Statement of Work
Detailed Description of Work:
1. Refurbish/replace rusted/worn parts on the CTM including internal parts. Repaint or damaged or missing paint areas. Replace or repair damaged cables and connectors.
2. The Operator Control Assembly will not reconnect to the Argus software over USB if power is cycled. Proper functionality of the Operator Control Assembly should not be broken when power is completely removed from the console.
3. The Operator Control Assembly indicators do not light during operation.
4. Continuous Timing Faults, other misc. faults appear. Fix the source of the timing faults and other misc. faults that appear in the Argus software message window when everything is working as expected.
5. Argus switch for onboard video recorded doesn't function as expected. On Phantom Camera Control Screen, start/stop recording buttons do not act as expected. Provide documentation on how to properly start, stop, and playback within Argus.
6. Argus alone does not change calibration settings requiring an edit to a text file as well. Adjust Argus software to accept all calibration settings directly within Argus.
7. Reduce overshoot when moving the mount in small (0.1 deg.) increments using DTS. Currently mount overshoots nearly 50% of the angular movement, when given single small movements. Make this adjustable so overshoot can be minimized to 10% or less.
8. Argus problems in adjusting default Cine Setting. Documentation is needed on how to properly set the default cine settings.
9. Argus video switch to port 7 causes error. Adjust Argus so that pressing button for port 7 does not cause error.
10. Documentation of all Argus screens available from the Sensors page. The sensors page provides links to configuration of the cameras for the Self Defense Test Ship installation.
11. Upgrade Argus software to run on Windows 10 64 bit Enterprise.
12. Provide camera enclosure and incorporate into Argus control for new FLIR 8313 camera.
13. Upgrade Trundle camera power supply to power 3 Phantom cameras plus cinemags.
14. Add 4 additional 75 ohm ports on the Trundle to BDE switcher.
15. Add additional ports to video switcher in Argus. (See #9). Operator should be able to adjust name of switch button and be able to choose from up to 10 video sources.
16. New Phantom VEO-340S cameras will require cabling and Argus changes. Adjust Argus so that the Phantom VEO-340S cameras can be used with the CTM. Add any necessary cabling so cameras can be used with mount.
17. Additional Camera enclosure to match existing High Speed camera enclosures to fit either a Phantom V310 or VEO-340S.
18. Camera sled position locking device.
19. Modify/replace 48" lens cover so that it fits onto the lens mount easier. It often binds and gets stuck
20. New CTM cover allowing room for three Phantom cameras plus larger FLIR IR camera. Make cover with extra expansion room at the top to house additional cameras.
21. Site visit and integration (Two Days). Provide software support and testing.
Nomenclature Description Quantity Refurbish Rusted/Worn Parts Parts and Paint Supplies 1 Upgrade for FLIR Camera Parts to Connect FLIR
RS8300
Additional 75 ohm Ports Parts to Connect 4 75 ohm ports
Upgrade for Phantom Cameras Parts for Phantom VEO-340S camera
Camera Enclosure Enclosure for Vision Research VEO-340S or V310 and lenses
Camera Sled Position Lock Camera Lock 10 New CTM Cover Cover for CTM 1
Service Line Items Refurbish Rusted/Worn Parts 1 Upgrade Operator Control Assembly-Indicator
Research and Repair Timing Faults 1 Upgrade Function of Argus of Phantom Recording
Upgrade Argus Calibration Setting 1 Reduce Overshoot when moving .1 degree increments
Upgrade Argus to run on Windows 10 Pro
Upgrade FLIR Camera 1 Add 75 ohm ports 1 Upgrade for Phantom Cameras 1 Camera Enclosure 1 Camera Sled Position Lock 1 Modify 48 inch Lense Front Cover 1 Site Visit and Integration 1
File details come from the government source that posted it. Updated .