UTICA

ROME

AIR FORCE RESEARCH

LABORATORY - AFRL

69 4

EXIT 33

EXIT 32

EXIT 31

NYS THRUWAY

C H

A P

P

IE

JA

M

E S

M A

R C

H S

T

MOHAWK DR.

C H

A P

P

IE

J A

M E

S B

L V

D

B L

V D

MACDILL ST.

TO CHESTNUT ST

TO

F

LO

YD

A V E

HANGAR RD

HILL R

D

ELLSWORTH RD

MARKET ST

M O

O D

Y S

T

H

IL

L R

D

BROOKS RD

O T

IS

S T

W R

IG

H T D

R

TO ROME

NYS RTE 49

TO UTICA

BUFFALO

NYS THRUWAY

ROCHESTER ROME

ALBANY

UTICA

SYRACUSE

R

TE

R

TE

7AIR FORCE

RESEARCH

LABORATORY

- AFRL SEE

VICINITY MAP

NYC

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e

D ra w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

CONTRACT OFFICE

MAIN SECURITY GATE

SECURITY OFFICE

CIVIL ENGINEERING OFFICE

AIR FORCE RESEARCH LABORATORY

SCALE: NTS

VICINITY MAP

SCALE: NTS

NY STATE MAP

SCALE: NTS

ROME RESEARCH SITE

ROME, NEW YORK

AIR FORCE RESEARCH LABORATORY

ALTER SUITES H4-D & H4-C

BUILDING 3

Beardsley:

© Beardsley

PROJECT

LOCATION

:0

:0

A

M C

P r o je c ts

A G

_V

B W

B .r v t

CS-101

CCL

CCL

ALTER SUITES H4-D & H4-C

BLDG 3

COVER SHEET

ALL TRADES

4/29/2015

HGG

BLDG. 31 13

150302

14139

DRAWING LIST

NUMBER NAME

CS-101 COVER SHEET

A-101 FLOOR PLAN

A-102 FURNITURE PLAN & DETAILS

F-001 SYMBOLS, SPECIFICATIONS AND DEMOLITION PLAN

F-101 FIRST FLOOR ALTERATION PLAN

M-101 MECHANICAL DEMOLITION PLANS

M-102 MECHANICAL ALTERATION PLANS

E-001 SYMBOLS AND ABBREVIATIONS

E-101 ELECTRICAL DEMOLITION PLAN

E-102 POWER ALTERATION PLAN

E-103 SUITE H4 LIGHTING DEMOLITION PLAN

E-104 SUITE H4 LIGHTING ALTERATION PLAN

E-601 LIGHTING WIRING DIAGRAM

SS

SD

SD

SD

SD

UP

MF

MF

MF

FM

M P

N

A-A

A-101

A-A

A-101

SUITE H4

REMOVE EXISTING

SHIELDED CHAMBER WALLS

REMOVE EXISTING SHIELDED CHAMBER

FLOOR AND ROOF IN IT'S ENTIRETY

INCLUDING EXISTING ACCESS FLOOR

SYSTEM AND ACOUSTIC PANEL CEILING

SYSTEM WITHIN SHIELDED CHAMBER.

PROVIDE ADA COMPLIANT

HANDRAIL EACH SIDE OF EXISTING

STAIR

EXISTING FURNITURE AND EQUIPMENT

TO REMAIN ON THIS SIDE OF ROOM

PROVIDE ACCESS FLOOR SYSTEM PANELS IN

EXISTING GRID AT AREA UNDER SHIELDED

CHAMBER

PROVIDE FABRIC COVERED ACOUSTIC WALL PANELS, 10' HIGH

A C O

U S T

IC

W A L L P

A N E L S

H

IG

H

P R

O V

ID

E F

A B

R

IC

C O

V E R

E D

REMOVE EXISTING SYSTEMS

FURNITURE & PARTITIONS.

STORE AT LOCATION

DESIGNATED BY THE

GOVERNMENT

REMOVE

EXISTING STUD

PARTITION

REMOVE

EXISTING VAT

FLOORING

PROVIDE VCT

FLOORING

TEMPORARY DUST PARTITION. EXTEND FROM TOP OF ACCESS FLOOR

TO UNDERSIDE OF LAY IN CEILING. CLOSE SPACE BETWEEN LAY IN

CEILING AND HARD CEILING ABOVE WITH POLYETHYLENE SHEETING

REPAINT ALL

WALLS

FIRST FLOOR

100'-0"

UNDERSIDE OF

STRUCTURAL GRID

113'-4"

M N

REMOVE EXISTING ACCESS FLOOR

SYSTEM WITHIN SHIELDED CHAMBER

REMOVE EXISTING ACOUSTIC PANEL CEILING

SYSTEM WITHIN SHIELDED CHAMBER

REMOVE & REPLACE ALL ACOUSTIC CEILING PANELS IN EXISTING GRID OVER SHIELDED CHAMBER AREA. MATCH EXISTING

EXISTING ACOUSTIC

PANEL CEILING SYSTEM

EXISTING CONCRETE FLOOR SLAB

REMOVE AND REPLACE ALL ACCESS FLOOR PANELS IN EXISTING GRID UNDER SHEILDED CHAMBER

EXISTING ACCESS FLOOR SYSTEM

1' -1

REMOVE EXISTING SHIELDED CHAMBER ROOF

M P

N

A-A

A-101

PROVIDE ACOUSTIC CEILING PANELS TO IN

EXISTING GRID AT SHIELDED CHAMBER

LOCATION. MATCH EXISTING.

PROVIDE 20' LONG POWER OPERATED

RECESSED PROJECTION SCREEN

PROJECT LOCATION

BUILDING 3

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:5 :5

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

A-101

CCL

CCL

ALTER SUITES H4-D & H4-C

BLDG 314139

FLOOR PLAN

ARCHITECTURAL

4/29/2015

HGG

BLDG. 32 13

150302

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

SCALE: 1/8" = 1'-0"A

SUITE H4 FLOOR PLAN

SCALE: 1/4" = 1'-0"A-A

SECTION THROUGH SHIELDED CHAMBER

SCALE: 1/8" = 1'-0"B

SUITE H4 REFLECTED CEILING PLAN

SCALE: 1" = 200'-0"

KEY PLAN

REMOVE EXISTING SYSTEMS FURNITURE AT SOUTHWEST

CORNER OF ROOM. STORE AT LOCATION DIRECTED BY

AFRL FOR USE IN FUTURE PROJECT.

FURNITURE DESIGN TO BE DEVELOPED IN FINAL DESIGN

SUBMISSION.

ASBESTOS ABATEMENT NOTES:

PERFORM ABATEMENT WORK IN ACCORDANCE WITH NEW YORK STATE DEPARTMENT OF LABOR

INDUSTRIAL CODE RULE 56 (12 NYCRR PART 56), EXCEPT AS NOTED IN THE SPECIFICATIONS, AND

OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS.

ASBESTOS-CONTAINING MATERIALS CONTAINING GREATER THAN 1% ASBESTOS BY WEIGHT

IDENTIFIED WITHIN THE WORK AREA INCLUDE:

· SPACKLING COMPOUND LOCATED WITHIN SUITE H4 AT GYPSUM BOARD SEAMS ON THE WALLS AND

CEILING.

· BROWN/WHITE 12”X12” VINYL FLOOR TILE LOCATED WITHIN CORRIDOR G ENTRANCEWAY NORTH

OF SUITE H4.

WHITE/GRAY 12”X12” VINYL FLOOR TILE LOCATED WITHIN CORRIDOR G ENTRANCEWAY NORTH OF

SUITE H4 CONTAINED LESS THAN 1% ASBESTOS BY WEIGHT. OSHA WORKER PROTECTION

STANDARDS AND OTHER APPLICABLE REGULATIONS WILL APPLY.

