Amendment No. A0001 RFQ No. HSCG40-14-Q-60786 This Amendment is issued to provide answers to questions received in response to this solicitation.
1. Question: Is the diesel engine to be a Tier 3 or Tier 4?
Answer: The diesel engine shall be Tier 3.
2. Question: Max pressure of 60,000 PSI”, is this correct? 60,000 PSI is used for cutting.
Answer: The max pressure should be 40,00psi rather than 60,000 psi. The SOW has been updated to reflect this change.
3. Question: The Specs call for “hooks” for lifting unit. Can this be a single point “lifting bail”?
Answer: The lifting unit will be a four point rig