R201032318V101
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
This amendment is issued to delete the current specif ications and replace w ith new and also to extend the closing date to May 9, 2023.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 01-May-2023
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N0040623Q0464
X 9B. DATED (SEE ITEM 11)
05-Apr-2023
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
01-May-2023
CODE
NAVSUP FLC PUGET SOUND
467 W STREET, 2ND FL
ATTN: FRANCINE MEESTER
BREMERTON WA 98314
N00406 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N0040623Q0464
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 03-May-2023 03:00 PM to 09-May-2023 03:00 PM.
The following have been added by full text:
QUESTION AND ANSWERS 2
Why do they need a 440 outlet if there are only 115vac receptacles? If it’s indeed an outlet, what is the amperage for the 440 outlet?
-we will not require an outlet, remove from request list.
What is the primary power source for the Locker?
-not required.
Do they really want the 440 outlet that low to the bottom?
-same as first question, we will not require this spec.
Do they have manufacturer and model numbers for the cabinets they want with number and size of drawers and dividers? What color?
-we do not have any manufacturer or model numbers, the cabinet will be used to house 13 proximity firefighting suits and will not require any drawers or dividers. Color will be black.
Do they have manufacturer and model numbers for the lockers they want with number of shelves? What color?
-we do not have any manufacturer or model numbers. If you are talking about the locker for under the work bench, we do not need that anymore.
If it is the locker/ cabinet for the proximity suits, the information is in the previous question.
For the shelving, how many shelves and the spacing?
-for the floor to ceiling shelving, we will need 4 shelves spaced out evenly top to bottom
For the tool hangar, what tools will they hang there. Do they want us to provide tool boards and brackets?
-we will be hanging air tools/pry bars/haligan tools/ bolt cutters. Yes we require tool boards and brackets.
What is the material for the workbench top?
-work bench material will need to be aluminum.
Do they want a shelf above the work bench? If so, how deep?
-No shelving required above work bench.
Do they want a dedicated light above the workbench?
-No light is required above bench.
Standard size boxes:
Standard 20-foot shipping containers come in the following two sizes: 20’- x 8’ x 8’-6” (standard height) or 20’- x 8’ x 9’-6” (high cube). If you want a 20’ x 10’ x 10’, it would have to be custom manufactured.
-BOX SIZE WE ARE REQUESTING WILL BE 20’ x 8’ x 8’-6”(standard height).
SPECIFICATIONS NEW
CRASH AND SALVAGE CONEX BOX
CONTRACTOR TO PROVIDE 1 MODIFIED CONEX BOX CONTAINER, CUSTOM, STEEL,
WEATHERPROOF:
20’ x 8’ x 8’-6”(standard height) with a 7'W galvanized steel roll-up door on the front and a 3'W galvanized steel roll-up door on the back Exterior paint to be bright red marine grade paint to withstand severe weather Interior paint to be a flat white Deck is to be a heavy duty dark gray deck paint or non-skid or rhino lining Vents: (3 on each side) 1' x 1' adjustable aluminum or galvanized steel louver vents 7'W x 2.5'D x 4'H work bench with a 1/2" lip on the work surface and with aluminum top
(1) 4'W 20-bottle 4500 psi scuba bottle storage rack with secured-for-sea strap for each bottle
(6) Universal extinguisher bottle brackets mounted inside the door if possible.
(2) black double door lockable storage cabinets 4'W x 2.5’D x 6'H for hanging of 12 proximity suits For the shelving, require floor to ceiling shelving with 4 shelves spaced out evenly top to bottom Requires tool boards and bracket for hanging air tools, pry bars, haligan tools, and bolt cutters All furnishings (workbench, racks, shelves and cabinets) to be aluminum or galvanized steel and wall mounted for stability/safety Hoisting points on the top of each corner, minimum 10,000 lb lift capacity per point, with a 1.25" galvanized steel shackle rated for 12 tons on each pick point Container to have forklift pockets underneath for lifting Roll-up doors to be lockable with a padlock and chain hoist
IN ACCORDANCE WITH THE ATTACHED DRAWINGS AND ILLUSTRATIONS.
For drawings, please email both Ms. Frankie Meester, francine.a.meester.civ@us.navy.mil and Ms. Kim Gripp, kim.l.gripp.civ@us.navy.mil
The following have been modified:
QUESTIONS AND ANSWERS
CONEX BOX
SOLICITATION N0040623Q0464 QUESTIONS
1. Is it possible to get an extension?
ANSWER: Solicitation is extended to 03 May 2023.
2. The spec requires a “weatherproof 440V hookup with 450>120 stepdown transformer”.
a. Is there a particular cable-mounted plug/receptacle that the ship will be using to connect to this container’s “weatherproof 440V hook-up”?
b. Is there a specific amperage that this hookup needs to allow for?
ANSWER: a. there is not a specific receptacle the ship will use to connect the container to the ship.
Generally it is just a three prong extension cord.
b. No there is no specific amperage.
3. The spec requires “(6) universal extinguisher bottle brackets”. Where are those meant to be located? (they are not shown on the drawings, from what I can tell.)
ANSWER: The brackets would do best if places on the wall of the conex closest to the door for easy access. If you could mount the brackets on the inside of the door that would be best if there is space.
4. The spec requires “(6) double door lockable storage cabinet with 5 adjustable shelves 4'w x 2.5"d x 6'h for storage of 12 proximity suits”.
a. Is the quantity of (6) cabinets correct? (the drawings make it look like there may only be one)
b. Can we assume that the dimensions (4'w x 2.5"d x 6'h) are the size of one cabinet?
c. How are the suits intended to be stored? (The drawings show hanging suits, but the description makes it sound like they will be stored on shelves) ANSWER: a. 6 cabinets is too many it should be 2 cabinets if spacing allows for it
b. Yes that is the size of one cabinet.
c. The suits are required to be hung.
5. The spec requires “7'w x 2.5'd x 4'h work bench with a 1/2" lip on the work surface and with (2) 3'w x 2.5'd x 3'h tool storage boxes underneath”. What style of tool storage boxes are wanted? (Are they to be open top crates that will simply be slid out from underneath the work surface in order to access the tools? or other?)
ANSWER: Tool storage boxes are not crates, they will need 4 sliding shelves on each end and if they can have doors on those cabinets.
6. The spec requires “(2) 2'w tool boards with 4 adjustable brackets (placed 5'h off the deck)”. What are these 4 adjustable brackets being used for? (it is difficult to define brackets—and, therefore, their pricing— without knowing the intent of use) ANWER: The brackets are used to store axes, halogen tools, and large crowbars.
The following have been deleted:
SPECIFICATIONS
(End of Summary of Changes)