- Fire Extinguisher Maintenance Services Federal contract opportunity
- Solicitation number
- N0040621R0011
About this file
This is a solicitation for fire extinguisher maintenance services. The Navy seeks annual inspection, maintenance, testing, hydrostatic testing, disposal and replacement services for various types of portable and wheeled fire extinguishers across installations in the Northwest region. Required services include inspection and maintenance of over 3,700 handheld portable extinguishers and 84 wheeled 65lb extinguishers annually. Additional CLINs cover maintenance of other extinguisher types on six-year or twelve-year cycles. The solicitation also includes CLINs for repair parts, replacement extinguishers and disposal services. The response due date is May 13, 2021. The anticipated award is a fixed-price service contract. The Navy will make a single-award to the offeror whose quote is in the best interest of the government considering price and other factors.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 2.1.1a 21R0011 P00006 Sol Amend 6.pdf | ||
| 2.1.1a 21R0011 P00006 Sol Amend 6 Conform.pdf | ||
| 2.1.1a 21R0011 P00003 Sol Amend 6.pdf | ||
| 2.1.1a 21R0011 P00003 Sol Amend 6 Conform.pdf | ||
| 2.1.1a 21R0011 P00005 Sol Amend 5.pdf | ||
| 2.1.1a 21R0011 P00004 Sol Amend 4 Conformed.pdf | ||
| 2.1.1a 21R0011 P00003 Sol Amend 3.pdf | ||
| N0040621R0011 P00003 Solicitation Amendment 3.pdf | ||
| N0040621R0011 P00003 Solicitation Amendment 3 Conformed.pdf | ||
| N0040621R0011 P00002 Solicitation Amendment 2.pdf | ||
| N0040621R0011 P00002 Solicitation Amendment 2 Conformed.pdf | ||
| N0040621R0011 P00001 Solicitation Amendment 1.pdf | ||
| N0040621R0011 P00001 Solicitation Amendment 1 Conformed.pdf | ||
| N0040621R0011 Solicitation.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
Amendment to extend the solicitation, update CLINs, update the PWS in section C, update Addedum to 52.212-1, and to provide clarification in Section A.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 196
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 29-Apr-2021
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N0040621R0011
X 9B. DATED (SEE ITEM 11)
12-Mar-2021
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
29-Apr-2021
CODE
NAVSUP FLC PUGET SOUND
467 W STREET, 2ND FLR
ATTN: BROOKE BUTCHER
BREMERTON WA 98314
N00406 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N0040621R0011
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SECTION SF30 - CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed from 30-Mar-2021 03:00 PM to 13-May-
2021 03:00 PM.
The following have been added by full text:
MOD P00004 SUMMARY
Amendment to extend the solicitation and to provide clarification:
1) FAR 52.219-14 applies to this solicitation. "At least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern."
2) Technical Clarification: Contractors and any subcontractors must both meet the technical requirements for this solicitation. Since the contractor is required to do at least 50% of the work, they need to have the required technical capabilities. Offerors must submit proof of meeting one of the criteria listed in 4.6 of the Performance Work Statement (PWS) located in section C of this solicitation. Proof being a copy of each workers certification who is expected to be working on fire extinguishers.
3) Addendum to 52.212-1 updated for submission requirements. Exemptions: At this time, no exemptions have been approved for this solicitation. Any request for exemptions or questions about the PWS must be submitted to the contract specialist no later than five days prior to the solicitation due date. If exemptions or requested changes are approved by the contracting officer, approval will be given by amending the solicitation.
4) 52.212-2 updated for clarity.
5) Performance Work Statement located in Section C updated to provide more clarity on the requirement.
6) CLIN structure updated. Service calls CLIN is now separated per location. Descriptions for CLINs also updated.
The following have been modified:
NOTICE TO INTERESTED PARTIES
1. This solicitation is for the procurement of maintenance and servicing of portable fire extinguishers. It is anticipated that this solicitation will result in an award of a Firm, Fixed-Price Service type contract.
2. The entire solicitation shall be filled out, signed, and returned as part of your quote. See block 8 on page 1 of the solicitation for the closing date and time.
3. The deadline for submission of questions regarding the solicitation’s terms, conditions, specifications, and/or the performance work statement (PWS) is five days prior to the solicitation’s closing date.