DISTURBANCES OF THE ASBESTOS-CONTAINING SPACKLING COMPOUND WHICH MAY INCLUDE

REMOVAL OF WALLS/CONDUITS OR PENETRATION INTO THE WALLBOARD MUST OCCUR UNDER

ASBESTOS ABATEMENT CONDITIONS.

REMOVAL OF THE ASBESTOS-CONTAINING BROWN/WHITE AND WHITE/GRAY VINYL FLOOR TILE IN

THE CORRIDOR ENTRANCEWAY NORTH OF SUITE H4 MUST OCCUR UNDER ASBESTOS ABATEMENT

CONDITIONS.

ALL ASBESTOS-CONTAINING MATERIAL SHALL BE PROPERLY PACKAGED PRIOR TO BEING

REMOVED FROM THE WORK AREA(S). ASBESTOS WARNING LABELS SHALL BE APPLIED TO THE

ASBESTOS WASTE BAGS. ALL ASBESTOS MATERIALS THAT ARE REMOVED FROM THE WORK AREA

(S) SHALL BE ACCOMPLISHED BY A WASTE SHIPMENT RECORD.

GENERAL ABATEMENT NOTES:

PAINTS WERE OBSERVED IN GOOD CONDITION AND ARE ASSUMED TO CONTAIN DETECTABLE

CONCENTRATIONS OF LEAD (GREATER THAN 0.5% LEAD BY WEIGHT). PERFORM HANDLING OF ALL PAINTS CONTAINING LEAD AND MATERIALS COATED WITH LEAD-CONTAINING PAINT IN ACCORDANCE

WITH OSHA 29 CFR PART 1926.62 AND OTHER APPLICABLE REGULATIONS.

CONTRACTOR IS RESPONSIBLE FOR KEEPING THE WORK AREA IN A CLEAN AND SAFE CONDITION.

CONTRACTOR SHALL ENSURE THAT UNCERTIFIED PERSONNEL OR UNAUTHORIZED VISITORS DO NOT ENTER ACTIVE WORK AREAS AT ANY TIME. PROVIDE ALL NECESSARY DUST BARRIERS TO PREVENT

THE SPREAD OF DUST FROM THE WORK AREA AND PREVENT ASBESTOS AND LEAD EXPOSURE TO

THE PUBLIC AND ENVIRONMENT.

PERSONNEL TRANSPORT ROUTE, DECONTAMINATION AREA, AND WASTE STORAGE AREA SHALL BE

COORDINATED AND APPROVED BY THE GOVERNMENT PRIOR TO THE START OF CONSTRUCTION.

ELECTRIC AND WATER SERVICE WILL BE SUPPLIED BY GOVERNMENT.

COORDINATE WITH GOVERNMENT'S REPRESENTATIVE REGARDING SCHEDULE AND PHASING.

DESIGN IS BASED ON A LIMITED HAZARDOUS MATERIAL SURVEY CONDUCTED BY BEARDSLEY

ARCHITECTS + ENGINEERS.

NOTE:

DOOR 101: REMOVE EXISTING DOOR, FRAME TO REMAIN. PROVIDE 3'-0" X 7'-0" FLUSH WOOD DOOR. HARDWARE SET HW-1.

TURN OVER XO-9 LOCK TO GOVERNMENT.

DOOR 102: REMOVE EXISTING DOOR, FRAME TO REMAIN. PROVIDE 3'-0" X 7'-0" FLUSH WOOD DOOR. HARDWARE SET HW-1.

TURN OVER XO-9 LOCK TO GOVERNMENT.

DISTURBANCES OF ASBESTOS-CONTAINING VINYL FLOOR TILE AND SPACKLING COMPOUND SHALL OCCUR UNDER ASBESTOS

ABATEMENT CONDITIONS, REFER TO ASBESTOS ABATEMENT NOTES ON THIS DRAWING.

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

1.

2.

3.

4.

5.

6.

1.

2.

3.

4.

5.

6.

1.

2.

3.

J J

M

P

N

A-102

E X

IS

T

IN

G F

U R

N

IT

U R

E T

O R

E M

A

IN

N E W

F U R

N

IT

U R

E N

IC

LOCATION OF SCREEN ABOVE

FIRST FLOOR

100'-0"

M

EXISTING STAIR

1' -1

1 1/2" DIAMETER ALUMINUM RAILS & POSTS.

EXTEND POSTS THROUGH ACCESS FLOOR

TO CONCRETE SLAB BELOW.

1'-0"

RAIL ON OPPOSITE

SIDE OF STAIR SIMILAR

ANCHOR RAIL ENDS TO WALL

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:0

A

M C

P r o je c ts

A G

_V

B W

B .r v t

A-102

Author

Designer

ALTER SUITES H4-D & H4-C

BLDG 314139

FURNITURE PLAN & DETAILS

ARCHITECTURAL

4/29/2015

Checker

BLDG. 33 13

150302

SCALE: 1/4" = 1'-0"A

FIRST FLOOR FURNITURE PLAN

SCALE: 1/4" = 1'-0"1

RAILING DETAIL

FIRE PROTECTION SYMBOL LEGEND

- EXISTING 1" CAPPED OUTLET

- PENDENT SPRINKLER

- PIPE RISE ABOVE

- DROP FROM BOTTOM OF PIPE

- PIPE TURNS DOWN

- PIPE CAP/PLUG

- CEILING EXHAUST/RETURN DIFFUSER

(SHOWN FOR REFERENCE ONLY)

- RECESSED FLUORESCENT LIGHT FIXTURE

(SHOWN FOR REFERENCE ONLY)

- EXISTING PIPING

- ITEM TO BE DEMOLISHED/REMOVED

FIRE PROTECTION ABBREVIATIONS

- CENTERLINE

- EXISTINGEX

- CONNECT TO EXISTING

M

N

HALON PIPE BELOW FLOOR

FORMER HALON TANK LOCATION

(TANK REMOVED)

HALON PIPE ABOVE CHAMBER CEILING

BACK TO RISER

EX. 4"

EX. 1 1/2"EX. 1 1/4"EX. 1"EX. 1"

EXISTING PIPING ± 1'-0" ABOVE

EXISTING SUSPENDED CEILING

EXISTING CEILING HEIGHT

± 10'-0" ABOVE FLOOR

EXISTING UPRIGHT PLUGGED

TEE'S (TYP)

EX. 2"

WORK AREA

BUILDING 3

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

F-001

NAF

GAH

ALTER SUITES H4-D & H4-C

BLDG 314139

SYMBOLS, SPECIFICATIONS

AND DEMOLITION PLAN

FIRE PROTECTION

4/29/2015

HGG

BLDG. 34 13

150302

SECTION 21 13 13 - WET-PIPE FIRE SPRINKLER SYSTEM

PART 1 - GENERAL

1.1 PERFORMANCE REQUIREMENTS

A. PROVIDE MODIFICATION TO AN EXISTING WET-PIPE SPRINKLER

SYSTEM AND PROVIDE PENDENT SPRINKLERS AT CEILING LEVEL

ABOVE LOCATION WHERE CHAMBER IS BEING REMOVED.

ADDITIONALLY REPLACE ALL EXISTING PENDENT SPRINKLERS IN H4D

SUITE WITH QUICK RESPONSE TYPE. PROVIDE ADDITIONAL SPRINKLER

COVERAGE IN EXISTING VESTIBULE ALONG SOUTH WALL OF SUITE.

REMOVE ABANDONED HALON SYSTEM IN CHAMBER IN IT'S ENTIRETY.

B. STANDARD-PRESSURE PIPING SYSTEM COMPONENTS: LISTED FOR

175-PSIG (1200-KPA) MINIMUM WORKING PRESSURE.

