Questions_and_Answers_Set_2.pdf

PDF 102 KB Posted

Attached to
Storage Aid System for Elmendorf AFB, AK Federal contract opportunity
Solicitation number
FA8604-18-R-8112
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

View the file

Other files for this federal contract opportunity

Other files attached to Storage Aid System for Elmendorf AFB, AK, newest first.
File Type Posted
Questions_and_Answers_Set_3.pdf PDF
Request_for_Proposal_revision_0003.pdf PDF
FA8604-18-R-8112_RFP_Amendment_0002_Extension.pdf PDF
PEL622-02_(REV1).dwg DWG drawing
RFP_questions_and_answers_-_set_1_(rev_2).pdf PDF
PEL622-03_(REV1).dwg DWG drawing
PEL622-01.dwg DWG drawing
RFP_questions_and_answers_-_set_1.pdf PDF
Request_for_Proposal_Revision_001.pdf PDF
Proposal_Checklist.Pricing_Summary_Sheet.docx DOCX document
PEL622-02.dwg DWG drawing
PEL622-03.dwg DWG drawing
PEL622-01.dwg DWG drawing
Request_for_Proposal.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions Set 2 – 24 Sept 18

Question 1: In regard to the mobile storage system proposed for the vault- 30”w x 48”d – closed, clip type shelving with 1000# / shelf capacity is not an industry standard, and I can find no one that has tooling to make it as spec’d. Will you accept a different type of shelving for the mobile system such as rivet?

Answer: The capacity of the bin shelving and mobile aisle system have been updated to 400 pounds/shelf and 1000 pounds per carriage foot. These updates should alleviate any of the manufacturer concerns.

Question 2: In regard to the mobile storage system proposed for the vault - Spec with raised floor would not be recommended for use with an electric lift with a 1000# load on it (based on the shelf spec). Raised floors are designed for foot traffic or at the most a light duty push cart with a light load. We would recommend imbedding the rails into the (assumed) concrete floor so that the concrete floor would be supporting the lift & load – not a raised floor.

Answer: Raised floor is required due to location of mobile aisle, imbedded rails are not feasible in a weapons vault.

Question 3: In regard to the mobile storage system proposed for the vault - Mobile system industry standard carriages are designed for 1000# per carriage foot. The suggested load requirement per these specs would require a minimum of 1600# per carriage foot. As the spec is written we do not believe there is a manufacturer that can meet this spec. including Spacesaver and PER Spacesaver for the requested type of system.

Answer: The capacity of the mobile aisle has been updated to 1000 pounds per square foot.

Question 4: In regard to the mobile storage system proposed for the vault - RE: the lock – design as spec’s does not fully lock the system – there will be (1) carriage face of shelving open at all times.

Answer: The stationary cabinet shall be a movable single sided carriage to allow the entire system to be closed and locked. AF Drawing PEL622-03 has been updated to reflect this change.

Question 5: I would like to ask if the engineer would accept 60” wide x 48” deep shelving on the mobile system, rather than 30” wide x 48” deep. Same capacity – same amount of storage.

Answer: This is acceptable.