Sole_Source.doc
DOC document 116 KB Posted
- Attached to
- Capacitors Federal contract opportunity
- Solicitation number
- N0042119Q0190
About this file
Justification
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N0042119Q0190.doc | DOC document | |
| SOW.doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
30 JAN 2019
JUSTIFICATION FOR SOLE SOURCE (Simplified Acquisitions <$100k) The service or material listed on Procurement Request (PR) number 1300767593 is sole source and competition is precluded for reasons indicated below. There are no substitutes available for this material.
The following firms were contacted and have indicated that they cannot provide an item that will meet the needs of the Government.
Company
Person Contacted Date of Call
Reason -
Date of Call Reason:
Date of Call Reason: NAVAIR METCAL (Metrology and Calibration) Program for their APN7-19 Requirements
Restricted to the following source. Provide original manufacturer’s name. (If a sole source information manufacturer distributes via dealers, ALSO provide dealer information.)
Manufacturer: POC:
Manufacturer’s Address:
Manufacturer’s Dealer/Rep: Phone Description of the item:
Estimated cost: $94,050.00
Required delivery date: 12-01-2019 Specific characteristics of the material or services that limit the availability to a sole source (unique features, function of the item, etc). Describe in detail why only this suggested source can furnish the requirements to the exclusion of other sources. (Explain)
1) P/N 1404-A Primary Standard Capacitor 1000 Pf Qty 10
2) P/N 1422-D Variable Precision Air Capacitors 35 pF - 1150 pF Qty 2
Per IET Labs, they do not have any Authorized Distributors for the above P/N’s, therefore they are the only source available. The 1404-D capacitors have been designed as primary reference standards of capacitance with which working standards can be compared. All critical parts of the plate assembly are made of invar for stability and low temperature coefficient. After heat cycling and adjustment the assembly is mounted in a heavy brass container, which after evacuation, is filled with dry nitrogen under pressure slightly above atmospheric and sealed. The container is mounted on an aluminum panel and protected by an outer aluminum case. Each capacitor is subjected to a series of temperature cycles to determine hysteresis and temperature coefficients and to stabilize the capacitance. The 1422 is a stable and precise variable air capacitor intended for use as a continuously adjustable standard of capacitance. One of the most important applications is in ac bridge measurements, either as a built-in standard or as an external standard for substitution measurements. It is available in a variety of ranges, terminal configurations, and scale arrangements to permit selection of precisely the required characteristics. The values of the working standards are determined and maintained in terms of reference standards periodically calibrated by the National Bureau of Standards. IET LABS has proprietary rights to the design, engineering and documentation of both the standard and the parts being ordered. If IET LABS does not provide the required part(s), compatibility and interchangeability problems could occur in the performance and accuracy of other internal parts and overall function These models are being procured for the use with NAVAIR workload Instrument Calibration Procedures (ICP's) and hundreds of test instruments for the calibration. Each ICP costs $21,285.00 to research, write, bench-test, QA check, and calibration interval analysis/change as required, publication costs, data element/database support/updates. All calibration activities now utilize the same calibration equipment/standards/techniques to support similar workloads and cannot be deviated or substituted. This has minimized the number of calibration procedures used Navy-wide, reduced the training requirements, caused fewer interface problems between equipment, reduced calibration time and improved compatibility between calibration laboratories.
The NAVAIR METCAL engineering team requires time and funding to do an overall requirements analysis, market survey, bench testing/analysis, inventory objectives and instrument calibration procedures to support a new standard. An effort this large would require phasing over several years. This procurement is for items that are already supported, do not require approval/certification and are urgently needed.
CHECK & FILL IN ALL APPLICABLE BLANKS BELOW
The requested material or service represents the minimum requirements of the government.
The material/service must be compatible in all aspects (form, fit and function) with existing systems presently installed. Describe the equipment you have now and how the new item/service must coordinate, connect, or interface with the existing system. (Explain) Because of these mandatory requirements set by Measurement Science Department, Corona, CA, incompatibility and interchangeability issues, exist. These Standards are used in NAVAIR ICP’s. These Procedures are distributed from the Measurement Science Department, Corona, CA to all the NAVAIR Calibration Laboratories. Units must be compatible and interchangeable with existing ICP’s and equipment. These laboratories must follow these procedures to the steps and cannot deviate or make substitutions.
A patent, copyright or proprietary data limits competition. The proprietary data is: (Explain) IET Labs Inc. has proprietary rights on engineering data, design and product documentations of their products.
These are “direct replacements” parts/components for existing equipment.
Use of OEM IET Labs Inc. ensures standardization and compatibility with existing model and support systems and minimizes critical measurement uncertainties due to operational and performance similarities.
Other information to support a sole-source buy: (Explain) Interchangeability by adding or removing other components without breaking the instrument apart and rebuilding to meet various calibration requirements is critical to turn Around Time of test instrument in support of Fleet Readiness, which is maintained through Calibration. This procurement is not an initial outfitting and configuration control is paramount to the success and uniformity of this outfitting. This unit will mate with existing equipment to expand voltage measurements. Currently one site is unable to complete ICP workload assignments because they have broken or rejected items to complete their task. Units requiring calibration due to broken or rejected assets has been rescheduled (ship & shore) to complete calibrations. All calibration activities now utilize the same calibration equipment/standards/techniques to support similar workloads. This has minimized the number of calibration procedures used Navy-wide, reduced the training requirements, caused fewer interface problems between equipment, reduced calibration time and improved compatibility between calibration laboratories.
I CERTIFY THAT STATEMENTS CHECKED, AND INFORMATION PROVIDED ABOVE, ARE COMPLETE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I UNDERSTAND THAT THE PROCESSING OF THIS SOLE-SOURCE JUSTIFICATION PRECLUDES THE USE OF FULL AND OPEN COMPETITION.
Signature: ________________________________ Activity:
Title:
Date: 30 JAN 2019
Contracting Officer’s Signature: ____________________________________
Date: _____________________
SAP SOLE SOURCE
_1612336208.unknown
_1612336212.unknown
_1612336214.unknown
_1612336215.unknown
_1612336213.unknown
_1612336210.unknown
_1612336211.unknown
_1612336209.unknown
_1612336204.unknown
_1612336206.unknown
_1612336207.unknown
_1612336205.unknown
_1612336200.unknown
_1612336202.unknown
_1612336203.unknown
_1612336201.unknown
_1612336198.unknown
_1612336199.unknown
_1612336196.unknown
_1612336197.unknown
_1612336195.unknown
_1612336194.unknown
File details come from the government source that posted it.