Attachment_2_work_item_list.xlsx

XLSX spreadsheet 367 KB Posted

Attached to
CVN nuclear advance planning Federal contract opportunity
Solicitation number
N4523A18Q1052
Issued by
Department of the Navy Naval Sea Systems Command

About this file

Attachment 2 Work Item list

View the file

Other files for this federal contract opportunity

Other files attached to CVN nuclear advance planning, newest first.
File Type Posted
Attachment_1_SOW.docx DOCX document
Request_for_Quote_(RFQ)_Advanced_Planning_CVN_70.docx DOCX document
Attachment_3_Wage_Determination.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Orig BAWP

ESWBSSeq NumTitle
58751025.00A. Accomplish the requirements of SPLI-11-0006 - CVN 68 Class Carbon Steel Piping Non-Destructive Test Inspection Locations.

B. Executing Activity shall contact the Propulsion Plant Engineering Activity (PPEA) to obtain the latest applicable revision of the SPLI prior to developing execution documentation.

58752 025.00 A. Accomplish the requirements of SPLI-11-0006 - CVN 68 Class Carbon Steel Piping Non-Destructive Test Inspection Locations.

B. Executing Activity shall contact the Propulsion Plant Engineering Activity (PPEA) to obtain the latest applicable revision of the SPLI prior to developing execution documentation.

58753 025.00 A. Accomplish the requirements of SPLI-11-0006 - CVN 68 Class Carbon Steel Piping Non-Destructive Test Inspection Locations.

B. Executing Activity shall contact the Propulsion Plant Engineering Activity (PPEA) to obtain the latest applicable revision of the SPLI prior to developing execution documentation.

58754 025.00 A. Accomplish the requirements of SPLI-11-0006 - CVN 68 Class Carbon Steel Piping Non-Destructive Test Inspection Locations.

B. Executing Activity shall contact the Propulsion Plant Engineering Activity (PPEA) to obtain the latest applicable revision of the SPLI prior to developing execution documentation.

58751 009.00 A. Accomplish NDT requirements of NAVSEA DWG 8175777 using a combination of Visual Test (VT) and Ultrasonic Testing (UT) for inspection points in Tables 2 and 4.

B. Where damage is found, or thicknesses are below the minimum allowable specified in NAVSEA DWG 8175777, document these conditions in an OPNAV 4790 2Kilo or Deficiency Report, and schedule repairs according to Section 17 of NAVSEA DWG 8175777.

C. Prepare and submit inspection results in accordance with Section 18 of NAVSEA DWG 8175777. Send copies of report to:

Code 200 Engineering and Planning Department ATTN Code 261 Norfolk Naval Shipyard Bldg. 32 Portsmouth, VA 23709-5000

PMS312C, Carrier Planning Activity Attn: Code 312C20 Norfolk Naval Shipyard Bldg. 33 Portsmouth, VA 23709-5091

NSWCPD, Philadelphia Attn: Code 412 5001 South Broad St Philadelphia, PA 19112 58752 009.00 A. Accomplish NDT requirements of NAVSEA DWG 8175777 using a combination of Visual Test (VT) and Ultrasonic Testing (UT) for inspection points in Tables 2 and 4.

B. Where damage is found, or thicknesses are below the minimum allowable specified in NAVSEA DWG 8175777, document these conditions in an OPNAV 4790 2Kilo or Deficiency Report, and schedule repairs according to Section 17 of NAVSEA DWG 8175777.

C. Prepare and submit inspection results in accordance with Section 18 of NAVSEA DWG 8175777. Send copies of report to:

Code 200 Engineering and Planning Department ATTN Code 261 Norfolk Naval Shipyard Bldg. 32 Portsmouth, VA 23709-5000

PMS312C, Carrier Planning Activity Attn: Code 312C20 Norfolk Naval Shipyard Bldg. 33 Portsmouth, VA 23709-5091

NSWCPD, Philadelphia Attn: Code 412 5001 South Broad St Philadelphia, PA 19112 58753 009.00 A. Accomplish NDT requirements of NAVSEA DWG 8175777 using a combination of Visual Test (VT) and Ultrasonic Testing (UT) for inspection points in Tables 2 and 4.