C. DESIGN SPRINKLER SYSTEM(S) USING INDICATED PIPE SIZES AND

PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED.

D. SPRINKLER SYSTEM DESIGN SHALL BE APPROVED BY AUTHORITIES

HAVING JURISDICTION.

1. SPRINKLER OCCUPANCY HAZARD CLASSIFICATIONS:

a. BUILDING SERVICE AREAS: ORDINARY HAZARD, GROUP 1.

1.2 SUBMITTALS

A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.

INCLUDE RATED CAPACITIES, OPERATING CHARACTERISTICS, AND

FURNISHED SPECIALTIES AND ACCESSORIES.

B. SHOP DRAWINGS: FOR WET-PIPE SPRINKLER SYSTEMS. INCLUDE

PLANS, ELEVATIONS, SECTIONS, DETAILS, TRADE COORDINATION

AND ATTACHMENTS TO OTHER WORK. PREPARE IN ACCORDANCE

WITH NFPA 13 FOR APPROVAL BY AUTHORITY HAVING JURISDICTION.

C. APPROVED SPRINKLER PIPING DRAWINGS: WORKING PLANS,

PREPARED ACCORDING TO NFPA 13, THAT HAVE BEEN APPROVED

BY AUTHORITIES HAVING JURISDICTION.

D. FIELD TEST REPORTS AND CERTIFICATES: INDICATE AND

INTERPRET TEST RESULTS FOR COMPLIANCE WITH PERFORMANCE

REQUIREMENTS AND AS DESCRIBED IN NFPA 13. INCLUDE

"CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR ABOVE

GROUND PIPING."

1.3 PROJECT CONDITIONS

A. INTERRUPTION OF EXISTING SPRINKLER SERVICE: DO NOT

INTERRUPT SPRINKLER SERVICE TO FACILITIES OCCUPIED BY OWNER

UNLESS PERMITTED UNDER THE FOLLOWING CONDITIONS:

1. NOTIFY OWNER REPRESENTATIVE NO FEWER THAN TWO DAYS IN

ADVANCE OF PROPOSED INTERRUPTION OF SPRINKLER

SERVICE.

1.4 EXTRA MATERIALS

A. FURNISH EXTRA MATERIALS THAT MATCH PRODUCTS INSTALLED

AND THAT ARE PACKAGED WITH PROTECTIVE COVERING FOR

STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS.

PART 2 - PRODUCTS

2.1 STEEL PIPE AND FITTINGS

A. STANDARD WEIGHT, BLACK-STEEL PIPE: ASTM A 53/A 53M, TYPE E,

GRADE B. PIPE ENDS MAY BE FACTORY OR FIELD FORMED TO

MATCH JOINING METHOD.

B. BLACK-STEEL PIPE NIPPLES: ASTM A 733, MADE OF ASTM A 53/A

53M, STANDARD-WEIGHT, SEAMLESS STEEL PIPE WITH THREADED

ENDS.

C. UNCOATED, GRAY-IRON THREADED FITTINGS: ASME B16.4, CLASS

125, STANDARD PATTERN.

D. GROOVED-JOINT, STEEL-PIPE APPURTENANCES:

1. UNCOATED, GROOVED-END FITTINGS FOR STEEL PIPING: ASTM A

47/A 47M, MALLEABLE-IRON CASTING OR ASTM A 536, DUCTILE-

IRON CASTING; WITH DIMENSIONS MATCHING STEEL PIPE.

2. GROOVED-END-PIPE COUPLINGS FOR STEEL PIPING: AWWA

C606 AND UL 213, RIGID PATTERN, UNLESS OTHERWISE

INDICATED, FOR STEEL-PIPE DIMENSIONS. INCLUDE FERROUS

HOUSING SECTIONS, EPDM-RUBBER GASKET, AND BOLTS AND

NUTS.

2.3 SPRINKLER SPECIALTY PIPE FITTINGS

A. BRANCH OUTLET FITTINGS:

1. STANDARD: UL 213.

2. PRESSURE RATING: 175 PSIG (1200 KPA) MINIMUM.

3. BODY MATERIAL: DUCTILE-IRON HOUSING WITH EPDM SEALS AND

BOLTS AND NUTS.

4. TYPE: MECHANICAL-T AND -CROSS FITTINGS.

5. BRANCH OUTLETS: GROOVED, PLAIN-END PIPE, OR THREADED.

2.4 SPRINKLERS

A. AUTOMATIC SPRINKLERS WITH HEAT-RESPONSIVE ELEMENT:

1. CHARACTERISTICS: NOMINAL 1/2-INCH (12.7-MM) ORIFICE WITH

DISCHARGE COEFFICIENT K OF 5.6, AND FOR "ORDINARY"

TEMPERATURE CLASSIFICATION RATING UNLESS OTHERWISE

INDICATED OR REQUIRED BY APPLICATION.

B. SPRINKLER FINISHES:

1. CHROME PLATED.

C. SPRINKLER ESCUTCHEONS: MATERIALS, TYPES, AND FINISHES FOR

THE FOLLOWING SPRINKLER MOUNTING APPLICATIONS.

ESCUTCHEONS FOR SEMI-RECESSED-TYPE SPRINKLERS ARE

SPECIFIED WITH SPRINKLERS.

1. CEILING MOUNTING: CHROME-PLATED STEEL, ONE PIECE, FLAT

OR CHROME-PLATED STEEL, TWO PIECE, WITH 1-INCH (25-MM)

VERTICAL ADJUSTMENT.

2.5 ESCUTCHEONS

A. GENERAL: MANUFACTURED CEILING, FLOOR, AND WALL

ESCUTCHEONS AND FLOOR PLATES.

B. ONE-PIECE, STAMPED-STEEL ESCUTCHEONS: CHROME-PLATED

FINISH WITH SET-SCREW OR SPRING CLIPS.

2.6 SLEEVES

A. GALVANIZED-STEEL-SHEET SLEEVES: 0.0239-INCH (0.6-MM)

MINIMUM THICKNESS; ROUND TUBE CLOSED WITH WELDED

LONGITUDINAL JOINT.

B. STEEL-PIPE SLEEVES: ASTM A 53/A 53M, TYPE E, STANDARD

WEIGHT, ZINC COATED, PLAIN ENDS.

PART 3 - EXECUTION

3.1 PIPING INSTALLATION

A. LOCATIONS AND ARRANGEMENTS: DRAWING PLANS, SCHEMATICS,

AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT

OF PIPING. INSTALL PIPING AS INDICATED, AS FAR AS PRACTICAL.

1. DEVIATIONS FROM APPROVED WORKING PLANS FOR PIPING

REQUIRE WRITTEN APPROVAL FROM AUTHORITIES HAVING

JURISDICTION.

B. PIPING STANDARD: COMPLY WITH REQUIREMENTS FOR

INSTALLATION OF SPRINKLER PIPING IN NFPA 13.

3.2 FIELD QUALITY CONTROL

A. TESTS AND INSPECTIONS:

1. LEAK TEST: AFTER INSTALLATION, CHARGE SYSTEMS AND TEST

FOR LEAKS. REPAIR LEAKS AND RETEST UNTIL NO LEAKS EXIST.

2. TEST, AND INSPECT SPRINKLER SYSTEMS ACCORDING TO NFPA

13, "SYSTEMS ACCEPTANCE" CHAPTER.

3. COORDINATE WITH FIRE-ALARM TESTS. OPERATE AS REQUIRED.

B. SPRINKLER PIPING SYSTEM WILL BE CONSIDERED DEFECTIVE IF IT

DOES NOT PASS TESTS AND INSPECTIONS.

C. PREPARE TEST AND INSPECTION REPORTS.

3.3 CLEANING

A. CLEAN DIRT AND DEBRIS FROM SPRINKLERS.

B. REMOVE AND REPLACE SPRINKLERS WITH PAINT OTHER THAN

FACTORY FINISH.