4. Quotes will be evaluated in accordance with 52.212-2. Also see Addendum 52.212-1.
5. SINGLE AWARD FOR ALL ITEMS: Due to the interrelationship of supplies and/or services to be provided hereunder, the Government reserves the right to make a single award to the quoter whose quote is considered in the best interest of the government, price and other factors considered. Therefore, quoters who quote less than the entire effort specified herein may be determined to be unacceptable.
6. All questions in regards to this solicitation shall be submitted, via email, to the Contract Specialist (listed below):
Name: Brooke Butcher Phone: 360-476-0844 Email: brooke.butcher@navy.mil
SECTION B - SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN description has changed from SERVICE CALLS to FIRE EXT. HANDHELD PORTABLES -
ANNUAL.
The CLIN extended description has changed from:
This is for service calls throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
To:
This is for annual inspection/maintenance of handheld portable fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed in Technical Exhibit 1 item 1. Record keeping and documentation included.
The pricing detail quantity has increased by 3,652.00 from 110.00 to 3,762.00.
CLIN 0002
The CLIN description has changed from FIRE EXT. HANDHELD PORTABLES - ANNUAL to FIRE
EXT. HALATRON 65LB - ANNUAL.
The CLIN extended description has changed from:
This is for annual inspection/maintenance of handheld portable fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed in Technical Exhibit 1 item 1.
This is for annual inspection/maintenance of Halatron, 65 lb Wheeled fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 2. Record keeping and documentation included.
The pricing detail quantity has decreased by 3,431.00 from 3,515.00 to 84.00.
CLIN 0003
The CLIN extended description has changed from:
This is for annual inspection/maintenance of Halatron, 150 lb. Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed in Technical Exhibit 1 item 2.
This is for annual inspection/maintenance of Halatron, 150 lb Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 3. Record keeping and documentation included.
CLIN 0004
The CLIN description has changed from FIRE EXT. HALATRON 65LB - ANNUAL to FIRE EXT.
2.5LB HALATRON MAINT & REFILL.
The CLIN extended description has changed from:
This is for annual inspection/maintenance of Halatron, 65 lb Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 3.
This is for six year maintenance and refill of 2.5lb Halatron fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 4. Record keeping and documentation included.
The pricing detail quantity has decreased by 80.00 from 84.00 to 4.00.
CLIN 0005
The CLIN description has changed from FIRE EXT. 2.5LB HALATRON MAINT & REFILL to FIRE
EXT. ABC 5LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of 2.5lb Halatron fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 4.
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 5. Record keeping and documentation included.
The pricing detail quantity has increased by 518.00 from 5.00 to 523.00.
CLIN 0006
The CLIN description has changed from FIRE EXT. ABC 5LB - MAINT & REFILL to FIRE EXT. ABC
10LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 5.
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 6. Record keeping and documentation included.
The pricing detail quantity has increased by 218.00 from 354.00 to 572.00.
CLIN 0007
The CLIN description has changed from FIRE EXT. ABC 10LB - MAINT & REFILL to FIRE EXT.
ABC 20LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 6.
This is for six year maintenance and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 7. Record keeping and documentation included.
The pricing detail quantity has decreased by 270.00 from 284.00 to 14.00.
CLIN 0008
The CLIN description has changed from FIRE EXT. ABC 20LB - MAINT & REFILL to FIRE EXT
30LB CLASS D SC - MAINT&REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 7.
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy
Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
item listed under Technical Exhibit 1 item 8. Record keeping and documentation included.
The pricing detail quantity has decreased by 8.00 from 10.00 to 2.00.
CLIN 0009
The CLIN description has changed from FIRE EXT. CLEAN AGENT - MAINT & REFILL to FIRE EXT
30LB CLASS D COP - MAINT&REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of Clean Agent (CleanGuard) fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 8.
This is for six year maintenance and refill of 30lb Class D Copper fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. item listed under Technical Exhibit 1 item 9. Record keeping and documentation included.
The pricing detail quantity has decreased by 9.00 from 10.00 to 1.00.
CLIN 0010
The CLIN description has changed from FIRE EXT. ABC 5LB - TEST & REFILL to FIRE EXT. CLEAN
AGENT - MAINT & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 9.
This is for six year maintenance and refill of Clean Agent (CleanGuard) fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 10. Record keeping and documentation included.
