Text version

Amendment No. A0001 RFQ No. HSCG40-14-Q-60786 This Amendment is issued to provide answers to questions received in response to this solicitation.

1. Question: Is the diesel engine to be a Tier 3 or Tier 4?

Answer: The diesel engine shall be Tier 3.

2. Question: Max pressure of 60,000 PSI”, is this correct? 60,000 PSI is used for cutting.

Answer: The max pressure should be 40,00psi rather than 60,000 psi. The SOW has been updated to reflect this change.

3. Question: The Specs call for “hooks” for lifting unit. Can this be a single point “lifting bail”?

Answer: The lifting unit will be a four point rig