SCALE: 1/4" = 1'-0"A

FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

GENERAL NOTES

1. DISTURBANCES OF ASBESTOS-CONTAINING SPACKLING

COMPOUND MUST OCCUR UNDER ASBESTOS ABATEMENT

CONDITIONS. REFER TO ASBESTOS ABATEMENT NOTES ON

DRAWING A-101.

SCALE: 1" = 200'-0"

KEY PLAN

F

M F

M

P

N

EX. 1 1/2"EX. 1 1/4"EX. 1"EX. 1"

CAP/PLUG EXISTING

BRANCH LINE

CONNECT TO EXISTING

1" OUTLET IN TEE

FITTING LEFT BY

REMOVALS (TYP)

EX. 4"

EX. 4"

PROVIDE PENDENT

HEAD IN VESTIBULE

WORK AREA

BUILDING 3

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

F-101

NAF

GAH

ALTER SUITES H4-D & H4-C

BLDG 314139

FIRST FLOOR ALTERATION

PLAN

FIRE PROTECTION

4/29/2015

HGG

BLDG. 35 13

150302

SCALE: 1/4" = 1'-0"A

FIRST FLOOR FIRE PROTECTION ALTERATION PLAN

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

GENERAL NOTES

1. DISTURBANCES OF ASBESTOS-CONTAINING SPACKLING

COMPOUND MUST OCCUR UNDER ASBESTOS ABATEMENT

CONDITIONS. REFER TO ASBESTOS ABATEMENT NOTES ON

DRAWING A-101.

N

DISCONNECT & REMOVE

GLYCOL PUMP, PIPING,

SUPPORTS AND CONCRETE

PAD IN THEIR ENTIRETY

DISCONNECT AND REMOVE 18x8 SA

DUCT BETWEEN SHIELDED CHAMBER

AREA AND SUITE H4D SA DUCT

DISCONNECT AND REMOVE

LIEBERT AIR CONDITIONING

UNIT IN ITS ENTIRETY.

EXISTING SUITE H4D SA

DUCT TO REMAIN

DISCONNECT AND REMOVE

EXPANSION TANK, PIPING AND

SUPPORTS IN THEIR ENTIRETY

BUILDING EXTERIOR

DISCONNECT AND REMOVE

GLYCOL SUPPLY AND RETURN

PIPING LOCATED BELOW CHAMBER

FLOOR AND ABOVE SUITE H4D

RAISED FLOOR

REMOVE AND SAVE EXISTING 20x6 SA FLOOR

REGISTER. REINSTALLED FLOOR REGISTER IN

SUITE H4D RAISED FLOOR. REFER TO B/M-102

FOR LOCATION. (TYP)

SHIELDED

CHAMBER

AREA

SUITE

H4D

CORRIDOR

REMOVE GYP PARTITION AS

NECESSARY TO ALLOW ACCESS

INTO WALL CAVITY FOR PIPE

REMOVAL. PATCH AND MATCH

PARTITION ONCE ACCESS IS

NO LONGER REQUIRED

DISCONNECT AND REMOVE

1 1/2" GLYCOL SUPPLY AND

RETURN PIPING. CONTINUED

ON DRAWING B/M101

EXISTING CONVECTOR

TO REMAIN

DISCONNECT AND REMOVE 1 1/2"

GLYCOL SUPPLY AND RETURN

PIPING LOCATED WITHIN WALL

CAVITY

PATCH AND LEVEL FLOOR

BELOW CONCRETE PAD.

PREPARE SURFACE FOR NEW

FLOOR TILE

DISCONNECT AND REMOVE 1"

PUMPED CONDENSATE DRAIN

PIPING BETWEEN LIEBERT UNIT

AND PUMP CONDENSATE PIPING

ABOVE CORRIDOR CEILING. CAP

AND LABEL REMAINING PIPING

DISCONNECT AND REMOVE 3/4"

COLD WATER PIPING BETWEEN

LIEBERT UNIT AND COLD WATER

PIPING ABOVE CORRIDOR

CEILING. CAP AND LABEL

REMAINING PIPING

C W

P C D

WORK AREA

BUILDING 3

M

EXISTING EXPANSION JOINT

EXISTING WALKING

PADS TO REMAIN

DISCONNECT AND REMOVE

EXISTING DRY COOLER

EXISTING ANTENNA

(TYP)

DISCONNECT AND REMOVE

1 1/2" GLYCOL SUPPLY AND

RETURN PIPING AND ASSOCIATED

SUPPORTS IN THEIR ENTIRETY

DISCONNECT AND REMOVE

EXISTING 6"x4" TREATED LUMBER

TYPICAL FOR BOTH SIDES

PATCH AND MATCH EXTERIOR

SURFACE WHERE SUPPORT ARE

REMOVED (TYP)

DISCONNECT AND REMOVE 1 1/2" GLYCOL

SUPPLY AND RETURN PIPING. CONTINUED

ON A/M-101

- POSITIVE PRESSURE DUCT UP

- POSITIVE PRESSURE DUCT DN

- NEGATIVE PRESSURE DUCT UP

- NEGATIVE PRESSURE DUCT DN

- EXISTING PIPING

- BRANCH FROM BOTTOM OF PIPE

- PIPE ELBOW DOWN

- PIPE ELBOW UP

- PIPE CAP- AIRFLOW INDICATOR

- BRANCH FROM TOP OF PIPE

- KEYED NOTE

MECHANICAL SYMBOLS

MECHANICAL ABBREVIATIONS

NOTE: ALL SYMBOLS AND ABBREVIATION ARE NOT NECESSARILY USED

- POINT OF DISCONNECT FROM EXISTING

- POINT OF RECONNECT TO EXISTING

AHU

CONT

CW

DN

EX

PCD

RA

SA

TYP

- MECHANICAL EQUIPMENT

TO BE REMOVED

- FLOOR REGISTER

AIR HANDLING UNIT

CONTINUATION

COLD WATER

DOWN

EXISTING

PUMPED CONDENSATE DRAIN

RETURN AIR

SUPPLY AIR

TYPICAL

GENERAL NOTES:

A. DISABLE SUITE H4D NORTH AIR HANDLING UNIT

WHILE THE DUST BARRIER IS IN PLACE. ENABLE

UNIT UPON REMOVAL OF DUST BARRIER. REFER

TO B/M102 FOR NORTH AIR HANDLING UNIT LOCATION.

B. DISTURBANCES OF ASBESTOS-CONTAINING VINYL FLOOR TILE

AND SPACKLING COMPOUND MUST OCCUR UNDER ASBESTOS

ABATEMENT CONDITIONS. REFER TO ASBESTOS ABATEMENT

NOTES ON DRAWING A-101.

C. PATCH AND MATCH OPENINGS AFTER PIPES ARE REMOVED

FROM PARTITIONS AND EXTERIOR WALLS.

D. PATCH AND MATCH OPENINGS AFTER DUCTS ARE REMOVED

FROM PARTITIONS.

E. REFER TO SPECIFICATIONS FOR PROPER DISPOSAL OF

REFRIGERANTS WITHIN LIEBERT COOLING SYSTEM. DOCUMENT

AND REPORT REFRIGERANTS REMOVED FROM THE SYSTEMS

TO THE SITE ENVIRONMENTAL OFFICE. (RIOCV)

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

M-101

NAF

PES

ALTER SUITES H4-D & H4-C

BLDG 314139

MECHANICAL DEMOLITION

PLANS

MECHANICAL

4/29/2015

HGG

BLDG. 36 13

150302

SCALE: 1/4" = 1'-0"A

SUITE H4D HVAC DEMOLITION PLAN

SCALE: 1" = 200'-0"

KEY PLAN

SCALE: 1/4" = 1'-0"B

SUITE H4D HVAC ROOF DEMOLITION PLAN

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

UP

M P

N

EX 20x6 SA

FLOOR REGISTER

(TYP)

EX. 20x10 SA

FLOOR REGISTER

(TYP)

EX. 40x20 RA OPENINGS

ABOVE LAY-IN CEILING

(TYPICAL OF 4)

M-102

REINSTALL FLOOR REGISTER IN SUITE H4D

RAISE FLOOR (TYP 18).