The pricing detail quantity has decreased by 220.00 from 221.00 to 1.00.
CLIN 0011
The CLIN description has changed from FIRE EXT. ABC 10LB - TEST & REFILL to FIRE EXT. ABC
5LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 10.
This is for twelve year hydro test and refill of ABC, 5 lb fire extinguishersthroughout Navy Region Northwest Installations in accordance with thePerformance Work Statement (PWS) located in Section C. Item listed underTechnical Exhibit 1 item 11. Record keeping and documentation included.
The pricing detail quantity has decreased by 629.00 from 740.00 to 111.00.
CLIN 0012
The CLIN description has changed from FIRE EXT. ABC 20LB - TEST & REFILL to FIRE EXT. ABC
10LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 11.
This is for twelve year hydro test and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 12. Record keeping and documentation included.
The pricing detail quantity has increased by 484.00 from 58.00 to 542.00.
CLIN 0013
The CLIN description has changed from FIRE EXT 30LB CLASS D SC - MAINT&REFILL to FIRE
EXT. ABC 20LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
item listed under Technical Exhibit 1 item 12.
This is for twelve year hydro test and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 13. Record keeping and documentation included.
The pricing detail quantity has decreased by 2.00 from 4.00 to 2.00.
CLIN 0014
The CLIN description has changed from FIRE EXT 30LB CLASS D SC - TEST&REFILL to FIRE EXT.
CO2 15LB - TEST & REFILL.
This is for hydro test and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C under.
Item listed under Technical Exhibit 1 item 13.
This is for hydro test and refill of CO2, 15 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit 1 item 14. Record keeping and documentation included.
The pricing detail quantity has increased by 6.00 from 4.00 to 10.00.
CLIN 0015
The CLIN description has changed from FIRE EXT. CO2 15LB - TEST & REFILL to FIRE EXT. CO2
20LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of CO2, 15 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit 1 item 14.
This is for hydro test and refill of CO2, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit 1 item 15. Record keeping and documentation included.
The pricing detail quantity has decreased by 24.00 from 25.00 to 1.00.
CLIN 0016
The CLIN description has changed from FIRE EXT. CO2 20LB - TEST & REFILL to FIRE EXT 30LB
CLASS D SC - TEST&REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of CO2, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit 1 item 15.
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
item listed under Technical Exhibit 1 item 16. Record keeping and documentation included.
The pricing detail quantity has decreased by 13.00 from 15.00 to 2.00.
CLIN 0017
The CLIN description has changed from FIRE EXT. CLEAN AGENT - TEST & REFILL to FIRE EXT
30LB CLASS D COP - TEST&REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of Clean Agent (CleanGuard) fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 16.
This is for six year maintenance and refill of 30lb Class D Copper fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. item listed under Technical Exhibit 1 item 17. Record keeping and documentation included.
CLIN 0018
The CLIN description has changed from FIRE EXT. CLASS K - TEST & REFILL to FIRE EXT. CLEAN
AGENT - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of Class K fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 17.
This is for hydro test and refill of Clean Agent (CleanGuard) fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 18. Record keeping and documentation included.
The pricing detail quantity has decreased by 12.00 from 18.00 to 6.00.
CLIN 0019
The CLIN description has changed from FIRE EXT. 50LB WHEEL ABC - TEST & REFILL to FIRE
EXT. 2.5 GAL WATER - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of 50lb wheeled ABC fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 18.
This is for hydro test and refill of 2.5 gallon water fire extinguishers throughout Navy Region Northwest
Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 19. Record keeping and documentation included.
The pricing detail quantity has decreased by 2.00 from 3.00 to 1.00.
CLIN 0020
The CLIN description has changed from FIRE EXT. 2.5 GAL WATER - TEST & REFILL to FIRE EXT.
CLASS K 6LITER - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of 2.5 gallon water fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 19.
This is for hydro test and refill of Class K 6 liter fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 20. Record keeping and documentation included.
The pricing detail quantity has increased by 2.00 from 10.00 to 12.00.
CLIN 0021
The CLIN description has changed from FIRE EXT. HANDHELD DISPOSAL UP TO 50LB to FIRE
EXT. CLASS K 2.5GAL - TEST & REFILL.