B. Where damage is found, or thicknesses are below the minimum allowable specified in NAVSEA DWG 8175777, document these conditions in an OPNAV 4790 2Kilo or Deficiency Report, and schedule repairs according to Section 17 of NAVSEA DWG 8175777.

C. Prepare and submit inspection results in accordance with Section 18 of NAVSEA DWG 8175777. Send copies of report to:

Code 200 Engineering and Planning Department ATTN Code 261 Norfolk Naval Shipyard Bldg. 32 Portsmouth, VA 23709-5000

PMS312C, Carrier Planning Activity Attn: Code 312C20 Norfolk Naval Shipyard Bldg. 33 Portsmouth, VA 23709-5091

NSWCPD, Philadelphia Attn: Code 412 5001 South Broad St Philadelphia, PA 19112 58754 009.00 A. Accomplish NDT requirements of NAVSEA DWG 8175777 using a combination of Visual Test (VT) and Ultrasonic Testing (UT) for inspection points in Tables 2 and 4.

B. Where damage is found, or thicknesses are below the minimum allowable specified in NAVSEA DWG 8175777, document these conditions in an OPNAV 4790 2Kilo or Deficiency Report, and schedule repairs according to Section 17 of NAVSEA DWG 8175777.

C. Prepare and submit inspection results in accordance with Section 18 of NAVSEA DWG 8175777. Send copies of report to:

Code 200 Engineering and Planning Department ATTN Code 261 Norfolk Naval Shipyard Bldg. 32 Portsmouth, VA 23709-5000

PMS312C, Carrier Planning Activity Attn: Code 312C20 Norfolk Naval Shipyard Bldg. 33 Portsmouth, VA 23709-5091

