Attachment_1_Request_for_Clarification_1.pdf
PDF 83 KB Posted
- Attached to
- 65 FT EOD Support Craft MK-II (65SCMK2) Federal contract opportunity
- Solicitation number
- N4523A-15-R-0010
About this file
Clarification 1
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N4523A15R0010_0002.pdf | ||
| Attachment_1_Request_for_Clarification_2.pdf | ||
| N4523A15R0010_0001.doc | DOC document | |
| Attachment_1_Request_for_Clarification.doc | DOC document | |
| Technical_Proposal_Breakdown.xlsx | XLSX spreadsheet | |
| Solicitation_N4523A-15-R-0010_65FT_Diveboat.pdf | ||
| LG2_PWS.pdf | ||
| LG2_PWS_DRAFT.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR CLARIFICATION
DATE OF REQUEST: 05/06/2015 QUESTION NO:
REQUIREMENT: 65 FT EOD Support Craft MK-II
(65SCMK2)
RFP NUMBER.: N4523A-15-R-0010
ITEM NO: 3.3
TITLE: STRUCTURAL REPAIRS
ISSUING OFFICE POC(CODE 441):
Jason Baker (360)476-4452 jason.r.baker1@navy.mil
PARA. NO: 3.3.4.6.5 PAGE NO: 32 CONTRACTOR:
PLANNER’S NAME: ATTACH. NO: CONTRACTOR POC & PHONE:
CONTRACTOR QUESTION: (ONE QUESTION PER PAGE)
This requirement states to replace 6 inch x 6 inch tiles. The existing tiles installed are 22 inch x 22 inch. Do we install smaller tiles?
DO NOT WRITE BELOW THIS LINE
SPEC CHG: Y/N DWG/REF CHG. Y/N RQMTS CHG: Y/N MAT'L CHG: Y/N
TECHNICAL REVIEW: Carney, Sean C/411 SERIAL NO:
Paragraph 3.3.4.6.5 is a subparagraph to 3.3.4 and therefore only pertains to the space WR & WC 2-9-2-
Q. This is a head. The steps required for removal and installation of the deck in 2-9-2-Q are in the subparagraphs of 3.3.4.
The intent of paragraph: 3.3.4.6. is to describe the salient characteristics of the new unglazed porcelain deck tile to be installed in the field of 2-9-2-Q. Install tile that meets the requirements of ANSI A137.1
(available from the Tile Council of North America) and be unglazed, with a minimum coefficient of friction (COF) of 0.7 dry and 0.6 wet when tested in accordance with ASTM C 1028. The tile shall be 6 X
6 inch and similar or equal in color and characteristics to Crossville Inc., cross tread surface pattern, sea mist.
ALL REQUESTS FOR CLARIFICATION MUST BE RECEIVED BY THE ISSUING
OFFICE POC NO LATER THAN THE DATE & TIME IDENTIFIED IN THE REQUEST