Amendment_4.pdf
PDF 67 KB Posted
- Attached to
- Electric Load Banks Federal contract opportunity
- Solicitation number
- N65540-15-R-5177
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| AMENDMENT_8.pdf | ||
| Amendment_7.pdf | ||
| Amendment_6.pdf | ||
| Load_Bank_Specification_8024_2f_01052016.pdf | ||
| Amendment_3.pdf | ||
| Amendment_2.pdf | ||
| Load_Banks_signed_CDRLs_combined.pdf | ||
| Medium_Voltage_Load_Bank_Specification_8024_final.pdf | ||
| Load_Bank_Specification_8024_2d_07062015.docx | DOCX document | |
| Amendment_01.pdf | ||
| N65540-15-R-5178.doc | DOC document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
See Summary of Changes
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 06-Jan-2016
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N65540-15-R-5177
X 9B. DATED (SEE ITEM 11)
13-Oct-2015
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
06-Jan-2016
CODE
NAVAL SURFACE WARFARE CENTER PHILA
CODE 02311, ANTHONY RICCIARDI
215-897-1494, ANTHONY.RICCIARDI@NAVY.MIL
5001 SOUTH BROAD STREET
PHILADELPHIA PA 19112
N64498 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N65540-15-R-5177
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
SUMMARY OF CHANGES (REVISED)
1) The purpose of the subject amendment is to extend the closing date, to attach the latest spec (dated
Jan. 5th 2016) and to provide Q&A as follows:
‐ The closing date has now been extended to COB on January 21, 2016 ‐ The latest specification (dated Jan. 5th 2016) have been added as an attachment. This spec supersedes previous versions The Q&A is as follows:
Questions:
No one has quoted the contactors or the inductors to date. The issue is load break at the 0‐60HZ applied frequency.
Do you have a source for the resistive load switching contactors and main "Input Contactor" per sections 7.2.N, P & Q?
Also have questions on specification:
1. Section 7.2.F The load bank shall be fully tested. Avtron does not have the power requirements to load test.
2. Section 7.2.I. Metering will read fundamental 20‐65HZ (not down to 0HZ) using NEXUS 1250 digital meter with Ethernet and P40N display.
3. Section 7.4.3.L Isolation: The load bank control power transformer secondary and PT transformers are grounded as well as the load bank frame must be grounded by others once on site.
4. Section 9.1.G.b.a) These tests shall include 8 hours of continuous operation of each. Avtron does not have the power requirements to test.
Answers:
1. With respect to the question on testing, for clarification the specification only calls for testing of a single load module per Load Bank be tested during the specified continuous 8 hour test, not an entire Load Bank. Please verify that this is within vendor capabilities, or provide alternative tests or data that validates the individual load module design per Load Bank as specified.
2. With respect to questions concerning the "Input Contactor", the specification was changed to reflect the following:
Section 7.2
O. The Load Banks shall integrate an no‐load Input Isolation Device to isolate the Government supplied input source from the Load Banks.
Q. The ratings of the Input Isolation Device shall be compatible with the individual Load Bank power/voltage/current steady state and transient ratings.
R. The Input Isolation Device shall be designed to ensure personnel safety in accordance with NEMA ICS 7.1, IEEE 1566, and NFPA 70E.
Section 7.4
N65540-15-R-5177
K. The Load Bank shall provide a Hardwired Emergency Stop push button that would safely open the control power to the individual load segment interposing relays. The Emergency Stop push button shall be designed in accordance with IEEE 1566.
P. Auxiliary dry contacts shall be provided for each load segment contactor and auxiliary fan(s), for monitoring operating status by the Government supplied PLC.
3. With respect to metering the specification was changed to reflect the following:
Section 7.4
I. The AC Load Banks shall have a digital power meter with an Ethernet output to transmit the analog values defined below. The communication protocol used by the Ethernet output should be an industry standard protocol capable of communicating with a wide range of PLC manufacturers, including Allen Bradley Controllogix PLC product line. If an Ethernet output is not possible, a 4‐20 mA analog outputs would also be acceptable. If the analog output option is chosen, then terminal blocks/termination points shall be provided for wiring access to the Government supplied PLC. The digital power meter shall provide a minimum of the following signals:
1. Input voltage (RMS or Average as applicable)
2. Input current (RMS or Average as applicable)
3. Frequency (Hz) as applicable
4. Real Power (kW)
5. Reactive Power (kVAR) as applicable
6. Apparent Power (kVA) as applicable
7. Power Factor (lagging/leading) as applicable
J. The DC Load Banks shall have a digital power meter with an Ethernet output to transmit the analog values defined below. The communication protocol used by the Ethernet output should be an industry standard protocol capable of communicating with a wide range of PLC manufacturers, including Allen Bradley Controllogix PLC product line. If an Ethernet output is not possible, a 4‐20 mA analog outputs would also be acceptable. If the analog output option is chosen, then terminal blocks/termination points shall be provided for wiring access to the Government supplied PLC. The digital power meter shall provide a minimum of the following signals:
1. Input voltage (RMS or Average as applicable)
2. Input current (RMS or Average as applicable)
4. Real Power (kW)
4. With respect to galvanic isolation the specification was changed to reflect the following:
Section 7.2 B. The Load Banks shall have a single Customer supplied separate 480‐volt auxiliary power for all fans, control equipment, and instrumentation.
Section 7.4.3 L. All controls shall be galvanically isolated from the main Load Bank input power which is ungrounded.
2) All other terms and conditions remain unchanged.