Installation Path.pdf
PDF 9 MB Posted
- Attached to
- Optical Table with Vibration Isolation System Federal contract opportunity
- Solicitation number
- 1333ND24QNB680084
About this file
This document includes a combined synopsis/solicitation for an optical table with vibration isolation system along with an installation path document. The National Institute of Standards and Technology is seeking to install a 17' optical table system with minimum clearance of 52" at laboratory doors and 6'6" under unistrut racking. The 800ft installation path involves multiple turns through several buildings and requires minimum clearances of 76" in hallways and 80" in the laboratory. The site includes a loading dock, freight elevator, and two potential zones for mobile gantries near the laboratory entrance and away from the door on the other side of the unistrut racking. A mandatory site visit will be held on February 28, 2024 at 11am EDT at NIST Building 217/E116 to view the installation path.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| BMBarnes OpticalTables NIST Requirements.docx | DOCX document | |
| NIST Requirements.docx | DOCX document | |
| Combined Synopsis Solicitation.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Total estimated travel path: approximately 800 ft travel truck to lab with minimum clearance 52” at laboratory doors and one freight elevator. Surfaces are vinyl tiles, concrete, and granite.
About 10 turns, pivots, or shifts in direction required.
The loading dock (height 47”) is located in the basement level of Building 215.
Path from the truck through outer Steel Door (clear 121”) to interior loading dock is 28’.
Once inside, pivot 90° left, 14’ path to inner Steel Door (clear 108”).
Inner Steel Door to Double Door (clear 89”), path is 148’.
Path from double doors in basement of Building 215 to Basement of Building 217/219 is 45’ straight, a 20° right turn, a 12’ path, a 20° left turn, and a 54’ path.
Connecting hallwaty to Building 217/219 requires a 135° left turn.
Path is a 160’corridor with Storage items along left wall (narrowest clearance 76”) Path is then a turn 90 ° at an 8’ turning radius into Freight Elevator.
Freight elevator is 11.5’ deep, 13’ wide, load max > 13000 kg
Exit fright elevator on first floor into Building 217 turning right 180° at an 8’ turning radius Path is 14’ slightly to the left at 15° to align with double doors (clear 69”) Path is 67’ past double doors, turning 30° right, 13’ path, turning 30° left, 60’ path Pivot 90° left to hallway of the laboratory, 105’ path (min clearance 80”) Laboratory doors to be removed by NIST staff, (clear appx. 52”) Entrance to lab requires appx. 35° pivot to proceed through entrance.
Laboratory is 31’ x 23.5’ with 6’ 6” unistrut rack min clearance.
Align long axis of 17’ System inverted “L” with the 20’ of unistrut.
Unistrut is 3’ wide x 20’ long; 6” 6” minimum clearance Edge of 10’ x 5’ x 18” table roughly aligns with end of unistrut at left (required clearance 3’) edge of 5’ x 12’ x 18” table is offset 1’ such that table is centered with 3’ unistrut width.
Clearance around table approximately 3’ 6” (minimum of 3’ required) at far corner of 10’ x 5’ table.
It is anticipated that the tables enter the room on their sides (vertical to floor), to be flipped to orientation horizontal to floor. Mobile gantries for this purpose may be hindered by Unistrut above final table positions. Two zones where gantries would not be impeded are:
1) Near the lab entrance door, approximately 9.5’ deep x 17.5’ long, maximum and
2) Away from the door on the other side of the Unistrut, approximately 9’ deep x 25’ long, maximum.
FE
Double Door 89” clear
76” clear
156’ from 135° turn to freight elevator
~8’ turning radius
TH
IS
H
AL
LW
AY
L
EN
G
TH
N O
T
TO
S
CA
LE
9’ at 20°
Building 215 Basement Level
Building 217/219 Basement Level
135° turn
90° turn
60 feet
Double Door -stairs
FE
Narrowest Gap – 80”
Electrical panel, 17” from wall Pillar, 24” from wall
Emergency Eye Wash, 27” from wall
~60’
~67’
~13’ at 30°
~ 105’
~8’ turning radius
~14’ at 15°
FEFreight Elevator
Building 217 First Floot
LAB
60 feet
View is opposite of direction of travel
5’ x 12’ x 18”
5’ x 10 ‘ x 18” ft b uf fe r z on e
3.5 ft buffer zone
Unistrut minimum clearance 6’ 6”
5’ x 12’ x 18”
5’ x 10 ‘ x 18” ft b uf fe r z on e
3.5 ft buffer zone
(appx.) 9.5‘ x 17.5’ zone for mobile gantry
(appx.) 9‘ x 25’ zone for mobile gantry
All items and cabinetry against right wall will be removed, separate from this procurement, prior to table rigging.
All items and cabinetry against right wall will be removed, separate from this procurement, prior to table rigging.