The CLIN extended description has changed from:
This is for disposal of up to 50lb handheld fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 20.
This is for hydro test and refill of Class K 2.5 Gallon fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 21. Record keeping and documentation included.
The pricing detail quantity has decreased by 496.00 from 500.00 to 4.00.
CLIN 0022
The CLIN description has changed from FIRE EXT. WHEELED DISPOSAL 21-150LB to FIRE EXT.
HANDHELD DISPOSAL UP TO 20LB.
The CLIN extended description has changed from:
This is for disposal of between 21lb and 150lb wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 21.
This is for disposal of up to 20lb handheld fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 22. Record keeping and documentation included.
The pricing detail quantity has increased by 490.00 from 10.00 to 500.00.
CLIN 0023
The CLIN description has changed from NEW FIRE EXTINQUISHERS to FIRE EXT. WHEELED
DISPOSAL 21-150LB.
The CLIN extended description has changed from:
This is for replacement fire extinguishers in accordance with the PWS located in Section C. NTE $2,000 per contract year.
This is for disposal of between 21lb and 150lb wheeled fire extinguishersthroughout Navy Region Northwest Installations in accordance with thePerformance Work Statement (PWS) located in Section C. Item listed underTechnical Exhibit 1 item 23. Record keeping and documentation included.
The pricing detail quantity has decreased by 1,990.00 from 2,000.00 to 10.00.
CLIN 0024
The CLIN description has changed from REPAIR PARTS to NEW FIRE EXTINQUISHERS.
The CLIN extended description has changed from:
This is for repair parts and materials in accordance with the PWS located in Section C. NTE $3,500 per contract year.
This is for replacement fire extinguishers in accordance with the PWS located in Section C. NTE $2,000 per contract year. Record keeping and documentation included.
The pricing detail quantity has decreased by 1,500.00 from 3,500.00 to 2,000.00.
CLIN 0025
The CLIN description has changed from FIRE EXT 30LB CLASS D COP - MAINT&REFILL to
REPAIR PARTS.
The CLIN extended description has changed from:
This is for six year maintenance and refill of 30lb Class D Copper fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. item listed under Technical Exhibit 1 item 22.
This is for repair parts and materials in accordance with the PWS located inSection C. NTE $3,500 per contract year. Record keeping and documentation included.
The pricing detail quantity has increased by 3,496.00 from 4.00 to 3,500.00.
CLIN 0026
The CLIN description has changed from FIRE EXT 30LB CLASS D COP - TEST&REFILL to RECORD
KEEPING AND DOCUMENTATION NSP.
The CLIN extended description has changed from:
This is for hydro test and refill of 30lb Class D Copper fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C under. Item listed under Technical Exhibit 1 item 23.
This is for the deliverable of record keeping and documentation of fire extinguishers in accordance with the PWS located in Section C. This CLIN is Not Separately Priced.
The pricing detail quantity has increased by 8.00 from 4.00 to 12.00.
The unit of issue has changed from Each to Months.
The cost constraint has changed from NTE to NSP.
CLIN 1001
ANNUAL.
The CLIN extended description has changed from:
This is for service calls throughout Navy Region Northwest Installations in accordance with the Performance Work
This is for annual inspection/maintenance of handheld portable fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed in Technical Exhibit 1 item 1. Record keeping and documentation included.
CLIN 1002
EXT. HALATRON 65LB - ANNUAL.
This is for annual inspection/maintenance of handheld portable fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for annual inspection/maintenance of Halatron, 65 lb Wheeled fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 2. Record keeping and documentation included.
CLIN 1003
This is for annual inspection/maintenance of Halatron, 150 lb. Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for annual inspection/maintenance of Halatron, 150 lb Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
CLIN 1004
2.5LB HALATRON MAINT & REFILL.
The CLIN extended description has changed from:
This is for annual inspection/maintenance of Halatron, 65 lb Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for six year maintenance and refill of 2.5lb Halatron fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 4. Record keeping and documentation included.
The pricing detail quantity has decreased by 83.00 from 84.00 to 1.00.
CLIN 1005
EXT. ABC 5LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of 2.5lb Halatron fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 5. Record keeping and documentation included.
The pricing detail quantity has increased by 30.00 from 5.00 to 35.00.
CLIN 1006
10LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 6. Record keeping and documentation included.
