Attachment-Circuit_Parameters_for_Solicitation_QB202.docx
DOCX document 13 KB Posted
- Attached to
- AWARD TO LEASE AN OC-3C SERVICE BETWEEN BLDG 10690, ROOM 158, 10690 ENDURING FREEDOM DRIVE, FORT DRUM, NY, AND 11 SOUTH TOWER (11ST) (ALSO KNOWN AS PEARKES BLDG), ROOM 70, 11 FL, 101 COLONEL BY DRIVE, OTTAWA, ONTARIO, CANADA. Federal contract opportunity
- Solicitation number
- HC101318QB202
- Issued by
- Defense Information Systems Agency
About this file
Circuit Parameters
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment-Testing_Requirements_for_Solicitation_QB202.docx | DOCX document | |
| HC101318QB202.v1_7-3-18.pdf | ||
| Solicitation_Vendor_Sample_Block_Diagram_Version3.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CIRCUIT PARAMETERS FOR SOLICITATION HC101318QB202
CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION:;
FRAME FORMAT: STS-3C, 1310NM;
RATE: PLUS OR MINUS 20 PPM;
USER PROVIDED STS-3C FRAMING FROM GOVT ROUTER;
(B) NO CHANNELIZATION REQUIRED.;
(C) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE
TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT
LEAST 99.98% OF THE TIME OR IAW THE APPROVED
TARIFFS.;
(D) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND
TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.
(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO
BE ENGINEERED INTO CIRCUIT.;
(F) SINGLE MODE FIBER TERMINATIONS SC/SC CONNECTORS;
(G) NO NETWORK INTERFACE UNIT.;
(H) DEDICATED PATH.;
(I) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO
ASSIST IN ANY CIRCUIT OUTAGES.;
(J) THE VENDOR MUST TEST THE CIRCUIT END TO END FOR
72 HOURS UTILIZING A 2E23 TEST PATTERN.;
(K) THE VENDOR WINNING AWARD OF THIS OC-3C SERVICE
MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.;
(L) THE OC-3C SERVICE WILL BE ACCEPTED ON BEHALF OF
THE GOVERNMENT BY DISA GOC IP "B" AT SCOTT AFB,
IL. AFTER COMPLETION OF SATISFACTORY TEST BY
DISA GOC IP "B": (C) 618-220-8627 (D) 770-8627;
(M) THE VENDOR MUST PROVIDE:
1. THE LONG HAUL CIRCUIT
NUMBER;
2. THE 1-800 TROUBLE REPORT NUMBER; AND
3. THE LOCAL CIRCUIT IDENTIFIER FOR EACH LOCATION
TO THE ACCEPTING AUTHORITY PRIOR TO THE
GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST
BE COMPLETED AND TESTED PROPERLY IAW THE ORDER
PRIOR TO TURNUP TO THE GOVERNMENT.