16T0026_att.pdf
PDF 304 KB Posted
- Attached to
- COMPETITIVES-BAND LOAD CHASSIS Federal contract opportunity
- Solicitation number
- N0016416T0026
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 16T0026_sol.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPDT
SPDT
SPDT
Attenuator Coupler Load
SP6T
SPDT
SP6T
SPDT
SPDT Load
SPDT Load
SPDT Load
SPDT Load
SPDT Load
SPDT Load
SPDT
SPDT
SPDT
SPDT
SPDT
≥ 300W
≥ 300W
≥ 300W
≥ 300W
≥ 300W
≥ 300W
1 to 6 way Combiner/
Splitter
Back of the
PNA-X
Connections
Front of the
PNA-X
Connections
A p er at u re
Signal Analyzer
Attenuator
Load
Coupler
Attenuator
Load
Coupler
Attenuator
Load
Coupler
Attenuator
Load
Coupler
Attenuator
Load
Coupler
≥ 300W
≥ 300W
≥ 300W
≥ 300W
≥ 300W
≥ 300W
D is tr ib u ti o n
Port 1
Port 4
Port 2
Port 3
J3
J1
DUT
SPDT
NSWC Crane Division 300 Highway 361
Crane, Indiana 47522
Department of the Navy
Naval Surface Warfare Center
Schematic, S-Band Load Chassis
Dwg
No:
REV:
SIZE:
SCALE n/a SHEET 1 OF 1Prep By:
Rev By:
Proj Mgr:
Q.A.
Conf Mgr:
Br Mgr
KRB 9/30/15
INITIALS DATE
For Guidance Only. Unlimited Distribution.
Load
SPDTLoad
SPDTLoad
SPDTLoad
SPDTLoad
SPDTLoad
Notes:
· 19" Rack mount chassis needs to be used. Height needs to be equal to or less than 6U.
· Red lines highlight RF high power paths.
· Operating frequency range for system is 2- 4GHz
· All RF coax cable needs to be semi-rigid, preferred 0.141 size cable.
· Input AC power = 115VAC, 60Hz FRONT
PANEL
BACK
PANEL
NA
For Guidance Only. Unlimited Distribution.
This is an example layout of the front panel of the load box. The actual delivered layout may vary and could depend on component selection and other factors.
S-BAND LOAD CHASSIS
DISTRIBUTION
CH1 CH2 CH4 CH5 CH6
APERATURE
CH1 CH2 CH4 CH5 CH6CH3 CH3
System Status
AC PWR STAND-BY TX ERRORRX
VNA PORTS
P3 P4 P2P1
NSWC Crane Division 300 Highway 361
Crane, Indiana 47522
S-Band Load Chassis Front Panel
– Example Layout –
Dwg
No:
REV:
SIZE:
SCALE n/a SHEET 1 OF 1Prep By:
Rev By:
Proj Mgr:
Q.A.
Conf Mgr:
Br Mgr
KRB 9/30/15
INITIALS DATE
Aux RF Out
J3
Rear VNA J1
Notes:
Numbers of connectors on front panel shall be as follows:
12 RF DUT Ports with indications for port ON status 4 – VNA RF ports with indications for port ON status 1 – Auxiliary RF port for Signal Analyzer connection with indications for ON status as well as indications for J1 and J3 VNA port mounted on the rear panel on the S-Band Load Chassis.
S-Band Load Chassis shall have system status indications on the front panel Shall have an air circulation inlet or outlet on the front panel with the proper ventilation
For Guidance Only. Unlimited Distribution.
This is an example layout of the rear panel of the load box. The actual delivered layout may vary and could depend on component selection and other factors.
AC PWR
I O
Exhaust Fan 1 Exhaust Fan 2 Exhaust Fan 3
AC PWR IN
AC ON
AC OFF
GPIB COMM
NSWC Crane Division 300 Highway 361
Crane, Indiana 47522
S-Band Load Chassis Rear Panel
– Example Layout –
Dwg
No:
REV:
SIZE:
SCALE n/a SHEET 1 OF 1Prep By:
Rev By:
Proj Mgr:
Q.A.
Conf Mgr:
Br Mgr
KRB 9/30/15
INITIALS DATE
VNA REAR
PORTS
J3J1
GPIB
ADDRESS
SELECTOR
Notes:
Numbers of connectors on rear panel shall be as follows:
2 RF ports for the VNA connections J1 and J3 1 GPIB Digital communication port with GPIB Addressing selector to be able to change the remote control address of the chassis 1 AC Power connection with on/off switch
Shall have an air circulation inlet or outlet on the rear panel with the proper ventilation
| S_Band_Load_Chassis_Guidance_Drawings.vsd |
| SCH_rev3 |
| Front Panel |
| Rear Panel |
File details come from the government source that posted it. Updated .