ADJUST PATTERN TO AVOID INTERFERENCE

WITH ROOM FURNITURE.

SEE GENERAL NOTE B BELOW.

WORK AREA

BUILDING 3

M P

N

PROVIDE (6) 22x22 EGGCRATE RETURN GRILLES

WITH 1/2" ALUMINUM CORE GRID AND ALUMINUM

BORDER. EQUAL TO TITUS MODEL 50F. ADJUST

LOCATION TO AVOID INTERFERENCE WITH LIGHT

FIXTURES AND OTHER CEILING FIXTURES

M-102

EXISTING EGGCRATE RETURN

AIR GRILLES TO REMAIN (TYP)

6 7

EXISTING RA DUCTS

TO AHU NORTH FROM

CEILING CAVITY

CONCRETE ROOF DECK

STEEL JOIST

GYP CEILING

LAY-IN CEILING

SUITE H4D

RAISED FLOOR

CONCRETE FLOOR

CAP EXISTING 18x8 SA

DUCT AT SA DUCT MAIN

2'-0" ±

10'-0" ±

3'-0" ±

2'-0" ±

4'-0" ±

1'-6" ±

E X x

S A

EXTERIOR WALL

EX SA DUCTS FROM

AHU NORTH TO RAISED

FLOOR

EXISTING CEILING

GRILLE (TYP)

EXISTING FLOOR

REGISTER (TYP) EXISTING

WALL REGISTER

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

M-102

NAF

PES

ALTER SUITES H4-D & H4-C

BLDG 314139

MECHANICAL ALTERATION

PLANS

MECHANICAL

4/29/2015

HGG

BLDG. 37 13

150302

SCALE: 1/8" = 1'-0"B

SUITE H4D MECHANICAL FLOOR PLAN

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

SCALE: 1" = 200'-0"

KEY PLAN

SCALE: 1/8" = 1'-0"A

SUITE H4D MECHANICAL REFLECTED CEILING PLAN

EXISTING SUITE H4

AHU SOUTH LOCATED

ON MEZZANINE

EX RA DUCT

EX SA DUCT

EX 40x20 SA REGISTER

BELOW RAISED FLOOR

(TYPICAL OF 4)

EXISTING SUITE H4

AHU NORTH LOCATED

ON MEZZANINE

EX RA DUCT

EX SA DUCT

SCALE: NOT TO SCALE1

SUITE H4D BUILDING SECTION

EX 40x20 SA DUCTS UP

TO RESPECTIVE SUITE AHU

(TYPICAL OF 4)

GENERAL NOTES:

A. DISTURBANCES OF ASBESTOS-CONTAINING SPACKLING

COMPOUND MUST OCCUR UNDER ASBESTOS

ABATEMENT CONDITIONS. REFER TO ASBESTOS

ABATEMENT NOTES ON DRAWING A-101.

B. COORDINATE INSTALLATION OF EXISTING FLOOR

REGISTERS WITH TILE MANUFACTURER. INSTALL

REGISTERS ACCORDING TO MANUFACTURERS WRITTEN

INSTRUCTIONS.

A AMPERE

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISH FLOOR

AIC AMPERES INTERRUPTING CAPACITY

APPROX APPROXIMATELY

MAX MAXIMUM

MFR MANUFACTURER

ABBREVIATIONSLIGHTING SYMBOLS

RECESSED LIGHT FIXTURE; A1 INDICATES FIXTURE TYPE (REFER TO LIGHT

FIXTURE SCHEDULE)

A1

LEGEND

ITEMS TO BE REMOVED FROM JOB SITE OR TURNED OVER TO THE OWNER

IF SO NOTED

EXISTING ITEMS TO REMAIN

FIRE ALARM SYMBOLS

MANUAL PULL STATION; MOUNT AT 4'-0" AFF UNOF

NOTIFICATION APPLIANCE (AUDIO/VISUAL)F

DOWNLIGHT

SD SMOKE DETECTOR

NOTIFICATION APPLIANCE (AUDIO ONLY)F

NOTIFICATION APPLIANCE (VISUAL ONLY)F

SMOKE DAMPER SMOKE DETECTORSD

DUCT SMOKE DETECTORDD

GENERAL NOTES

1. UNLESS NOTED OTHERWISE, THE MAXIMUM NUMBER OF HOME RUN CIRCUITS IN A CONDUIT

SHALL BE 3. EACH CIRCUIT SHALL CONTAIN DEDICATED NEUTRAL AND GROUND CONDUCTORS.

2. POWER AND LIGHTING CIRCUITS SHALL NOT BE INSTALLED IN THE SAME CONDUIT.

3. BOND ALL JUNCTION, PULL AND OUTLET BOXES TO THE EQUIPMENT GROUNDING CONDUCTOR.

4. BOND ALL LIGHT FIXTURES TO THE EQUIPMENT GROUNDING CONDUCTOR.

6. PROVIDE CIRCUIT DESIGNATION ON JUNCTION BOX COVER PLATES FOR POWER AND LIGHTING

CONDUIT SYSTEMS LOCATED ABOVE CEILING OR BELOW RAISED FLOOR.

7. DO NOT USE LIGHTING FIXTURES AS RACEWAYS. CONNECT ALL LIGHT FIXTURES TO A JUNCTION

BOX WITH A LIGHT FIXTURE TAP THAT DOES NOT EXCEED SIX (6) FEET IN LENGTH.

12. ALL PENETRATIONS THROUGH FIRE/SMOKE BARRIERS SHALL BE FIRE STOPPED IMMEDIATELY

AFTER PENETRATION IS MADE. TEMPORARY FIRE STOPPING IS REQUIRED IF WORK IS NOT

COMPLETE AT TIME OF PENETRATION. FIRE STOPPING SHALL MEET RATING OF WALLS.

13. REPAIR/PATCH TO MATCH ALL SURFACES (WALL, FLOORS, CEILINGS, PAVEMENT, WALKWAYS, ETC.) DISTURBED DUE TO THIS WORK.

14. ALL MOUNTING HEIGHTS INDICATED ARE TO THE CENTER OF THE BOX, UNLESS NOTED OTHERWISE.

17. PROVIDE UPDATED TYPEWRITTEN PANEL DIRECTORY AT PANELBOARDS AFTER ELECTRICAL WORK IS

COMPLETE. INCLUDE ALL INFORMATION FOR EXISTING CIRCUITS.

18. NEW CIRCUIT BREAKERS SHALL BE LISTED AND LABELED TO THE PANEL MAKE AND MODEL.

ITEM TO BE REMOVED AND REINSTALLED IN NEW LOCATION. AFTER

REMOVAL, SAFELY STORE EQUIPMENT/DEVICE FOR REINSTALLATION.