The pricing detail quantity has decreased by 218.00 from 354.00 to 136.00.
CLIN 1007
ABC 20LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 7. Record keeping and documentation included.
The pricing detail quantity has decreased by 283.00 from 284.00 to 1.00.
CLIN 1008
30LB CLASS D SC - MAINT&REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
item listed under Technical Exhibit 1 item 8. Record keeping and documentation included.
The pricing detail quantity has decreased by 7.00 from 10.00 to 3.00.
CLIN 1009
30LB CLASS D COP - MAINT&REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of Clean Agent (CleanGuard) fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for six year maintenance and refill of 30lb Class D Copper fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. item listed under Technical Exhibit 1 item 9. Record keeping and documentation included.
CLIN 1010
AGENT - MAINT & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of Clean Agent (CleanGuard) fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 10. Record keeping and documentation included.
CLIN 1011
5LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for twelve year hydro test and refill of ABC, 5 lb fire extinguishersthroughout Navy Region Northwest Installations in accordance with thePerformance Work Statement (PWS) located in Section C. Item listed underTechnical Exhibit 1 item 11. Record keeping and documentation included.
The pricing detail quantity has decreased by 726.00 from 740.00 to 14.00.
CLIN 1012
10LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for twelve year hydro test and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 12. Record keeping and documentation included.
The pricing detail quantity has increased by 52.00 from 58.00 to 110.00.
CLIN 1013
EXT. ABC 20LB - TEST & REFILL.
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy
Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
This is for twelve year hydro test and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 13. Record keeping and documentation included.
The pricing detail quantity has decreased by 2.00 from 4.00 to 2.00.
CLIN 1014
CO2 15LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C under.
This is for hydro test and refill of CO2, 15 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit 1 item 14. Record keeping and documentation included.
The pricing detail quantity has decreased by 3.00 from 4.00 to 1.00.
CLIN 1015
20LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of CO2, 15 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit
This is for hydro test and refill of CO2, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit 1 item 15. Record keeping and documentation included.
CLIN 1016
CLASS D SC - TEST&REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of CO2, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
item listed under Technical Exhibit 1 item 16. Record keeping and documentation included.
The pricing detail quantity has decreased by 14.00 from 15.00 to 1.00.
CLIN 1017
30LB CLASS D COP - TEST&REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of Clean Agent (CleanGuard) fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of 30lb Class D Copper fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. item listed under Technical Exhibit 1 item 17. Record keeping and documentation included.
CLIN 1018
AGENT - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of Class K fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit
This is for hydro test and refill of Clean Agent (CleanGuard) fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 18. Record keeping and documentation included.
The pricing detail quantity has decreased by 17.00 from 18.00 to 1.00.
CLIN 1019
EXT. 2.5 GAL WATER - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of 50lb wheeled ABC fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for hydro test and refill of 2.5 gallon water fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 19. Record keeping and documentation included.
CLIN 1020
CLASS K 6LITER - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of 2.5 gallon water fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for hydro test and refill of Class K 6 liter fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 20. Record keeping and documentation included.
CLIN 1021
EXT. CLASS K 2.5GAL - TEST & REFILL.
The CLIN extended description has changed from:
This is for disposal of up to 50lb handheld fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit
This is for hydro test and refill of Class K 2.5 Gallon fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 21. Record keeping and documentation included.
The pricing detail quantity has decreased by 499.00 from 500.00 to 1.00.
CLIN 1022
HANDHELD DISPOSAL UP TO 20LB.
The CLIN extended description has changed from:
This is for disposal of between 21lb and 150lb wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for disposal of up to 20lb handheld fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 22. Record keeping and documentation included.
The pricing detail quantity has increased by 190.00 from 10.00 to 200.00.
CLIN 1023
DISPOSAL 21-150LB.
The CLIN extended description has changed from:
This is for replacement fire extinguishers in accordance with the PWS located in Section C. NTE $2,000 per
This is for disposal of between 21lb and 150lb wheeled fire extinguishersthroughout Navy Region Northwest Installations in accordance with thePerformance Work Statement (PWS) located in Section C. Item listed underTechnical Exhibit 1 item 23. Record keeping and documentation included.
