Attachment_1_Request_for_Clarification_1.pdf

PDF 83 KB Posted

Attached to
65 FT EOD Support Craft MK-II (65SCMK2) Federal contract opportunity
Solicitation number
N4523A-15-R-0010
Issued by
Department of the Navy Naval Sea Systems Command

About this file

Clarification 1

View the file

Other files for this federal contract opportunity

Other files attached to 65 FT EOD Support Craft MK-II (65SCMK2), newest first.
File Type Posted
N4523A15R0010_0002.pdf PDF
Attachment_1_Request_for_Clarification_2.pdf PDF
N4523A15R0010_0001.doc DOC document
Attachment_1_Request_for_Clarification.doc DOC document
Technical_Proposal_Breakdown.xlsx XLSX spreadsheet
Solicitation_N4523A-15-R-0010_65FT_Diveboat.pdf PDF
LG2_PWS.pdf PDF
LG2_PWS_DRAFT.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR CLARIFICATION

DATE OF REQUEST: 05/06/2015 QUESTION NO:

REQUIREMENT: 65 FT EOD Support Craft MK-II

(65SCMK2)

RFP NUMBER.: N4523A-15-R-0010

ITEM NO: 3.3

TITLE: STRUCTURAL REPAIRS

ISSUING OFFICE POC(CODE 441):

Jason Baker (360)476-4452 jason.r.baker1@navy.mil

PARA. NO: 3.3.4.6.5 PAGE NO: 32 CONTRACTOR:

PLANNER’S NAME: ATTACH. NO: CONTRACTOR POC & PHONE:

CONTRACTOR QUESTION: (ONE QUESTION PER PAGE)

This requirement states to replace 6 inch x 6 inch tiles. The existing tiles installed are 22 inch x 22 inch. Do we install smaller tiles?

DO NOT WRITE BELOW THIS LINE

SPEC CHG: Y/N DWG/REF CHG. Y/N RQMTS CHG: Y/N MAT'L CHG: Y/N

TECHNICAL REVIEW: Carney, Sean C/411 SERIAL NO:

Paragraph 3.3.4.6.5 is a subparagraph to 3.3.4 and therefore only pertains to the space WR & WC 2-9-2-

Q. This is a head. The steps required for removal and installation of the deck in 2-9-2-Q are in the subparagraphs of 3.3.4.

The intent of paragraph: 3.3.4.6. is to describe the salient characteristics of the new unglazed porcelain deck tile to be installed in the field of 2-9-2-Q. Install tile that meets the requirements of ANSI A137.1

(available from the Tile Council of North America) and be unglazed, with a minimum coefficient of friction (COF) of 0.7 dry and 0.6 wet when tested in accordance with ASTM C 1028. The tile shall be 6 X

6 inch and similar or equal in color and characteristics to Crossville Inc., cross tread surface pattern, sea mist.