COORDINATE WITH OWNER

RR

OS CEILING MOUNTED OCCUPANCY SENSOR

SINGLE POLE SWITCH; MOUNT AT 3'-6" AFF UNO

3 THREE WAY SWITCH

POWER SYMBOLS

SURFACE MOUNTED PANELBOARD

DUPLEX RECEPTACLE (NEMA 5-20R); MOUNT AT 1'-6" AFF UNO

JUNCTION BOX. HOME RUN TO PANELJ

MOTORM

DISCONNECT

BRANCH CIRCUIT HOMERUN. INDICATES 2#12 AND 1#12 GND UNLESS NOTED

OTHERWISE

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BKR BREAKER

C CONDUIT (ELECTRICAL RACEWAY)

CKT CIRCUIT

CU COPPER

EA EACH

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

GRS GALVANIZED RIGID STEEL

EMT ELECTRICAL METALLIC TUBING

HZ HERTZ

JB JUNCTION BOX

LED LIGHT EMITTING DIODE

MIN MINIMUM

OC ON CENTER

P POLE (PHASES ON A SWITCHING DEVICE)

PA PUBLIC ADDRESS

QTY QUANTITY

RR REMOVE AND REINSTALL AT NEW LOCATION INDICATED

SF SQUARE FEET

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

V VOLT

W WATT

WP WEATHERPROOF

XMFR TRANSFORMER

DOUBLE DUPLEX RECEPTACLE (NEMA 5-20R); MOUNT AT 1'-6" AFF UNO

LTG LIGHTING

FLOOR MOUNTED BOX WITH RECEPTACLE

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:0

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

E-001

NAF

CMP

ALTER SUITES H4-D & H4-C

BLDG 314139

SYMBOLS AND ABBREVIATIONS

ELECTRICAL

4/29/2015

HGG

BLDG. 38 13

150302

J J

F

SS

SD

F

SD

SD

SD

M P

N

BUILDING EXTERIOR

EXISTING

JUNCTION

BOX PPC

SR SR

D

C D

C

D C

D C

SR

SR

SR SR

EXISTING INNERDUCT

DOWN WALL THROUGH

FLOOR

REMOVE WIREWAY

AND ASSOCIATED

CIRCUITS

REMOVE PANEL

LVP-H4-7 FED

FROM LVP-H4-1

FIL COIL SR

SR

FIL COIL

SR

SR

SR

REMOVE 200A

DISCONNECT FOR FILTER

SWITCH. REMOVE CONDUIT

AND WIRING BACK TO

PANEL LVDP-H4-2

DC

DCKP

W

SR

2" C

M

CONDUIT UP TO ROOF CONDENSING

UNIT. REMOVE CONDUIT AND WIRING

TO UNIT

SEAL PENETRATION

WEATHERTIGHT UPON

CONDUIT REMOVAL

CIRC

PUMP

REMOVE 6"x6" WIREWAY

ABOVE DISCONNECTS

REMOVE 30A DISCONNECT

FOR OUTSIDE CONDENSING

UNIT

REMOVE 30A DISCONNECT

FOR CIRCULATING PUMP

REMOVE 30A DISCONNECT

FOR FILTER

SEAL EXISTING PENETRATION

UPON CONDUIT REMOVAL

SUITE H4

EXISTING 2"x8" CABLE

TRAY 94" AFF TO

REMAIN (TYP OF 4)

EXISTING 2"X12" CABLE

TRAY 94" AFF TO REMAIN

EXISTING 2"X12" CABLE

TRAY 94" AFF TO REMAIN

REMOVE 2"x8" CABLE

TRAY AND SUPPORTS

EXISTING PANEL

LVP-H4-2 (PPB)

EXISTING PANEL

LVP-H4-1 (PPA)

EXISTING PANEL

LVP-H4-8 (PPD)

EXISTING PANEL

LVP-H4-3 (PPE)

EXISTING PANEL

DCP-H4-1

OUT OF SERVICE

EXISTING PANEL

LVP-H4-5 (PPH)

EXISTING PANEL

LVP-H4-4 (PPG)

REMOVE PANEL

LVDP-H4-2 (RP-69)

EXISTING PANEL

HVP-H4-1 (RL-69)

EXISTING PANEL

LVDP-H4-1 REMAINS

REMOVE 2 1/2"

CONDUIT AND

WIRING

REMOVE 95 KVA

TRANSFORMER

REMOVE 1 1/4"

CONDUIT AND

WIRING

REMOVE 45 KVA

TRANSFORMER

REMOVE 3/4" PVC

REMOVE 1 1/4"

CONDUIT

REMOVE PANEL

LVP-H4-6 FED

FROM LVDP-H4-1

REMOVE EXISTING CONDUIT AND

CONDUCTORS BACK TO LVDP-H4-2

REMOVE EXISTING JUNCTION

BOX ABOVE FINISH CEILING

SEAL EXISTING PENETRATION

ON EACH SIDE

RR

RR

RR

RR

RR

RR

RRRR

RR

REMOVE SPECIAL PURPOSE

RECEPTACLE AND REUSE

AF-1 FLOOR BOX

EXISTING PANEL

LVP-H4-9 (PPF)

REMOVE 2"x12" CABLE

TRAY AND SUPPORTS

WORK AREA

BUILDING 3

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:0

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

E-101

BWB/NAF

CMP

ALTER SUITES H4-D & H4-C

BLDG 314139

ELECTRICAL DEMOLITION PLAN

ELECTRICAL

4/29/2015

HGG

BLDG. 39 13

150302

SCALE: 1/4" = 1'-0"A

SUITE H4 POWER DEMOLITION PLAN

KEYED NOTES

SURFACE MOUNTED RACEWAY DOWN TO BELOW RAISED FLOOR.

REMOVE RF FILTERS "BLUE BOXES" CONDUIT AND WIRING BACK TO

SOURCE.

REMOVE ADT SECURITY COMPONENTS AND TURN OVER TO AFRL.

REMOVE 10 FILTRON BOXES LOCATED HIGH ON THE WALL. REMOVE

ALL CONDUIT AND WIRING ASSOCIATED WITH EQUIPMENT BACK TO

SOURCE.

REMOVE 4"X4" WIREWAY, RECEPTACLES AND ASSOCIATED CONDUIT

AND WIRING BACK TO PANEL LVP-H4-6.

REMOVE COMMUNICATION CONNECTIONS AT LOWER PORTION OF

INTERIOR CHAMBER WALL.

REMOVE GROUND BAR AND MOUNTS SAVE GROUND BAR AND

MOUNTS FOR RELOCATION AND CONNECTION FOR UNDER EXISTING

SUITE FLOOR, REMOVE ALL BONDED CONNECTIONS.

REMOVE EXISTING SPEAKERS AND STORE FOR REINSTALLATION

NEAR NEW PROJECTION SCREEN LOCATION. COORDINATE SPEAKER

RELOCATION WITH AFRL.

REMOVE EXISTING AF-1 BOXES AND STORE FOR REINSTALLATION IN

ALTERED SUITE AREA. DISCONNECT EXISTING CONDUIT FROM BOXES

AND REMOVE WIRING BACK TO SOURCE.

REMOVE EXISTING SMOKE DETECTORS BELOW EXISTING CHAMBER

RAISED FLOOR. STORE SMOKE DETECTOR FOR REINSTALLATION

UNDER H4 SUITE H4 RAISED FLOOR. MODIFY EXISTING FIRE ALARM

CIRCUIT WITHIN H4 SUITE.

REMOVE EXISTING SMOKE DETECTORS ABOVE LIEBERT UNIT. TURN

DEVICES OVER TO AFRL. MODIFY EXISTING FIRE ALARM CIRCUIT

WITHIN SUIT H4.

REMOVE 100A DISCONNECT FOR CRAC UNIT. REMOVE CONDUIT,

WIRING AND ASSOCIATED EQUIPMENT BACK TO PANEL LVDP-H4-2,

CKT# 28, 30, 32. RELABEL 100A/3P CIRCUIT BREAKER AS SPARE.

EXISTING COMMUNICATION CABLES TO BE REMOVED BACK TO

EXISTING PORTION OF CABLE TRAY TO REMAIN. COIL EXISTING

CABLE FOR REINSTALLATION TO NEW LOCATIONS.

