- Full line rate must equal 10GbE over each port

• Quantity 1 - SFP+ to SFP+ 10/25GbE Copper Twinax direct attach cables 3 meter

• Systems management controller for early notification to prevent server failures and secure access to remote servers

• On board FIPS Compliant TPM2.0 V3(Trusted Platform Module)

• Cryptographically signed firmware

• Available USB 3.0 port on front of chassis

• Minimum 2x USB 3.0 or higher ports on rear of chassis

• Minimum 2x VGA port interfaces one on both front and back of chassis

• VGA resolution to support including 1920x1200

• System must have either a front or rear serial port

• Fixed and hot swappable drive support for SAS, SATA or NVMe

• Minimum 4GB RAID Controller Card, support for SAS,SATA, Solid-State drives Minimum PCI-e

Gen3.1 with support for RAID Levels 0,1,5 & 6 and data transfer rates up to 12Gb/s. RAID controller must also support load balancing, automatic rebuild, global hot spare with revertible hot spare

• RAID 1 Controller Card (to be used with the 2 – 480GB drives)

• Compact 1u Form factor with rail mounting hardware

• Support for Red Hat Enterprise Linux 7.x

• Quantity 2- CPU- Dual Sixteen Core Intel XEON Gold 6346 3.1GHz 36MB Cache 205W

• Support for 3 PCI-e Gen4 expansion slots

• Support for up to 3 single-width GPU accelerators

• Support for up to 10 TB memory including mixed memory support for RDIMM, LRDIMM & Intel

Optane Persistent memory modules

• Minimum internal drive support for up to 12 2.5” hard drives

• Minimum dual hot-plug redundant power supplies capable of auto sensing and auto switching 1400W or greater

• Minimum dual hot-plug redundant fans for system cooling

• Quantity 2 - C13/C14 power cords 2.5 meter

• Energy efficient 80% Power Supply or greater

• System firmware and drivers must be made available by the vendor via http or https and not solely FTP

• BIOS must support the ability to disable power button

• Ensure a secure component supply chain from factory to data center

• Minimum 512GB DDR4-3200MT/s ECC RAM (32GBx16)

• 1 U form Factor

• Quantity 2- 480GB 2.5” Solid State Drive (SATA) Minimum speed 6Gpbs hot swappable for RAID 1 configuration.

• Quantity 10- 3.84TB 2.5” Solid State Drive (SATA) Minimum speed 6Gpbs hot swappable for RAID 6 configuration.

0003: Power Distribution Unit; QTY 1:

• 3 Year Warranty minimum

• -2 year Warranty on battery

• Single phase use only

• Energy Star Compliant

• Capacity 10.0 KWatts/10kVA 208V UPS

• Input connectors: Hardwire 3-wire ( 2PH+ G)

• Output connectors: requirement are 6 power NEMA L6-30

• LCD graphics display

• Serial connectivity

• Temperature-compensated battery charging to increase battery life

• LED status indicators to also include frequency and current voltage

• Network manageable

• Automatic internal bypass

• Rack mountable 6U footprint

• Hot-swappable batteries

• Support for additional runtimes by adding battery capacity as necessary

• User-replaceable batteries

• Automatic self-test

• Scalable runtimes

• Audible alarms for immediate notification of UPS power conditions

• Firmware must be upgradeable

• Resettable circuit breaker to localize power overloads

• Support for environmental monitoring to include temperature & humidity

• Quantity (1) Extended runtime battery pack 192V 3u (should include a 2 year minimum warranty and be able to physically connect to the 10kVa UPS for extended aggregate runtimes)

0004: Metered Power Distribution Unit must include: (PR Item xx) QTY 4

• Metered Power Distribution Units (PDU) with LED display,

• Input connector type 30A National Electrical Manufacturer Association (NEMA) L6-30 connector

• Must support both C13 and C19 output connections for equipment

• 0U form factor

• Circuit protection to include circuit breaker

0005: Extended Power Distribution Unit must include: (PR Item xx) QTY 1

• Extended runtime battery pack 192V 3u

• Include a 2 year minimum warranty

• Physically connect to the 10kVa UPS (Line 2 (under software & accessories) for extended aggregate runtimes