STATEMENT OF WORK

MARFORSOC CCTV SYSTEM AND INSTALLATION

Government Intent: To expand the existing barracks CCTV system into RR123. Utilize Genetec licenses and equipment for continued use of the Genetec system throughout MARFORSOC.

RR123 CCTV Install

• Install network switches in RR123 comm rooms.

• Install UPS at all network switch locations.

• Install one pair of Comnet CNFE1002S1A/B media converters to connect the CCTV network at RR123 to the Genetec NVR in

RR400.

• Pull wire from the identified camera locations to network switches in RR123’s comm rooms.

• Run ethernet from the Genetec workstation location in RR123 to network switches in order to reach the server.

• Install camera mounts, brackets or ceiling kits depending on assigned location.

• Install twenty-six (26) cameras at the locations outlined in enclosure (1) of this SOW.

• Wall mount the workstation’s monitor.

• Install and set up the GENETEC workstation.

• Install the following in the duty hut of RR123 for CCTV monitoring:

o One (1) Genetec SVW-302E-SF1-S1000-I7 workstation o One (1) NEC P423 42” monitor o One (1) APC BR1500G o One (1) Keyboard o One (1) Mouse

• Program all cameras and the Genetec workstation.

• Pull fiber from RR134 to RR400.

• Connect the RR123 cameras to the existing Genetec workstation in RR400 for CCTV monitoring purposes

ASSUMPTIONS/CLARIFICATIONS

• CONTRACTOR MAY ASSUME THAT THE EXISTING CONDUIT INFRASTRUCTURE BETWEEN THE

BUILDING RR400 SERVER AND WORKSTATION IS AVAILABLE TO INSTALL THE NETWORK

CABLING BETWEEN THESE TWO LOCATIONS.

• CONTRACTOR MAY ASSUME THAT THE NETWORK CABLING BETWEEN THE BARRACKS

EQUIPMENT RACK ON THE 2ND FLOOR AND THE EXISTING WORKSTATION LOCATIONS ON

THE 1ST FLOORS ARE IN GOOD CONDITION AND REUSABLE.

• THE GOVERNMENT WILL PROVIDE SINGLE MODE FIBER BETWEEN THE COMM ROOMS IN

BARRACKS RR123 AND THE BUILDING RR134.

• THE NEW WORKSTATION WILL BE PROVIDED WITH AN APC UPS. AC POWER FOR THE UPS

WILL BE GOVERNMENT PROVIDED.

• THE ADMINISTRATOR WORKSTATION IN BUILDING RR400 WILL HAVE THE CAPABILITY TO

PROGRAM, CONFIGURE, AND SETUP THE DISPLAY THAT WILL BE SHOWN ON THE NEW

BARRACKS WORKSTATION.

• CONTRACTOR MAY ASSUME THAT THE GOVERNMENT WILL PROVIDE A FIBER PORT

ASSIGNMENT IN RR134 TO INTERCONNECT RR123 WITH THE EXISTING GENETEC SERVER

IN RR400.

• CONTRACTOR MAY ASSUME THAT NOTHING BEYOND A LADDER WILL BE REQUIRED FOR

CAMERA INSTALL IN THE REQUIRED LOCATIONS.

STATEMENT OF WORK
MARFORSOC CCTV SYSTEM AND INSTALLATION
Government Intent: To expand the existing barracks CCTV system into RR123. Utilize Genetec licenses and equipment for continued use of the Genetec system throughout MARFORSOC.
RR123 CCTV Install