RELOCATE AF-1 FLOOR BOXES TO NEW FURNITURE. REFER TO

DRAWING E-102. EXTEND EXISTING CIRCUITRY (RACEWAY,WIRE) AS

REQUIRED TO NEW LOCATION.

DISCONNECT EXISTING LVP-H4-8 (PPD) FEEDERS FROM EXISTING

PANEL LVDP-H4-2. PROVIDE JUNCTION BOX ABOVE PANEL

LVDP-H4-2 AND EXTEND FEEDERS TO LVDP-H4-1 IN STORAGE

ROOM. PROVIDE CONDUIT AND CONDUCTORS FROM JUNCTION BOX

TO PANEL.

DISCONNECT EXISTING LVP-H4-9 (PPF) FEEDERS FROM EXISTING

PANEL LVDP-H4-2. PROVIDE JUNCTION BOX ABOVE PANEL

LVDP-H4-2 AND EXTEND FEEDERS TO LVDP-H4-1 IN STORAGE

ROOM. PROVIDE CONDUIT AND CONDUCTORS FROM JUNCTION BOX

TO PANEL.

REMOVE (2) RECEPTACLE CIRCUITS FROM LVDP-H4-2 TO UNDER

FLOOR. REMOVE EXISTING CONDUIT AND FEEDER BACK TO LVSB-17-

2. REMOVE EXISTING PANEL LVDP-H4-2. COORDINATE PANEL LVSB-

17-2 LOCATION WITH AFRL.

TEMPORARILY SUPPORT EXISTING COMMUNICATIONS CABLES.

REMOVE PORTION OF 2"X8" CABLE TRAY. REFER TO DRAWING E-102

FOR CABLE TRAY ALTERATION. PLACE CABLES BACK INTO CABLE

TRAY UPON INSTALLATION.

REMOVE 20A/3P CIRCUIT BREAKER IN POSITIONS 2,4,6. PROVIDE

125A/3P SQUARE D I-LINE BREAKER FOR LVP-H4-8 IN POSITION 2,4,

AND 6. REMOVE 20A/3P CIRCUIT BREAKER IN POSITIONS 8,10 AND

12. PROVIDE 100A/3P SQUARE D, I-LINE CIRCUIT BREAKER IN ITS

PLACE FOR PANEL LVP-H4-9 IN POSITIONS 8,10 AND 12. TURN OVER

(2) 20A/3P CIRCUIT BREAKERS REMOVED FROM PANEL LVDP-H4-1

TO AFRL.

GENERAL NOTES

1. AFRL TO REMOVE ALL COMMUNICATION (FIBER OPTIC) CABLING FROM

BELOW RAISED FLOOR WITHIN THE CHAMBER AREA.

2. DISTURBANCES OF ASBESTOS-CONTAINING SPACKLING COMPOUND

MUST OCCUR UNDER ASBESTOS ABATEMENT CONDITIONS. REFER TO

ASBESTOS ABATEMENT NOTES ON DRAWING A-101.

3. PROVIDE TYPEWRITTEN PANEL DIRECTORY IN ALL PANELS MODIFIED

AS PART OF THIS PROJECT.

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

UP

M P

N

BUILDING EXTERIOR

EXISTING

JUNCTION

BOX PPC

SEAL EXISTING PENETRATION

UPON CONDUIT REMOVAL

SUITE H4

EXISTING 2"x8" CABLE

TRAY 94" AFF (TYP OF 3)

EXISTING 2"X12" CABLE

TRAY 94" AFF

EXISTING 2"X12" CABLE

TRAY 94" AFF TO REMAIN

EXISTING PANEL

LVP-H4-2 (PPB)

EXISTING PANEL

LVP-H4-1 (PPA)

EXISTING PANEL

LVP-H4-8 (PPD)

EXISTING PANEL

LVP-H4-3 (PPE)

EXISTING PANEL

DCP-H4-1

OUT OF SERVICE

EXISTING PANEL

LVP-H4-5 (PPH)

EXISTING PANEL

LVP-H4-4 (PPG)

EXISTING PANEL

HVP-H4-1 (RL-69)

EXISTING PANEL

LVDP-H4-1

PROVIDE 2x12 CABLE TRAY

94" AFF. PROVIDE CENTER

HUNG SUPPORTS TO

STRUCTURE ABOVE CEILING

LVP-H4-1

CKT#31 LVP-H4-1

CKT#31

LVP-H4-1

CKT#24

LVP-H4-1

CKT#24

LVP-H4-2

CKT#39

LVP-H4-2

CKT#40

LVP-H4-2

CKT#39

PROVIDE 2x8 CABLE

TRAY 94" AFF.

LVP-H4-2

CKT#42

LVP-H4-2

CKT#42

LVP-H4-2

CKT#41

LVP-H4-2

CKT#41

EXISTING PANEL

LVP-H4-9

M

PROVIDE CONDUIT

BETWEEN PANEL

AND METER

CONNECT CABLE TRAY

TO EXISTING. UTILIZE

MANUFACTURER SUPPLIED

MEANS OF CONNECTION

RR RR

CONNECT CABLE TRAY

TO EXISTING. UTILIZE

MANUFACTURER SUPPLIED

MEANS OF CONNECTION

RR

RR

RRRRRR

RR

RR

PROVIDE 2X12 CABLE

TRAY 94" AFF. PROVIDE

CENTER HUNG SUPPORTS

PROVIDE 2X12 CABLE

TRAY 94" AFF. PROVIDE

CENTER HUNG SUPPORTS

PROVIDE 2x8 CABLE

TRAY 94" AFF.

PROVIDE 2x8 CABLE

TRAY 94" AFF.

LVP-H4-2

CKT#40

BOND EVERY

JOINT IN TRAY

WITH #6 AWG

1/2" THREADED ROD.

SUPPORT SPACING PER

MANUFACTURER'S

RECOMMENDATIONS

MANUFACTURER'S

CENTER HANGER

SUPPORT BASED ON

WIDTH OF TRAY

BLACK POWDER COAT

CABLE TRAY. SIZE AS

INDICATED

PROVIDE

MANUFACTURER'S SPLICE

CONNECTORS AT TRAY

SECTIONS

FASTEN TO BUILDING

STRUCTURE ABOVE

FINISH CEILING

WORK AREA

BUILDING 3

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

E-102

BWB/NAF

CMP

ALTER SUITES H4-D & H4-C

BLDG 314139

POWER ALTERATION PLAN

ELECTRICAL

4/29/2015

HGG

BLDG. 310 13

150302

SCALE: 1/4" = 1'-0"A

SUITE H4 POWER ALTERATION PLAN

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

KEYED NOTES

REINSTALL EXISTING AF-1 FLOOR BOXES WITH EXISTING

RECEPTACLES IN RAISED FLOOR TILE. PROVIDE 2#12 AND #12

GROUND IN RACEWAY TO INDICATED POWER PANEL. ROUTE

RACEWAY BELOW EXISTING RAISED FLOOR.

PROVIDE SQUARE D 20A/1P CIRCUIT BREAKER IN PANEL. CIRCUIT

BREAKER AIC RATING SHALL MATCH PANEL.

PROVIDE EMON CLASS 3000 METER WITH ETHERNET

COMMUNICATIONS ADJACENT TO PANEL. STUB COMMUNICATIONS

CONDUIT OUT TO CORRIDOR CABLE TRAY ABOVE FINISH CEILING.

REINSTALL EXISTING AF-1 FLOOR BOX. PROVIDE DOUBLE DUPLEX

RECEPTACLE IN PLACE OF SPECIAL PURPOSE RECEPTACLE.

PROVIDE 2#12 AND 1#12 GROUND IN RACEWAY INDICATED TO POWER

PANEL. ROUTE RACEWAY BELOW EXISTING RAISED FLOOR.

