FRONT
BACK
NOTES:
1. DIMENSIONS IN BRACKETS ARE IN MILLIMETERS.
2. (.XXX) = DECIMAL EQUIVALENT.
3. ARTWORK TO BE SUPPLIED BY USGS/HIF.
4 MATERIAL: .024 [0.61] THICK LEXAN.
LETTERING SHALL BE BLACK ON WHITE
BACKGROUND. MATTE FINISH BOTH SIDES.
63 [1.6] µm THIRD ANGLE PROJECTION
METRIC CONVERSION
DECIMAL [mm]
X.XX.XXX
.X X
X.X.XX
SURFACE FINISH:
ANGLES
1/16FRACTIONS
UNLESS OTHERWISE SPECIFIED DIMENSIONS
ARE IN INCHES AND INCLUDE PLATING
DECIMAL TOLERANCE [mm] = 0.13
= 1.6 = 0.8 = 0.38
.XXX .005
.XX .015
.X .030
- DO NOT SCALE THIS DRAWING -
UNITED STATES DEPARTMENT OF THE INTERIOR
GEOLOGICAL SURVEY - WATER RESOURCES DIVISION
PARTS LIST
NOTESDESCRIPTION
NO. REQ'D
APPROVALS
REVISION-DESCRIPTIONLTR. DATE
DATE
SCALE
TITLE
MATERIAL
SIZE DWG. NO. REV.
ITEM SH. QTY.
NO. SIZE DRAWING/PART NO. REQD.
DRAFTING CHECK:
DRAWN BY:
DESIGN CHECK:
DESIGN APPROVAL:
C
1/2
NIKKI DENTON
HRM/EJN
C.S. CLAYTON
DATA CARD
0106002FULL -
7/27/10 5/3/12 5/7/12
REVISED AND REDRAWN
7/27/10
REVISED AND REDRAWN
LINE PURGE
To purge the orifice line:
* Close valves 1, 2, and 3 in that order.
* Open valve 4 all the way.
* Allow nitrogen to flow for one minute or as needed.
* Close valve 4.
* Open valves 3, 2, and 1 in that order.
Flow-rate adjustment instructions are on the opposite side of this card.
3 2
FLOW RATE
ADJUSTMENT
This unit has been preset to 60 bubbles per minute.
The packing nut on the flow adjustment needle valve was tightened to eliminate leaking at the valve stem packing.
Loosen the packing nut before adjusting the flow rate.
Re-tighten the packing nut after the flow rate has been adjusted.
Purge instructions are on the opposite side of this card.
4.5 [114]
2.25 [57.2]
1.0 [25]
5.8 [146]
R.3 [6]4X Ø1-1/2 (1.500) THRU