NSWCPD, Philadelphia Attn: Code 412 5001 South Broad St Philadelphia, PA 19112

PS806.00Accomplish SCD 10568 D- Turbine Generator Air Cooler Spoolpiece Installation
25400800.00Accomplish SCD 10780 D - Install Improved Main & Turbine Generator Freshwater Lay-Up Capability
34220901.00Accomplish SCD 11014 K - Replace Emergency Diesel Generator 3 Way Valv
25610800.00Accomplish SCD 11499 D - Main Sea Water Check Valve Taper Pin Modification
25400801.00Accomplish SCD 11947 D - Turbine Generator Condenser Waterbox Vent Pipe Valve Addition
26210810.00Accomplish SCD 11971 D - Main Lube Oil Cooler Strainer Installation
43611805.00Accomplish SCD 12211 D - Relocation of FD-SC1 to Improve Salinity Cell Indication
26210812.00Accomplish SCD 12419 D - Back-up LO Tank Vent Redesign and Manhole Security
24110802.00Accomplish SCD 14309 D - Main Reduction Gear Thrust Position Indicator Removal
25510807.00Accomplish SCD 14579 D - Removal of Demineralizer Resin Tank
53420801.00Accomplish SCD 15308 D - Main Engine and Turbine Generator Gland Seal Pressure Gages Loop Seal Resolution
24110900.00Accomplish SCD 15433 K - Main Reduction Gear Security
31110901.00Accomplish SCD 15537 K - Auto Voltage Regulator Master Alarm Relocation
25720800.00Accomplish SCD 17307 D - Reroute Reserve Feed Transfer Pump Casing Vent to Dirty Drain Funnel
51730800.00Accomplish SCD 1880 D - CVN 68 Class Reboiler Heating Steam Drain Sys Valve Replacement RB-V34
51310800.00Accomplish SCD 20217 D - Vent Hood Aft EDG
53460802.00Accomplish SCD 2286 D - Dirty Drain Pump Discharge Piping
26210801.00Accomplish SCD 3521 D - Replace Vent Fog Precipitator with Mist Eliminator
53110800.00Accomplish SCD 3699 D - Brine Overboard Mixed Flow Vortex Pump
53110803.00Accomplish SCD 4514 D - Auxiliary Machinery Cooling Water/Distilling Unit Circ Water Piping TOTS Valves
25210801.00Accomplish SCD 4621 D - Group 3 Secondary Steam Plant Leslie Pilot Replacement
59320801.00Accomplish SCD 5092 D - Oily Waste Transfer Pump
32111804.00Accomplish SCD 5796 D - Low Voltage Shore Power Removal
34100800.00Accomplish SCD 5907 D - Turbine Generator Gland Seal Regulator Lube Oil Isolation Valve (SA 9271D)
55151800.00Accomplish SCD 5930 D- High Pressure Air Compressor Oil/Water Separator
51111803.00Accomplish SCD 5983 D - Sample Lines on Low Pressure Steam Drains
53110802.00Accomplish SCD 6312 D - Distilling Unit Sea Water Strainer Replace
43651804.00Accomplish SCD 7119 D - Auxiliary Lube Oil Purifier Alarm Install
53460803.00Accomplish SCD 7354 D - Dirty Drain Collection Tank Modification
25510805.00Accomplish SCD 8244 D - Elimination of Salinity Cells MF-SC2 and MF-SC3
52410805.00Accomplish SCD 8687 D - Auxiliary Gland Exhaust Condenser Bypass for Auxiliary Machinery Cooling Water System
26210803.00Accomplish SCD 9174 D - CVN69 and 70 Ripout of LO-GA5
25430800.02Accomplish SCD 9226 D - Auxiliary Gland Exhaust Condenser Epoxy Coating Increment 2
23110804.02Accomplish SCD 9309 D - LP Turbine Aft Journal Bearing Vent Increment 2
26210804.00Accomplish SCD 9525 D - Add Lube Oil Pressure Gages at LO-V23
31100803.00Accomplish SCD 9570 D - Turbine Generator Hi-Speed Stop Bypass Switch Relocation
25510806.00Accomplish SCD 9683 D - Modify Main Feed Booster Pump Recirc Lines
63111011.50A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 011.50 A. Review Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil for latest inspection report to identify the specific areas within the Bilge require preservation.

B. Prepare and preserve in accordance with NAVSEA Standard Item 009-32.

C. Update coating information in the CCIMS database located at https://ccims.dc3n.navy.mil.

Note: For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM).

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information Management System (CCIMS) database located at https://ccims.dc3n.navy.mil within 3 working days of the completion of the survey.

**SPECIAL NOTE** In October 2017 the CCIMS website will be replaced by a new system. After this date, submit inspection data and preservation close out information in the 'Carrier Structural Survey and Inspection' Material Condition Feedback (MCF) form located on the M&SWP 3.0 SharePoint web site https://share.mswp.csd.disa.mil.

63111 007.00 A. Conduct a Level 1 Survey of bilge structure, foundations, and coatings/anodes for corrosion protection and required repairs IAW MIP 1000/005 AP-1 (MRC G1N6) and the CCAMM (series). Survey to include the area from the tank top up to and including lower level deck grating. This includes foundations and bulkheads up to the same height as the deck grating.

NOTE: Perform an inspection, and provide a separate report for 'each' zone. For a listing of zones, see the MP4 Section of NAVSEA 0989-036-000 (Series), 68 Class Steam Plant Manual (SPM)

NOTE: Where as-found conditions warrant, conduct a Level 2 Inspection IAW the CCAMM (series).

B. Report deficiencies found and recommended repairs on OPNAV 4790/2K or Deficiency Report (DR).

C. Submit report of as-found conditions to TYCOM and enter inspection data into the Corrosion Control Information…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.