GENERAL NOTES

1. PROVIDE GROUND WIRE IN NEW CABLE TRAY. BOND TO EXITING

GROUND CONDUCTOR. PROVIDE MIN #6 AWG IN CABLE TRAY.

2. DISTURBANCES OF ASBESTOS-CONTAINING SPACKLING

COMPOUND MUST OCCUR UNDER ASBESTOS ABATEMENT

CONDITIONS. REFER TO ASBESTOS ABATEMENT NOTES ON

DRAWING A-101.

SCALE: NOT TO SCALE1

(BASKET TRAY) CABLE TRAY DETAIL CENTER HUNG

M P

N

D1

EMEMEMEMEM

WORK AREA

BUILDING 3

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_V

B W

B .r v t

E-103

BWB/NAF

CMP

ALTER SUITES H4-D & H4-C

BLDG 314139

SUITE H4 LIGHTING

DEMOLITION PLAN

ELECTRICAL

4/29/2015

HGG

BLDG. 311 13

150302

SCALE: 1/4" = 1'-0"A

SUITE H4 LIGHTING DEMOLITION PLAN

KEYED NOTES

REMOVE EXISTING TRACK LIGHTING WITH 6 HEADS.

DISCONNECT AND REMOVE EXISTING 2X4 FLUORESCENT FIXTURES

AND WIRING ABOVE CHAMBER CEILING GRID, APPROXIMATELY 13

FIXTURES.

RELOCATE EXISTING FIRE ALARM AND MASS NOTIFICATIONS

APPLIANCES TO NEW H4 SUITE CEILING. REFER TO DRAWING A/104

FOR LOCATION.

REMOVE EXISTING FIRE ALARM AND MASS NOTIFICATION

APPLIANCES AND TURN OVER TO AFRL.

REMOVE EXISTING CEILING MOUNTED SMOKE DETECTOR IN

CHAMBER. STORE EXISTING SMOKE DETECTOR FOR

REINSTALLATION ON H4 SUITE MODIFIED CEILING. MODIFY FIRE

ALARM CIRCUIT WITHIN H4 SUITE.

REMOVE EXISTING CEILING SPEAKER. PROVIDE CEILING TILE IN

PLACE OF REMOVED SPEAKER. REMOVE ALL ASSOCIATED WIRING

WITH SPEAKER.

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

GENERAL NOTES

1. EXISTING LIGHTING CIRCUITRY TO REMAIN UNLESS NOTED

OTHERWISE.

2. DISTURBANCES OF ASBESTOS-CONTAINING SPACKLING

COMPOUND MUST OCCUR UNDER ASBESTOS ABATEMENT

CONDITIONS. REFER TO ASBESTOS ABATEMENT NOTES ON

DRAWING A-101.

F

M F

M F

F M

M P

N

EM

EMEMEMEM

EXISTING PANEL

DCP-H4-1

OUT OF SERVICE

EXISTING PANEL

LVP-H4-5 (PPH)

EXISTING PANEL

LVP-H4-4 (PPG)

EXISTING PANEL

HVP-H4-1 (RL-69)

OSOSOSOS

OS OS OSOS

2 2 2

222 2

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1 A1 A1 A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

OSOS

3 LOW VOLTAGE

DIMMING 3-WAY

SWITCHES

3 LOW VOLTAGE

DIMMING 3-WAY

SWITCHES

a b c a b c aaaaaaaaa aaaa aaaaaaa aaaa aaaaaaa aaa bbb bbb bbbbbbbbbbbbb bbbbbbbbbb bbbbbbbbbb ccccccccc cc c a cc c cc c c cc c cc c cccc cccc ccc ccc

4 5

LVDP-H4-1

LVDP-H4-1

LVDP-H4-1

3 3333

WORK AREA

BUILDING 3

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_1

_V

_B

W B

.r v t

E-104

BWB/NAF

CMP

ALTER SUITES H4-D & H4-C

BLDG 314139

SUITE H4 LIGHTING

ALTERATION PLAN

ELECTRICAL

4/29/2015

HGG

BLDG. 312 13

150302

SCALE: 1/4" = 1'-0"A

SUITE H4 LIGHTING ALTERATION PLAN

0' 4'2' 8' 12'

SCALE : 1/4" = 1'-0"

KEYED NOTES

REINSTALL EXISTING NOTIFICATION APPLIANCES REMOVED FROM

CHAMBER AREA CEILING. CONNECT DEVICES TO THE EXISTING

NOTIFICATION APPLIANCE CIRCUIT IN ROOM.

PROVIDE WATTSTOPPER LMDC-100 DLM DUAL TECHNOLOGY

CEILING MOUNTED OCCUPANCY SENSOR.

RECONNECT EMERGENCY LIGHTING TO CIRCUIT 8, LVDP-H4-1.

PROVIDE WATTSTOPPER LMBC-300 DIGITAL NETWORK BRIDGE

ABOVE FINISH CEILING. PROVIDE CONNECTION TO EXISTING BACNET

SYSTEM. COORDINATE CONNECTION WITH AFRL.

PROVIDE (3) WATTSTOPPER LMRC-211 AND (2) WATTSTOPPER

LMRC-213 DIGITAL DIMMING ROOM CONTROLLERS ABOVE FINISH

CEILING. REFER TO E-601 FOR WIRING DIAGRAM.

RELOCATED FIRE ALARM NOTIFICATION APPLIANCES.

PROVIDE WATTSTOPPER LMDM-101 DIGITAL DIMMING WALL

SWITCHES. PROVIDE GANGABLE BOXES AND COVER PLATES FOR

SWITCHES AS REQUIRED

LIGHT FIXTURE SCHEDULE

TYPE DESCRIPTION LAMP BALLAST MOUNTING DESIGN BASIS

APPROVED

MANUFACTURERS REMARKS

A1 2x2 LED TROFFER LED - 2700 LUMEN

OUTPUT

- RECESSED - GRID

TYPE

METALUX

2ALNG-LD1-27-UNV-L83

5-CD-1

NO SUBSTITUTIONS

ACCEPTED

GENERAL NOTES

1. DISTURBANCES OF ASBESTOS-CONTAINING SPACKLING

COMPOUND MUST OCCUR UNDER ASBESTOS ABATEMENT

CONDITIONS. REFER TO ASBESTOS ABATEMENT NOTES ON

DRAWING A-101.

2. AFTER INSTALLATION OF RELOCATED FIRE ALARM DEVICES

IN SUITE AREA, PERFORM A TEST OF THE FIRE ALARM SYSTEM.

PROVIDE TEST RESULTS TO AFRL.

PROJECT TITLE:

P lo tt e d

F ile na m e

DESIGN FIRM Beardsley:

© Beardsley 2014

Air Force Research Laboratory

Rome Research Site, New York

Rev. Date Description Drawn Approved

PROJECT NO:

PROJECT MANAGER:

DESIGNER:

DRAFTER:

OF

rio:

riocc:

rios:

66abw/def:

date date date date rioc:

rioco:

riof:

user:

date date date date riocc:

riocv:

det 4/se:

user:

date date date date

Rome Research Site

M o d e l N am e w in g

DATE:SHEET:DRAWING NO: FACILITY NO:

SHEET TITLE:

:0

:5

A

M C

P r o je c ts

A G

_V

B W

B .r v t

E-601

BWB

CMP

ALTER SUITES H4-D & H4-C

BLDG 314139

LIGHTING WIRING DIAGRAM

ELECTRICAL

4/29/2015

HGG

BLDG. 313 13

150302

SCALE: NOT TO SCALE1

LIGHTING WIRING DIAGRAM

SCALE: NOT TO SCALE2

LIGHTING CONTROL WIRING DIAGRAM