CLIN 1024
The CLIN extended description has changed from:
This is for repair parts and materials in accordance with the PWS located in Section C. NTE $3,500 per contract
This is for replacement fire extinguishers in accordance with the PWS located in Section C. NTE $2,000 per contract year. Record keeping and documentation included.
CLIN 1025
REPAIR PARTS.
The CLIN extended description has changed from:
This is for six year maintenance and refill of 30lb Class D Copper fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. item listed
This is for repair parts and materials in accordance with the PWS located inSection C. NTE $3,500 per contract year. Record keeping and documentation included.
CLIN 1026
KEEPING AND DOCUMENTATION NSP.
The CLIN extended description has changed from:
This is for hydro test and refill of 30lb Class D Copper fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C under. Item listed
This is for the deliverable of record keeping and documentation of fire extinguishers in accordance with the PWS located in Section C. This CLIN is Not Separately Priced.
The pricing detail quantity has increased by 8.00 from 4.00 to 12.00.
CLIN 2001
ANNUAL.
This is for service calls throughout Navy Region Northwest Installations in accordance with the Performance Work
This is for annual inspection/maintenance of handheld portable fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed in Technical Exhibit 1 item 1. Record keeping and documentation included.
CLIN 2002
EXT. HALATRON 65LB - ANNUAL.
The CLIN extended description has changed from:
This is for annual inspection/maintenance of handheld portable fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for annual inspection/maintenance of Halatron, 65 lb Wheeled fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 2. Record keeping and documentation included.
CLIN 2003
This is for annual inspection/maintenance of Halatron, 150 lb. Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for annual inspection/maintenance of Halatron, 150 lb Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
CLIN 2004
2.5LB HALATRON MAINT & REFILL.
This is for annual inspection/maintenance of Halatron, 65 lb Wheeled fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for six year maintenance and refill of 2.5lb Halatron fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 4. Record keeping and documentation included.
CLIN 2005
EXT. ABC 5LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of 2.5lb Halatron fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 5. Record keeping and documentation included.
The pricing detail quantity has increased by 18.00 from 5.00 to 23.00.
CLIN 2006
10LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 6. Record keeping and documentation included.
The pricing detail quantity has decreased by 325.00 from 354.00 to 29.00.
CLIN 2007
ABC 20LB - MAINT & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 7. Record keeping and documentation included.
The pricing detail quantity has decreased by 278.00 from 284.00 to 6.00.
CLIN 2008
30LB CLASS D SC - MAINT&REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
item listed under Technical Exhibit 1 item 8. Record keeping and documentation included.
CLIN 2009
30LB CLASS D COP - MAINT&REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of Clean Agent (CleanGuard) fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed
This is for six year maintenance and refill of 30lb Class D Copper fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. item listed under Technical Exhibit 1 item 9. Record keeping and documentation included.
CLIN 2010
AGENT - MAINT & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 5 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for six year maintenance and refill of Clean Agent (CleanGuard) fireextinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 10. Record keeping and documentation included.
CLIN 2011
5LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for twelve year hydro test and refill of ABC, 5 lb fire extinguishersthroughout Navy Region Northwest Installations in accordance with thePerformance Work Statement (PWS) located in Section C. Item listed underTechnical Exhibit 1 item 11. Record keeping and documentation included.
The pricing detail quantity has decreased by 734.00 from 740.00 to 6.00.
CLIN 2012
10LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for twelve year hydro test and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under
This is for twelve year hydro test and refill of ABC, 10 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 12. Record keeping and documentation included.
The pricing detail quantity has decreased by 29.00 from 58.00 to 29.00.
CLIN 2013
EXT. ABC 20LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for six year maintenance and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C.
This is for twelve year hydro test and refill of ABC, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Item listed under Technical Exhibit 1 item 13. Record keeping and documentation included.
CLIN 2014
CO2 15LB - TEST & REFILL.
The CLIN extended description has changed from:
This is for hydro test and refill of 30lb Class D Sodium Chloride fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C under.
This is for hydro test and refill of CO2, 15 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit 1 item 14. Record keeping and documentation included.
CLIN 2015
20LB - TEST & REFILL.
This is for hydro test and refill of CO2, 15 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS) located in Section C. Items listed under Technical Exhibit
This is for hydro test and refill of CO2, 20 lb fire extinguishers throughout Navy Region Northwest Installations in accordance with the Performance Work Statement (PWS)…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .