TESTING REQUIREMENTS FOR SOLICITATION HC101318QB202

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS:

LINE RATE: 155.52MB/S 20 PPM.;

LINE CODE: OPTIC;

FRAME FORMAT. SONET/STS-3C;

1. TEST AND ACCEPTANCE: FIBER OPTIC OC-3C CIRCUITS

SHALL PASS A FULLY DOCUMENTED SATISFACTORY 72

HOUR SOAK TEST BY THE ATM NETWORK OPERATIONS

CENTER IT&A.;

2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING

TESTING PARAMETERS SHALL BE MEASURED DURING TEST AND

ACCEPTANCE TESTING. ERROR PERFORMANCE (AVAILABILITY,

SES, DM, EFS) AND LOSS OF BIT COUNT INTEGRITY SHALL

BE MEASURED AND RECORDED OVER THE DURATION OF THE

CONTIGUOUS 72 HOUR TESTING INTERVAL AND SHALL BE

MEASURED AND RECORDED PER DEFINITION IN ITU

RECOMMENDATION G.826 AND M.2100.;

3. ERROR PERFORMANCE:

ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING

PARAMETER THRESHOLDS TO BE ACCEPTABLE:

AVAILABILITY SHALL BE GREATER THAN 99.98%;

SEVERELY ERRORED SECONDS (SES) SHALL BE LESS THAN 0.02%;

DEGRADED MINUTES (DM) SHALL BE LESS THAN 0.2%;

ERROR FREE SECONDS (EFS) SHALL BE GREATER THAN 99%;

4. LOSS OF BIT COUNT INTEGRITY (LBCI): LOSS OF BIT

COUNT INTEGRITY SHALL BE MONITORED ONLY BY THE

FOLLOWING METHOD: USING TEST EQUIPMENT WHICH CAN

DETECT AND MEASURE THE OCCURRENCE OF THE INSERTION

OR DELETION OF ONE OR MORE BITS INTO THE DIGITAL

BIT STREAM, ON MANY MANUFACTURERS BERT TEST

EQUIPMENT THIS IS MONITORED USING THE "PATTERN

SLIP" PARAMETER WHERE EVERY OCCURRENCE OF A PATTERN

SLIP "EVENT" MARKS THE OCCURRENCE OF A LBCI (RATHER

THAN THE RAW TOTAL NUMBER OF PATTERN SLIPS

ACCUMULATED OVER A TESTING INTERVAL);

5. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI)

SHALL BE GREATER THAN 24 HOURS.;

6. ROUND TRIP DELAY (RTD): THE ROUND TRIP DELAY (RTD)

FOR THIS DISA IP BACKBONE CIRCUIT WILL BE MEASURED

IN MILLISECONDS FROM THE CUSTOMERS SERVICE DELIVERY

POINT (SDP) SITE-A TO THE CUSTOMERS SERVICE

DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS

THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY

SUPPORT THE GOVERNMENT'S MISSION.

7. THE VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE

OF OC-3C SERVICE IAW THE UNIQUE INSTALLATION FACTORS.;

8. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE

INSTALLATION FACTORS.;

9. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS

IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT

BOTH USER LOCATIONS. IF UNABLE TO REACH SITE POC'S

CONTACT KEN DIEF OR RAY BURKE FOR ASSISTANCE AT:

(301) 225-2416/2550.;

10. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT

AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED

TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN

CUSTOMER CONTACT CENTER (DCCC) SCOTT AFB, IL.

TOLL FREE: 1-855-868-9500; COML: 618-220-9500; DSN: 312-770-9500;

11. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW

DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL.

GUIDANCE ON SUBMISSION IS AVAILABLE AT

<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>.

CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE

COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES.";

12. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL

ADDRESSEES IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,

PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE

IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).

ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT

NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES

TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE

UPDATED.

13. COMPLETION REPORT: STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO

WILL SUBMIT COMPLETION REPORT IAW DISAC 310-130-1, SUPP 1, 2, 3

FORMAT OR DISAC 310-70-1. REPORT WILL BE ADDRESSED TO ORIGINATOR

AND ALL ADDRESSEES OF THIS TSO.

14. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY

SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING

DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE

DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS

1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032

OPTION 2, DSN 312-850-0032 OPTION 2.